02.11.2014 Views

EATON PLC, I/O & Communications Products ... - IEC Supply, LLC

EATON PLC, I/O & Communications Products ... - IEC Supply, LLC

EATON PLC, I/O & Communications Products ... - IEC Supply, LLC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

1<br />

May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong><br />

<strong>Products</strong><br />

Contents<br />

Description<br />

Page<br />

ELC Programmable Logic Controllers<br />

Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />

ELC Controllers / Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />

ELC Graphics Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

ELC Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

EZ Intelligent Relays<br />

Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

EZ 500/700/800/EZD Intelligent Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

EZD Controller I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

EZ/EZD Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />

EZ/EZD Communication Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />

IT. Connect<br />

Remote I/O Modules (D77A Series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<br />

Starter Network Adapters (SNAP) (D77B Series) . . . . . . . . . . . . . . . . . . . 51<br />

DeviceNet SNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

QCPort SNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53<br />

Communication Adapters (D77D Series) . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

DeviceNet Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

Modbus Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />

EtherNet/IP Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

PROFIBUS Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />

CH Studio Component Manager Software . . . . . . . . . . . . . . . . . . . . . . . . 63<br />

Note: Supplement to Publication No. CA08102001E — Tabs 49 and 50.<br />

ELC and IT. <strong>Products</strong><br />

CA05001001E<br />

For more information visit: www.eaton.com


2<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers / Modules<br />

May 2007<br />

ELC Product Family Overview<br />

ELC Modules<br />

The Eaton Logic Controller (ELC) is our<br />

latest offering into the <strong>PLC</strong> (Programmable<br />

Logic Controller) marketplace.<br />

With the latest technology, this<br />

reduced sized ELC with its abundant<br />

module selection will provide a “Just<br />

Right” concept of providing only what<br />

you want for the price you need.<br />

■ Size – Providing large <strong>PLC</strong> features/<br />

functions in a small 1" package. ELC is<br />

1/3 the size of a D50, offering identical<br />

and even a larger feature set than the<br />

D50. ELC can provide 46 I/O in the<br />

space that a D50 could provide 14 I/O.<br />

■ Flexibility – ELC controllers can<br />

handle I/O counts from 10 I/O to 256<br />

I/O using the same controller. ELC<br />

eliminates the process of counting<br />

I/O and deciding which controller to<br />

use, ELC is the only one needed.<br />

ELC modules come in many flavors<br />

of I/O from modules containing<br />

4 in / 4 out to modules containing<br />

8 in / 8 out. ELC is not a rack based<br />

system — it simply mounts to a DIN<br />

rail. Add modules by simply snapping<br />

them into the mating connectors<br />

and closing the attached locks.<br />

■ Large <strong>PLC</strong> Features – ELC has the<br />

feature set of larger <strong>PLC</strong>s, from its<br />

multiple communications ports,<br />

remote I/O ability, data storage, high<br />

speed counter, high speed pulse<br />

outputs, interrupts, timer resolution<br />

to 1 ms, PID, plus much more.<br />

■ Software – ELCSoft, the software,<br />

configures the entire line of ELC<br />

controllers. Priced less than $200,<br />

it programs in standard ladder logic<br />

and sequential function chart programming.<br />

It will aid in knowing<br />

what registers are in use and what<br />

modules are attached to the ELC. It<br />

monitors the runtime application,<br />

allows forcing (except basic), and<br />

entering values. Software wizards<br />

aid programming of remote I/O,<br />

standard communications and PIDs.<br />

■ Power of One – ELC communicates<br />

easily to MVX drives, eliminating<br />

the need to operate drives by analog<br />

voltage/current or digital I/O. ELC<br />

can access all of the parameters in<br />

the MVX by serial communications,<br />

saving OEM money. ELC communicates<br />

to IT. I/O through the Modbus<br />

TCP gateway. This allows ELC to<br />

control the IT. I/O if local control is<br />

desired. This will also allow IT. I/O to<br />

be used in communicating MCC<br />

applications where the ELC can be<br />

either a DeviceNet, Profibus, or<br />

ModbusTCP communicating MCC.<br />

ELC communicates to PowerNet<br />

Modbus products, allowing ELC<br />

connectivity to Switchgear and<br />

PowerNet applications.<br />

■ Price – Following the “Just Right”<br />

concept, ELC is priced correctly to<br />

please customers.<br />

ELC Controllers/Modules<br />

Product Description<br />

ELC Controllers<br />

The ELC family offers four styles of<br />

controllers. These controllers offer<br />

combinations of the following features:<br />

■ High speed pulse capture and high<br />

speed pulse output on all controllers<br />

■ Interrupts<br />

■ Large module selection AC/DC in,<br />

relay/transistor out<br />

■ Large analog selection of analog in,<br />

out, combined, thermocouple, RTD<br />

Platinum<br />

■ Over 200 instructions to choose<br />

from: Floating point math, communications,<br />

hex, decimal, octal, BCD,<br />

ASCII conversion, 1, 4, 8, 16, 32, bit<br />

manipulations, logical, block move,<br />

block compare, retentive data storage,<br />

time base from clock/calendar<br />

■ 2 Modbus (ASCII or RTU) serial<br />

ports: 1 slave only, 1 master/slave<br />

■ Network communications on<br />

Modbus TCP, DeviceNet and<br />

Profibus<br />

■ ELC controller can be wired for<br />

remote I/O communications (except<br />

the PB model).<br />

ELC Modules<br />

ELC Expansion Modules<br />

ELC expansion modules provide the<br />

correct amount of I/O for application<br />

solutions. Choose 4, 8, or 16 I/O. Any<br />

number of expansion modules can be<br />

added to the ELC processor to create<br />

256 I/O (128 Inputs and 128 Outputs<br />

maximum).<br />

ELC Specialty Modules<br />

In addition the to expansion I/O, specialty<br />

modules like Analog In, Analog<br />

Out, Platinum Temperature, Thermocouple,<br />

DeviceNet, PROFIBUS DP and<br />

Switch Module, etc. can be added. Use<br />

the ELC-485APTR to easily connect to<br />

the RS-485 port of MVX drive, ELC controllers<br />

and other devices.<br />

Catalog Number Selection<br />

Table 1. ELC Controllers/Modules Catalog Numbering System<br />

E L C - A N 02 N A N N<br />

Module Type<br />

Digital Outputs<br />

AN = Analog<br />

EX = Digital Expansion<br />

PA = Processor w/clock & analog<br />

PB = Processor w/o clock<br />

PC = Processor w/clock<br />

PH = Processor, high speed<br />

PT = PT100<br />

TC = Thermocouple<br />

Analog Inputs<br />

A =AC<br />

N = None<br />

I/O Count<br />

Digital Inputs<br />

A =AC<br />

D =DC<br />

N = None<br />

Analog Outputs<br />

A = Analog<br />

N = None<br />

I = High Currency Relay<br />

N = None<br />

R = Relay<br />

T = Transistor<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers / Modules<br />

3<br />

Features<br />

ELC Controllers<br />

POWER<br />

POWER<br />

POWER<br />

POWER<br />

RUN<br />

ERROR<br />

BAT.LOW<br />

RUN<br />

ERROR<br />

BAT.LOW<br />

RUN<br />

ERROR<br />

BAT.LOW<br />

RUN<br />

ERROR<br />

BAT.LOW<br />

RUN<br />

RUN<br />

RUN<br />

RUN<br />

STOP<br />

STOP<br />

STOP<br />

STOP<br />

0<br />

0<br />

1<br />

1<br />

ELC-PB14 Series ELC-PC12 Series ELC-PA10 Series ELC-PH12NNDT<br />

Figure 1. ELC Controllers<br />

Table 2. ELC Controller Features<br />

Items ELC-PB14 Series ELC-PC12 Series ELC-PA10 Series ELC-PH12NNDT<br />

Maximum I/O<br />

I/O Type 14<br />

(8 In / 6 Out) – Digital<br />

256 (128 In / 128 Out) Any number of modules<br />

12<br />

(8 In / 4 Out – Digital)<br />

10<br />

(4 In / 2 Out Digital,<br />

2 In / 2 Out Analog)<br />

Execution Speed<br />

Basic commands - 2µ seconds minimum<br />

Program Language<br />

Boolean + Ladder Logic + SFC<br />

Program Capacity 3792 Steps 7920 Steps<br />

Data Memory Capacity (bits) 1280 Bits 4096 Bits<br />

Data Memory Capacity (words) 744 Words 5000 Words<br />

Index Registers 2 Words 8 Words<br />

File Memory Capacity — 1600 Words<br />

Commands 32 Basic / 107 Advanced 32 Basic / 168 Advanced<br />

Floating Point Yes Yes<br />

SFC Commands 128 Steps 1024 Steps<br />

Timers 128 (1 – 100 ms) 256 (1 – 100 ms)<br />

Counters 128<br />

(16 Bit / 32 Bit / Up/Down)<br />

250 (16 Bit / 32 Bit / Up/Down)<br />

High Speed Counters 1<br />

(14 modes) 10K Max<br />

1 (14 modes)<br />

20 kHz for PA/PC<br />

100 kHz for PH<br />

12<br />

(8 In / 4 Out – Digital)<br />

Pulse Output 2 channels 10 kHz Max 2 channels, 40 kHz Max for PC/PA, 100 kHz for PH<br />

