Model:<br />
Frequency:<br />
Fuel Type:<br />
<strong>C33</strong> <strong>D5</strong> (X <strong>Series</strong>)<br />
<strong>50</strong><br />
<strong>Diesel</strong><br />
» Generator set data sheet<br />
<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.<br />
Spec sheet:<br />
Noise data sheet (Open/enclosed):<br />
Airflow data sheet:<br />
Derate data sheet (Open/enclosed):<br />
Transient data sheet:<br />
SS19-CPGK<br />
N<strong>D5</strong>0-OS5<strong>50</strong> / N<strong>D5</strong>0-CS5<strong>50</strong><br />
AF<strong>50</strong>-5<strong>50</strong><br />
D<strong>D5</strong>0-OS5<strong>50</strong> / D<strong>D5</strong>0-CS5<strong>50</strong><br />
T<strong>D5</strong>0-5<strong>50</strong><br />
Fuel consumption<br />
3-Phase Ratings<br />
Standby<br />
Prime<br />
kVA (kW)<br />
kVA (kW)<br />
33 (26.4)<br />
30 (24)<br />
1-Phase Ratings 28.3 (28.3) 25.7 (25.7)<br />
Load<br />
1/4 1/2 3/4 Full 1/4 1/2 3/4 Full<br />
gph<br />
0.7 1.0 1.4 2.0 0.5 0.8 1.2 1.6<br />
L/hr<br />
3 5 6 9 2 4 5 7<br />
<strong>Engine</strong><br />
<strong>Engine</strong> manufacturer<br />
<strong>Engine</strong> model<br />
Configuration<br />
Aspiration<br />
Gross engine power output, kWm<br />
BMEP at set rated load, kPa<br />
Bore, mm<br />
Stroke, mm<br />
Rated speed, rpm<br />
Piston speed, m/s<br />
Compression ratio<br />
Lube oil capacity, L<br />
Overspeed limit, rpm<br />
Regenerative power, kW<br />
Governor type<br />
Starting voltage<br />
Standby rating<br />
Cummins<br />
X 3.3 G1<br />
4 Cycle; In-line; 4 Cylinder <strong>Diesel</strong><br />
Naturally Aspirated<br />
36<br />
804<br />
91.7<br />
127<br />
1<strong>50</strong>0<br />
6.35<br />
18.5:1<br />
6.5<br />
1725 ±25<br />
2.4<br />
Mechanical<br />
12 Volts DC<br />
Prime rating<br />
32<br />
757<br />
Fuel flow<br />
Maximum fuel flow, L/hr<br />
Maximum fuel inlet restriction, mm Hg<br />
Maximum fuel inlet temperature (°C)<br />
40<br />
73<br />
60<br />
Air<br />
Combustion air, m 3 /min<br />
Maximum air cleaner restriction, kPa<br />
1.90<br />
2.5<br />
1.90<br />
©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and<br />
Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of Cummins Power<br />
Generation. Other company, product, or service names may be trademarks or service marks of others.
