<strong>Hot</strong> <strong>runner</strong> systems / manifolds<br />

Manifold power calculation (230 V)<br />

Power Voltage Current Approximate resistance<br />

Watt Volt A<br />

values to be measured in<br />

Ohm [S]<br />

2300<br />

3680<br />

1500<br />

1400<br />

1100<br />

1000<br />

750<br />

500<br />

630<br />

500<br />

400<br />

250<br />

600 (max.)<br />

600 (max.)<br />

P = U • I<br />

R = U/I<br />

P = U 2 / R<br />

Thermocouple<br />

cable<br />

Red = plus<br />

Blue = minus<br />

www.guenther-hot<strong>runner</strong>.com<br />

4/11 Subject to technical changes<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

230<br />

5<br />

24<br />

PE earthed lead<br />

Fig. Manifold - correlation of cables<br />

Example: 2<br />

P = (230 V) / 23 Ohm<br />

P = 2300 W<br />

10<br />

16<br />

6.5<br />

6.1<br />

4.8<br />

4.4<br />

3.3<br />

2.8<br />

2.2<br />

1.8<br />

1.4<br />

1.1<br />

125 (max.)<br />

25 (max.)<br />

23.0<br />

14.375<br />

35.4<br />

37.7<br />

47.9<br />

52.3<br />

69.1<br />

82.1<br />

104.5<br />

127.8<br />

164.3<br />

209.1<br />

0.1 - 0.2<br />

0.2 - 0.4<br />

Alternating current 230 V<br />

iT<br />

1.4. 54