Master Control Loop<br />

8 Loops<br />

Subroutines 64 Subroutines 256 Subroutines<br />

Interrupts 6 15 (External / Time base / HS CNTR / Comm.)<br />

Real-time Clock/Calendar — Built-in<br />

Specialty Expansions Modules<br />

8 (Analog In / Analog Out / TC / PT) Modules do not count in total I/O<br />

Serial Ports<br />

2 (1 – RS-232, 1 – RS-485)<br />

Special Features — 2 Potentiometers 2 7-Segment Displays 2 Potentiometers<br />

CA05001001E<br />

For more information visit: www.eaton.com


4<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers / Modules<br />

May 2007<br />

ELC Expansion Modules<br />

Style 1 Style 2<br />

Figure 2. ELC Expansion Modules<br />

Table 3. ELC Expansion Module Features<br />

Model Style Inputs Outputs<br />

Points Type Points Type<br />

ELC-EX08NNAN — AC IN 1 8 120V AC 0 —<br />

ELC-EX08NNDN — DC IN 1 8 DC Sink or Source 0 —<br />

ELC-EX08NNNR — Relay OUT 1 0 — 8 Relay<br />

ELC-EX08NNNT — Transistor OUT 1 0 — 8 Transistor<br />

ELC-EX06NNNI — High Current Relay OUT 2 0 — 6 Relay (6 Amps)<br />

ELC-EX08NNDR — IN/OUT Combo 2 4 DC Sink or Source 4 Relay<br />

ELC-EX16NNDR — IN/OUT Combo 2 8 DC Sink or Source 8<br />

ELC-EX08NNDT — IN/OUT Combo 2 4 DC Sink or Source 4 Transistor<br />

ELC-EX16NNDT — IN/OUT Combo 2 8 DC Sink or Source 8<br />

For more information visit: www.eaton.com<br />

CA05001001E


3<br />

3<br />

2<br />

2 2<br />

7<br />

8<br />

7<br />

8<br />

May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers / Modules<br />

5<br />

ELC Specialty Modules<br />

ON<br />

IN<br />

POWER<br />

POWER<br />

ELC-EX08NNSN<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

X0<br />

X1<br />

X2<br />

X3<br />

X4<br />

X5<br />

X6<br />

X7<br />

ELC-COPBDP<br />

NET<br />

NODE ADDRESS<br />

x16 1<br />

x16 0<br />

ELC-CODNET<br />

MS<br />

NS<br />

4<br />

1<br />

4<br />

1<br />

5<br />

0<br />

5<br />

0<br />

6<br />

9<br />

6<br />

9<br />

1 2 3 4<br />

DIP ON<br />

1<br />

x10<br />

0<br />

x10<br />

DR1<br />

DR0<br />

IN1<br />

IN0<br />

ELC-EX485APTR<br />

COM2 COM1<br />

7<br />

Style 1 Style 2<br />

Figure 3. ELC Specialty Expansion Modules<br />

Style 3 Style 4 Style 5<br />

Style 6 — with<br />

ELC-ACCOVER<br />

Table 4. ELC Expansion Module Features<br />

Model Power Style Inputs Outputs<br />

Points Type Points Type<br />

ELC-AN02NANN — Analog OUT 24V DC 1 0 -20 mA~20 mA 2 (12 bits) 0~20 mA, 4~20 mA<br />

ELC-AN04NANN — Analog OUT 2 0 -10V ~ +10V 4 (12 bits) 0V ~ +10V, 2V ~ +10V<br />

ELC-AN06AANN — Analog Combo 2 4 ±10V, ±20 mA 2 (12 bits) 0~20 mA, 0 ~ +10V<br />

ELC-AN04ANNN — Analog IN 2 4 (V = 14 bits, I = 11 bits ±10V, ±20 mA 0<br />

ELC-PT04ANNN — PT100 2 4 (V = 14 bits, I = 13 bits) PT100 0<br />

ELC-TC04ANNN — Thermocouple 2 4 Thermocouple 0<br />

ELC-EX08NNSN — Switch Input 24V DC 3 8 Switch 0<br />

ELC-COPBDP — PROFIBUS DP 24V DC 4 32 Digital 32 Digital<br />

ELC-CODNET — DeviceNet 24V DC 5 32 Digital 32 Digital<br />

ELC-485APTR — RS-485 Easy Connect N/A 6 0 — 0 —<br />

CA05001001E<br />

For more information visit: www.eaton.com


6<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers / Modules<br />

May 2007<br />

Product Selection<br />

Table 5. ELC Controllers (PB, PC, PA, PH)<br />

Description Inputs Outputs Max. Current<br />

AC DC Analog Relay Transistor Analog<br />

Consumption<br />

(at 24V DC)<br />

14 I/O PB Series<br />

14 I/O PB Series<br />

12 I/O PC Series<br />

12 I/O PC Series<br />

12 I/O PC Series<br />

10 I/O PA Series<br />

10 I/O PA Series<br />

8<br />

8<br />

8<br />

8<br />

8<br />

6<br />

4<br />

4<br />

6<br />

150 mA<br />

150 mA<br />

250 mA<br />

250 mA<br />

250 mA<br />

Catalog<br />

Number<br />

ELC-PB14NNDR<br />

ELC-PB14NNDT<br />

ELC-PC12NNAR<br />

ELC-PC12NNDR<br />

ELC-PC12NNDT<br />

4<br />

4 2<br />

2<br />

2<br />

210 mA<br />

ELC-PA10AADR<br />

341.00<br />

4 2<br />

2<br />

2<br />

210 mA<br />

ELC-PA10AADT<br />

341.00<br />

12 I/O PH Series 8 4 170 mA ELC-PH12NNDT 198.00<br />

Price<br />

U.S. $<br />

149.00<br />

149.00<br />

198.00<br />

198.00<br />

198.00<br />

Table 6. Digital I/O Expansion Modules<br />

Description Inputs Outputs Max. Current<br />

AC DC Relay Transistor<br />

Consumption<br />

(at 24V DC)<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

6 I/O Expansion (6 Amp Outputs) 6 70 mA ELC-EX06NNNI 105.00<br />

8 I/O Expansion — AC IN<br />

8<br />

50 mA<br />

ELC-EX08NNAN<br />

71.50<br />

8 I/O Expansion — DC IN<br />

8<br />

50 mA<br />

ELC-EX08NNDN<br />

60.50<br />

8 I/O Expansion — Relay OUT<br />

8<br />

70 mA<br />

ELC-EX08NNNR<br />

93.50<br />

8 I/O Expansion — Transistor OUT<br />

8<br />

70 mA<br />

ELC-EX08NNNT<br />

93.50<br />

8 I/O Expansion — IN/OUT Combo<br />

4 4<br />

70 mA<br />

ELC-EX08NNDR<br />

93.50<br />

8 I/O Expansion — IN/OUT Combo<br />

4<br />

4<br />

70 mA<br />

ELC-EX08NNDT<br />

93.50<br />

16 I/O Expansion — IN/OUT Combo<br />

8 8<br />

90 mA<br />

ELC-EX16NNDR<br />

105.00<br />

16 I/O Expansion — IN/OUT Combo<br />

8<br />

8<br />

90 mA<br />

ELC-EX16NNDT<br />

105.00<br />

8 I/O Expansion — Switch Input 8 20 mA ELC-EX08NNSN 71.50<br />

Table 7. Analog I/O Modules<br />

Description<br />

Analog<br />

In<br />

Analog<br />

Out<br />

Max. Current<br />

Consumption<br />

(at 24V DC)<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

4 I/O Analog In 4 90 mA ELC-AN04ANNN 193.00<br />

2 I/O Analog Out 2 125 mA ELC-AN02NANN 182.00<br />

4 I/O Analog Out 4 170 mA ELC-AN04NANN 253.00<br />

6 I/O Analog In/Out 4 2 90 mA ELC-AN06AANN 264.00<br />

4 I/O Thermocouple J, K, R, S, T 4 90 mA ELC-TC04ANNN 275.00<br />

4 I/O Platinum RTD, PT100 4 90 mA ELC-PT04ANNN 242.00<br />

Table 8. Accessory Modules<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

Profibus DP Module ELC-COPBDP 358.00<br />

DeviceNet Module ELC-CODNET 253.00<br />

RS-485 Easy Connect Adapter, DB9, ELC-485APTR 60.50<br />

RJ-12, 2-Pin Connections to RS-485<br />

Motion Control, 1 Axis Module<br />

(Up to 8 Modules per Controller)<br />

ELC-MCO1 336.00<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers / Modules<br />

