THE SCHOOL BOARD OF MIAMI-DADE COUNTY, FLORIDA<br />

SCHOOL BOARD ADMINISTRATION BUILDING<br />

1450 Northeast Second Avenue<br />

<strong>Miami</strong>, FL 33132<br />

BIDDER QUALIFICATION FORM<br />

BID NO.<br />

BID TITLE<br />

Direct all inquiries to Procurement Management<br />

Services.<br />

BUYER NAME:<br />

E-MAIL ADDRESS:<br />

PHONE: (305)<br />

FAX NUMBER:<br />

TDD PHONE: (305) 995-2400<br />

Bids will be accepted until 2:00 PM on _________________________ in room 351, School Board Administration Building, 1450 NE 2nd<br />

Avenue, <strong>Miami</strong>, FL 33132, at which time they will be publicly opened. Bids may not be withdrawn for ________ days after opening.<br />

(Refer to Instructions to Bidders, para. IV.B.)<br />

The submission of the bid by the vendor, acceptance and award of the bid by The School Board of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>, Florida, and<br />

subsequent purchase orders issued against said award shall constitute a binding, enforceable contract. Unless otherwise stipulated in the<br />

bid documents, no other contract documents shall be issued.<br />

I.<br />

II.<br />

BIDDER CERTIFICATION AND IDENTIFICATION<br />

A. I certify that this bid is made without prior understanding, agreement, or connection with any corporation, firm, or person<br />

submitting a bid for the same materials, supplies, or equipment, and is in all respects fair and without collusion or fraud. I<br />

agree to abide by all conditions of this bid; and I certify that I am authorized to sign this bid for the bidder.<br />

B. Vendor certifies that it satisfies all necessary legal requirements as an entity to do business with The School Board of<br />

<strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>, Florida.<br />

C. I certify agreement with the School Board of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> Business Code of Ethics, and agree to comply with this<br />

Code and all applicable School Board contracting and procurement policies and procedures. (School Board Rule 6Gx13-<br />

3F-1.025)<br />

INDEMNIFICATION<br />

The Bidder shall hold harmless, indemnify and defend the indemnities (as hereinafter defined) against any claim, action, loss,<br />

damage, injury, liability, cost or expense of whatsoever kind or nature including, but not by way of limitation, attorney's fees and<br />

court costs arising out of bodily injury to persons, including death, or damage to tangible property arising out of or incidental to<br />

the performance of this contract (including goods and services provided thereto) by or on behalf of the Bidder, whether or not<br />

due to or caused in part by the negligence or other culpability of the indemnity, excluding only the sole negligence or culpability<br />

of the indemnity. The following shall be deemed to be indemnities: The School Board of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>, Florida, its<br />

members, officers and employees.<br />

III. PERFORMANCE SECURITY, is required on this bid. YES NO<br />

Refer to INSTRUCTIONS TO BIDDERS, para. VII./IF PERFORMANCE SECURITY IS REQUIRED, PLEASE INDICATE THE<br />

TYPE TO BE FURNISHED:<br />

Performance Bond<br />

Check (Cashier's, Certified, or equal)<br />

An original, manual signature is required on the Bidder Qualification Form.<br />

(Bidder is requested to use blue ink, do not use pencil)<br />

Legal Name of Vendor<br />

Mailing Address<br />

City<br />

Telephone No.<br />

E-mail Address<br />

By: Signature (Original)<br />

Of Authorized Representative<br />

Name (Typed or Printed)<br />

Of Authorized Representative<br />

State<br />

Fax No.<br />

Zip Code<br />

Date<br />

Date<br />

FM-3191 Rev. (08-07)


DISCLOSURE OF EMPLOYMENT OF FORMER SCHOOL BOARD EMPLOYEES<br />

Pursuant to School Board Rule 6Gx13- 3F-1.025, which may be accessed at<br />

http://www2.dadeschools.<strong>net</strong>/schoolboard/rules all bidders, proposers, consultants, and contractors are required<br />

to disclose the names of any of their employees who serve as agents or principals for the bidder, proposer or<br />

contractor, and who within the last two years, have been or are employees of the School Board. Such<br />

disclosures will be in accordance with current School Board rules, but will include, at a minimum, the name of<br />

the former School Board employee, a list of the positions the employee held in the last two years of his or her<br />

employment with the School Board, and the dates the employee held those positions.<br />

NAME LIST OF POSITIONS DATES EMPLOYEE HELD POSITION<br />

FM-3191 Rev. (08-07)


FROM:<br />

AFFIX<br />

POSTAGE<br />

HERE<br />

THE SCHOOL BOARD OF MIAMI-DADE COUNTY, FLORIDA<br />

PROCUREMENT MANAGEMENT SERVICES<br />

ROOM NO. 352 BID BOX<br />

1450 N.E. 2 ND AVENUE<br />

MIAMI, FLORIDA 33132<br />

BID NO.:<br />

BID TITLE:<br />

BID OPENING DATE:


THE SCHOOL BOARD OF MIAMI-DADE COUNTY, FLORIDA<br />

Procurement Management Services<br />

NOTICE OF PROSPECTIVE BIDDERS<br />

NO BID<br />

If not submitting a bid at this time, for informational purpose only, detach this sheet from the<br />

bid documents, complete the information requested, fold as indicated, staple, affix postage<br />

and return address, and mail. NO ENVELOPE IS NECESSARY.<br />

NO BID SUBMITTED FOR REASON(S) CHECKED AND/OR INDICATED:<br />

Our company does not handle this type of product/service.<br />

We cannot meet the specifications nor provide an alternate equal product.<br />

Our company is simply not interested in bidding at this time.<br />

OTHER, (Please specify)<br />

We do not want to be retained on your mailing list for future bids for this type<br />

or product and/or service.<br />

Signature<br />

Title<br />

Company<br />

NOTE:<br />

Failure to respond, either by submitting a bid or this completed form, may result in<br />

your company being removed from the School Board’s bid list. To qualify as a<br />

respondent to the bid, vendor must submit a NO BID.


Vendor Information Sheet<br />

1A.<br />

Or<br />

1B.<br />

Federal Employer Identification Number<br />

Owner's Social Security Number<br />

Name of Firm, Individual(s), Partners or Corporation<br />

Street Address<br />

2. Telephone/Fax/Contact Person<br />

Telephone number<br />

Fax number<br />

__________________________________________<br />

Contact Person<br />

City State Zip Code<br />

E-mail address<br />

3. Ownership Disclosure<br />

If the contract or business transaction is with a corporation, partnership, sole proprietorship,or joint venture, the full legal name<br />

and business address shall be provided for the chief officer, director, or owner who holds, directly or indirectly the majority of the<br />

stock or ownership. If the contract or business transaction is with a trust, the full legal name and address shall be provided for<br />

each trustee and each beneficiary. Post Office addresses are not acceptable.<br />

Name<br />

Title<br />

Address<br />

Gender<br />

Raceethnicity<br />

Stock Ownership<br />

NOTE: The information provided by the vendor on this form should be consistent with that provided on the "Vendor's<br />

Application". All vendors must have a current vendor's application on file with M-DCPS, and have provided information and/or be<br />

familiar with M-DCPS' policy regarding the following: (a) Employment Disclosure, (b) Drug Free Workplace, (c) Family Leave<br />

Policy, (d) Code of Business Ethics, (e) Conflict of Interest, (f) Perception, (g) Gratuities, and (h) Business Meals. Failure to<br />

provide M-DCPS a current vendor application may cause the vendor not to be awarded any new business with M-DCPS.<br />

Vendor applications can be downloaded at: http://procurement.dadeschools.<strong>net</strong>


BID PROPOSAL FORM (FORMAT A)<br />

BID<br />

<strong>008</strong>-<strong>HH11</strong><br />

MIAMI-DADE COUNTY PUBLIC SCHOOLS<br />

TO: THE SCHOOL BOARD OF MIAMI-DADE COUNTY FLORIDA<br />

BUYER<br />

PAGE<br />

Vanessa Y. Gomez<br />

FIRE ALARM SERVICES CONTRACT<br />

SPECIAL CONDITIONS<br />

SC 1<br />

1. PURPOSE: The purpose of this bid is to establish a contract to furnish all necessary labor, transportation,<br />

material and equipment to test, service, inspect, repair and maintain fire alarm systems at the listed locations, in<br />

accordance with the attached specifications. The term of the bid shall be for two (2) years from date of award, and<br />

may, by mutual agreement between <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong> (M-DCPS) and the awardee(s), be<br />

extended for three (3) additional one year periods, and if needed, 90 days beyond the expiration date of the<br />

current contract period. Procurement Management Services, may if considering to extend, request a letter of<br />

intent to extend from the awardee, prior to the end of the current contract period. The awardee(s) will be notified<br />

when the Board has acted upon the recommendation. All prices shall be firm for the term of the contract. The<br />

successful vendor(s) agrees to this condition by signing this bid.<br />

2. AWARD: The School Board of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> may award this service contract, on a total low per group<br />

basis, to qualified companies meeting the specifications contained herein, capable of furnishing all necessary<br />

labor, transportation, material and equipment to test, service, inspect, repair and maintain fire alarm systems at<br />

the listed locations. The bid will be awarded to two (2) responsive and responsible vendors, for each group<br />

(Primary and Alternate), offering the lowest total discounted price per Group. A maximum of two (2) vendors per<br />

Group, meeting all requirements, will be awarded. The bidders are required to respond to all items in a Group to<br />

be considered for award in that Group. If the primary awardee fails to perform under the terms and conditions of<br />

the contract, the Alternate awardee will be contacted.<br />

The awarded vendor’s employees shall provide, install, program and test a Silent Knight 5104(DACT) at those<br />

facilities that do not have fire alarm "UL" listed DACT's installed. The cost of installation shall be included in the<br />

annual maintenance and inspection bid price under the terms and conditions of this contract. Phone lines within<br />

6 ft. of the Fire Alarm Control Panel will be provided by the M-DCPS.<br />

3. PRE-QUALIFICATION: Awarded vendors are not automatically pre-qualified with M-DCPS. Vendors shall, within<br />

six (6) months of award of this bid, be pre-qualified by the School Board of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>, Florida, at a<br />

minimum as Low Voltage Contractor or Alarm Contractor I, in accordance with School Board Rule 6Gx-13-7D-<br />

1.05 and Florida statutes. Failure to obtain pre-qualification status shall preclude the vendor from receiving any<br />

further work under this contract until such status is obtained. Vendors shall maintain pre-qualified status<br />

throughout the remaining term of this contract, and any extensions thereof. Applications and instructions are<br />

available at the following address: http://prequalification.dadeschools.<strong>net</strong>/<br />

4. INSURANCE REQUIREMENTS: Successful vendor(s) are required to have insurance coverage, as specified in<br />

the indemnity and insurance form(s), attached hereto and made a part of this bid. The successful vendor(s) must<br />

submit completed certificate of insurance form(s), before being recommended for award. Failure to submit this<br />

form(s), as noted, will result in the vendor(s) not being recommended for the bid award<br />

5. UL/CSA/ETL APPROVAL: All electrical equipment shall bear the approval symbol or name of Underwriters’<br />

Laboratories, Inc., The Canadian Standards Association or ETL Testing Laboratories.


BID PROPOSAL FORM (FORMAT A)<br />

BID<br />

<strong>008</strong>-<strong>HH11</strong><br />

MIAMI-DADE COUNTY PUBLIC SCHOOLS<br />

TO: THE SCHOOL BOARD OF MIAMI-DADE COUNTY FLORIDA<br />

BUYER<br />

PAGE<br />

Vanessa Y. Gomez<br />

FIRE ALARM SERVICES CONTRACT<br />

SPECIAL CONDITIONS CONTINUED<br />

SC 2<br />

6. CONTRACT COMMENCEMENT: Successful vendor(s) shall be responsible for the first required (quarterly or<br />

annual) inspection and any initial repairs needed to bring the fire alarm systems up to OEM (Original Equipment<br />

Manufacturer) standards based upon the last annual inspection as noted in the documentation attached and no<br />

later than one hundred (100) days after date of award. Vendor shall, within sixty (60) days after issuance of<br />

purchase order by M-DCPS Procurement Management Services, complete all fire alarm services as applicable to<br />

all facilities.<br />

7. PRE-BID CONFERENCE: A pre-bid conference will be held Thursday, January 10, 2<strong>008</strong> at 10:00 a.m. in the<br />

Maintenance Operations Training Room, 12525 NW 28 Avenue, <strong>Miami</strong>, Florida. Pre-Bid Conference attendance<br />

by the bidder or its qualified representative is HIGHLY ENCOURAGED to ensure bid compliance.<br />

8. DELIVERY: Delivery and installation shall be completed within 30 days after receipt of purchase order, or as<br />

otherwise indicated. All deliveries and installation will be made to schools and departments as indicated on each<br />

purchase order.<br />

9. UNAUTHORIZED SHIPMENT/SUBSTITUTION: Unauthorized substitutions and shipments shall be grounds for<br />

termination. Vendors shall be considered in default of the contract and shall lose eligibility to transact new<br />

business with the Board for a period of fourteen (14) months from the date of termination by the Board.<br />

10. WARRANTY: The warranty of equipment, after delivery and acceptance by the school or department, shall be for<br />

one year or manufacturer’s warranty, whichever is greater. The successful vendor will be responsible for repairing<br />

each unit during the warranty period, at no cost to the Board. Vendor agrees to repair and return equipment within<br />

five (5) days from receipt of request or provide a temporary replacement.<br />

11. DEFAULT: In the event of default, which may include, but is not limited to non-performance, poor performance,<br />

and/or non-compliance with warranty repairs the awardee(s) shall lose eligibility to transact new business with<br />

The Board for a period of fourteen (14) months from date of termination by The Board.<br />

12. VENDOR INFORMATION SHEET: All bidders are requested to complete the attached Vendor Information Sheet.<br />

In order to conduct new business under the bid, M-DCPS requires that the vendor(s) have a current vendor<br />

application on file. The information on both documents must be consistent. Failure to comply with this condition<br />

may cause the Bidder(s) not be awarded any new business. Vendor applications can be downloaded at<br />

http://procurement.dadeschools.<strong>net</strong>.