Exhaust<br />
Exhaust gas flow at set rated load, m 3 /min<br />
Exhaust gas temperature, ° C<br />
Maximum exhaust back pressure, kPa<br />
Standby rating<br />
2.3<br />
600<br />
4.75<br />
Prime rating<br />
2.3<br />
5<strong>50</strong><br />
Standard set-mounted radiator cooling<br />
<strong>50</strong><br />
Ambient design, ° C<br />
Fan load, KW m 0.9<br />
Coolant capacity (with radiator), L<br />
Cooling system air flow, m3/sec @ 12.7mmH2O<br />
9.6<br />
106<br />
Total heat rejection, BTU/min<br />
1653<br />
Maximum cooling air flow static restriction mmH2O<br />
0.3<br />
1539<br />
Open set derating factors kVA (kW)<br />
Note: Standard open genset options running at 400V, 1<strong>50</strong>m above sea level. For enclosed product derates, please refer to datasheet - D<strong>D5</strong>0-<br />
CS5<strong>50</strong>.<br />
Standby<br />
27°C<br />
33 (26.4)<br />
40°C<br />
33 (26.4)<br />
45°C<br />
31.5 (25.2)<br />
<strong>50</strong>°C 55°C<br />
29.9 (23.9)<br />
29 (23.2)<br />
Prime<br />
30 (24)<br />
30 (24)<br />
29.1 (23.3)<br />
28.3 (22.6)<br />
27.3 (21.8)<br />
Weights*<br />
Unit dry weight kgs<br />
Unit wet weight kgs<br />
Open<br />
Enclosed<br />
710<br />
1070<br />
875<br />
1235<br />
* Weights represent a set with standard features. See outline drawing <strong>for</strong> weights of other configurations<br />
Dimensions<br />
Standard open set dimensions<br />
Enclosed set standard dimensions<br />
Genset outline<br />
Length<br />
1753<br />
2242<br />
Width<br />
Height<br />
930<br />
12<strong>50</strong><br />
967 1513<br />
Open set<br />
Enclosed set<br />
Outlines are <strong>for</strong> illustrative purposes only. Please refer to the genset outline drawing <strong>for</strong> an exact representation of this model.<br />
©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and<br />
Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of Cummins Power<br />
Generation. Other company, product, or service names may be trademarks or service marks of others.
Alternator data<br />
Feature code<br />
TBC<br />
Connection 1<br />
Wye, 3 Phase<br />
Temp rise degrees C<br />
163/125<br />
Duty 2<br />
S/P<br />
Alternator<br />
PI144G<br />
Voltage<br />
380-440V<br />
Ratings definitions<br />
Emergency Standby Power (ESP) Limited-Time running Power Prime Power (PRP):<br />
Applicable <strong>for</strong> supplying power to Applicable <strong>for</strong> supplying power to a Applicable <strong>for</strong> supplying power to<br />
varying electrical load <strong>for</strong> the<br />
duration of power interruption of a<br />
constant electrical load <strong>for</strong> limited<br />
hours. Limited Time Running<br />
varying electrical load <strong>for</strong> unlimited<br />
hours. Prime Power (PRP) is in<br />
reliable utility source. Emergency Power (LTP) is in accordance with accordance with ISO 8528. Ten<br />
Standby Power (ESP) is in<br />
accordance with ISO 8528. Fuel<br />
Stop power in accordance with ISO<br />
3046, AS 2789, DIN 6271 and BS<br />
5514.<br />
ISO 8528.<br />
percent overload capability is<br />
available in accordance with ISO<br />
3046, AS 2789, DIN 6271 and BS<br />
5514.<br />
Base Load (Continuous) Power<br />
Applicable <strong>for</strong> supplying power<br />
continuously to a constant electrical<br />
load <strong>for</strong> unlimited hours.<br />
Continuous Power (COP) in<br />
accordance with ISO 8528, ISO<br />
3046, AS 2789, DIN 6271 and BS<br />
5514.<br />
Formulas <strong>for</strong> calculating full load currents:<br />
Three phase output<br />
kWx1000<br />
Voltagex1. 73x0.8<br />
Single phase output<br />
kWxSingleP haseFactor x1000<br />
Voltage<br />
See <strong>you</strong>r distributor <strong>for</strong> more in<strong>for</strong>mation.<br />
Cummins Power Generation<br />
Manston Park, Columbus Avenue<br />
Manston, Ramsgate<br />
Kent CT12 5BF, UK<br />
Telephone: +44 (0) 1843 25<strong>50</strong>00<br />
Fax: +44 (0) 1843 255902<br />
E-Mail: cpg.uk@cummins.com<br />
Web: www.cumminspower.com<br />
©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and<br />
Cummins are registered trademarks of Cummins Inc. PowerCommand and “<strong>Our</strong> <strong>energy</strong> <strong>working</strong> <strong>for</strong> <strong>you</strong>.” are trademarks of Cummins Power<br />
Generation. Other company, product, or service names may be trademarks or service marks of others.