7<br />

Standards and Certifications<br />

Table 9. Approvals/Certifications<br />

Description<br />

Electrical/EMC<br />

ESD Immunity<br />

EFT Immunity<br />

Damped-Oscillatory Wave<br />

RS Immunity<br />

Other Approvals<br />

Agency Certifications<br />

Technical Data and Specifications<br />

Table 10. Environmental Ratings<br />

Description<br />

Transportation & Storage<br />

Specification<br />

Table 11. DC Input Point Electrical Specifications<br />

8 kV air discharge<br />

Power Line: 2 kV; Digital I/O: 1 kV; Analog & Communication I/O: 250V<br />

Power Line: 1 kV; Digital I/O: 1 kV<br />

26 MHz – 1 GHz, 10 V/m<br />

UL 508, cUL, CE; Class 1 Div 2 Group A, B, C, D<br />

Specification<br />

Temperature<br />

-13° – 158°F (-25° – 70°C)<br />

Humidity 5 – 95%<br />

Operating<br />

Temperature<br />

32° – 131°F (0° – 55°C)<br />

Humidity 50 – 95%<br />

Power <strong>Supply</strong> Voltage ELC: 24V DC (-15% – 20%) (With DC input reverse polarity protection),<br />

Expansion Unit: supplied by the ELC<br />

Power Consumption 3 – 6W<br />

Insulation Resistance > 5 MΩ at 500V DC (Between all inputs/outputs and earth)<br />

Grounding<br />

The diameter of grounding wire cannot be smaller than the wire<br />

diameter of terminals L and N (All ELC units should be grounded<br />

directly to the ground pole).<br />

Vibration / Shock Resistance Standard: <strong>IEC</strong>1131-2, <strong>IEC</strong> 68-2-6 (TEST Fc) / <strong>IEC</strong>1131-2 & <strong>IEC</strong> 68-2-27<br />

(TEST Ea)<br />

Weight (approx.)<br />

0.348 Lbs (0.158 kg)<br />

Description<br />

Specification<br />

Input Type<br />

Input Current<br />

Active Level<br />

Response Time<br />

DC (SINK or SOURCE)<br />

24V DC 5 mA<br />

OFF ➔ ON, above 16V DC<br />

ON ➔ OFF, below 14.4V DC<br />

About 10 mS (An adjustment range of 0 – 10,000 mS could be selected<br />

through D1020 and D1021)<br />

Table 12. Output Point Electrical Specifications<br />

Output Type Relay – R Transistor – T<br />

Current Specification 1.5A/1 point (5A/COM) 0.3A/1 point @ 40°C; When the output of Y0 and Y1 is high-speed pulse,<br />

Y0 and Y1 = 30 mA<br />

Voltage Specification Below 250V AC, 30V DC 30V DC<br />

Maximum Loading 75 VA (Inductive) 9W/1 point When the output of Y0 and Y1 is high-speed pulse, Y0 and<br />

90W (Resistive)<br />

Y1 = 0.9W (Y0 = 32 kHz, Y1 = 10kHz), Y0 can be 50 kHz using<br />

D registers.<br />

Response Time Adjustable 0 – 15 ms, default is 10 ms OFF ➔ ON 20 µs<br />

ON ➔ OFF 30 µs<br />

Y0 and Y1 are specified points for high-speed pulse<br />

CA05001001E<br />

For more information visit: www.eaton.com


ANB<br />

AND<br />

SPACE<br />

CLEAR<br />

SHIFT<br />

TEST<br />

STOP<br />

8<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers/Modules<br />

May 2007<br />

ELC Accessories<br />

ELC-GPXFERMOD<br />

Transfer programs to or from ELC-GPxx<br />

units. These devices can be write protected<br />

to maintain program integrity.<br />

ELC-HHP<br />

ELC-HHP is an easy-to-use, hand-held<br />

programming tool for ELC controllers<br />

when a PC is not available. With ELC-<br />

HHP, applications can be programmed<br />

directly with the attached keypad. Or<br />

uploaded from an ELC, saved, and<br />

transferred to a different ELC. Or<br />

downloaded from a PC and transferred<br />

to other ELCs. No need for outlets<br />

when using the ELC-HHP since it<br />

draws its power from either the ELC<br />

or the PC through the attached cable.<br />

Monitor applications when a PC is not<br />

available.<br />

LD<br />

LDI<br />

X<br />

OUT<br />

T<br />

ANI<br />

Y<br />

SET<br />

C<br />

OR<br />

RST<br />

8<br />

ORI<br />

M<br />

TMR<br />

D<br />

API<br />

NOP<br />

4<br />

ORB<br />

K<br />

CNT<br />

9<br />

S<br />

0<br />

MC<br />

H P/I<br />

E<br />

RUN<br />

MPS<br />

5<br />

END<br />

MCR<br />

A<br />

1<br />

STL<br />

F<br />

STEP<br />

MRD<br />

6<br />

MAIN<br />

RET<br />

B<br />

2<br />

EDIT<br />

MPP<br />

3<br />

7<br />

MON<br />

INS<br />

DEL<br />

Figure 4. ELC-HHP with Cables for ELC and PC Connections<br />

ELC Power Supplies<br />

All ELC modules operate from 24V DC.<br />

These power supplies provide a convenient<br />

way to provide robust DC voltage.<br />

L<br />

N<br />

L<br />

N<br />

24V<br />

0V<br />

24V<br />

0V<br />

POWER<br />

ELC-PS01<br />

POWER<br />

ELC-PS02<br />

Figure 5. ELC Power Supplies<br />

Table 13. ELC Power <strong>Supply</strong> Specifications<br />

Item ELC-PS01 ELC-PS02<br />

Dimensions WxHxD in Inches (mm) 1.44 x 3.54 x 2.36 (36.5 x 90 x 60) 2.17 x 3.54 x 2.36 (55 x 90 x 60)<br />

Input Power<br />

100 – 240V AC 50/60 Hz<br />

Output Volts<br />

24V DC<br />

Output Current (A) 1A 2A<br />

Watts 24 48<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers/Modules<br />

9<br />

ELC-CBPCELC3<br />

Use this cable to download, upload,<br />

monitor ELC controllers. Or use this<br />

same cable to connect any ELC-GPxx<br />

to an ELC controller. This cable is 3<br />

meters long.<br />

PC/HMI COM Port<br />

9 PIN D-SUB Female<br />

<strong>PLC</strong> COM1 Port<br />

8 PIN MINI DIN<br />

Rx 2 5 Tx<br />

Tx 3 4 Rx<br />

2<br />

1<br />

1<br />

4<br />

GND 5 8 GND<br />

7<br />

1,2 5V<br />

8<br />

5<br />

8<br />

4<br />

7<br />

3<br />

6<br />

6<br />

Figure 6. ELC-CBPCELC3 Cable<br />

ELC-CBPCGP3<br />

Use this cable to download or upload<br />

applications between a PC and the<br />

ELC-GPxx graphics panels. This cable<br />

can also be used to transfer a program<br />

from an ELC-GPxx to another ELC-<br />

GPxx. This cable is 3 meters long.<br />

■ The Pin definition of 9 PIN D-SUB<br />

RS-232:<br />

ELC-GP04 COM Port<br />

RS-232 9 PIN D-SUB Male<br />

3<br />

2<br />

5<br />

Tx<br />

Rx<br />

GND<br />

ON PC (RS-232)<br />

ON ELC-GP02/04<br />

9<br />

5<br />

1<br />

6<br />

6<br />

1<br />

5<br />

9<br />

9 PIN D-SUB<br />

9 PIN D-SUB<br />

PC COM Port<br />

9 PIN D-SUB Female<br />

GP02/04 COM Port<br />

9 PIN D-SUB Female<br />

Rx 2 3 Tx<br />

Tx 3 2 Rx<br />

GND 5 5 GND<br />

Figure 7. PC or GPO2/04<br />

CA05001001E<br />

For more information visit: www.eaton.com


10<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers/Modules<br />

May 2007<br />

Table 14. ELC Accessories<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

24 Watt, 1 Amp Power <strong>Supply</strong> ELC-PS01 49.50<br />

48 Watt, 2 Amp Power <strong>Supply</strong> ELC-PS02 71.50<br />

Hand-Held Programmer (Includes ELC-CBHHELC15) ELC-HHP 286.00<br />

Cable to Connect a PC or a GP unit to ELC, 3 meters (DB9 pin ELC-CBPCELC3 34.25<br />

female to 8 pin DIN)<br />

Cable to Connect a PC to a GP unit. 3 meters (DB9 pin female ELC-CBPCGP3 34.25<br />

to DB9 pin female)<br />

Program transfer module for GP units ELC-GPXFERMOD 71.50<br />

Program transfer module for ELC controllers ELC-ACPGMXFR 105.00<br />

Plate mount for specialty modules, qty. 10 ELC-ACCOVER 82.50<br />

ELC Starter Kit (Includes ELC-PA10AADT, ELC-PS01, ELC-GP04,<br />

ELC-CBPCELC3, ELC-CBPCGP3, ELCSoft, ELCSoft GP)<br />

ELCSTARTKIT1 605.00<br />

Dimensions<br />

.12<br />

(3.0)<br />

POWER<br />

RUN<br />

ERROR<br />

BAT.LOW<br />

1.47<br />

(37.4)<br />

2.36<br />

(60.0)<br />

RUN<br />

3.54<br />

(90.0)<br />

STOP<br />

EXTENSION<br />

PORT<br />

.12<br />

(3.0)<br />

Figure 8. ELC-PA10, ELC-PC12 and ELC-PH12 Controllers — Approximate Dimensions in Inches (mm)<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers/Modules<br />