BID PROPOSAL FORM (FORMAT A)<br />

BID<br />

<strong>008</strong>-<strong>HH11</strong><br />

MIAMI-DADE COUNTY PUBLIC SCHOOLS<br />

TO: THE SCHOOL BOARD OF MIAMI-DADE COUNTY FLORIDA<br />

BUYER<br />

PAGE<br />

Vanessa Y. Gomez<br />

FIRE ALARM SERVICES CONTRACT<br />

SPECIAL CONDITIONS CONTINUED<br />

SC 3<br />

13. OCCUPATIONAL LICENSE: Any person, firm, corporation or joint venture, with a business location in <strong>Miami</strong>-<br />

<strong>Dade</strong> <strong>County</strong>, Florida, which is submitting a bid, shall meet the <strong>County</strong>’s Occupational License Tax requirements<br />

in accordance with Chapter 8A, Article IX of the Code of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>, Florida. Bidders with a location<br />

outside <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> shall meet their local Occupational Tax requirements. A copy of the license is<br />

requested to be submitted with the Bid Proposal. If the Bidder has already complied with this requirement, a new<br />

copy is not required while the license is valid and in effect. It is the Bidder’s responsibility to resubmit a copy of a<br />

new license after expiration or termination of the current license. Non-compliance with this condition may cause<br />

the bid not to be considered for award.<br />

14. BID SUBMITTALS: Bidders are requested to submit one original and one (1) copy of their bid. Bidders are<br />

required to submit, with their bid package, or within five (5) days of request, all information requested in the<br />

attached specifications. Failure to submit the following documentation may result in the bid not to be considered<br />

for award.<br />

Requested information includes, but is not limited to:<br />

• Signed Bidders Qualification Form<br />

• Bid Proposal Form Price Sheets<br />

• Vendor Information Sheet<br />

• Occupational License<br />

• A list of technicians that will be servicing MDCPS fire alarm systems and a copy of each technician’s<br />

qualifications and training certificates as defined in Specification 1.4A3<br />

• Insurance Documentation<br />

• Two (2) letters of reference as defined in 1.4 A4, of the attached Specifications<br />

• List of emergency telephone numbers and twenty-four (24) hour contact number as per Specification 1.4A5<br />

• Fire Protection System Contractor I or II Certificate as defined in Specification 1.3A<br />

15. BIDDERS RESPONSIBILITY: Each bidder(s) shall carefully examine the Instructions To Bidders, Specifications,<br />

Special Conditions as listed, and the list of schools to be served. It shall be the responsibility of the bidder to be<br />

fully informed as to the bid details and the number and wide spread locations of schools.<br />

16. NEW EQUIPMENT: This bid shall be for new equipment only. Newly manufactured containing used or rebuilt<br />

parts, remanufactured, rebuilt, reconditioned, newly re-manufactured, used; shopworn, demonstrator or prototype<br />

equipment is not acceptable and will be rejected.<br />

17. NON-EXCLUSIVITY: M-DCPS reserves the right to procure items herein described through the use of contracts<br />

awarded by the State of Florida, any county or municipality, or other authorized contract, whichever is considered<br />

in the best interest of M-DCPS.


BID PROPOSAL FORM (FORMAT A)<br />

BID<br />

<strong>008</strong>-<strong>HH11</strong><br />

MIAMI-DADE COUNTY PUBLIC SCHOOLS<br />

TO: THE SCHOOL BOARD OF MIAMI-DADE COUNTY FLORIDA<br />

BUYER<br />

PAGE<br />

Vanessa Y. Gomez<br />

FIRE ALARM SERVICES CONTRACT<br />

SPECIAL CONDITIONS CONTINUED<br />

SC 4<br />

18. ESTIMATED QUANTITIES: No guarantee is expressed or implied, as to the amount of projects that will be<br />

awarded during the contract period. The School Board of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>, Florida is not obligated to utilize<br />

these services, subsequent to the award of this bid.<br />

19. CODES AND PERMITS: All work performed and materials used shall comply with all applicable federal, state and<br />

local codes, laws, ordinances and regulations. The successful vendor(s) shall be responsible for all necessary<br />

licenses and permits, as may be required.<br />

20. INVOICING: Invoices are requested to contain the purchase order number, contract number, quantity, unit<br />

description, quote number (if applicable) and price. Any deviation from this requirement may be grounds for<br />

termination of the contract. Vendor may be requested to provide electronic submission of invoices in a format to<br />

be determined by the District.<br />

21. BID ADDENDUMS OR QUESTIONS AND ANSWERS: All bidders should monitor continuously, the M-DCPS<br />

Procurement website, for any addendums or questions and answers that may be posted, prior to the opening of<br />

this solicitation. The procurement website, which lists all bids, addendums, questions and answers and award<br />

information, is as follows: http://procurement.dadeschools.<strong>net</strong> (then click on) Current Bids/RFP's Under the<br />

Cone of Silence.<br />

22. CONE OF SILENCE: A Cone of Silence is applicable to this competitive solicitation. Any inquiry, clarification, or<br />

information regarding this bid must be requested, in writing, by FAX or E-mail to:<br />

A COPY OF THIS WRITTEN REQUEST MUST BE SENT SIMULTANEOUSLY TO:<br />

Vanessa Y. Gomez, Buyer<br />

Ileana Martinez, School Board Clerk<br />

Procurement Management Services<br />

<strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

<strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

1450 N.E. 2 ND Avenue, Room 268B<br />

1450 N.E. 2 ND Avenue, Room 352 <strong>Miami</strong>, Florida 33132<br />

<strong>Miami</strong>, Florida 33132 Fax #305-995-1448<br />

Fax #305-523-2331<br />

E-Mail: martinez@dadeschools.<strong>net</strong><br />

E-Mail: vygomez@dadeschools.<strong>net</strong><br />

DEADLINE FOR ANY INQUIRY, CLARIFICATION, OR INFORMATION REGARDING THIS BID IS ONE<br />

WEEK PRIOR TO DUE DATE TO ALLOW MDCPS SUFFICIENT TIME TO ADDRESS ALL INQUIRIES.


BID PROPOSAL FORM (FORMAT A)<br />

BID<br />

<strong>008</strong>-<strong>HH11</strong><br />

MIAMI-DADE COUNTY PUBLIC SCHOOLS<br />

TO: THE SCHOOL BOARD OF MIAMI-DADE COUNTY FLORIDA<br />

BUYER<br />

PAGE<br />

Vanessa Y. Gomez<br />

FIRE ALARM SERVICES CONTRACT<br />

SPECIAL CONDITIONS CONTINUED<br />

SC 5<br />

23. ERASURES OR CORRECTIONS: When filling out the Bid Proposal Form, bidders are required to complete bid<br />

proposal in ink.<br />

1. Use of pencil is prohibited.<br />

2. Do not erase or use correction fluid to correct an error.<br />

3. All changes must be crossed out and initialed in ink.<br />

Those bids for individual items that do not comply with items 1, 2 and 3 above will be considered non-responsive<br />

for that item(s).


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

PART 1 - GENERAL<br />

1.0 PURPOSE:<br />

A. It is the intent of this contract to maintain fully operational and trouble free fire alarm<br />

systems at all times in compliance with the Florida Building Code, NFPA 72 and State<br />

Fire Marshal (SFM) 4A-48. This contract shall secure firm prices for the term of the<br />

contract for preventive maintenance, emergency on-site service response, required<br />

inspections, repairs, materials, labor, training, and written reports of fire alarm systems<br />

and associated accessories as specified hereunder. All services performed by the vendor<br />

shall comply with the requirements of the references listed under Paragraph 1.2, unless<br />

otherwise specifically addressed by this contract.<br />

1.1 DEFINITIONS:<br />

A. Fire Alarm Service Contract: This service contract is an agreement between the fire<br />

alarm service vendor and <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong> (MDCPS) for the vendor<br />

to provide required inspections and maintenance. The service contract shall state the<br />

facilities covered and the main fire alarm system manufacturer name and model number.<br />

This is a full service contract, inclusive of required inspections, preventive maintenance,<br />

on site service response, software upgrades, repairs, emergency services, materials, parts,<br />

labor, training and written documentation for each system's main panel and any and all<br />

sub-panels and connected fire alarm devices, regardless of manufacturer.<br />

B. MDCPS/OWNER: <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong>.<br />

C. Facility: All building structures at a single location which are designated as a school, an<br />

administrative or ancillary site.<br />

D. MDCPS Authorized Representative: The MDCPS authorized representative shall be<br />

the District Alarm Coordinator III, or designee.<br />

E. Vendor: Vendor shall be the contractor or service company awarded this contract.<br />

F. OEM: Original Equipment Manufacturer<br />

G. Qualified Personnel: Shall be fire alarm technicians possessing a current <strong>Miami</strong>-<strong>Dade</strong><br />

or Broward <strong>County</strong> Certificate of Competency as an Electrical Master/Journeyperson or<br />

an Electrical Specialty Master/Journeyperson in the Fire Alarm Category, or meeting one<br />

of the following criteria:<br />

1. Factory trained and certified by the factory, the local OEM or the factory<br />

authorized distributor;<br />

2. National Institute for Certification in Engineering Technologies Fire Alarm<br />

Certified Level II, or higher;<br />

3. Certified by the Office of the State Fire Marshal or the local authority having<br />

jurisdiction;<br />

4. Trained and qualified personnel employed by an organization listed by a national<br />

testing laboratory for the servicing of fire alarm systems.<br />

1 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

5. Certified by the Florida State Department of Professional Regulation in the Fire<br />

Alarm trade.<br />

H. Full-time Employees: Qualified personnel employed by the vendor and working for said<br />

vendor a minimum of thirty-five (35) hours per week.<br />

I. Required Inspection: Any and all inspections performed by qualified personnel that<br />

fulfill the requirements of SFM 4A-48 and NFPA 72 (or latest Edition).<br />

J. School Board: The Board of elected officials that is directly responsible to the public for<br />

the enforcement of all policies and procedures for <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong>.<br />

K. Contract Effective Date: As determined by the Board Award.<br />

L. Final Acceptance : Shall mean Additional Services work that has been fully<br />

commissioned, inspected and approved by Maintenance Operations and as having been<br />

completed in accordance with the defined scope of work, design drawings and punch list,<br />

and shall include receipt of all required training, manuals, drawings, warranties, and, if<br />

required, releases of lien and claim.<br />

M. Sub-contractor: A Subcontractor is a person or entity other than a material man or<br />

laborer who enters into a subcontract with the vendor for the performance of any part of<br />

the vendor's work.<br />

N. Additional Services: Services not specifically stated in Sections 3.0 and 3.1 of these<br />

specifications.<br />

O. Qualifier: The person who possesses a license as a State Certified Electrical Contractor<br />

(EC license), or State Certified Alarm Contractor, EF or EY license, per FS 489, Part II.<br />

P. Site Administrator: The senior administrator, or designee, at the facility where services<br />

are being provided.<br />

Q. Troubleshoot & Diagnostics: As stated in this contract, is the act of servicing any<br />

contracted or non-contracted fire alarm components during a service call to facilitate a<br />

repair.<br />

R. Written Notice: The delivery of a certified or registered letter, facsimile or E-Mail<br />

transmission (with confirmation notice). The delivery of the certified or registered letter<br />

to the last known business address shall constitute proper notice to the vendor. Unless<br />

otherwise specified, all communications, including but not limited to instructions,<br />

permissions, proposals, quotes, and any clarifications thereof, between MDCPS and the<br />

vendor shall be in writing.<br />

S. Sub-panel: A fire alarm control panel which is subordinate to the main panel, which<br />

may or may not be interfaced with the main panel, and may or may not be located in the<br />

immediate vicinity of the main panel. Sub-panels are not necessarily of the same<br />

manufacture as the main panel and protect only a portion of the facility.<br />

2 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

T. Functional System: A status or condition of the fire alarm system that assures that the<br />

facility is protected for early warning fire alert. The fire alarm system must be operational<br />

and be capable of activating audible and visual notification for evacuation. Trouble<br />

conditions may not render the system non-functional as long as activation of any fire<br />

alarm device assures that all personnel within the facility are notified to evacuate.<br />

U. Emergency Service: Immediate response by the vendor to a situation or occurrence of a<br />

serious nature that develops due to system failure, power loss, acts of nature or any life<br />

threatening situation for building occupancy, or as declared by the MDCPS authorized<br />

representative.<br />

V. Urgent Service: Response by the vendor to a situation or occurrence of a less serious<br />

nature, which does not result in a substantially impaired system or in any life threatening<br />

situation but does require maintenance and/or repair.<br />

1.2 REFERENCES:<br />

A. Florida Building Code (FBC) and associated codes and standards referenced therein.<br />

Latest Edition<br />

B. Chapter 489, Part II, Florida Statutes<br />

C. State Fire Marshal Rule (SFM) 4A-48; Fire Safety Standards<br />

D. MDCPS Master Specification Guidelines Section 16721 - Fire Alarm Detection Systems<br />

E. Occupational Safety and Health Act (OSHA)<br />

F. National Fire Protection Association 72 (NFPA); National Fire Alarm Code<br />

G. National Fire Protection Association 70 (NFPA); National Electrical Code (NEC)<br />

H. American Society for Testing and Material (ASTM)<br />

I. Americans with Disabilities Act <strong>Public</strong> Law 101-336 (ADA)<br />

J. Florida Accessibility Code for Building Construction - Latest Edition<br />

K. Underwriters Laboratories (UL)<br />

NOTE: Where conflicting specifications exist between reference documents or any specifications<br />

contained herein, the more restrictive specification will prevail.<br />

1.3 VENDOR QUALIFICATIONS AND REQUIREMENTS:<br />

A. The vendor shall be licensed as a State Certified Electrical Contractor, EC or State<br />

Certified Alarm Contractor, EF or State Registered Alarm Contractor I, EY, per FS 489<br />

