03.11.2012 Views

Expert Power Control NET - Manual - Gude Analog

Expert Power Control NET - Manual - Gude Analog

Expert Power Control NET - Manual - Gude Analog

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Expert</strong> <strong>Power</strong><br />

<strong>Control</strong> <strong>NET</strong><br />

<strong>Expert</strong> <strong>Power</strong> <strong>Control</strong> <strong>NET</strong><br />

1<br />

<strong>Expert</strong> <strong>Power</strong> <strong>Control</strong> <strong>NET</strong> IEC<br />

CONTACT<br />

<strong>Manual</strong><br />

<strong>Gude</strong> <strong>Analog</strong>- und Digitalsysteme<br />

GmbH<br />

Eintrachtstraße 113<br />

50668 Köln<br />

Germany<br />

tel.: +49-221-912 90 97<br />

fax: +49-221-912 90 98<br />

e-mail: info@<strong>Gude</strong>.info<br />

web: www.<strong>Gude</strong>.info<br />

TABLE OF CONTENTS<br />

After having modified the IP settings EPC <strong>NET</strong><br />

can be switched by all PCs of the same network 2 SWITCHING VIA ETHER<strong>NET</strong><br />

via the website http://”IP address of EPC <strong>NET</strong>“/<br />

1 OPENING INSTRUCTIONS<br />

(e.g. http://192.168.0.2/).<br />

Log in to the website http://”IP address of EPC<br />

<strong>NET</strong>”/ (e.g. http://192.168.0.2/). It might be<br />

1.1 Connection<br />

necessary to enter a password (see 3). Now<br />

1.2 IP Settings<br />

1.2 IP SETTINGS<br />

EPC <strong>NET</strong> can be switched.<br />

2 SWITCHING VIA ETHER<strong>NET</strong><br />

3 CONFIGURATION<br />

4 PRODUCT FEATURES<br />

4.1 Operating modi<br />

4.2 Changing of switching state<br />

4.3 Firmware Update<br />

4.4 Default settings<br />

4.5 LED<br />

4.6 Technical data<br />

FAQs<br />

1 OPENING INSTRUCTIONS<br />

1.1 CONNECTION<br />

<strong>Expert</strong> <strong>Power</strong> <strong>Control</strong> <strong>NET</strong> (EPC <strong>NET</strong>) must<br />