11<br />

.12<br />

(3.0)<br />

0.99<br />

(25.2)<br />

2.36<br />

(60.0)<br />

.12<br />

(3)<br />

3.54<br />

(90.0)<br />

EXTENSION<br />

PORT<br />

3.94<br />

(100)<br />

3.54<br />

(90)<br />

4.20<br />

(106.8)<br />

.12<br />

(3.0)<br />

.27<br />

(6.8)<br />

.12<br />

(3)<br />

2.51 (63.4)<br />

.28<br />

(7)<br />

Figure 11. Plate Mount for Specialty Modules<br />

Figure 9. ELC-PB14 Controllers — Approximate Dimensions in<br />

Inches (mm)<br />

.12<br />

(3.0)<br />

0.99<br />

(25.2)<br />

2.36<br />

(60.0)<br />

3.54<br />

(90.0)<br />

EXTENSION<br />

PORT<br />

.12<br />

(3.0)<br />

Figure 10. ELC Specialty Module — Approximate Dimensions in<br />

Inches (mm)<br />

CA05001001E<br />

For more information visit: www.eaton.com


12<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers/Modules<br />

May 2007<br />

2.00 (50.9)<br />

.78 (19.8)<br />

.39 (10.0)<br />

Figure 12. ELC-GPXFERMOD — Approximate Dimensions in Inches (mm)<br />

3.54<br />

(90.0)<br />

1.14<br />

(29.0)<br />

2.64<br />

(67.0)<br />

M3 p0.5<br />

4 Places<br />

7.09<br />

(180.0)<br />

3.60<br />

(91.5)<br />

1.81<br />

(46.0)<br />

1.73<br />

(44.0)<br />

Figure 13. ELC-HHP — Approximate Dimensions in Inches (mm)<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Controllers/Modules<br />

13<br />

1.44<br />

(36.5)<br />

.52<br />

(13.3)<br />

2.36<br />

(60.0)<br />

3.54<br />

(90.0)<br />

.12<br />

(3.0)<br />

Figure 14. ELC-PS01 Power <strong>Supply</strong> — Approximate Dimensions in Inches (mm)<br />

.12<br />

(3.0)<br />

2.17<br />

(55.0)<br />

1.28<br />

(32.5)<br />

.52<br />

(13.3)<br />

2.36<br />

(60.0)<br />

3.94<br />

(100.0)<br />

3.54<br />

(90.0)<br />

.12<br />

(3.0)<br />

Figure 15. ELC-PS02 Power <strong>Supply</strong> — Approximate Dimensions in Inches (mm)<br />

CA05001001E<br />

For more information visit: www.eaton.com


14<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Graphics Panels<br />

May 2007<br />

ELC Graphics Panels<br />

Product Description<br />

ELC Graphics Panels are simple to program<br />

and easily connect to ELC products.<br />

ELC graphics panels make<br />

modifying an application quick and<br />

easy. ELC graphics panels also connect<br />

to Cutler-Hammer ® MVX drives, IQ<br />

MODBUS meters and many other<br />

devices. With over 30 objects that can<br />

be placed anywhere on the display,<br />

these tough panels also communicate<br />

to other major controllers. These<br />

graphics panels have two serial ports<br />

which can be used simultaneously to<br />

communicate. Transfer applications to<br />

or from these graphics panels using<br />

the handy transfer module. Ten programmable<br />

functions keys provide<br />

easy to change pages, input numeric<br />

values, enter alpha-numeric passwords,<br />

set, reset and more. Create alarms,<br />

password protect, import bitmaps, and<br />

use many different fonts.<br />

Protocols Supported<br />

■ Eaton D50/D32LT, D320<br />

■ Eaton ELC<br />

■ Eaton MVX ASCII<br />

■ Eaton MVX RTU<br />

■ MODBUS ASCII<br />

■ MODBUS RTU<br />

■ AB DF1<br />

■ Mitsubishi FX Series<br />

■ Mitsubishi FX2N Series<br />

■ Koyo K-Sequence<br />

■ LG 200S<br />

■ OMRON C-Series<br />

■ Siemens 57-200 Series<br />

■ ASCII Slave Mode<br />

■ And more...<br />

0<br />

50<br />

100<br />

Features<br />

No Alarms<br />

Tank Fill Level<br />

ELC-GP02<br />

Table 15. ELC Graphics Panel Features<br />

Item ELC-GP02 ELC-GP04<br />

Display Screen<br />

Screen<br />

STN-LCD<br />

Color<br />

Monochromatic<br />

Back-light<br />

The back-light automatic turn off time is 1 – 99 minutes<br />

(0 = do not to turn off)<br />

(back-light life is 50 thousand hours at 25°C)<br />

Resolution 160X32 pixels 128X64 pixels<br />

Display Range 72 mm (W) X 22 mm (H) 67mm (W) X 32mm (H);<br />

3.00" (diagonal preferred)<br />

Contrast Adjustment 15-step contrast adjustment 10-step contrast adjustment<br />

Language Font<br />

ASCII: characters (including European Fonts)<br />

Taiwan: (BIG 5 code) traditional Chinese character font<br />

China: (GB2324-80 code) simplified Chinese character font<br />

Font Size (ASCII) 5 X 8, 8 X 8, 8 X 12, 8 X 16<br />

ALARM Indication LED<br />

1. Power on indication (Flash three times)<br />

2. Flash for communication error or other alarm<br />

3. Special Indication by user programming<br />

RS-232 LED (Yellow)<br />

Flashes when communicating<br />

RS-485 LED (Green)<br />

Flashes when communicating<br />

Program Memory<br />

Program Memory<br />

256KB flash memory<br />

External Interface<br />

Serial Communication Port<br />

RS-232 (COM1)<br />

9 PIN D-SUB male<br />

Extension Communication port<br />

RS-485 (COM2)<br />

5-Pin Removal Terminal<br />

(RS-485 or RS-422)<br />

Extension Slot<br />

Power<br />

RUN<br />

ELC-GP04<br />

RUN<br />

F3<br />

F4<br />

STOP<br />

Data length: 7 or 8 bits<br />

Stop bits: 1 or 2 bits<br />

Parity: None/Odd/Even<br />

Baud Rate: 4800 bps – 115200 bps<br />

Data length: 7 or 8 bits<br />

Stop bits: 1 or 2 bits<br />

Parity: None/Odd/Even<br />

Baud Rate: 4800 bps – 115200 bps<br />

The slot for program copy card<br />

24V DC input<br />

Product Selection<br />

Table 16. Graphics Panels<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

160 x 32 pixels, 10 Function Keys, Monochrome ELC-GP02 209.<br />

128 x 64 pixels, 10 Function Keys, Monochrome ELC-GP04 314.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Graphics Panels<br />

15<br />

Standards and Certifications<br />

Table 17. Approvals/Certifications<br />

Description<br />

Electrical/EMC<br />

Electrostatic Discharge Immunity<br />

Radiated Immunity<br />

Electrical Fast Transient<br />

Radiated Emission<br />

Other Approvals<br />

Waterproof Class of Front Panel<br />

Agency Certifications<br />

Specifications<br />

EN61000-4-2/1995<br />

EN61000-4-3/1995<br />

EN61000-4-4/1995<br />

CISPR22, Class A<br />

UL Type 4X Outdoor Rated<br />

UL 508, cUL (CSA C22.2 No. 14); CE (Low Voltage Directive);<br />

Class 1 Div 2 Groups A, B, C, D<br />

Technical Data and Specifications<br />

Table 18. Environmental Ratings/Specifications<br />

Description<br />

Transportation & Storage<br />

Temperature<br />

Operating<br />

Temperature<br />

Humidity<br />

Communication Interface<br />

Vibration<br />

Impact<br />

Weight<br />

Cooling Method<br />

Specification<br />

-4° – 140°F (-20° – 60°C)<br />

32° – 122°F (0° – 50°C)<br />

20 – 90% RH (non-condensing)<br />

COM1: RS-232; COM2: RS-485/RS-422<br />

0.5 mm displacement, 10 – 55 Hz, X, Y, Z three directions and<br />

two hours for each direction<br />

10G, 11 mS, from X, Y, Z three directions and three times for<br />

each direction<br />

0.53 Lbs. (0.24 kg)<br />

Natural Air Cooling<br />

CA05001001E<br />

For more information visit: www.eaton.com


16<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Graphics Panels<br />

May 2007<br />

Dimensions<br />

ALARM<br />

RS-232<br />

RS-485<br />

Up<br />

Pg Up<br />

3.82<br />

(97.0)<br />

Left<br />

Right<br />

3.35<br />

(85.0)<br />

Esc<br />

Pg Dn<br />

Down<br />

Shift<br />

F0<br />

F5<br />

F1<br />

F6<br />

F2<br />

F7<br />

F3<br />

F8<br />

F4<br />

F9<br />

Enter<br />

5.79<br />

(147.0)<br />

1.20<br />

(30.5)<br />

.14<br />

(3.5)<br />

1.40<br />

(35.5)<br />

5.31<br />

(135.0)<br />

Cut-Out Dimensions<br />

3.35<br />

(85.0)<br />

5.31 ~ 5.37<br />

(135 ~ 136.5)<br />

Figure 16. ECL-GP04 — Approximate Dimensions in Inches (mm)<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Graphics Panels<br />

