06.11.2014 Views

Powerline Plan and Environ. Assessment Jan. 2013 - Flood Control ...

Powerline Plan and Environ. Assessment Jan. 2013 - Flood Control ...

Powerline Plan and Environ. Assessment Jan. 2013 - Flood Control ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Powerline</strong> <strong>Flood</strong> Retarding Structure<br />

Pinal County, AZ<br />

Draft Supplemental Watershed <strong>Plan</strong><br />

<strong>and</strong> <strong>Environ</strong>mental <strong>Assessment</strong><br />

The concept for Alternative 2 included reducing the existing structures to non-jurisdictional (by<br />

ADWR definition) size with auxiliary spillway heights of six feet. The <strong>Powerline</strong> IDSM alignment<br />

will be maintained for the reduced height <strong>Powerline</strong> structure. Upstream of the reduced structures,<br />

detention basins sized for the 100-year event would be constructed outside of the mesquite bosques<br />

to help preserve <strong>and</strong> protect the bosques. The basins would drain through the bosques <strong>and</strong> the basin<br />

bottom depth will be controlled by the existing principal outlet location. The existing conditions<br />

100-year 24-hour storage volume from the existing conditions 100-year HEC-1 models was used to<br />

size each of the basins, in addition to the 100-year sediment volume. No FRS rehabilitation is<br />

included.<br />

To evaluate the required excavation volume, the existing flood volume behind the FRS up to the<br />

spillway crest height of six feet was used as flood storage <strong>and</strong> was not included in the volume<br />

required for basin excavation. The remaining required storage volume would be provided in the<br />

excavated basins where the bottom depth of each basin is controlled by the existing principal outlet<br />

location. The basins were sized such that the footprint of each basin was contained within the<br />

existing modified easement. The estimated required basin areas <strong>and</strong> depths without freeboard are<br />

289 acres <strong>and</strong> ten feet for <strong>Powerline</strong>, 385 acres <strong>and</strong> six feet for Vineyard Road, <strong>and</strong> 538 acres <strong>and</strong><br />

seven feet for Rittenhouse FRS. The basins will be excavated an additional three feet each in depth<br />

to include the 100-year sediment storage.<br />

The opinion of probable cost for converting each FRS to a basin <strong>and</strong> reducing the dam heights to<br />

non-jurisdictional dams (as considered in the Level I analysis) is $190,690,000. This alternative<br />

was eliminated from further detailed study in the workshop conducted on April 26, 2011 due to<br />

high costs, operational complexity, lower flood protection level (100-year), <strong>and</strong> h<strong>and</strong>ling <strong>and</strong><br />

storage of excess earthwork spoils.<br />

Decommissioning <strong>Powerline</strong>, Vineyard Road, <strong>and</strong> Rittenhouse FRS by Converting all Three Dams<br />

to Levees that Drain south to a Basin that Outlets to Queen Creek (Alternative 3).<br />

The concept for Alternative 3 included converting <strong>Powerline</strong> <strong>and</strong> Vineyard Road FRSs to levees to<br />

meet FEMA <strong>and</strong> District criteria. Additionally, Rittenhouse FRS would be removed <strong>and</strong> a levee<br />

would be constructed further west <strong>and</strong> adjacent to the CAP canal. A 100-year detention basin<br />

would be constructed at the south end of the project with a gated outlet to Queen Creek Wash.<br />

A new gated at-grade outlet would be constructed at the south end of the 100-year basin to drain the<br />

basin to Queen Creek Wash. A new drainage channel would be constructed between the basin<br />

outlet <strong>and</strong> a new CAP overchute near Queen Creek Wash. A gated trash rack would be provided at<br />

the new outlet of the basin, <strong>and</strong> a new basin overflow spillway would be constructed to discharge<br />

flow in the same general flowpath as the existing Rittenhouse auxiliary spillway. The <strong>Powerline</strong><br />

<strong>Flood</strong>way would not be used under this alternative, but may be utilized as an alternative outlet.<br />

The invert elevation of the CAP overchutes at Queen Creek Wash is approximately 1,566 feet. In<br />

comparison, the inverts of the principal spillway outlets at <strong>Powerline</strong> <strong>and</strong> Vineyard Road FRSs are<br />

1,563.6 feet <strong>and</strong> 1,563.8 feet, respectively, lower than the invert elevation of the CAP overchutes at<br />

Queen Creek Wash. The low point of the PVR system <strong>and</strong> the existing CAP overchutes at Queen<br />

Creek Wash are separated by approximately 8.5 miles, so even if the overchutes were lowered three<br />

feet, the flowpath south to Queen Creek Wash would be effectively flat. The primary constraint of<br />

Alternative 3 is achieving positive drainage along the existing structure alignments to drain south to<br />

USDA- NRCS Page 5-4 <strong>Jan</strong>uary <strong>2013</strong><br />

Kimley-Horn <strong>and</strong> Associates, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!