Part II. Any change in the vendor’s license, qualifier or qualified personnel status shall be<br />

reported in writing to the MDCPS authorized representative within five (5) working days<br />

of its occurrence.<br />

3 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

B. Throughout the term of this contract the vendor shall maintain a licensed qualifier who<br />

shall be a full time employee.<br />

C. Fire alarm technicians provided by the vendor shall be qualified personnel as defined in<br />

Paragraph 1.1, G, Definitions. Technicians' certification, qualifications and training shall<br />

be for the type of systems being serviced. The vendor’s alarm technicians shall be fulltime<br />

employees, unless the technicians are employees of a MDCPS approved<br />

subcontractor.<br />

D. Vendor shall maintain offices, facilities, and personnel within the State of Florida.<br />

Vendor shall be accessible by a local (toll free in <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>) telephone call<br />

during regular business hours. Local answering service for emergencies shall be available<br />

twenty-four (24) hours a day, seven (7) days per week.<br />

E. Vendor shall possess, or have immediate access to, all necessary tools, repair parts,<br />

materials, ladders/scaffolding and test equipment needed to meet the service requirements<br />

for the awarded fire alarm systems.<br />

F. Throughout the duration of this contract, the vendor shall possess, or have immediate<br />

access to all OEM registered software and additional programming services for<br />

addressable systems. NOTE: MDCPS does not have access to OEM software and<br />

programming pass codes.<br />

G. Subcontracting for Base and Additional Services is allowed, only with prior written<br />

approval from the MDCPS authorized representative. The vendor shall be held fully<br />

responsible and liable for the supervision and performance of all work performed by<br />

subcontractors. MDCPS shall not be responsible for resolution of disputes between the<br />

vendor and any subcontractor. MDCPS reserves the right to reject any subcontractor.<br />

Rejection of any subcontractor shall not entitle the vendor to adjustment of bid prices.<br />

H. All vendor's personnel, including any subcontractor and subcontractor’s employees<br />

engaged in installing, repairing and testing fire alarm components within MDCPS<br />

facilities shall meet the requirements of Paragraph 1.1, G, of this document.<br />

I. The vendor is required, and shall have the capability, to simultaneously perform all work<br />

described herein at multiple locations throughout <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> on a timely basis.<br />

J. All personnel employed by the vendor, including any subcontractor and subcontractor’s<br />

employees when applicable, shall display at all times an identification badge which shall<br />

include the employee’s name, the employer’s name and either a physical description or a<br />

photograph of the employee. Employees without proper identification shall not be<br />

permitted to work on MDCPS property.<br />

K. The vendor’s employees, subcontractors and its employees, and any other personnel,<br />

including material suppliers- engaged in any activities encompassed by this term bid are<br />

strictly forbidden from participating in any manner and form of interaction with students<br />

of <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong>. Violation of this provision may result in removal<br />

of the individual(s) involved from the school site, the project, and further, the vendor may<br />

be prohibited from employing the individual in any future work with MDCPS performed<br />

under this term bid.<br />

4 of 21


1.4 REQUIRED BID DOCUMENTATION:<br />

<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

A. At time of bidding, vendors shall submit copies of the following Licenses. Failure to<br />

provide the required documentation may result in the bid not being considered for award.<br />

1. Vendor’s Occupational License.<br />

2. Vendor’s Qualifier (Vendor’s or Contractor's) License.<br />

3. A list of the technicians that will be servicing MDCPS fire alarm systems and a<br />

copy of each technician's qualifications and training certificates.<br />

4. Two (2) letters of reference from service contract customers where work similar<br />

in scope has been performed for a period not less than two (2) years. These<br />

references shall be from customers with multiple facilities, similar to those of<br />

MDCPS, where the vendor has provided services defined in this solicitation.<br />

MDCPS shall not be used as a reference.<br />

5. List of emergency telephone numbers and twenty-four (24) hour answering<br />

service.<br />

C. All documents supplied must meet with the approval of the MDCPS’ Procurement<br />

Management Services and the MDCPS authorized representative before the vendor is<br />

recommended for award.<br />

D. Bid price of each listed location shall include:<br />

1. All repairs necessary to bring each awarded system to OEM operational<br />

standards, including the repair of any and all pre-existing conditions, with the<br />

exception of any systems which are being upgraded, renovated or replaced as<br />

part of ongoing projects as of the date of bid award. This provision does not<br />

require the vendor to bring systems into compliance with current code as part of<br />

the base bid.<br />

2. All repairs and materials necessary to maintain the condition and operation of the<br />

covered equipment at OEM standards.<br />

3. Any and all services required to maintain the equipment in proper operating<br />

condition throughout the life of this contract.<br />

4. Any and all resources necessary for the vendor to complete the next required<br />

inspection after bid award for each system within the time frame and schedule as<br />

provided by MDCPS with this bid solicitation.<br />

1.5 SITE INVESTIGATIONS:<br />

A. It is strongly recommended that prospective vendors make site inspections at listed<br />

facilities to familiarize themselves with the unique environment where the work is to take<br />

place. Failure to consider the problems, safety considerations, or other conditions unique<br />

to the MDCPS facilities shall not entitle the vendor to additional compensation after bid<br />

award.<br />

5 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

B. The vendor shall be responsible for the inspection of the fire alarm equipment prior to the<br />

submittal of their bid. Bid price shall take into account the condition of the system and<br />

the costs associated with insuring that the system is fully operational within OEM<br />

standards.<br />

1.6 MDCPS RESERVES THE RIGHT:<br />

A. At its sole option, to repair, replace, alter, and/or retrofit systems. The MDCPS<br />

authorized representative shall notify the vendor, via written notice of any repairs,<br />

replacements, alterations, and/or retrofits made by MDCPS, or its agents.<br />

B. At its sole option, to adjust the fire alarm service contract for any single facility, when<br />

any fire alarm system covered under this contract is replaced, and/or new construction or<br />

modifications increases or decreases the number of system devices.<br />

C. In the event that MDCPS chooses, at its sole discretion, to add functional fire alarm<br />

systems to this contract, the vendor shall provide all labor, materials, OEM software, pass<br />

codes and equipment necessary to test, service, inspect and maintain the system(s) in<br />

accordance with these specifications. The cost of such services shall be entered in the<br />

appropriate line item on the Bid Proposal Form.<br />

D. MDCPS may, as it deems necessary, require the vendor to provide supporting<br />

documentation for any submission.<br />

E. MDCPS shall have access to all vendor’s records relating to awarded group(s) including<br />

hard copy as well as electronic records for a period of two years after expiration of the<br />

contract. The vendor, upon execution of the contract shall grant MDCPS unrestricted<br />

access to such records during normal working hours.<br />

F. MDCPS after award may, at its sole discretion, chose to service any facility in an<br />

awarded group in-house as part of the base contract. MDCPS may also chose to return<br />

said facility/facilities back to the awarded vendor for continuation of servicing, at any<br />

point in time. Should MDCPS make such decision(s) a notification from the MDCPS<br />

Authorized Representative will be sent to the awarded vendor for that facility.<br />

1.7 QUALITY ASSURANCE:<br />

A. System Failure:<br />

1. Should any of the vendor’s activities result in a fire alarm system failure, the<br />

vendor shall immediately inform the MDCPS authorized representative via<br />

telephone of the failure and anticipated length of down-time, and shall, within 24<br />

hours of this notification, provide written notice of same.<br />

2. The vendor shall make every effort to expedite repairs and minimize down-time.<br />

3. If the system failure is a result of negligence on the part of the vendor, MDCPS<br />

shall provide temporary equivalent protection pursuant to NFPA 101, and the<br />

vendor shall be responsible for all associated costs.<br />

6 of 21


B. Vendor Accessibility:<br />

<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

Vendor shall be accessible by a local telephone call, toll free in <strong>Miami</strong>-<strong>Dade</strong> <strong>County</strong>,<br />

during regular business hours. Local answering service for emergencies shall be available<br />

twenty-four (24) hours a day, seven (7) days per week.<br />

C. Training:<br />

1. Training classes covering system user operation shall be conducted by the vendor<br />

if requested by the MDCPS authorized representative. Attendees shall be<br />

determined by individual site administrators.<br />

2. If such training is conducted, documentation of the training shall be provided by<br />

the vendor indicating the name of the trainer and the trainer's qualifications, the<br />

date of the training and a list of attendees. This documentation shall be placed in<br />

the system record log book and a copy forwarded to the MDCPS authorized<br />

representative.<br />

D. System Condition:<br />

1. Any time services are provided, the vendor shall ensure that the fire alarm<br />

systems are left in an operable condition. The vendor shall document all<br />

performed services in the facility system record log book.<br />

2. At the conclusion of each inspection or service, the vendor shall insure that the<br />

fire alarm system is properly tagged in accordance with SFM 4A-48.<br />

3. At the conclusion of each inspection, all identified deficiencies shall be<br />

immediately repaired in compliance with Paragraph 3.1 (A).<br />

E. Stoppage of work:<br />

MDCPS reserves the right to stop work on any project if, in the opinion of the MDCPS<br />

authorized representative or the Inspector;<br />

1. Materials or work are not in conformance with the specifications, applicable<br />

codes, standards, specifications and/or accepted practices.<br />

2. The vendor’s activities results in damage to District Property.<br />

3. The vendor’s activities interfere with the normal operation of the facility or its<br />

program.<br />

4. Vendor’s personnel are not properly licensed.<br />

5. Any other condition, situation, or circumstance which, in the opinion of the<br />

MDCPS authorized representative or Inspector, would be a detriment to the best<br />

interests of the District if allowed to persist.<br />

7 of 21


F. Inspection of Work:<br />

1.8 PERMITS:<br />

<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

MDCPS reserves the right to inspect the vendor’s work at any time to assure compliance<br />

with all terms and conditions of the contract. All work will be inspected pursuant to<br />

applicable codes as referenced within this document. If applicable, the vendor will<br />

provide MDCPS with a written request for inspection at least forty-eight (48) hours prior<br />

to the requested inspection date. Vendor will have personnel present during the scheduled<br />

inspections.<br />

This work will be generally accomplished under the auspices of the Annual Maintenance Permit<br />

issued to each facility. The vendor shall not be responsible for obtaining this Permit. However, a<br />

specific building permit will be required for any category of work administered and supervised by<br />

any MDCPS department other than Maintenance Operations and certain projects defined by the<br />

Florida Building Code.<br />

1.9 PERFORMANCE SECURITY:<br />

Vendors shall not be required to submit performance security in order to be initially awarded a<br />

service contract under this solicitation. However, in the event that the value of an individual<br />

project meets the criteria specified in Florida Statute 255.05, and reflected by MDCPS Board<br />

Rule 6Gx13-3C-1.08, the vendor awarded the project shall provide performance security for that<br />

project in the amount and manner established in the INSTRUCTIONS TO BIDDERS.<br />

1.10 SUFFERANCE:<br />

A. Failure by MDCPS to invoke of any of its rights under this contract shall not constitute a<br />

waiver of these rights nor prevent their exercise.<br />

B. Exercise of any sanction provided for in this contract shall not preclude the District from<br />

pursuing remedies available through law, rule or any other provision of this contract.<br />

PART 2 - PRODUCTS<br />

2.0 PARTS:<br />

A. All parts and materials provided under this agreement shall be new, purchased from the<br />

OEM, free from defects, suitable for the intended use and warranted for a minimum of<br />

one year. Use of used or non-OEM parts must be approved by MDCPS authorized<br />

representative, in writing, prior to installation.<br />

B. All non-OEM parts and/or assemblies deemed non-repairable or defective shall be<br />

replaced with parts or assemblies that are OEM approved. Replacement of all<br />

components shall be with other components of equal or better quality, as determined and<br />

accepted by the MDCPS authorized representative. All materials and parts shall be UL<br />

listed for their intended purpose.<br />

8 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

2.1 MANUALS:<br />

Vendor must have in its possession, as applicable, the manufacturer's user, installation,<br />

programming and operation manuals for the fire alarm systems being serviced. Upon request, one<br />

copy per contract period of any document shall be provided to MDCPS at no cost.<br />

2.2 PROGRAMS AND PASSCODES FOR ADDRESSABLE SYSTEMS:<br />

A. At the completion of the first inspection under this contract, the vendor shall download<br />

two (2) copies of the fire alarm system program onto an electronic format accessible and<br />

available to MDCPS. The vendor shall also print copies of the system program. The<br />

vendor shall submit to MDCPS District Alarms two (2) printed copies of the system<br />

program and one electronic format copy containing the latest fire alarm system program.<br />

B. During the term of the contract, the vendor shall maintain copies of the system programs<br />

and a current copy of the latest printout.<br />

C. During the term of the contract, if any modifications are made for additions or deletions<br />

to the fire alarm system exceeding three or more devices, the vendor shall comply with<br />

paragraphs A and B, above.<br />

D. Before submittal to MDCPS, the vendor shall label the documentation (printed hard copy<br />

and electronic format, such as CD or DVD) with the facility name, the user level and<br />

programming pass codes and the date.<br />

E. Invoices for inspections or any other services will not be processed until the vendor<br />

complies with the provisions of this Section.<br />

PART 3 - EXECUTION<br />

3.0 REQUIRED SERVICES COVERED BY THE BASE BID OF THIS CONTRACT:<br />

A. The vendor shall furnish all labor (including troubleshooting and diagnostics), materials,<br />

and equipment necessary to provide complete service and maintenance of all main<br />

panels, sub-panels and associated components of each fire alarm system specified under<br />

this contract including, but not limited to the following:<br />

1. Required fire alarm inspection and maintenance that conforms to NFPA 72<br />

(latest edition), SFM Rule 4A-48 and NFPA 70 (NEC).<br />

2. All services and repairs in strict accordance with the manufacturer's<br />

specifications and guidelines.<br />

3. MDCPS Master Specification Guidelines Section 16721, Fire Alarm Detection<br />

Systems.<br />

9 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

3.1 INSPECTIONS AND MAINTENANCE COVERED BY THE BASE BID OF THIS<br />

CONTRACT:<br />

A. The vendor shall, service, repair or replace if necessary, all wiring, interface devices, pull<br />

station covers, batteries, remote annunciators, printers, relays, switches, smoke detectors,<br />

heat detectors, audibles, strobes, pull stations, lamps, duct detectors, duct detector<br />

housings, connectors, DACT (dialers) and/or any component not mentioned herein but<br />

necessary for the functioning and operation of all fire alarm systems and their associated<br />

components according to manufacturer's specifications, NFPA 72 and MDCPS Master<br />