be connected to an electric circuit and the<br />

desired ethernet.<br />

For product version EPC <strong>NET</strong> IEC connect the<br />

device with enclosed IEC appliance connector<br />

as follows:<br />

Connection for device (female)<br />

Connection electric circuit (male)<br />

When EPC <strong>NET</strong> is connected to an electric<br />

circuit the LED at the front side shines red.<br />

When EPC <strong>NET</strong> is additionally connected to an<br />

existing ethernet, the green LED of the LAN<br />

jack shines.<br />

It is necessary that an IP address is allocated<br />

for EPC <strong>NET</strong> in order to switch it via ethernet.<br />

The IP address must belong to the desired<br />

subnetwork.<br />

The allocation can be accomplished automatically<br />

by a DHCP server (see 1.2.1) or<br />

manually. For a manual allocation under<br />

Windows we recommend the program<br />

EPCnet_conf.exe 2(see<br />

1.2.2).<br />

1.2.1 Allocation by DHCP server<br />

If there is a DHCP server available in the<br />

network, an unused IP address will be allocated<br />

automatically each time EPC <strong>NET</strong> is restarted<br />

3.<br />

This option can be disabled (see 3) or<br />

modified by an appropriate configuration of the<br />

DHCP server.<br />

1.2.2 Allocation via Windows software<br />

Start EPC <strong>NET</strong> in boot mode (see 4.1) and open<br />

2<br />

the program EPCnet_conf.exe . The program<br />

will look automatically for connected devices<br />

and will display their IP settings.<br />

If the displayed IP address accords with the<br />

default setting (192.168.0.2), there is either no<br />

DHCP server available in the network or no<br />

unsused IP address could be allocated.<br />

IP settings can be modified manually by using the program<br />

EPCnet_conf.exe.<br />

Enter an unused IP address and the gateway of<br />

the desired subnetwork. Save the changes with<br />

Program Device/ SaveConfig.<br />

After having changed the network settings EPC<br />

3<br />

<strong>NET</strong> must be restarted in normal mode (see<br />

4.1.).<br />

After restart click on Search in order to display<br />

the modified IP settings.<br />

Via the website http://”IP address of EPC <strong>NET</strong>”/ (e.g.<br />

http://192.168.1.221/) EPC <strong>NET</strong> can be switched.<br />

Besides there are the following options:<br />

Config<br />

The settings of EPC <strong>NET</strong> can be configured<br />

here (see 3).<br />

Batchmode<br />

Independently from the current switching<br />

state EPC <strong>NET</strong> can be switched on or<br />

switched off for a selectable delay (1-30<br />

sec. or 1-30 min.)<br />

After the chosen delay EPC <strong>NET</strong> will be<br />

switched off or switched on again automatically.<br />

Via Batchmode EPC <strong>NET</strong> can be switched off and<br />

switched on again automatically .<br />

Logout<br />

Only one user can be logged in at the same<br />

time. After three minutes without activity<br />

there will be an automatical log-out.<br />

EPC <strong>NET</strong> can also be switched automatically<br />

at defined times with the help of the command<br />

line tool EPC_<strong>Control</strong>.pl 2 and a taskplanner.<br />

More informations can be found on our website.


3 CONFIGURATION 4 PRODUCT FEATURES<br />

Settings of EPC <strong>NET</strong> can be changed via the<br />

website http://”IP address of EPC <strong>NET</strong>”/ (e.g.<br />

http://192.168.0.2/).<br />

The modification of name and password will<br />

be applied immediately. To apply the modification<br />

of other settings EPC <strong>NET</strong> has to be<br />

restarted 3.<br />

Label<br />

A name with a maximum of 15 characters<br />

can be allocated here.<br />

IP Settings<br />

IP Settings of EPC <strong>NET</strong> can be modified<br />

here.<br />

TCP/IP settings by DHCP<br />

Each time EPC <strong>NET</strong> is restarted 3 it will be<br />

checked if a DHCP server is available in the<br />

network. In this case IP settings will be<br />

requested and saved. If there is no DHCP<br />

server in the network it is advisable to<br />

disable this option.<br />

After <strong>Power</strong>Up switch<br />

The switching state of EPC <strong>NET</strong> after a<br />

restart 3 can be defined here (on, off, last<br />

state).<br />

Password<br />

A password with a maximum of 15<br />

characters can be allocated here if required.<br />

The user name for the password is ”admin”.<br />

The settings of EPC <strong>NET</strong> can be modified in the configuration<br />