17<br />

ALARM<br />

RS-232<br />

RS-485<br />

3.82<br />

(97.0)<br />

3.35<br />

(85.0)<br />

Esc<br />

F5<br />

5<br />

F0<br />

0<br />

F6<br />

6<br />

F1<br />

1<br />

F7<br />

7<br />

F2<br />

2<br />

F3<br />

3<br />

F8 F9<br />

8 9<br />

F4<br />

4<br />

Enter<br />

Left<br />

Up<br />

Pg Up<br />

Pg Dn<br />

Down<br />

Right<br />

5.79<br />

(147.0)<br />

1.20<br />

(30.5)<br />

.14<br />

(3.5)<br />

1.40<br />

(35.5)<br />

5.31<br />

(135.0)<br />

Cut-Out Dimensions<br />

3.35<br />

(85.0)<br />

5.31 ~ 5.37<br />

(135 ~ 136.5)<br />

Figure 17. ECL-GP02 — Approximate Dimensions in Inches (mm)<br />

CA05001001E<br />

For more information visit: www.eaton.com


18<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

ELC Programmable Logic Controllers<br />

ELC Software<br />

May 2007<br />

ELCSoft Programming<br />

Software<br />

ELCSoft Programming Software<br />

configures all ELC controllers. With<br />

ELCSoft, applications can be created,<br />

edited, monitored, forced, etc. Move<br />

programs from one controller to a<br />

different one with ease.<br />

Requirements:<br />

■ Operating Systems – Windows 98,<br />

Windows ME, Windows 2000,<br />

Windows XP<br />

■ Hard Drive – At least 100M bytes<br />

■ RAM – At least 256M bytes<br />

ELCSoftGP Programming<br />

Software<br />

ELCSoftGP Programming Software<br />

configures all ELC graphics panels.<br />

With ELCSoftGP, applications can be<br />

created, edited, downloaded, uploaded,<br />

etc. Move programs from one controller<br />

to a different one with ease.<br />

Requirements:<br />

■ Operating Systems – Windows 98,<br />

Windows ME, Windows 2000, Windows<br />

XP<br />

■ Hard Drive – At least 100M bytes<br />

■ RAM – At least 256M bytes<br />

ELCSoft Ladder Diagram Mode<br />

ELCSoftGP Editing Environment<br />

Product Selection<br />

Table 19. Software<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

ELCSoft Editor<br />

Programming Software for ELC Controllers ELCSOFT 215.<br />

Programming Software for GP Units ELCSOFTGP 215.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

Product Family Overview<br />

19<br />

Contents<br />

Description<br />

Page<br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD<br />

Intelligent Relays . . . . . . . 20<br />

EZD Controller<br />

I/O Modules . . . . . . . . . . . 27<br />

EZ/EZD Expansion<br />

Modules . . . . . . . . . . . . . . 28<br />

EZ/EZD Communication<br />

Modules . . . . . . . . . . . . . . 30<br />

EZ Software . . . . . . . . . . . . 31<br />

EZ/EZD Power Supplies. . . 32<br />

EZ/EZD Accessories . . . . . . 33<br />

EZ Intelligent Relays Product Family<br />

Product Family Overview<br />

The EZ intelligent relays bring timers,<br />

relays, counters, special functions,<br />

inputs and outputs into one compact<br />

device that is easily configured. The EZ<br />

family of products provides exceptional<br />

levels of flexibility together with<br />

substantial savings in commissioning<br />

time and effort.<br />

The EZ intelligent relays are available<br />

in more than 32 different styles that<br />

support from 12 I/O up to 320 I/O<br />

points providing the ideal solution for<br />

lighting, energy management, industrial<br />

control, watering, pump control,<br />

HVAC and home automation.<br />

Once EZ products are installed, changes<br />

are easily accomplished through front<br />

panel programming, eliminating the<br />

need to change wiring and wiring diagrams<br />

increasing the savings realized.<br />

Other terms often used for intelligent<br />

relay are relay replacer, control relay<br />

and smart relay.<br />

Application Description<br />

Generally where multiple relays, timers<br />

and pushbuttons are used there is an<br />

opportunity to evaluate switching to<br />

the EZ Intelligent Relays. Applications<br />

span residential, commercial and<br />

industrial installations. Typical applications<br />

are:<br />

■ Car washes.<br />

■ Automatic door control.<br />

■ Commercial lighting.<br />

■ Residential lighting.<br />

■ Exterior lighting.<br />

■ Pump control, 12V DC automotive<br />

control.<br />

■ Greenhouse control.<br />

■ Crane control.<br />

■ Machinery.<br />

■ Paper/pulp.<br />

■ Elevator control.<br />

■ Livestock feed/gate control.<br />

■ Irrigation control.<br />

■ Cart chargers.<br />

■ Heating and air conditioning.<br />

CA05001001E<br />

For more information visit: www.eaton.com


20<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

May 2007<br />

EZ 500/700/800/EZD Intelligent<br />

Relays<br />

EZD Series — for controlling largescale<br />

applications with up to 320 input/<br />

output signals using powerful visualization<br />

functions. The EZD display can<br />

be linked to the EZ500/700/800 models<br />

to provide an enhanced operator interface.<br />

Panel mounted.<br />

The EZ-NET integrated network provides<br />

easy and inexpensive linking of<br />

up to eight EZ800/EZD devices over a<br />

distance of up to 1000 meters. The EZ<br />

and EZD devices can run their own<br />

program or be used as a distributed<br />

input/output module. Connect up to 8<br />

controllers each with 40 I/O via a signal<br />

expansion module to obtain 320 I/O.<br />

EZ 500/700/800/EZD Intelligent Relays<br />

Product Description<br />

Four families make up the EZ Intelligent<br />

Relay product line.<br />

EZ500 Series — for controlling small<br />

applications with up to 12 input/output<br />

signals. Models are available with and<br />

without displays. DIN rail mounted.<br />

EZ700 Series — for controlling<br />

medium-sized applications with up to<br />

40 input/output signals. DIN rail<br />

mounted.<br />

EZ800 Series — for controlling largescale<br />

applications with up to 320 input/<br />

output signals. Models are available<br />

with and without displays. DIN rail<br />

mounted. Use EZ-NET for applications<br />

beyond 40 I/O.<br />

Catalog Number Selection<br />

Table 20. EZ500/700/800 Module Definition Catalog Numbering System<br />

Module Type<br />

5xx = 500 Series<br />

7xx = 700 Series<br />

8xx = 800 Series<br />

Product Selection<br />

EZ 7xx AC T C X<br />

Digital Inputs<br />

AB = 24V AC<br />

AC = 110 – 240V DC<br />

DA = 12V DC<br />

DC = 24V DC<br />

Display<br />

Blank = Display<br />

X = No Display<br />

Clock<br />

C = Clock<br />

Blank = No Clock<br />

Digital Outputs<br />

R = Relay<br />

T = Transistor<br />

EZ500 with Display<br />

EZ500 without Display<br />

Table 21. EZ500 Intelligent Relays<br />

Description Inputs Outputs Catalog<br />

24V 110 – 240V 12V 24V ALG RY TRN<br />

Number<br />

AC AC DC DC<br />

Price<br />

U.S. $<br />

12 I/O, Clock, Display<br />

12 I/O, Clock, No Display<br />

12 I/O, No Clock, Display<br />

12 I/O, Clock, Display<br />

12 I/O, Clock, No Display<br />

12 I/O, Clock, Display<br />

12 I/O, Clock, No Display<br />

12 I/O, No Clock, Display<br />

12 I/O, Clock, Display<br />

12 I/O, Clock, No Display<br />

12 I/O, Clock, Display<br />

12 I/O, Clock, No Display<br />

8<br />

8<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

8<br />

8<br />

8<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

8<br />

8<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

8<br />

8<br />

8<br />

8<br />

8<br />

2<br />

2<br />

—<br />

—<br />

—<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

4<br />

4<br />

EZ512-AB-RC<br />

EZ512-AB-RCX<br />

EZ512-AC-R<br />

EZ512-AC-RC<br />

EZ512-AC-RCX<br />

EZ512-DA-RC<br />

EZ512-DA-RCX<br />

EZ512-DC-R<br />

EZ512-DC-RC<br />

EZ512-DC-RCX<br />

EZ512-DC-TC<br />

EZ512-DC-TCX<br />

155.<br />

119.<br />

144.<br />

155.<br />

119.<br />

155.<br />

119.<br />

144.<br />

155.<br />

119.<br />

139.<br />

119.<br />

Note: Analog inputs optional.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