Specification Guidelines Section 16721, Fire Alarm Detection Systems. All<br />

repairs/replacements are to be completed within twenty-four (24) hours of completion of<br />

the inspection. If repairs are not completed within this time period, the vendor shall<br />

immediately notify the MDCPS authorized representative, in writing, stating the reason<br />

for the delay and establishing a completion date. Failure to comply shall be evidence of<br />

vendor negligence, and may result in penalties and sanctions, including, but not limited to<br />

termination of the contract.<br />

B. The vendor shall provide, at no cost to MDCPS, any software program changes for<br />

addition or deletion of devices during the course of this contract installed or deleted by<br />

the vendor or MDCPS which were required as a result of vendor negligence, error or<br />

omission.<br />

C. The vendor shall provide and install all current software upgrades published by the OEM<br />

during the contract period. Such upgrades must be compatible with existing and any new<br />

peripheral devices.<br />

D. Vendor shall provide and maintain a system record log book for each facility in<br />

accordance with SFM 4A-48 and NFPA 72, 7-5.1. The vendor is responsible for ensuring<br />

that the log book is maintained in a secure location and is also responsible for<br />

replacement of the log book, and all data recorded therein, should the original become<br />

unavailable for any reason. Log books and their contents present at the site shall be<br />

incorporated into any new log book provided by the vendor. Documents shall be<br />

maintained in the log book for eighteen months. Aged records and documents shall be<br />

transmitted to MDCPS to be archived.<br />

E. Prior to use, the vendor's service repair and inspection forms and system record log book<br />

shall be approved by the MDCPS authorized representative. The vendor shall submit one<br />

of each to the MDCPS authorized representative for review and approval.<br />

F. All repairs, including parts used, shall be documented on the approved service forms,<br />

immediately appended in the Log Book, and a copy shall be submitted to the MDCPS<br />

authorized representative within five (5) work days after work completion.<br />

G. For inspections and testing, the vendor shall utilize the NFPA 72 Inspection and Testing<br />

Form from Chapter 7, Figure 7-5.1. All inspections shall be documented on the approved<br />

inspection forms, and shall be submitted to the MDCPS authorized representative within<br />

five (5) work days after work completion. For annual inspections, in addition to the<br />

required entries on the inspection form, the vendor shall also submit the printout of all<br />

system test results (for facilities having printer or printer capability), the system model<br />

number, software revision number, and a list of all mechanical and electrical interface<br />

equipment such as, but not necessarily limited to, elevator controls, gas shutdown, smoke<br />

door releases, sprinkler supervision, etc.<br />

10 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

H. Periodic (quarterly, semi-annual and annual) inspections shall be conducted for each<br />

system covered under this contract. Such inspections shall be conducted no sooner than<br />

eighty (80) days, and no later than one-hundred (100) days apart.<br />

I. Should the vendor exhibit negligence by failing to conduct a required inspection within<br />

the time frame specified in Paragraph 3.1 (H), above, the District will be out of<br />

compliance with code and statute. Therefore, to assure compliance, the cost of two (2)<br />

months service price, as indicated by the vendor in the appropriate line item in the bid<br />

documents, shall be deducted from the vendor's payment for each missed inspection. The<br />

vendor shall also be required to make up the missing inspection immediately, at no cost<br />

to MDCPS. Vendor agrees that it is not necessary for MDCPS to sustain or prove actual<br />

damages in order to assess the foregoing penalties. Two missed inspections at the same<br />

facility during a twelve month period may result in additional sanctions, including<br />

termination of the contract.<br />

J. The vendor shall be responsible for restoring programming which may be lost or<br />

corrupted for any reason. Such reprogramming shall be performed without additional cost<br />

to MDCPS, unless the resident programming was lost through third party intervention or<br />

external force defined in paragraph 3.2 (A). Vendor shall comply with Section 2.2 for<br />

submittals to MDCPS District Alarms.<br />

3.2 SERVICES NOT COVERED BY THE BASE BID OF THIS CONTRACT:<br />

A. Repair to fire alarm system due to external forces such as lightning, flood or other natural<br />

disaster, vandalism, or owner errors. Power fluctuations are not considered external<br />

forces unless the fluctuations verifiably exceed the capabilities of built-in protection<br />

devices of the equipment.<br />

B. MDCPS shall not pay for damages due to transients (lightning) unless substantiated and<br />

verified by the owner's visual inspection, or an OEM repair center, or an independent<br />

testing laboratory.<br />

C. Maintenance and repairs to any equipment, auxiliary equipment, or controls outside of<br />

the fire alarm system area, unless specifically noted in this contract.<br />

D. Maintenance and repair for controls related to Energy Management System, HVAC high<br />

voltage control relays, switches, or low voltage contactors.<br />

E. Inspection, testing, repair or replacement of water flow and tamper valve devices,<br />

however the vendor is responsible for testing and maintaining the integrity and<br />

connection of all circuits interfacing with flow and tamper valves.<br />

3.3 SERVICE REQUESTS:<br />

A. Calls for service shall be initiated by the MDCPS authorized representative or designee.<br />

Only the MDCPS authorized representative or designee shall be authorized to request<br />

services under this contract.<br />

11 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

B. The vendor shall respond upon oral or written notification, delivered by any means<br />

including facsimile or other electronic medium, from the MDCPS authorized<br />

representative or designee to any service request. This response must result in the arrival<br />

of a fire alarm technician at the affected site within two (2) hours after notification in the<br />

case of an Emergency Service request, or twenty-four (24) hours in the case of an Urgent<br />

Service request. One hour response is required in the case of fire at a facility. Vendor’s<br />

service personnel shall inform the MDCPS authorized representative via telephone upon<br />

arrival on site. The vendor shall complete all repairs within twenty-four (24) hours of<br />

arrival on-site. If repairs are not completed within this time period, the vendor shall<br />

immediately notify the MDCPS authorized representative, in writing, stating the reason<br />

for the delay and establishing a completion date. Failure to comply shall be evidence of<br />

vendor negligence, and may result in penalties and sanctions, including, but not limited to<br />

termination of the contract.<br />

C. Service requests include, but are not limited to, the following:<br />

1) Total system failure;<br />

2) Inability to acknowledge, silence or reset audibles or panel troubles;<br />

3) Failure of air conditioning to reset after an alarm;<br />

4) Failure of fire alarm system to communicate with the MDCPS monitoring center;<br />

5) Loss of backup battery power;<br />

6) Damage caused to system due to transients and power surges;<br />

7) Complete zone or loop failure;<br />

8) Vandalism to any part of the system;<br />

9) Fire at a facility;<br />

10) Failure of the elevator recall to reset after an alarm;<br />

11) Trouble condition on the system;<br />

12) Any condition which prevents proper functioning of the system.<br />

D. The vendor is required to respond, as required, twenty-four (24) hours a day, seven (7)<br />

days a week, including holidays, at no additional cost to MDCPS.<br />

E. Failure to respond to MDCPS service requests within the stipulated time frames shall be<br />

considered negligence and may constitute grounds for termination of this contract, or<br />

other sanctions.<br />

F. If a service call is initiated by MDCPS, and the technician arrives on site after the owner<br />

has corrected the situation, the vendor shall be entitled to a service fee not to exceed two<br />

(2) hour’s labor at the rate as stipulated on the BID PROPOSAL FORM. Transient<br />

problems which are not documented owner errors, and which self correct prior to arrival<br />

of a technician, are not billable under any provision in this contract.<br />

G. Upon completion of a service call, vendor shall fax or e-mail a copy of the signed service<br />

ticket by the end of that business day. This service ticket shall contain the Control<br />

Number, or equivalent, from the MDCPS E-Mail Service Request. The vendor may not<br />

be paid for service calls which are not documented as described in this section.<br />

12 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

3.4 PERIPHERAL DEVICE REPLACEMENT AND MISCELLANEOUS REPAIRS:<br />

A. Repair or replacement of certain standard peripheral devices may be necessary. Devices<br />

which have failed due to age, wear, or any non-documentable reason, shall be replaced by<br />

the vendor as part of the base bid. Those which have been vandalized or are inoperable<br />

due to accident, natural occurrences or owner negligence shall be replaced at owner<br />

expense applying the following procedure:<br />

1. If during the course of a periodic inspection or service, the vendor discovers<br />

inoperative device(s), the vendor shall immediately notify the MDCPS<br />

authorized representative and provide details concerning the quantities and types<br />

of devices, which are inoperative. The burden of proof shall lie with the vendor<br />

who shall provide documentation that the failure of the devices was due to<br />

vandalism or other circumstances not covered under the monthly service. The<br />

MDCPS authorized representative shall verify the quantities and types of devices<br />

and that the devices are inoperative for the reasons specified. Following such<br />

verification, immediate repair/replacement of same shall be authorized. The<br />

vendor shall invoice MDCPS for the replaced devices at the line item price(s)<br />

submitted in the bid documents. The vendor shall perform any miscellaneous<br />

repairs required as a result of vandalism, etc., including, but not limited to pull<br />

station reset and reinstalling devices which are pulled from their fixtures.<br />

3.5 ADDITIONAL SERVICES:<br />

A. If requested by MDCPS, the vendor shall be required to perform additional services,<br />

including, but not limited to, repair, installation and/or expansion of fire alarm systems in<br />

any of its facilities. Work performed shall comply with OEM Manufacturers’ standards<br />

and with the requirements of the references listed under Paragraph 1.2 of these<br />

specifications.<br />

B. Labor rates for additional services shall be as follows:<br />

1. Rate for qualified alarm technicians shall not exceed $75.00 per hour. Vendor<br />

shall note its established labor rate on the bid proposal forms.<br />

2. The rate for the installation of miscellaneous material shall not exceed $65.00 per<br />

hour. Vendor shall note its established labor rate on the bid proposal forms.<br />

C. Material cost for additional services shall be as follows:<br />

1. Fire alarm products:<br />

a. The vendor shall bid a minimum of 30% off the most recent OEM<br />

published list price. At no cost to MDCPS, the vendor shall supply the<br />

MDCPS authorized representative with manufacturer's most recent OEM<br />

published price list. Vendor shall note the established discount<br />

percentage off the published price list on the bid proposal forms.<br />

b. Vendor shall complete and submit Form A, attached, for all additional<br />

service quotes.<br />

13 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

2. Miscellaneous Materials Not in Contract (N.I.C)<br />

a. MDCPS reserves the right to obtain quotations from the awarded<br />

vendor(s), or other approved vendors, for miscellaneous materials, which<br />

shall include but not be limited to raceway, connectors, couplers,<br />

fasteners, boxes, cable and wiring.<br />

b. Vendor shall complete and submit Form B, attached, for all quotations<br />

where miscellaneous materials are required.<br />

D. Proposals for additional services (Form A and Form B) shall be submitted to the MDCPS<br />

authorized representative within five (5) working days of being requested.<br />

3.6 DESIGN/DRAWING REQUIREMENTS:<br />

A. If it is determined by the MDCPS authorized representative that signed and sealed<br />

drawings by a Florida Registered design professional are required for any work under this<br />

contract, such shall be considered incidental to the work, and shall be provided by the<br />

vendor. The requirement for these services shall be made a part of the scope of work<br />

identified in Section 3.5, (A) and the cost shall be included with Forms A and B.<br />

1. Said services shall include, but not be limited to, the provision of all design and<br />

construction documents as specified, calculations, shop drawings, record<br />

drawings, and submittals. All design and construction documents, calculations,<br />

shop drawings, and record drawings may be required to be signed and sealed by a<br />

design professional. The vendor, through a responsible design professional, shall<br />

also provide, if necessary, the executed forms, studies, and other documentation<br />

required by applicable codes and agencies having jurisdiction.<br />

2. The vendor shall make any corrections required by the MDCPS authorized<br />

representative and/or design professional and shall resubmit the required number<br />

of corrected copies until approved. The vendor shall direct specific attention in<br />

writing or on resubmitted documents to revisions other than the corrections<br />

requested by the MDCPS authorized representative on previous submission(s).<br />

The District shall not be liable for any parts or materials ordered by the vendor<br />

prior to approval of design documents.<br />

3. All drawings and specifications produced by the design professional(s) shall<br />

become the property of the Board at the completion of the work. The vendor<br />

shall provide four (4) sets of prints and technical specifications; two (2) of these<br />

sets must be signed and sealed.<br />

B. The vendor shall submit the name, address and current Florida registration for all design<br />

professionals for each proposal which requires design services. The Board reserves the<br />

right to approve or disapprove the design professional. If disapproved, the vendor shall be<br />

required to provide an alternate.<br />

C. For projects which the Board provides design documents, the vendor shall review the<br />

plans and identify any discrepancies, inconsistencies, mistakes, etc. prior to preparation<br />

of a cost proposal. Prior to commencement of construction, the vendor shall verify<br />

measurements in the field, and identify any differences from the furnished drawings.<br />

14 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

D. For projects which do not require signed and sealed documents, the vendor shall furnish<br />

shop drawings, record drawings, and any other documents and/or information as may be<br />

required in support of the work. The Board reserves the right to approve all drawings and<br />

submittals.<br />

E. Shop Drawings<br />

1. The vendor shall review, approve and submit six (6) sets of all shop drawings<br />

and samples required for the work. Shop drawings and samples shall be<br />

identified as specified, or as required by the MDCPS authorized representative.<br />

At the time of submission, the vendor shall inform the MDCPS authorized<br />

representative, in writing, of any deviation of the shop drawings or samples from<br />

the requirements of the project scope.<br />

2. The vendor shall make any corrections required by the MDCPS authorized<br />

representative and/or design professional and shall resubmit the required number<br />

of corrected copies of shop drawings or new samples until approved. The vendor<br />

shall direct specific attention in writing or on resubmitted shop drawings to<br />

revisions other than the corrections requested by the MDCPS authorized<br />

representative on previous submission(s).<br />

3. No portion of the work requiring a shop drawing or sample submission shall<br />

commence, nor shall the District be liable for any parts or materials ordered by<br />

the vendor until the submission has been approved. All such portions of the work<br />

shall be in accordance with approved shop drawings and samples.<br />

F. Upon completion of the work and final acceptance by MDCPS, The vendor shall furnish:<br />

PART 4 - WARRANTY<br />

1. Three (3) sets of reproducible record drawings and technical specifications. One<br />

set shall be on Mylar, and the remaining copies shall be blue line or bond. All<br />

copies shall be stamped “AS BUILT”.<br />

2. Three (3) copies of maintenance and operating manuals for any equipment<br />

included in the scope of work and supplied by the vendor.<br />

MDCPS reserves the right to withhold final payment, or any portion thereof, until receipt<br />

of these documents.<br />

A. The vendor shall warrant the work and shall remedy any defects due to faulty materials or<br />

workmanship for a minimum of one (1) year from the date of final acceptance.<br />