menu.<br />

4.1 OPERATING MODI<br />

EPC <strong>NET</strong> can be started in two ways:<br />

Boot mode<br />

To start EPC <strong>NET</strong> in boot mode, the button<br />

at the back or front side must be pushed for<br />

at least two seconds when restarting 3 EPC<br />

<strong>NET</strong>. While EPC <strong>NET</strong> is in boot mode the<br />

LED at the front side blinks red.<br />

By using the program EPCnet_conf.exe 2 it<br />

is possible to disable the password, to<br />

update the firmware and to restore the<br />

default settings.<br />

In boot mode EPC <strong>NET</strong> is not switched. A<br />

change of the switching state is not possible.<br />

Normal mode<br />

After a restart EPC <strong>NET</strong> is automatically in<br />

normal mode .<br />

In normal mode EPC <strong>NET</strong> can be switched<br />

and configured.<br />

4.2 CHANGING OF SWITCHING STATE<br />

A device that is connected to EPC <strong>NET</strong> can be<br />

turned off and on again automatically by using<br />

the batchmode function (see 2).<br />

The current switching state of EPC <strong>NET</strong> can be<br />

changed by pushing the button at the back or<br />

front side for at least three seconds.<br />

4.3 FIRMWARE UPDATE<br />

In order to update the firmware both the program<br />

EPCnet_conf.exe2 and the latest firmware2<br />

are needed.<br />

Start EPC <strong>NET</strong> in boot mode (see 4.1) and open<br />

2<br />

the program EPCnet_conf.exe . On the left<br />

side of the program window all EPC <strong>NET</strong>s that<br />

are in the network are listed. Select the one that<br />

should be updated and click on Program<br />

Device/ Firmware Update .<br />

4.4 DEFAULT SETTINGS<br />

In order to restore the default settings EPC <strong>NET</strong><br />

must be started in boot mode (see 4.1). Besides<br />

that the program EPCnet_conf.exe2 is needed.<br />

When opening the program all EPC <strong>NET</strong>s that<br />

are in the network will be listed on the left side of<br />

the program window. Select the one of which<br />

settings should be restored and click on<br />

Program Device/Format Eeprom.<br />

Please notice<br />

that all current<br />

settings will be<br />

deleted. When<br />

restarting3<br />

EPC <strong>NET</strong> the<br />

next time the<br />

default settings<br />

will be loaded.<br />

After having restored the default settings EPC<br />

<strong>NET</strong> must be put into operation again (see 1).<br />

4.5 LED<br />

EPC <strong>NET</strong> is not connected to an electric<br />

circuit<br />

EPC <strong>NET</strong> is connected to an electric<br />

circuit and is switched off<br />

EPC <strong>NET</strong> is connected to an electric<br />

circuit and is switched on<br />

If the LED blinks red, EPC <strong>NET</strong> is in boot mode<br />

( see 4.1 ).<br />

4.6 TECHNICAL DATA<br />

Default settings<br />

Name: Exp<strong>Power</strong><strong>Control</strong><br />

IP address: 192.168.0.2<br />

Netmask: 255.255.255.0<br />

Gateway: 192.168.0.0<br />

DHCP: enabled<br />

Password: disabled<br />

After restart: switched off<br />

Network connection: 10MBit 10base T<br />

Ethernet<br />

Protocol: TCP/IP<br />

Switched power: max. 2000W<br />

Switched voltage: 230V<br />

Operating temperature: 0°C-50°C<br />

Product version: EPC <strong>NET</strong><br />

Dimensions (LxWxH): 13,5 x 7,5 x 6,5 cm<br />

Weight: approx. 210g<br />

1<br />

Product version: EPC <strong>NET</strong> IEC<br />

Dimensions (LxWxH): 12,0 x 6,4 x 5,5 cm<br />

Weight: approx. 320g<br />

FAQs<br />

Connection<br />

EPC <strong>NET</strong> is connected but...<br />

...the LED doesn’t shine<br />

Please check the connection to the electric<br />

circuit.<br />

...the green LED of the LAN jack doesn’t<br />

shine<br />

Please check the network connection.<br />

...I can’t open the website<br />

Please assure that both EPC <strong>NET</strong> and your PC<br />

are in the same subnetwork.<br />

Where can I find the IP settings of my subnetwork?<br />

Open the Windows MSDOS command prompt<br />

(Start/Accessories/Comand Prompt and Start/<br />

Programs/MSDOSPrompt respectively) and enter the<br />

command line ipconfig/all.<br />

How can I check if EPC <strong>NET</strong> is connected<br />

properly?<br />

2<br />

Open the program EPCnet_conf.exe and click on<br />

Search. If EPC <strong>NET</strong> is connected properly it will be<br />

displayed in the left part of the program window.<br />

Switching<br />

I can’t log in at EPC <strong>NET</strong>’s website<br />

If the message „Access denied. Used by …“ is<br />

displayed another user is logged in at the moment.<br />

Alternatively check the network connection (green<br />

LED at the LAN jack must shine) and assure that<br />

both EPC <strong>NET</strong> and your PC are in the same<br />

subnetwork.<br />

I forgot my password<br />

Restart EPC <strong>NET</strong> in boot mode and open the<br />

2<br />

program EPCnet_conf.exe . Disable the password<br />

protection and restart EPC <strong>NET</strong> in normal mode.<br />

The switching state doesn’t change when<br />

pushing the button<br />

Restart EPC <strong>NET</strong> in normal mode.<br />

Program EPCnet_conf.exe<br />

The program doesn’t find EPC <strong>NET</strong><br />

Check the connection to the electric circuit (LED at<br />

the front side must shine green or red) and the<br />

network (green LED at the LAN jack must shine).<br />

1 product version EPC <strong>NET</strong> IEC for IEC appliance<br />

connector. Operation is the same as for EPC<br />

<strong>NET</strong>.<br />

2 free download on our website www.gude.info<br />

3 restart means seperate and reconnect EPC <strong>NET</strong>

Hooray! Your file is uploaded and ready to be published.