21<br />

EZ700 with Display<br />

EZ700 without Display<br />

Table 22. EZ700 Intelligent Relays<br />

Description Inputs Outputs Catalog<br />

24V AC 110 – 240V 12V DC 24V DC Analog Relay Transistor<br />

Number<br />

AC<br />

Price<br />

U.S. $<br />

18 I/O, Clock, Display<br />

18 I/O, Clock, No Display<br />

18 I/O, Clock, Display<br />

18 I/O, Clock, No Display<br />

18 I/O, Clock, Display<br />

18 I/O, Clock, No Display<br />

18 I/O, Clock, Display<br />

18 I/O, Clock, No Display<br />

20 I/O, Clock, Display<br />

20 I/O, Clock, No Display<br />

12<br />

12<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

12<br />

12<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

12<br />

12<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

12<br />

12<br />

12<br />

12<br />

4<br />

4<br />

—<br />

—<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

8<br />

8<br />

EZ719-AB-RC<br />

EZ719-AB-RCX<br />

EZ719-AC-RC<br />

EZ719-AC-RCX<br />

EZ719-DA-RC<br />

EZ719-DA-RCX<br />

EZ719-DC-RC<br />

EZ719-DC-RCX<br />

EZ721-DC-TC<br />

EZ721-DC-TCX<br />

218.<br />

187.<br />

218.<br />

187.<br />

218.<br />

187.<br />

218.<br />

187.<br />

218.<br />

187.<br />

Note: Analog inputs optional.<br />

EZ800 with Display<br />

EZ800 without Display<br />

Table 23. EZ800 Intelligent Relays<br />

Description Inputs Outputs Catalog<br />

110 – 240V 24V DC Analog Relay Transistor Analog<br />

Number<br />

AC<br />

Price<br />

U.S. $<br />

18 I/O, Clock, Display<br />

18 I/O, Clock, No Display<br />

18 I/O, Clock, Display<br />

18 I/O, Clock, No Display<br />

19 I/O, Clock, Display<br />

19 I/O, Clock, No Display<br />

20 I/O, Clock, Display<br />

20 I/O, Clock, No Display<br />

21 I/O, Clock, Display<br />

21 I/O, Clock, No Display<br />

12<br />

12<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

12<br />

12<br />

12<br />

12<br />

12<br />

12<br />

12<br />

12<br />

—<br />

—<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

—<br />

8<br />

8<br />

8<br />

8<br />

—<br />

—<br />

—<br />

—<br />

1<br />

1<br />

—<br />

—<br />

1<br />

1<br />

EZ819-AC-RC<br />

EZ819-AC-RCX<br />

EZ819-DC-RC<br />

EZ819-DC-RCX<br />

EZ820-DC-RC<br />

EZ820-DC-RCX<br />

EZ821-DC-TC<br />

EZ821-DC-TCX<br />

EZ822-DC-TC<br />

EZ822-DC-TCX<br />

345.<br />

301.<br />

345.<br />

301.<br />

385.<br />

342.<br />

345.<br />

301.<br />

385.<br />

342.<br />

Note: Analog inputs optional, analog outputs optional.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

CA05001001E<br />

For more information visit: www.eaton.com


22<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

May 2007<br />

+ + =<br />

EZD-80 EZD-CP8 EZD I/O EZD Assembly<br />

Table 24. EZD Displays (EZD-80) and EZD Controllers (EZD-CP8)<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

EZD, No Buttons EZD-80 116.<br />

EZD, Buttons EZD-80-B 126.<br />

EZD CPU with 24V DC, Power <strong>Supply</strong>, Clock EZD-CP8-ME 283.<br />

EZD CPU with 24V DC, Power <strong>Supply</strong>, Clock, EZ-Net EZD-CP8-NT 342.<br />

EZD CPU with 100 – 240V AC, Power <strong>Supply</strong>, Clock EZD-AC-CP8-ME 283.<br />

EZD CPU with 100 – 240V AC, Power <strong>Supply</strong>, Clock, EZ-Net EZD-AC-CP8-NT 342.<br />

EZD-CP4-800 Attached to EZ-80 Display and EZ800 Unit<br />

EZ 500/700/800/EZD Intelligent Relays<br />

Table 25. EZD Display to EZ Communication Modules (EZD-CP4)<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

EZD Display to EZ500/700 DC Communication Module with EZ500/700<br />

Communication Cable (EZD-CP4-500-CAB5)<br />

EZD Display to EZ800 DC Communication Module with EZ800<br />

Communication Cable (EZD-CP4-800-CAB5)<br />

EZD Display to EZ500/700 AC Communication Module with EZ500/700<br />

Communication Cable (EZD-CP4-500-CAB5)<br />

EZD Display to EZ800 AC Communication Module with EZ800<br />

Communication Cable (EZD-CP4-800-CAB5)<br />

EZD-CP4-500 104.<br />

EZD-CP4-800 104.<br />

EZD-AC-CP4-500 160.<br />

EZD-AC-CP4-800 160.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

23<br />

Technical Data and Specifications<br />

Table 26. EZ500 Series<br />

Type EZ512-AB… EZ512-AC… EZ512-DA… EZ512-DC-R… EZ512-DC-TC.<br />

<strong>Supply</strong> Voltage 24V AC 100 – 240V AC 12V DC 24V DC 24V DC<br />

Heat Dissipation 5 VA 5 VA 2 W 2 W 2 W<br />

Continuous Current Outputs (1) 8 A 8 A 8 A 8 A 0.5 A<br />

Short-circuit Proof with Power Factor 1 Line Protection B16, 600 A —<br />

Short-circuit Proof with Power Factor 0.7…0.7 Line Protection B16, 900 A —<br />

Mounting<br />

On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />

Table 27. EZ700 Series<br />

Type EZ719-AB… EZ719-AC… EZ719-DA… EZ719-DC-RC. EZ721-DC-TC.<br />

<strong>Supply</strong> Voltage 24V AC 100 – 240V AC 12V DC 24V DC 24V DC<br />

Heat Dissipation 7 VA 10 VA 3.5 W 3.5 W 3.5 W<br />

Continuous Current Outputs (1) 8 A 8 A 8 A 8 A 0.5 A<br />

Short-circuit Proof with Power Factor 1 Line protection B16, 600 A —<br />

Short-circuit Proof with Power Factor 0.7…0.7 Line protection B16, 900 A —<br />

Mounting<br />

On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />

Table 28. EZ800 Series<br />

Type EZ819-AC… EZ819-DC-RC. EZ820-DC-RC. EZ821-DC-TC. EZ822-DC-TC.<br />

<strong>Supply</strong> Voltage 100 – 240V AC 24V DC 24V DC 24V DC 24V DC<br />

Heat Dissipation 10 VA 3.4 W 3.4 W 3.4 W 3.4 W<br />

Continuous Current Outputs (1) 8 A 8 A 8 A 8 A 0.5 A<br />

Short-circuit Proof with Power Factor 1 Line protection B16, 600 A —<br />

Short-circuit Proof with Power Factor 0.7…0.7 Line protection B16, 900 A —<br />

Mounting<br />

On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />

Table 29. EZD CP4 and CP8 Modules<br />

Type EZD-80… EZD-CP4-… EZD-CP8… EZD-AC-CP8…<br />

<strong>Supply</strong> Voltage <strong>Supply</strong> from -CP 24V DC 24V DC 100 – 240V AC<br />

Heat Dissipation 3 W 1.5 W 3 W 8 VA<br />

Mounting<br />

Front Mounting in<br />

2 x 22.5 mm Standard<br />

Drill Holes<br />

Snap Fitted to EZD-80 Snap Fitted to EZD-80 or on Top-hat Rail to<br />

DIN 50022, 35 mm or Screw Mounting with<br />

EZB4-101-GF1 Fixing Brackets<br />

Table 30. EZ500, EZ700, EZ800, EZD-80, EZD-CP4, EZD-CP8 Modules<br />

Type EZD-80… EZ500/700/800, EZD-CP4/CP8<br />

Connection Cables — 0.2 – 4.0 mm2 (AWG 22-12), solid<br />

0.2 - 2.5 mm2 (AWG 22-12), flexible<br />

Degree of Protections IP65 IP 20<br />

RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4 EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />

Ambient Operating Temperature Clearly Legible at -5 to 50ºC -25 to 55ºC<br />

Transport and Storage Temperature -40 to 70ºC -40 to 70ºC<br />

Certification, Standards EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />

CA05001001E<br />

For more information visit: www.eaton.com


24<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

May 2007<br />

Dimensions<br />

EZ500<br />

0.42<br />

(10.8)<br />

1.97<br />

(50.0)<br />

1.77<br />

(45.0)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.28<br />

(58.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.41<br />

(35.8)<br />

2.81<br />

(71.5)<br />

Figure 18. EZ500 Series Dimensions in Inches (mm), Drawing Number MD05013001E<br />

EZ600<br />

EZ700<br />

0.64<br />

(16.3)<br />

2.96<br />

(75.0)<br />

0.64<br />

(16.3)<br />

3.54<br />

(90.0)<br />

1.77<br />

(45.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.28<br />

(58.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

4.23<br />

(107.5)<br />

Figure 19. EZ600 and EZ700 Series Dimensions in Inches (mm), Drawing Number MD05013002E<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

25<br />

EZ800<br />

0.64<br />

(16.3)<br />

2.96<br />

(75.0)<br />

0.64<br />

(16.3)<br />

3.54<br />

(90.0)<br />

1.77<br />

(45.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.91<br />

(48.5)<br />

2.78<br />

(70.5)<br />

2.83<br />

(72.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

4.23<br />

(107.5)<br />

Figure 20. EZ800 Series Dimensions in Inches (mm), Drawing Number MD05013003E<br />