Manufacturer’s warranties, if greater than one (1) year, shall not be limited by this<br />

provision.<br />

B. Vendor shall remedy any work which fails to conform to the requirements of the contract<br />

and which appears during the progress of the work. All work, material and hardware<br />

shall be free from defects and shall be structurally and operationally sound during the<br />

entire warranty period. Upon written notice, the vendor shall remedy any defects due<br />

thereto and pay all expenses for any damage to other work resulting there from. Unless<br />

otherwise specified, warranty repairs shall be corrected immediately upon receipt of the<br />

written notice.<br />

15 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

C. Neither the final payment nor any provision in the contract documents shall relieve the<br />

vendor of the responsibility for negligence, defects of manufacture, latent defects, faulty<br />

materials and/or workmanship to the extent of, and within the period provided by law.<br />

PART 5 - NON-EXCLUSIVITY<br />

MDCPS reserves the right to perform, or cause to be performed, the work and services herein<br />

described in any manner it sees fit, including, but not limited to, awarding of other contracts, or to<br />

perform the work with its own employees.<br />

PART 6 - NEGLIGENCE, REMEDY AND TERMINATION<br />

A. MDCPS reserves the right to terminate this contract in its entirety, upon 30 days written<br />

notice to the vendor.<br />

B. MDCPS reserves the right to cancel this contract, or any portion of the work performed<br />

under this contract and default the vendor if material or procedures are used other than<br />

those specified.<br />

C. As a result of vendor negligence, should a system covered under this contract remain<br />

inoperative or exhibit any trouble condition for more than twenty-four (24) hours after<br />

notification to the vendor and issuance of appropriate direction to repair said system,<br />

MDCPS shall effect any and all actions necessary to assure the safety of the building<br />

occupants and security of the physical plant, including, but not limited to temporary<br />

equivalent protection pursuant to NFPA 101 with all associated costs being borne by the<br />

vendor.<br />

D. In the event that the vendor fails to perform any of the services in a satisfactory manner<br />

and in compliance with the terms and conditions of this contract, MDCPS shall notify the<br />

vendor, in writing, of the deficiencies, and establish a specific time frame for correction<br />

of such deficiencies. If correction is not effected in an acceptable manner within the<br />

allocated time, MDCPS shall effect any and all actions necessary to assure the safety of<br />

the building occupants and security of the physical plant, with all associated costs being<br />

borne by the vendor. MDCPS may invoke any other sanctions or penalties including<br />

recommending to the Board that the vendor be declared in default.<br />

E. Any fines and/or penalties levied against the owner by any agency or individual of<br />

jurisdiction which are a result of the vendor’s negligence in adherence to the terms and<br />

conditions of this contract, individual work order, purchase order, applicable statutes,<br />

codes and/or ordinances, shall be borne solely by the vendor.<br />

PART 7 - FACILITY USE, CLEAN UP AND PROTECTION:<br />

A. The vendor shall conform to all applicable OSHA, state and local regulations while<br />

performing work under this contract, and shall take all necessary, ordinary and<br />

extraordinary precautions to provide a safe work environment at all times for the<br />

occupants of the school and the general public in and around the work area. The vendor<br />

shall also ensure that MDCPS property is protected from damage and defacement<br />

resulting from the vendor’s activities. Any such damage shall be corrected by the vendor<br />

at the vendor’s sole expense. Prior to payment of the final invoice, all corrections shall<br />

be inspected and accepted by the MDCPS authorized representative.<br />

16 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

B. It is the responsibility of the vendor to keep the site free from trash, debris, excess<br />

materials, tools and hazardous conditions at all times. The vendor shall be responsible for<br />

disposal of all waste material, and shall do so in conformance with applicable laws, codes<br />

and ordinances.<br />

C. Vendor, its employees and/or assigns, shall not use MDCPS restroom, cafeteria, lounge,<br />

dumpsters, equipment, etc. without permission prior to commencement of project from<br />

the MDCPS authorized representative.<br />

D. Vendor's materials, equipment and tools which are not in use shall be stored in a secured<br />

location supplied by the vendor and approved by MDCPS.<br />

E. MDCPS is not responsible for loss of tools, equipment or supplies.<br />

F. Site shall be left in a “broom clean” condition upon completion of work.<br />

G. Vendor shall not block exits, hallways, corridors, driveways, delivery areas, nor impede<br />

ingress or egress.<br />

H. Vendor shall not impede nor interfere with the normal function of the facility, its<br />

occupants or its programs.<br />

PART 8 - INVOICING AND PAYMENT<br />

A. Invoice and Payment for Base Services<br />

1. All invoices shall include the following:<br />

a. Work location where services were rendered<br />

b. Period of service<br />

c. District’s purchase order number<br />

2. All invoices for provided services shall be submitted for payment within five (5)<br />

work days after the end of the quarter. Invoice amount shall be in conformance<br />

with the terms as described on individual purchase orders. Original invoices shall<br />

be sent to:<br />

MIAMI-DADE COUNTY PUBLIC SCHOOLS<br />

MAINTENANCE AND OPERATIONS<br />

ATTN: DISTRICT ALARMS ADMINISTRATOR<br />

12525 N.W. 28th Avenue<br />

MIAMI, FLORIDA 33167<br />

B. Invoice and Payment for Additional Services:<br />

1. Vendor shall invoice additional services based on the actual labor hours<br />

expended and materials utilized. MDCPS does not pay for travel time. Invoices<br />

for Additional Services shall be sent to the MDCPS Maintenance Operations<br />

Satellite requesting the work.<br />

17 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

2. The invoice document shall contain the following information:<br />

a. District’s purchase order number<br />

b. Description of work<br />

c. Start date and completion date<br />

d. Work location where services were rendered<br />

e. OEM part number and description of materials utilized, quantities and<br />

unit prices<br />

f. Labor hours type, quantities and unit prices<br />

g. Written warranty<br />

h. Final release of lien, and/or consent of surety, from any subcontractor or<br />

supplier, if applicable<br />

i. Final release of claim from the vendor<br />

3. A clean and clearly legible copy of service tickets and/or time sheets shall<br />

document the labor and shall accompany the invoice. This document(s) shall<br />

indicate the technician’s name or ID number, and dates and times services were<br />

provided. Service tickets SHALL be signed at the end of the workday by work<br />

location staff.<br />

C. Invoices not submitted in accordance with the procedures and requirements defined<br />

herein will not be processed for payment and will be returned to the vendor.<br />

D. Payment will only be made for actual installed materials and work performed which has<br />

been inspected and found to be in accordance with the terms and conditions of the<br />

contract. MDCPS will not pay for travel time. Work found to be deficient will be<br />

corrected by the vendor at the vendor’s expense prior to any payment being made. The<br />

vendor will not be compensated for waste and/or surplus materials. The vendor shall not<br />

be paid for any services which have not been authorized by the MDCPS authorized<br />

representative and not accompanied by an MDCPS purchase order.<br />

18 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

19 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

20 of 21


<strong>Miami</strong> <strong>Dade</strong> <strong>County</strong> <strong>Public</strong> <strong>Schools</strong><br />

Bid #<strong>008</strong>-<strong>HH11</strong> – Fire Alarm Services Contract<br />

Specifications<br />

______________________________________________________________________________<br />

END OF SPECIFICATIONS<br />

21 of 21


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 1: Cerberus Pyrotronics Systems<br />

Items 1 through 117 to be awarded on a total low bid basis. Items 118 to 140 will not be used to calculate bid award however, awarded<br />

vendors shall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

1 Angelou, Maya Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

2 Ashe, Bowman Foster Elem. P L C (N) 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

3 Aurburndale Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

4 Beckford, Ethel F./Richmond Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

5 Bell, Paul W. Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

6 Biscayne Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

7 Brentwood Elem. PLC 24 Cerberus Pyrotronics Pyro FS-250 Month $_____________<br />

8 Broad, Ruth K./Bay Harbor Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

9 Brownsville Middle 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

10 Bryan, W. J. Elem. PLC 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

11 C O P E Center North Alternative Education 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

12 Campbell Drive Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

13 Citrus Grove Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

14 Citrus Grove Middle 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

15 Citrus Grove O. T. C. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

16 Cooper, Neva King Educational Center 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

17 Coral Gables Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

18 Coral Reef Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

19 Coral Way Elem / K-8 Center 24 Cerberus Pyrotronics Pyro MXL / FS-250 Month $_____________<br />

20 Crestview Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

21 Doolin, Howard A. Middle 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

22 Douglas, Marjory Stoneman Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

23 Earlington Heights Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

24 Evans, Lillie C. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

25 Eve, Christina M. Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

26 Fascell, Dante B. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

27 Ferguson, John A. Senior 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

28 Flamingo Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

29 Franklin, Benjamin Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

30 Goleman, Barbara Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

31 Good, Joella C. Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

32 Gordon Manatee Elem. PLC (T) 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

33 Gordon, Jack D. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

34 Graham, Bob Educational Center / MLC ( TT ) 24 Cerberus Pyrotronics Pyro MXL-IQ /FS 250 Month $_____________<br />

Page 1 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

35 Graham, Ernest R. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

36 Hadley, Charles R. Elem. PLC (A) 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

37 Hall, Joe Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

38 Hartner, Eneida Massas Elem. 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

39 Hialeah Gardens Elem. / PLC 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

40 Hialeah-<strong>Miami</strong> Lakes Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

41 Hibiscus Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

42 Holmes Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

43 Homestead Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

44 Hoover, Oliver Elem. PLC 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

45 Hopkins, Lindsey Technical 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

46 Hurston, Zora Neale Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

47 Jefferson, Thomas Middle 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

48 Kensington Park Elem./ PLC 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

49 Krop, Dr. Michael M. Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

50 Lake Stevens Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

51 Lake Stevens Middle 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

52 Leewood Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

53 Leisure City K-8 Center / MLC (DD) 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

54 M.A.S.T. Academy/Maritime & Science Technology 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

55 Mann, Jann Opportunity Education 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

56 Martin, Frank C. K-8 Center 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

57 Matthews, Wesley Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

58 Mays Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

59 McMillan, Howard D. Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

60 Meek, Carrie P./Westview Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

61 Melrose Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

62 Merritt, Ada K-8 Center 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

63 <strong>Miami</strong> Beach Senior 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

64 <strong>Miami</strong> Central Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

65 <strong>Miami</strong> Douglas Macaurthur Senior South 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

66 <strong>Miami</strong> Edison Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

67 <strong>Miami</strong> Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

68 <strong>Miami</strong> Shores Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

69 <strong>Miami</strong> Springs Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

70 Mill Branch 24 Cerberus Pyrotronics Pyro System 3 Month $_____________<br />

71 Miller, Phyllis Ruth Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

Page 2 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

72 Morningside Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

73 Moton, Robert Russa Elem. 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

74 Myrtle Grove Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

75 Natural Bridge Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

76 Nautilus Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

77 Norland Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

78 North <strong>County</strong> Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

79 North <strong>Miami</strong> Beach Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

80 O I T Warehouse 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

81 Oak Grove Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

82 Opa Locka Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

83 Palmetto Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

84 Panther, Gordon Elem. PLC (S) 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

85 Porter, Gilbert Elem. PLC (Q) 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

86 Porter, Dr. Gilbert L. Elem. PLC 24 Cerberus Pyrotronics Pyro-MXL-IQ Month $_____________<br />

87 Redland Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

88 Redland Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

89 Redondo Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

90 Reeves, Henry E. S. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

91 Region Maintenance Center I Instructional 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

92 Region Maintenance Center IV Instructional 24 Cerberus Pyrotronics Pyro System 3 Month $_____________<br />

93 Riverside Elem. Clinic 24 Cerberus Pyrotronics Pyro SXL Month $_____________<br />

94 Riviera Middle 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

95 Rockway Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

96 Santa Clara Elem. 24 Cerberus Pyrotronics Pyro MXL-2 Month $_____________<br />

97 Saunders, Laura C. Elem. - Service Bldg. 24 Cerberus Pyrotronics Pyro SXL Month $_____________<br />

98 Scott Lake Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

99 Shenandoah Elem. PLC 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

100 Sheppard, Ben Elem. PLC 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

101 Sibley, Hubert O. Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

102 Skyway Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

103 Smith, John I. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

104 Smith, Lenora B. Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

105 South <strong>Miami</strong> Middle 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

106 South Pointe Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

107 Southwest Center Transportation 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

108 Thomas, Eugenia B. K-8 Center 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

Page 3 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

109 Tropical Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

110 Varela, Felix Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

111 Vehicle Maintenance 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

112 Village Green Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

113 Walters, Mae M. Elem. 24 Cerberus Pyrotronics Pyro MXL-IQ Month $_____________<br />

114 Washington, Booker T. Senior 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

115 Wheatley, Phillis Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

116 Winston Park K-8 Center 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

117 Wyche Jr., Charles David Elem. 24 Cerberus Pyrotronics Pyro MXL Month $_____________<br />

Group 1: Additional Cerberus Pyrotronics Systems<br />

118<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

118A Elementary <strong>Schools</strong> - Cerberus Pyrotronics N/A Month $_____________<br />

118B Primary Learning Centers - Cerberus Pyrotronics N/A Month $_____________<br />

118C Middle <strong>Schools</strong> - Cerberus Pyrotronics N/A Month $_____________<br />

118D Middle Learning Centers - Cerberus Pyrotronics N/A Month $_____________<br />

118E Senior-Vocational Technical <strong>Schools</strong> - Cerberus Pyrotronics N/A Month $_____________<br />

Group 1: Cerberus Pyrotronics Systems Miscellaneous Peripheral Material<br />

119 Addressable Smoke Detector 200 Cerberus Pyrotronics - Each $_____________<br />

120 Addressable Heat Detector 50 Cerberus Pyrotronics - Each $_____________<br />

121 Addressable Manual Station 100 Cerberus Pyrotronics - Each $_____________<br />

122 Non-Addressable Smoke Detector 100 Cerberus Pyrotronics - Each $_____________<br />

123 Non-Addressable Heat Detector 50 Cerberus Pyrotronics - Each $_____________<br />

124 Non-Addressable Manual Station 100 Cerberus Pyrotronics - Each $_____________<br />

125 Protective Cover Manual Station 100 Cerberus Pyrotronics - Each $_____________<br />

126 Protective Cover Horn/Strobe 300 Cerberus Pyrotronics - Each $_____________<br />

127 Visual Strobe 100 Cerberus Pyrotronics - Each $_____________<br />

128 Horn 100 Cerberus Pyrotronics - Each $_____________<br />

129 Horn/Strobe 500 Cerberus Pyrotronics - Each $_____________<br />

130 Mag<strong>net</strong>ic Door Holder 50 Cerberus Pyrotronics - Each $_____________<br />

131 Detector Base Assembly 30 Cerberus Pyrotronics - Each $_____________<br />

132 Black Box Manual Station 25 Cerberus Pyrotronics - Each $_____________<br />

133 Black Box Horn/Strobe 25 Cerberus Pyrotronics - Each $_____________<br />

134 Wire/Cable Indoor 2500 Cerberus Pyrotronics - Each $_____________<br />

135 Wire/Cable Outdoor Wet Location - West Penn 2500 Cerberus Pyrotronics - Each $_____________<br />

136<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Cerberus Pyrotronics - Each<br />

