Gating<br />

0.5<br />

At 250°C the hot <strong>runner</strong> <strong>nozzle</strong> extends 0.5 mm into<br />

the part if the <strong>nozzle</strong> is installed to the nominal<br />

length.<br />

Fig. <strong>Hot</strong> <strong>runner</strong> <strong>nozzle</strong> installed correctly<br />

Potential error sources<br />

Problem:<br />

- Higher vestige<br />

- No flow gap despite a larger gate<br />

Fig. Cylindrical part at the gate<br />

Problem: - No sufficient insulation gap<br />

- Higher temperature needed<br />

- Great temperature fluctuations<br />

- Stringing<br />

Fig. The forechamber contour not produced correctly<br />

www.guenther-hot<strong>runner</strong>.com<br />

4/11 Subject to technical changes<br />

iT<br />

Problem:<br />

- The expanded <strong>nozzle</strong> closes the gate.<br />

Fig. Gate