EZD-80<br />

0.89<br />

(22.5)<br />

EZD-80<br />

0.67<br />

(17.0)<br />

1.26<br />

(32.0)<br />

3.41<br />

(86.5)<br />

0.88 +0.02<br />

(22.3) +0.4<br />

1.18<br />

(30.0)<br />

EZD-CP...<br />

1.11<br />

(28.3)<br />

±0.01<br />

±0.2<br />

2.44<br />

(62.0)<br />

1.11<br />

(28.3)<br />

0.79<br />

(20.0)<br />

0.54<br />

(13.7)<br />

1.18<br />

(30.0)<br />

3.41<br />

(86.5)<br />

Template for Holes, Scale 1:1<br />

Figure 21. EZD-80 Series Dimensions in Inches (mm), Drawing Number MD05013005E<br />

CA05001001E<br />

For more information visit: www.eaton.com


26<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ 500/700/800/EZD Intelligent Relays<br />

May 2007<br />

EZD-CP8<br />

0.64<br />

(16.3)<br />

2.95<br />

(75.0)<br />

0.640<br />

(16.3)<br />

3.54<br />

(90.0)<br />

1.53<br />

(38.8)<br />

1.18 ±0.01<br />

(30.0) ±0.2<br />

4.23<br />

(107.5)<br />

1.53<br />

(38.8)<br />

0.18<br />

(4.5)<br />

1.16<br />

(29.5)<br />

Figure 22. EZD-CP8 Series Dimensions in Inches (mm), Drawing Number MD05013006E<br />

1-6<br />

-0.24<br />

(0.04)<br />

EZD-80<br />

EZD-CP4<br />

0.81<br />

(20.5)<br />

1.70<br />

(43.2)<br />

EZD-CP4<br />

EZD-CP4<br />

2.28<br />

(58.0)<br />

1.08<br />

(27.5)<br />

0.89<br />

(22.5)<br />

1.18<br />

(30.0)<br />

0.89<br />

(22.5)<br />

1.43<br />

(36.2)<br />

2.95<br />

(75.0)<br />

Figure 23. EZD-CP4, EZD-80 and EZD-CP4 Series Combined Dimensions in Inches (mm), Drawing Number MD013013E<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZD Controller I/O Modules<br />

27<br />

EZD Controller I/O Modules<br />

Product Selection<br />

Table 31. EZD Controller I/O Modules<br />

Description Inputs Outputs Catalog<br />

110 – 240V AC 24V DC Analog Relay Transistor Analog<br />

Number<br />

Price<br />

U.S. $<br />

16 I/O<br />

16 I/O<br />

17 I/O<br />

16 I/O<br />

17 I/O<br />

12<br />

—<br />

—<br />

—<br />

—<br />

—<br />

12<br />

12<br />

12<br />

12<br />

—<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

—<br />

—<br />

—<br />

—<br />

—<br />

4<br />

4<br />

—<br />

—<br />

1<br />

—<br />

1<br />

EZD-AC-R16<br />

EZD-R16<br />

EZD-RA17<br />

EZD-T16<br />

EZD-TA17<br />

120.<br />

120.<br />

156.<br />

120.<br />

156.<br />

Note: Analog inputs optional.<br />

Technical Data and Specifications<br />

Table 32. EZD Specifications<br />

Type EZD-AC-R16 EZD-R16 EZD-RA17 EZD-T16 EZD-TA17<br />

<strong>Supply</strong> Voltage<br />

<strong>Supply</strong> via EZD-CP8 module<br />

Heat Dissipation 0.5 W 0.5 W 0.5 W 0.5 W 0.5 W<br />

Continuous Current Outputs 8 A 8 A 8 A 0.5 A 0.5 A<br />

Short-circuit Proof with Power Factor 1 Line protection B16, 600 A — —<br />

Short-circuit Proof with Power Factor 0.7…0.7 Line protection B16, 900 A — —<br />

Connection Cables<br />

0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />

0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />

Degree of Protections IP 20 IP 20 IP 20 IP 20 IP 20<br />

RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />

Ambient Operating Temperature -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC<br />

Transport and Storage Temperature -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC<br />

Certification, Standards<br />

EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />

Mounting<br />

Snap Fitted to EZD-CP8 Module<br />

Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A/24V DC, max 4 outputs switchable in parallel.<br />

Dimensions<br />

EZD-R<br />

EZD-T I/O<br />

3.54<br />

(90.0)<br />

3.47<br />

(88.1)<br />

0.75<br />

(19.0)<br />

0.98<br />

(25.0)<br />

Figure 24. EZD-R/EZD-T I/O Module Dimensions in Inches (mm), Drawing Number MD05013007E<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

CA05001001E<br />

For more information visit: www.eaton.com


28<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Expansion Modules<br />

May 2007<br />

EZ/EZD Expansion Modules<br />

EZ/EZD Expansion Modules<br />

Product Description<br />

Expansion modules are available for<br />

increasing the input/output of the<br />

EZ700/800 and EZD intelligent relays to<br />

24 inputs and up to 16 outputs. Expansion<br />

modules can be mounted directly<br />

to the EZ/EZD unit or up to 98 ft. (30 m)<br />

away using coupling module EZ200-EZ.<br />

Product Selection<br />

Table 33. EZ/EZD I/O Expansion Modules <br />

Description Inputs Outputs Catalog<br />

110 – 240V 24V DC RY TRN Number<br />

AC<br />

All expansion modules include one EZ-LINK-DS.<br />

Technical Data and Specifications<br />

Table 34. EZ Specifications<br />

Relay = 8A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A/24V DC,<br />

max 4 outputs switchable in parallel.<br />

Dimensions<br />

Price<br />

U.S. $<br />

2 I/O Expansion — — 2 — EZ202-RE 52.<br />

18 I/O Expansion 12 — 6 — EZ618-AC-RE 152.<br />

18 I/O Expansion — 12 6 — EZ618-DC-RE 152.<br />

20 I/O Expansion — 12 — 8 EZ620-DC-TE 152.<br />

Coupling Module for Remote Mounting of Expansion Modules EZ200-EZ 41.<br />

Type EZ202-RE EZ618-AC-RE EZ618-DC-RE EZ620-DC-TE EZ200EZ<br />

<strong>Supply</strong> Voltage — 100 – 240V AC 24V AC 24V AC —<br />

Heat Dissipation 1 W 10 VA 4 W 4 W 1 W<br />

Continuous<br />

8 A 8 A 8 A 0.5 A —<br />

Current Outputs <br />

Short-circuit Proof Line Protection B16, 600 A —<br />

with Power Factor 1<br />

Short-circuit Proof with Line Protection B16, 900 A —<br />

Power Factor 0.7…0.7<br />

Connection Cables 0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />

0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />

Degree of Protections IP 20 IP 20 IP 20 IP 20 IP 20<br />

RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />

Ambient Operating -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC<br />

Temperature<br />

Transport and Storage -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC<br />

Temperature<br />

Certification, Standards EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />

Mounting<br />

On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with<br />

EZB4-101-GF1 Fixing Brackets<br />

EZ600<br />

EZ700<br />

0.64<br />

(16.3)<br />

2.96<br />

(75.0)<br />

0.64<br />

(16.3)<br />

3.54<br />

(90.0)<br />

1.77<br />

(45.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.28<br />

(58.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

4.23<br />

(107.5)<br />

Figure 25. EZ600 and EZ700 Series Dimensions in Inches (mm), Drawing Number MD05013002E<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Expansion Modules<br />

29<br />

EZ202-RE<br />

EZ200-EZ<br />

EZ205-ASI<br />

0.30<br />

(7.5)<br />

3.54<br />

(90.0)<br />

1.77<br />

(45.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.28<br />

(58.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.40<br />

(35.5)<br />

0.30<br />

(7.5)<br />

Figure 26. EZ202-RE/EZ200-EZ/EZ205-ASI Series Dimensions in Inches (mm), Drawing Number<br />

MD05013012E<br />

CA05001001E<br />

For more information visit: www.eaton.com


30<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Communication Modules<br />

May 2007<br />

EZ/EZD Communication<br />

Modules<br />

Product Selection<br />

Table 35. EZ/EZD Communication Interface Modules<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

PROFIBUS-DP Slave Interface Module EZ204-DP 257.<br />

AS-Interface Slave with 4 In and<br />

EZ205-ASI 94.<br />

4 Out Interface Module<br />

CANopen Interface Module EZ221-CO 247.<br />

DeviceNet Slave Interface Module EZ222-DN 247.<br />

Ethernet/IP Gateway EZ209-SE 289.<br />

Technical Data and Specifications<br />

Table 36. EZ/EZD Specifications<br />

Type EZ204-DP EZ205-ASI EZ221-CO EZ222-DN<br />

EZ204-DP Communication Module<br />

Product Description<br />

Four modules are available for easily<br />

connecting to world-standard networks.<br />

The communication modules<br />

can be used with the EZ700/800 and<br />

EZD intelligent relays.<br />

Available communication modules<br />

support:<br />

■ PROFIBUS-DP<br />

■ AS-I (Actuator Sensor Interface)<br />

networks<br />

■ CANopen<br />

■ DeviceNet<br />

■ Ethernet/IP<br />

All modules act as a gateway and<br />

operate exclusively as a slave station<br />

on the network.<br />

<strong>Supply</strong> Voltage 24V DC 24V DC 24V DC 24V DC<br />

Heat Dissipation 2 W 1 W 1 W 1 W<br />

Connection Cables<br />

0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />

0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />

Degree of Protections IP 20 IP 20 IP 20 IP 20<br />

RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />

Ambient Operating Temperature -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC<br />