$_____________<br />

Page 4 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

137<br />

138<br />

139<br />

139A<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

Alarm Technician labor rate not to exceed $75.00 per<br />

hour.<br />

360 Cerberus Pyrotronics - Each<br />

360 Cerberus Pyrotronics - Each<br />

Group 1: Cerberus Pyrotronics Systems Labor Rates<br />

- Cerberus Pyrotronics N/A Hour<br />

PRICE PER<br />

MONTH<br />

$_____________<br />

$_____________<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

$_____________<br />

139B Installer labor rate not to exceed $65.00 per hour. - Cerberus Pyrotronics N/A Hour $_____________<br />

Group 1: Percent Discount off List<br />

For additional support functions or modifications to new or existing Cerberus Pyrotronics Fire Alarm Systems OEM parts<br />

140 may be required. Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price _____________ %<br />

list. A minimum of 30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 5 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 2: Simplex Grinnell Systems<br />

Items 141 through 257 to be awarded on a total low bid basis. Items 258 to 280 will not be used to calculate bid award however, awarded<br />

vendors shall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

141 Allapattah Middle 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

142 American Senior 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

143 Arcola Lakes Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

144 Arvida Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

145 Ashe, Dr. Bowman Foster Elem. 24 Simplex Grinnell Simplex 4100 Month $_____________<br />

146 Baker, George T. Aviation 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

147 Bent Tree Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

148 Biscayne Nature Center 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

149 Blanton, Van E. Elem. 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

150 Blue Lakes Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

151 Boussard, Norma Butler Elem. 24 Simplex Grinnell Simplex 4100 U Month $_____________<br />

152 Broadmoor Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

153 Campbell Drive Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

154 Canosa, Jorge Mas Middle 24 Simplex Grinnell Simplex 4100 U Month $_____________<br />

155 Caribbean Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

156 Carol City Middle 24 Simplex Grinnell Simplex 4002-8001 Month $_____________<br />

157 Chiles, Lawton Middle 24 Simplex Grinnell Simpelx 4020 Month $_____________<br />

158 Colonial Drive Elem. 24 Simplex Grinnell Simplex 4004 Month $_____________<br />

159 Coral Park Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

160 Coral Reef Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

161 Coral Terrace Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

162 Corporate Academy North 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

163 Country Club Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

164 Crowder, Thena C. Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

165 Culter Ridge Middle 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

166 Cutler Ridge Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

167 Dario, Rubin Middle 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

168 De Diego, Jose Middle 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

169 Design & Architecture Senior 24 Simplex Grinnell Simplex 4002-8001 Month $_____________<br />

170 Doral Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

171 Dorsey, D. A. Educational Center 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

172 Douglas, Marjory Stoneman Elem. PLC 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

173 Dunbar, Paul Lawrence Elem. 24 Simplex Grinnell Simplex 4020-804 Month $_____________<br />

174 Emerson Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

Page 6 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

175 F. D. L. R. S. at Blue Lakes Elem 24 Simplex Grinnell Simplelx 4100U Month $_____________<br />

176 Fairlawn Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

177 Fairlawn Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

178 Fienberg/Fisher K-8 center 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

179 Filer, Henry H. Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

180 Finlay, Dr. Carlos J. Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

181 Flagler, Henry M. Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

182 Flagmi Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

183 Florida City Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

184 Floyd, Gloria Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

185 Graham, Bob Educational PLC (H) 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

186 Hadley, Charles R. Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

187 Hammocks Middle Addition 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

188 Headstart Transition 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

189 Hialeah Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

190 Howard Drive Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

191 Johnson, J. W. Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

192 Kendale Elem. 24 Simplex Grinnell Simplex 4100U Month $_____________<br />

193 Kennedy, John F. Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

194 Key Biscayne Elem./ K-8 Ctr. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

195 Key Biscayne Nature Center 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

196 Kinloch Park Elem. 24 Simplex Grinnell Simplex 4100 Month $_____________<br />

197 Lehman, William Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

198 Lentin, Linda K-8 Center 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

199 Liberty City Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

200 Lorah Park Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

201 L'ouverture, Toussaint Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

202 Maintenance & Operations 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

203 Mann, Horace Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

204 <strong>Miami</strong> Springs Student Services 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

205 <strong>Miami</strong> Carol City Senior 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

206 <strong>Miami</strong> Gardens Elem. 24 Simplex Grinnell Simplex 4005 Month $_____________<br />

207 <strong>Miami</strong> Heights Elem. 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

208 <strong>Miami</strong> Lakes Educational Center Tech / Sr 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

209 <strong>Miami</strong> Lakes Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

210 <strong>Miami</strong> Norland Senior 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

211 <strong>Miami</strong> Park Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

Page 7 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

212 <strong>Miami</strong> Southridge Senior 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

213 <strong>Miami</strong> Springs Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

214 Naranja Elem. 24 Simplex Grinnell Simplex 4001 Month $_____________<br />

215 Norland Middle 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

216 North Beach Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

217 North <strong>Dade</strong> Middle/ Ctr For Modern Language Elem 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

218 North Hialeah Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

219 North Twin Lakes Elem. 24 Simplex Grinnell Simplex 4100U Month $_____________<br />

220 Norwood Elem. 24 Simplex Grinnell Simplex 4002-8001 Month $_____________<br />

221 Palm Springs North Elem. / PLC (X) 24 Simplex Grinnell Simplex 4020 /4010 Month $_____________<br />

222 Parkway Elem. 24 Simplex Grinnell Simplex 4100 Month $_____________<br />

223 Pepper, Claude Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

224 Pharr, Kelsey L. Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

225 Pine Villa Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

226 Poninciana Parks Elem. 24 Simplex Grinnell Simplex 4002 Month $_____________<br />

227 Porter, Dr. Gilbert L. Elem. 24 Simplex Grinnell Simplex 4100 Month $_____________<br />

228 Region Maintenance Center 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

229 Riverside Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

230 Royal Green Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

231 Royal Palm Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

232 S. B. A. B. 24 Simplex Grinnell Simplex 4100U Month $_____________<br />

233 Saunders, Laura C. Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

234 Schee, John H. Transportation 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

235 Seminole Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

236 Shenandoah Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

237 Sheppard, Ben Elem 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

238 Smith, John I. Elem. PLC 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

239 Snapper Creek Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

240 South <strong>Dade</strong> Middle School 24 Simplex Grinnell Simplex 4100 U Month $_____________<br />

241 South <strong>Dade</strong> Senior 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

242 South Hialeah Elem. 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

243 South <strong>Miami</strong> Heights Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

244 Stirrup, E. W. F. Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

245 Sunset Park Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

246 Sweetwater Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

247 Thomas, W. R. Middle 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

248 Treasure Island Elem. 24 Simplex Grinnell Simplex 4100 Month $_____________<br />

249 Tucker, Frances S. Elem. 24 Simplex Grinnell Simplex 4020-8001 Month $_____________<br />

Page 8 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

PRICE PER<br />

MONTH<br />

250 Turner, William H. Technical / <strong>Miami</strong> Agricultural Ctr. 24 Simplex Grinnell Simplex 4100 U Month $_____________<br />

251 Twin Lakes Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

252 W. L. R. N. Channel 17 24 Simplex Grinnell Simplex 4010 Month $_____________<br />

253 West <strong>Miami</strong> Middle 24 Simplex Grinnell Simplex 4005 Month $_____________<br />

254 Whigham, Dr. Edward L. Elem 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

255 Whigham, Dr. Edward L. Elem. PLC 24 Simplex Grinnell Simplex 4100-8001 Month $_____________<br />

256 Whispering Pines Elem. 24 Simplex Grinnell Simplex 4020 Month $_____________<br />

257 Young, Nathan B. Elem. 24 Simplex Grinnell Simplex 4002 Month $_____________<br />

GROUP 2: Additional Simplex Grinnell Systems<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

258 systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

258A Elementary <strong>Schools</strong> - Simplex Grinnell N/A Month $_____________<br />

258B Primary Learning Centers - Simplex Grinnell N/A Month $_____________<br />

258C Middle <strong>Schools</strong> - Simplex Grinnell N/A Month $_____________<br />

258D Middle Learning Centers - Simplex Grinnell N/A Month $_____________<br />

258E Senior-Vocational Technical <strong>Schools</strong> - Simplex Grinnell N/A Month $_____________<br />

GROUP 2: Simplex Grinnell Systems Miscellaneous Peripheral Material<br />

259 Addressable Smoke Detector 200 Simplex Grinnell - Each $_____________<br />

260 Addressable Heat Detector 50 Simplex Grinnell - Each $_____________<br />

261 Addressable Manual Station 100 Simplex Grinnell - Each $_____________<br />

262 Non-Addressable Smoke Detector 100 Simplex Grinnell - Each $_____________<br />

263 Non-Addressable Heat Detector 50 Simplex Grinnell - Each $_____________<br />

264 Non-Addressable Manual Station 100 Simplex Grinnell - Each $_____________<br />

265 Protective Cover Manual Station 100 Simplex Grinnell - Each $_____________<br />

266 Protective Cover Horn/Strobe 300 Simplex Grinnell - Each $_____________<br />

267 Visual Strobe 100 Simplex Grinnell - Each $_____________<br />

268 Horn 100 Simplex Grinnell - Each $_____________<br />

269 Horn/Strobe 500 Simplex Grinnell - Each $_____________<br />

270 Mag<strong>net</strong>ic Door Holder 50 Simplex Grinnell - Each $_____________<br />

271 Detector Base Assembly 30 Simplex Grinnell - Each $_____________<br />

272 Black Box Manual Station 25 Simplex Grinnell - Each $_____________<br />

273 Black Box Horn/Strobe 25 Simplex Grinnell - Each $_____________<br />

274 Wire/Cable Indoor 2500 Simplex Grinnell - Each $_____________<br />

275 Wire/Cable Outdoor Wet Location - West Penn 2500 Simplex Grinnell - Each $_____________<br />

276<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Simplex Grinnell - Each<br />

$_____________<br />

277<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

360 Simplex Grinnell - Each<br />

$_____________<br />

Page 9 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

278<br />

279<br />

279A<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

Alarm Technician labor rate not to exceed $75.00 per<br />

hour.<br />

PRICE PER<br />

MONTH<br />

360 Simplex Grinnell - Each $_____________<br />

GROUP 2: Simplex Grinnell Systems Labor Rates<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

- Simplex Grinnell N/A Hour<br />

$_____________<br />

279B Installer labor rate not to exceed $65.00 per hour. - Simplex Grinnell N/A Hour $_____________<br />

Group 2: Percent Discount off List<br />

For additional support functions or modifications to new or existing Simplex Grinnell Fire Alarm Systems OEM parts may<br />

280 be required. Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price list. _____________ %<br />

A minimum of 30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 10 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 3: Edwards Systems<br />

Items 281 through 319 to be awarded on a total low bid basis. Items 320 to 342 will not be used to calculate bid award however, awarded<br />

vendors shall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

281 Boone, Virginia A./Highland Oaks Elem. 24 Edwards Edwards IRC 3 Month $_____________<br />

282 Calusa Elem. 24 Edwards Edwards EST 2 Month $_____________<br />

283 Carol City Elem. 24 Edwards Edwards EST 2 Month $_____________<br />

284 Carver, George Washington Elem. 24 Edwards ECI 7100 Month $_____________<br />

285 Cenntennial Middle 24 Edwards Edwards EST 3 Month $_____________<br />

286 Curry, Lamar Louise Middle 24 Edwards Edwards EST-2 Month $_____________<br />

287 Edison Park Elem. 24 Edwards Edwards IRC-3 Month $_____________<br />

288 Greenglade Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

289 Hawkins, Barbara Elem. 24 Edwards Edwards IRC-3 Month $_____________<br />

290 Homestead Senior 24 Edwards Edwards IRC-3 Month $_____________<br />

291 Hoover, Oliver Elem. 24 Edwards Edwards IRC 3 Month $_____________<br />

292 Kruse, Ruth Owens Educational Center 24 Edwards Edwards 5721B Month $_____________<br />

293 Lawrence Jr., David K-8 Center 24 Edwards Edwards EST-2 Month $_____________<br />

294 Ludlam Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

295 Mack, Dr. Henry W./West Little River Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

296 Merrick Educational Center 24 Edwards Edwards 5721 B Month $_____________<br />

297 <strong>Miami</strong> Douglas Macaurthur Senior North 24 Edwards Edwards IRC 3 Month $_____________<br />

298 <strong>Miami</strong> Edison Senior 24 Edwards Edwards EST 3 Month $_____________<br />

299 <strong>Miami</strong> Jackson Senior 24 Edwards Edwards EST 3 Month $_____________<br />

300 <strong>Miami</strong> Northwestern Senior 24 Edwards Edwards IRC 3 Month $_____________<br />

301 <strong>Miami</strong> Springs Senior 24 Edwards Edwrads IRC 3 Month $_____________<br />

302 North Center Transportation 24 Edwards Edwards EST-29234 Month $_____________<br />

303 Northeast Center Transportation 24 Edwards Edwards EST-QSC Month $_____________<br />

304 Olinda Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

305 Orchard Villa Elem. 24 Edwards Edwards 5721B Month $_____________<br />

306 Parkview Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

307 Perrine Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

308 Pine Lake Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

309 Reagan, Ronald W./Doral Senior 24 Edwards Edwards EST-3 Month $_____________<br />

310 Renick, Robert Educational Center 24 Edwards Edwards EST-2 Month $_____________<br />

311 S B A B - Jefferson Administration Building 24 Edwards Edwards IRC 3 Month $_____________<br />

312 S B A B - Jefferson Garage 24 Edwards Edwards EST 2Z6 Month $_____________<br />

313 Shadowlawn Elem. 24 Edwards Edwards IRC 3 Month $_____________<br />

314 South <strong>Miami</strong> K-8 Center 24 Edwards Edwards EST-2 Month $_____________<br />

Page 11 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

PRICE PER<br />

MONTH<br />

315 Southside Elem. 24 Edwards Edwards IRC 3 Month $_____________<br />

316 Southwood Middle 24 Edwards Edwards EST 3 Month $_____________<br />

317 Vineland Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

318 West Homestead Elem. 24 Edwards Edwards EST-2 Month $_____________<br />

319 Westview Middle 24 Edwards Edwards EST-2 Month $_____________<br />

Group 3: Additional Edwards Systems<br />

320<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

320A Elementary <strong>Schools</strong> - Edwards N/A Month $_____________<br />

320B Primary Learning Centers - Edwards N/A Month $_____________<br />

320C Middle <strong>Schools</strong> - Edwards N/A Month $_____________<br />

320D Middle Learning Centers - Edwards N/A Month $_____________<br />

320E Senior-Vocational Technical <strong>Schools</strong> - Edwards N/A Month $_____________<br />

Group 3: Edwards Systems Miscellaneous Peripheral Material<br />

321 Addressable Smoke Detector 200 Edwards - Each $_____________<br />

322 Addressable Heat Detector 50 Edwards - Each $_____________<br />

323 Addressable Manual Station 100 Edwards - Each $_____________<br />

324 Non-Addressable Smoke Detector 100 Edwards - Each $_____________<br />

325 Non-Addressable Heat Detector 50 Edwards - Each $_____________<br />

326 Non-Addressable Manual Station 100 Edwards - Each $_____________<br />

327 Protective Cover Manual Station 100 Edwards - Each $_____________<br />

328 Protective Cover Horn/Strobe 300 Edwards - Each $_____________<br />

329 Visual Strobe 100 Edwards - Each $_____________<br />

330 Horn 100 Edwards - Each $_____________<br />

331 Horn/Strobe 500 Edwards - Each $_____________<br />

332 Mag<strong>net</strong>ic Door Holder 50 Edwards - Each $_____________<br />

333 Detector Base Assembly 30 Edwards - Each $_____________<br />

334 Black Box Manual Station 25 Edwards - Each $_____________<br />

335 Black Box Horn/Strobe 25 Edwards - Each $_____________<br />

336 Wire/Cable Indoor 2500 Edwards - Each $_____________<br />

337 Wire/Cable Outdoor Wet Location - West Penn 2500 Edwards - Each $_____________<br />

338<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Edwards - Each<br />

$_____________<br />

339<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

360 Edwards - Each<br />

$_____________<br />

340<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

360 Edwards - Each $_____________<br />

Group 3: Edwards Systems Labor Rates<br />

Page 12 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

341<br />

341A<br />

Alarm Technician labor rate not to exceed $65.00 per<br />

hour.<br />

- Edwards N/A Hour<br />

PRICE PER<br />

MONTH<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

$_____________<br />

341B Installer labor rate not to exceed $55.00 per hour. - Edwards N/A Hour $_____________<br />

Group 3: Percent Discount off List<br />

For additional support functions or modifications to new or existing Edwards Fire Alarm Systems OEM parts may be<br />

342 required. Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price list. A _____________ %<br />

minimum of 30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 13 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 4: Notifier Systems<br />

Items 343 through 385 to be awarded on a total low bid basis. Items 386 to 408 will not be used to calculate bid award however, awarded<br />

vendors shall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

343 Air Base Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

344 Ammons, Herbert A. Middle 24 Notifier Notifier AFP-400 Month $_____________<br />

345 Avocado Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

346 Beckham, Ethel Koger Elem. 24 Notifier Notifier AM 2020 Month $_____________<br />

347 Bel-Aire Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

348 Biscayne Gardens Elem. 24 Notifier Notifier AM 2020 Month $_____________<br />

349 Braddock, G. Holmes Senior 24 Notifier Notifier AFP 1010 Month $_____________<br />

350 Bright, James H. Elem. 24 Notifier Notifier AFP-400 Month $_____________<br />

351 Bryan, W. J. Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

352 C O P E Center South/Wallace,Dorothy M. 24 Notifier Notifier AFP 1010 Month $_____________<br />

353 Central East Transportation & Gas 24 Notifier Notifier AFP-200 Month $_____________<br />

354 Chapman, William Elem. 24 Notifier Notifier AFP -400 Month $_____________<br />

355 Dupuis, John G. Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

356 Earhart, Amelia Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

357 Food and Nutrition Building 2 24 Notifier Notifier AFP-200 Month $_____________<br />

358 Gulfstream Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

359 Hammocks Middle 24 Notifier Notifier 5000 Month $_____________<br />

360 Hialeah Middle 24 Notifier Notifier AM 2020 Month $_____________<br />

361 Hiighland Oaks Middle 24 Notifier Notifier AFP 1010 Month $_____________<br />

362 Kendale Lakes Elem. 24 Notifier Notifier AFP-400 Month $_____________<br />

363 Lakeview Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

364 Little River Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

365 Materials Mgmt. Central Stockroom 24 Notifier Notifier AFP-200 Month $_____________<br />

366 <strong>Miami</strong> Coral Park Senior 24 Notifier Notifier AM 2020 Month $_____________<br />

367 <strong>Miami</strong> Douglas MacArthur South Kitchen 24 Notifier Notifier AFP-200 Month $_____________<br />

368 <strong>Miami</strong> Palmetto Senior 24 Notifier Notifier AFP 1010 Month $_____________<br />

369 Morgan, Robert Educational Center Sr. 24 Notifier Notifier ONXY NFS-640 Month $_____________<br />

370 North <strong>Miami</strong> Senior 24 Notifier Notifier AFP 1010 Month $_____________<br />

371 Olympia Heights Elem. 24 Notifier Noitifier AFP 1010 Month $_____________<br />

372 Palm Lakes Elem. 24 Notifier Notifier AFP-400 Month $_____________<br />

373 Palm Springs Elem. 24 Notifier Notifier AM 200 Month $_____________<br />

374 Palm Springs Middle 24 Notifier Notifier AM 2020 Month $_____________<br />

375 Palmetto Middle 24 Notifier Notifier AFP 1010 Month $_____________<br />

376 Parkway Middle 24 Notifier Notifier ONYZ NFS-640 Month $_____________<br />

Page 14 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

377 Peskoe, Irving & Beatrice Elem. 24 Notifier Notifier APF 1010 Month $_____________<br />

378 Pinecrest Elem. 24 Notifier Notifier AFP-400 Month $_____________<br />

379 Region Maintenance Center IV 24 Notifier Notifier AFP-200 Month $_____________<br />

380 Richmond Heights Middle 24 Notifier Notifier AFP 1010 Month $_____________<br />

381 Rockway Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

382 S & D Stores and Mail Distribution 24 Notifier Notifier AFP-200 Month $_____________<br />

383 Sliver Bluff Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

384 Springview Elem. 24 Notifier Notiifier AFP 1010 Month $_____________<br />

385 Sylvania Heights Elem. 24 Notifier Notifier AFP 1010 Month $_____________<br />

Group 4: Additional Notifier Systems<br />

386<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

386A Elementary <strong>Schools</strong> - Notifier N/A Month $_____________<br />

386B Primary Learning Centers - Notifier N/A Month $_____________<br />

386C Middle <strong>Schools</strong> - Notifier N/A Month $_____________<br />

386D Middle Learning Centers - Notifier N/A Month $_____________<br />

386E Senior-Vocational Technical <strong>Schools</strong> - Notifier N/A Month $_____________<br />

Group 4: Notifier Systems Miscellaneous Peripheral Material<br />

387 Addressable Smoke Detector 200 Notifier - Each $_____________<br />

388 Addressable Heat Detector 50 Notifier - Each $_____________<br />

389 Addressable Manual Station 100 Notifier - Each $_____________<br />

390 Non-Addressable Smoke Detector 100 Notifier - Each $_____________<br />

391 Non-Addressable Heat Detector 50 Notifier - Each $_____________<br />

392 Non-Addressable Manual Station 100 Notifier - Each $_____________<br />

393 Protective Cover Manual Station 100 Notifier - Each $_____________<br />

394 Protective Cover Horn/Strobe 300 Notifier - Each $_____________<br />

395 Visual Strobe 100 Notifier - Each $_____________<br />

396 Horn 100 Notifier - Each $_____________<br />

397 Horn/Strobe 500 Notifier - Each $_____________<br />

398 Mag<strong>net</strong>ic Door Holder 50 Notifier - Each $_____________<br />

399 Detector Base Assembly 30 Notifier - Each $_____________<br />

400 Black Box Manual Station 25 Notifier - Each $_____________<br />

401 Black Box Horn/Strobe 25 Notifier - Each $_____________<br />

402 Wire/Cable Indoor 2500 Notifier - Each $_____________<br />

403 Wire/Cable Outdoor Wet Location - West Penn 2500 Notifier - Each $_____________<br />

404<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Notifier - Each<br />

$_____________<br />

Page 15 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

405<br />

406<br />

407<br />

407A<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

Alarm Technician labor rate not to exceed $75.00 per<br />

hour.<br />

360 Notifier - Each<br />

PRICE PER<br />

MONTH<br />

$_____________<br />

360 Notifier - Each $_____________<br />

Group 4: Notifier Systems Labor Rates<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

- Notifier N/A Hour<br />

$_____________<br />

407B Installer labor rate not to exceed $65.00 per hour. - Notifier N/A Hour $_____________<br />

Group 4: Percent Discount off List<br />

For additional support functions or modifications to new or existing Notifier Fire Alarm Systems OEM parts may be<br />

408 required. Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price list. A _____________ %<br />

minimum of 30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 16 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 5: Faraday Systems<br />

Items 409 through 442 to be awarded on a total low bid basis. Items 443 to 465 will not be used to calculate bid award however, awarded<br />

vendors shall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

409 Banyan Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

410 Brentwood Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

411 Bunche Park Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

412 Coconut Grove Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

413 Comstock Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

414 Coral Gables Senior 24 Faraday Faraday MPC 2000 Month $_____________<br />

415 Devon Aire K-8 Center 24 Faraday Faraday MPC 2000A Month $_____________<br />

416 Douglass, Frederick Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

417 Edelman, Gertrude K./Sabal Palm Elem. 24 Faraday Faraday MPC 2000A Month $_____________<br />

418 English Center 24 Faraday Faraday MPC 2000 Month $_____________<br />

419 Fire Prevention Shop 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

420 Fulford Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

421 G. I. U. M-DCPS Police Dept. 24 Faraday Faraday Firewatch ii + 2 Month $_____________<br />

422 Gratigny Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

423 Henry, S./ West Laboratory Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

424 Lee, J. R. E. Educational Center 24 Faraday Faraday MPC 2000 Month $_____________<br />

425 Madison Middle 24 Faraday Faraday MPC 2000 Month $_____________<br />

426 Morgan, Robert Educational Ctr. Tech. / Day Care 24 Faraday<br />

Faraday 400902/Firewatch II +<br />

2<br />

Month $_____________<br />

427 North Glade Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

428 North <strong>Miami</strong> Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

429 North <strong>Miami</strong> Middle 24 Faraday Faraday MPC 2000 Month $_____________<br />

430 Northwest Center Transportation 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

431 O I T/ M I S Technical Training 24 Faraday Faraday ProWatch 4000 Month $_____________<br />

432 Plant Operations 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

433 Police Dept. MDCPS 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

434 Rainbow Park Elem. 24 Faraday Faraday MPC 2000A Month $_____________<br />

435 Redland Learning - Labor Camp 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

436 Region Maintenance Center lll Building #2 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

437 Region Maintenance Center lll Instructional 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

438 South <strong>Dade</strong> Labor Camp 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

439 South <strong>Dade</strong> Skill Center 24 Faraday Faraday 19328/4000 Month $_____________<br />

440 Sunset Elem. 24 Faraday Faraday MPC 2000 Month $_____________<br />

441 The 500 Role Model Academy 24 Faraday Faraday MPC 2000A Month $_____________<br />

442 Troy Academy at Juvenile Justice 24 Faraday Faraday Firewatch ll + 2 Month $_____________<br />

Page 17 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

PRICE PER<br />

MONTH<br />

Group 5: Additional Faraday Systems<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

443 systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

443A Elementary <strong>Schools</strong> - Faraday N/A Month $_____________<br />

443B Primary Learning Centers - Faraday N/A Month $_____________<br />

443C Middle <strong>Schools</strong> - Faraday N/A Month $_____________<br />

443D Middle Learning Centers - Faraday N/A Month $_____________<br />

443E Senior-Vocational Technical <strong>Schools</strong> - Faraday N/A Month $_____________<br />

Group 5: Faraday Miscellaneous Peripheral Material<br />

444 Addressable Smoke Detector 200 Faraday - Each $_____________<br />

445 Addressable Heat Detector 50 Faraday - Each $_____________<br />

446 Addressable Manual Station 100 Faraday - Each $_____________<br />

447 Non-Addressable Smoke Detector 100 Faraday - Each $_____________<br />

448 Non-Addressable Heat Detector 50 Faraday - Each $_____________<br />

449 Non-Addressable Manual Station 100 Faraday - Each $_____________<br />

450 Protective Cover Manual Station 100 Faraday - Each $_____________<br />

451 Protective Cover Horn/Strobe 300 Faraday - Each $_____________<br />

452 Visual Strobe 100 Faraday - Each $_____________<br />

453 Horn 100 Faraday - Each $_____________<br />

454 Horn/Strobe 500 Faraday - Each $_____________<br />

455 Mag<strong>net</strong>ic Door Holder 50 Faraday - Each $_____________<br />

456 Detector Base Assembly 30 Faraday - Each $_____________<br />

457 Black Box Manual Station 25 Faraday - Each $_____________<br />

458 Black Box Horn/Strobe 25 Faraday - Each $_____________<br />

459 Wire/Cable Indoor 2500 Faraday - Each $_____________<br />

460 Wire/Cable Outdoor Wet Location - West Penn 2500 Faraday - Each $_____________<br />

461<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Faraday - Each<br />

$_____________<br />

462<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

360 Faraday - Each<br />

$_____________<br />

463<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

360 Faraday - Each $_____________<br />

Group 5: Faraday Systems Labor Rates<br />

464<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

464A Alarm Technician labor rate not to exceed $75.00 per hour. - Faraday N/A Hour $_____________<br />

464B Installer labor rate not to exceed $65.00 per hour. - Faraday N/A Hour $_____________<br />

Group 5: Percent Discount off List<br />

For additional support functions or modifications to new or existing Faraday Fire Alarm Systems OEM parts may be<br />

465 required. Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price list. A _____________ %<br />

minimum of 30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 18 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 6: Two System Locations<br />

Items 466 through 499 to be awarded on a total low bid basis. Items 500 to 522 will not be used to calculate bid award however, awarded<br />

vendors hall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

466 Carver, G. W. Middle MLC (NN) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

467 Carver, George Washington Middle 24 Two Systems Faraday MPC 2000 Month $_____________<br />

468 De Leon, Ponce Middle 24 Two Systems Simplex 4100-8001 Month $_____________<br />

469 De Leon, Ponce Middle MLC (JJ) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

470 Everglades Elem. MLC (BB) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

471 Everglades K-8 Center 24 Two Systems Notifier AFP-400 Month $_____________<br />

472 Greynolds Park Elem. 24 Two Systems Simplex 4020 Month $_____________<br />

473 Greynolds Park Elem. PLC 24 Two Systems Pyro MXL-IQ Month $_____________<br />

474 Hialeah Annex(GGG) Senior 24 Two Systems Edwards EST-2 Month $_____________<br />

475 Hialeah Senior 24 Two Systems Simplex 4002-8001 Month $_____________<br />

476 Ives, Madie Elem. 24 Two Systems Pyro MXL Month $_____________<br />

477 Ives, Madie Elem. PLC (M) 24 Two Systems Simplex 4010 Month $_____________<br />

478 Kenwood Elem. 24 Two Systems Simplex 4020 Month $_____________<br />

479 Kenwood Elem. M L C (CC) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

480 Kinloch Park Elem. MLC (MM) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

481 Kinloch Park Middle 24 Two Systems Notifier AFP 1010 Month $_____________<br />

482 Marti, Jose Middle 24 Two Systems Pyro MXL IQ Month $_____________<br />

483 Marti, Jose Middle Clinic 24 Two Systems Faraday Firewatch ii + 2 Month $_____________<br />

484 <strong>Miami</strong> Killian Senior 24 Two Systems Notifier AFP 1010 Month $_____________<br />

485 <strong>Miami</strong> Killian Senior (New Building) 24 Two Systems Pyro MXL Month $_____________<br />

486 <strong>Miami</strong> Lakes Elem. PLC L 24 Two Systems Simplex 4020-8001 Month $_____________<br />

487 <strong>Miami</strong> Lakes K-8 Center 24 Two Systems Pyro MXL Month $_____________<br />

488 Milam, M. A. K-8 Center 24 Two Systems Notifier APF 1010 Month $_____________<br />

489 Milam, M. A. K-8 Center 24 Two Systems Pyro MXL Month $_____________<br />

490 Ojus Elem. 24 Two Systems Pyro MXL Month $_____________<br />

491 Ojus Elem. (New Building) 24 Two Systems Simplex 4100 Month $_____________<br />

492 Roberts, Jane K-8 Center 24 Two Systems Notifier Month $_____________<br />

493 Roberts, Jane S. Elem. M L C (EE) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

494 Shenandoah Middle 24 Two Systems Notifier AFP 1010 Month $_____________<br />

495 Shenandoah Middle MLC (HH) 24 Two Systems Pyro MXL-IQ Month $_____________<br />

496 South <strong>Miami</strong> Senior 24 Two Systems Pyro MXL Month $_____________<br />

497 South <strong>Miami</strong> Senior (New Building) 24 Two Systems Simplex 4100 Month $_____________<br />

498 Southwest <strong>Miami</strong> Senior 24 Two Systems Edwards EST 3 Month $_____________<br />

499 Southwest <strong>Miami</strong> Senior (New) 24 Two Systems Pyro MXL Month $_____________<br />

Page 19 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

PRICE PER<br />

MONTH<br />

GROUP 6: Additional Two System Locations<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

500 systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

500A Elementary <strong>Schools</strong> - Two Systems N/A Month $_____________<br />

500B Primary Learning Centers - Two Systems N/A Month $_____________<br />

500C Middle <strong>Schools</strong> - Two Systems N/A Month $_____________<br />

500D Middle Learning Centers - Two Systems N/A Month $_____________<br />

500E Senior-Vocational Technical <strong>Schools</strong> - Two Systems N/A Month $_____________<br />

GROUP 6: Two System Locations Miscellaneous Peripheral Material<br />

501 Addressable Smoke Detector 200 Two Systems - Each $_____________<br />

502 Addressable Heat Detector 50 Two Systems - Each $_____________<br />

503 Addressable Manual Station 100 Two Systems - Each $_____________<br />

504 Non-Addressable Smoke Detector 100 Two Systems - Each $_____________<br />

505 Non-Addressable Heat Detector 50 Two Systems - Each $_____________<br />

506 Non-Addressable Manual Station 100 Two Systems - Each $_____________<br />

507 Protective Cover Manual Station 100 Two Systems - Each $_____________<br />

508 Protective Cover Horn/Strobe 300 Two Systems - Each $_____________<br />

509 Visual Strobe 100 Two Systems - Each $_____________<br />

510 Horn 100 Two Systems - Each $_____________<br />

511 Horn/Strobe 500 Two Systems - Each $_____________<br />

512 Mag<strong>net</strong>ic Door Holder 50 Two Systems - Each $_____________<br />

513 Detector Base Assembly 30 Two Systems - Each $_____________<br />

514 Black Box Manual Station 25 Two Systems - Each $_____________<br />

515 Black Box Horn/Strobe 25 Two Systems - Each $_____________<br />

516 Wire/Cable Indoor 2500 Two Systems - Each $_____________<br />

517 Wire/Cable Outdoor Wet Location - West Penn 2500 Two Systems - Each $_____________<br />

518<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Two Systems - Each<br />

$_____________<br />

519<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

360 Two Systems - Each<br />

$_____________<br />

520<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

360 Two Systems - Each $_____________<br />

GROUP 6: Two System Locations Labor Rates<br />

521<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

521A Alarm Technician labor rate not to exceed $75.00 per hour. - Two Systems N/A Hour $_____________<br />

521B Installer labor rate not to exceed $65.00 per hour. - Two Systems N/A Hour $_____________<br />

GROUP 6: Percent Discount off List<br />

For additional support functions or modifications to new or existing Two System Locations OEM parts may be required.<br />

522 Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price list. A minimum of _____________ %<br />

30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 20 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

GROUP 7: Miscellaneous Systems<br />

Items 523 through 540 to be awarded on a total low bid basis. Items 541 to 563 will not be used to calculate bid award however, awarded<br />

vendors hall honor these prices if additional support functions or modifications are requested by M-DCPS. Vendors must bid all items.<br />

523 Carver, George Washington Elem. 24 Misc. Systems FCI 7100 Month $_____________<br />

524 Central West Transportation 24 Misc. Systems Napco MFA6000 Month $_____________<br />

525 Cypress Elem. 24 Misc. Systems FCI 7100 Month $_____________<br />

526 Drew, Charles R. Elem. 24 Misc. Systems FCI E 3 Month $_____________<br />

527 Drew, Charles R. Middle 24 Misc. Systems FCI E 3 Month $_____________<br />

528 Glades Middle 24 Misc. Systems FCI 7200 Month $_____________<br />

529 Golden Glades Elem. 24 Misc. Systems FCI MXL Month $_____________<br />

530 King, Martin Luther Elem. 24 Misc. Systems Silent Knight 5820 Month $_____________<br />

531 Meadowlane Elem. 24 Misc. Systems FCI 7100 Month $_____________<br />

532 <strong>Miami</strong> Sunset Senior 24 Misc. Systems FCI 7100 Month $_____________<br />

533 O I T/ M I S - Computer Center 24 Misc. Systems Gamewell Flex 300 Month $_____________<br />

534 O I T/ M I S - Computer Center 24 Misc. Systems ANSUL Auto Pulse 3000 Month $_____________<br />

535 Region Maintenance Center II Instruction 24 Misc. Systems Thorn Fire Quest 200 Month $_____________<br />

536 Region Maintenance Center V Instructional 24 Misc. Systems Firelite MS-5210 Month $_____________<br />

537 Richmond Heights Middle Mag<strong>net</strong> 24 Misc. Systems Firelite MS-2 Month $_____________<br />

538 Shenandoah Middle 24 Misc. Systems World Electronics WE 2085 Month $_____________<br />

539 South Center Transportation 24 Misc. Systems Napco Magnum 6024 Month $_____________<br />

540 South <strong>Dade</strong> Adult Educational 24 Misc. Systems Silent Knight 5207 Month $_____________<br />

GROUP 7: Additional Miscellaneous System Locations<br />

541<br />

In the event M-DCPS increases the fire alarm systems or number of facilities, and chooses at its sole discretion to add servicing to these<br />

systems, the vendor shall: Provide all labor, materials and equipment necessary to test, service, inspect and maintain additional fire<br />

alarm systems in accordance with the attached specifications.<br />

541A Elementary <strong>Schools</strong> - Misc. Systems N/A Month $_____________<br />

541B Primary Learning Centers - Misc. Systems N/A Month $_____________<br />

541C Middle <strong>Schools</strong> - Misc. Systems N/A Month $_____________<br />

541D Middle Learning Centers - Misc. Systems N/A Month $_____________<br />

541E Senior-Vocational Technical <strong>Schools</strong> - Misc. Systems N/A Month $_____________<br />

GROUP 7: Miscellaneous System Locations, Miscellaneous Peripheral Material<br />

542 Addressable Smoke Detector 200 Misc. Systems - Each $_____________<br />

543 Addressable Heat Detector 50 Misc. Systems - Each $_____________<br />

544 Addressable Manual Station 100 Misc. Systems - Each $_____________<br />

545 Non-Addressable Smoke Detector 100 Misc. Systems - Each $_____________<br />

546 Non-Addressable Heat Detector 50 Misc. Systems - Each $_____________<br />

547 Non-Addressable Manual Station 100 Misc. Systems - Each $_____________<br />

Page 21 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

PRICE PER<br />

MONTH<br />

548 Protective Cover Manual Station 100 Misc. Systems - Each $_____________<br />

549 Protective Cover Horn/Strobe 300 Misc. Systems - Each $_____________<br />

550 Visual Strobe 100 Misc. Systems - Each $_____________<br />

551 Horn 100 Misc. Systems - Each $_____________<br />

552 Horn/Strobe 500 Misc. Systems - Each $_____________<br />

553 Mag<strong>net</strong>ic Door Holder 50 Misc. Systems - Each $_____________<br />

554 Detector Base Assembly 30 Misc. Systems - Each $_____________<br />

555 Black Box Manual Station 25 Misc. Systems - Each $_____________<br />

556 Black Box Horn/Strobe 25 Misc. Systems - Each $_____________<br />

557 Wire/Cable Indoor 2500 Misc. Systems - Each $_____________<br />

558 Wire/Cable Outdoor Wet Location - West Penn 2500 Misc. Systems - Each $_____________<br />

559<br />

Input A/C power surge suppresser, DITEK-DTK-120 HW,<br />

EDCO-HSP121BT-1RU or equal.<br />

75 Misc. Systems - Each<br />

$_____________<br />

560<br />

Initiating Device Circuits (IDC)/Signaling Line Circuits<br />

(SLC) surge suppresser, DITEK-DTK-2LVLPLV, EDCO-PC642,<br />

EDCO series SLCP-30 or equal.<br />

360 Misc. Systems - Each<br />

$_____________<br />

561<br />

Notification Appliance Circuits (NAC) surge suppresser,<br />

DITEK-DTK2LVPLV, EDCO-PHC-043 or equal.<br />

360 Misc. Systems - Each $_____________<br />

562<br />

562A<br />

Alarm Technician labor rate not to exceed $75.00 per<br />

hour.<br />

GROUP 7: Miscellaneous System Locations Labor Rates<br />

Provide additional support functions or modifications to new or existing systems that may be requested by M-DCPS, in accordance<br />

with section 3.6 of the attached specifications.<br />

- Misc. Systems N/A Hour<br />

$_____________<br />

562B Installer labor rate not to exceed $65.00 per hour. - Misc. Systems N/A Hour $_____________<br />

GROUP 7: Percent Discount off List<br />

For additional support functions or modifications to new or existing Miscellaneous System Locations OEM parts may<br />

563 be required. Bidder(s) shall indicate the percent of discount off the manufacturer's most recent published price list. _____________ %<br />

A minimum of 30% off the most recent OEM published list price is required.<br />

Discount<br />

Page 22 FM-3738 Rev. (06-98)


BID PROPOSAL FORM (FORMAT B)<br />

Bid # <strong>008</strong>-<strong>HH11</strong><br />

Bid Title: FIRE ALARM SERVICES CONTRACT<br />

Buyer: Vanessa Y. Gomez<br />

PLEASE COMPLETE ALL<br />

HIGHLIGHTED AREAS<br />

NAME OF BIDDER:<br />

IMPORTANT BID NOTES: THE MONTHLY PRICE PER SCHOOL SHOULD CONSIST OF ALL ITEMS LISTED IN PART 3 - EXECUTION, IN ACCORDANCE WITH<br />

CODES, REGULATIONS, RULES, STANDARDS AND/OR STATUTES, OF THE BID SPECIFICATIONS.<br />

VENDOR SHALL INDICATE MANUFACTURER'S WARRANTY, IF GREATER THAN ONE YEAR ______________<br />

ITEM DESCRIPTION QTY MANUFACTURER MODEL<br />

UNIT<br />

PRICE PER<br />

MONTH<br />

Bidder should use the following checklist to assist in bid<br />

submission including but not limited to:<br />

<br />

Bid Proposal Form Price Sheets Completed<br />

Bidders Qualification Form Signed<br />

Fire Protection System Contractor I or II Certificate<br />

Insurance Documentation<br />

List of emergency telephone numbers<br />

List of technicians with qualifications and training certificates<br />

Occupational License<br />

Two (2) Reference Letters<br />

Vendor Information Sheet<br />

Page 23 FM-3738 Rev. (06-98)