Transport and Storage Temperature -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC<br />

Certification, Standards<br />

EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />

Mounting<br />

On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting<br />

with EZB4-101-GF1 Fixing Brackets<br />

Dimensions<br />

EZ221-CO<br />

EZ222-DN<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.77<br />

(45.0)<br />

0.30<br />

(7.5)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.64<br />

(67.0)<br />

1.40<br />

(35.5)<br />

0.30<br />

(7.5)<br />

Figure 27. EZ221-CO/EZ222-DN Series Dimensions in Inches (mm), Drawing Number<br />

MD05013010E<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ Software<br />

31<br />

EZ204-DP<br />

0.30<br />

(7.5)<br />

EZ Software<br />

1.77<br />

(45.0)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.44<br />

(62.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.40<br />

(35.5)<br />

0.30<br />

(7.5)<br />

Figure 28. EZ204-DP Series Dimensions in Inches (mm), Drawing Number MD05013011E<br />

EZ202-RE<br />

EZ200-EZ<br />

EZ205-ASI<br />

0.30<br />

(7.5)<br />

EZSoft Software<br />

Product Description<br />

The EZSoft software is used to program<br />

all of the EZ and EZD controllers and<br />

displays. The Windows-based software<br />

provides straightforward circuit diagram<br />

input and editing and the diagrams<br />

can be displayed in the format desired.<br />

When EZ800 and EZD controllers are<br />

connected using EZ-NET, all connected<br />

devices can be accessed and their programs<br />

loaded from a single controller.<br />

EZSoft includes an integrated offline<br />

simulation tool that allows users to<br />

test a circuit diagram before commissioning.<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.28<br />

(58.0)<br />

1.77<br />

(45.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.40<br />

(35.5)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

0.30<br />

(7.5)<br />

4.33<br />

(110.0)<br />

Product Selection<br />

Table 37. EZ/EZD Software<br />

Description<br />

Catalog<br />

Number<br />

Programming Software<br />

for EZ500/700/800 and<br />

EZD<br />

Price<br />

U.S. $<br />

EZSOFT 195.<br />

Figure 29. EZ202-RE/EZ200-EZ/EZ205-ASI Series Dimensions in Inches (mm), Drawing Number<br />

MD05013012E<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

CA05001001E<br />

For more information visit: www.eaton.com


32<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Power Supplies<br />

May 2007<br />

EZ/EZD Power Supplies<br />

Product Selection<br />

Table 38. EZ/EZD-CP8 Power Supplies<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

100 – 240V AC Input to 12V DC at 20 mA/24V DC at 250 mA EZ200-POW 41.<br />

100 – 240V AC Input to 24V DC at 1.25 A EZ400-POW 68.<br />

Technical Data and Specifications<br />

Table 39. EZ Specifications<br />

Type EZ200-POW EZ400-POW<br />

<strong>Supply</strong> Voltage 100 – 240V AC 100 – 240V AC<br />

Maximum Range 85 – 264V AC 85 – 264V AC<br />

Output Voltage 24V DC (±3%) 24V DC (±3%)<br />

Output Current (Rated Value) 0.25 A 1.25 A<br />

Overcurrent Limitation Form 0.3 A 1.4 A<br />

Short-circuit Proof (Secondary) YES YES<br />

Overload Proof YES YES<br />

Potential Isolation (prim/sec.) YES, SELV, (to EN 600950, VDE 805) YES, SELV, (to EN 600950, VDE 805)<br />

Others Additional Output Voltage 12 dc, 20 mA Additional Output Voltage 12 dc, 20 mA<br />

Connection Cables<br />

0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />

0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />

0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />

0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />

Degree of Protections IP 20 IP 20<br />

RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1, 2, 3, 4 EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1, 2, 3, 4<br />

Ambient Operating Temperature -25 to 55ºC -25 to 55ºC<br />

Transport and Storage Temperature -40 to 70ºC -40 to 70ºC<br />

Certification, Standards EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />

Mounting<br />

On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />

Dimensions<br />

0.42<br />

(10.8)<br />

EZ400-POW<br />

1.97<br />

(50.0)<br />

EZ200-POW<br />

EZ256-HCI<br />

0.30<br />

(7.5)<br />

1.77<br />

(45.0)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

1.41<br />

(35.8)<br />

2.81<br />

(71.5)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.40<br />

(35.5)<br />

0.30<br />

(7.5)<br />

Figure 30. EZ200-POW/EZ256-HCI and EZ400-POW Series Dimensions in Inches (mm), Drawing Number MD05013004E<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Accessories<br />

33<br />

EZ/EZD Accessories<br />

Table 42. EZ/EZD Cables and Connectors<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S.<br />

EZ700/500 Panel Window and Mounting Kit<br />

Product Selection<br />

Table 40. EZ/EZD Memory Storage Modules<br />

Description<br />

EZ500/700 32K<br />

Memory Storage<br />

Module<br />

EZ800/EZD 256K<br />

Memory Storage<br />

Module<br />

Table 41. EZ/EZD Programming Cables<br />

Description<br />

EZ500/700 to PC<br />

Cable<br />

EZ800/EZD to PC<br />

Cable<br />

Dimensions<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

EZ-M-32K 22.<br />

EZ-M-256K 33.<br />

Catalog<br />

Number<br />

EZ-PC-CAB<br />

EZ800-PC-CAB<br />

Price<br />

U.S. $<br />

56.<br />

82.<br />

EZ500/700 to EZD-CP4 Communication Cable, 5 m EZD-CP4-500-CAB5 50.<br />

EZ800 to EZD-CP8 Communication Cable, 2 m<br />

EZ800 to EZD-CP8 Communication Cable, 5 m<br />

EZ800 to EZD-CP4 Communication Cable, 5 m<br />

EZ800/EZD EZ-NET Cable, 0.3 m<br />

EZ800/EZD EZ-NET Cable, 0.8 m<br />

EZ800/EZD EZ-NET Cable, 1.5 m<br />

EZ800/EZD Network Termination Resistor, 2/Pack<br />

EZ800/EZD EZ-NET Cable (cable only, no connectors, see<br />

EZ-NT-RJ45), 100 m<br />

Table 43. EZ/EZD Miscellaneous Parts<br />

EZD-800-CAB<br />

EZD-800-CAB5<br />

EZD-CP4-800-CAB5<br />

EZ-NT-30<br />

EZ-NT-80<br />

EZ-NT-150<br />

EZ-NT-R<br />

54.<br />

92.<br />

50.<br />

9.<br />

14.<br />

21.<br />

25.<br />

EZ-NT-CAB 162.<br />

RJ45 Network Connectors for EZ-NET Cable (EZ-NT-CAB), 10/Pack EZ-NT-RJ45 4.<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S.<br />

EZ500 Relay Simulator EZ412-DC-SIM-NA 150.<br />

EZ500 Panel Window<br />

EZ700/800 Panel Window<br />

EZ500/700/800 Panel Window Mounting Kit to Front Mount Units<br />

EZ/EZD Panel Mount Brackets, 9/Pack<br />

EZ/EZD Grounding Kit<br />

EZD Display DIN Rail Mount Kit<br />

EZD Display Protective Membrane Cover<br />

EZD Display Protective Plastic Cover<br />

EZSKF-FF4<br />

EZSKF-FF6<br />

EZSKF-HA<br />

EZB4-101-GF1<br />

EZB4-102-KS1<br />

EZD-TS144<br />

EZD-XM-80<br />

EZD-XS-80<br />

EZ/EZD 6 Channel Noise Suppression Adapter EZ256-HCI 34.<br />

EZ/EZD Spare Interface Connector, Base to Expander EZ-LINK-DS 5.<br />

EZSoft Configuration Software EZSOFT 195.<br />

EZ Starter Kit (includes EZ512-DC-RC, EZ-PC-CAB,<br />

EZ412-DC-SIM-NA, EZSoft<br />

EZSTARTKIT1 475.<br />

18.<br />

21.<br />

9.<br />

13.<br />

17.<br />

10.<br />

28.<br />

28.<br />

0.42<br />

(10.8)<br />

EZ400-POW<br />

1.97<br />

(50.0)<br />

EZ200-POW<br />

EZ256-HCI<br />

0.30<br />

(7.5)<br />

1.77<br />

(45.0)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

3.54<br />

(90.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

1.41<br />

(35.8)<br />

2.81<br />

(71.5)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.40<br />

(35.5)<br />

0.30<br />

(7.5)<br />

Figure 31. EZ200-POW/EZ256-HCI and EZ400-POW Series Dimensions in Inches (mm), Drawing Number MD05013004E<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />

CA05001001E<br />

For more information visit: www.eaton.com


34<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Accessories<br />

May 2007<br />

EZD-XS-80<br />

EZD-XM-80<br />

3.74<br />

(95.0)<br />

3.48<br />

(88.5)<br />

3.41<br />

(86.5)<br />

0.98<br />

(25.0)<br />

3.48<br />

(88.5)<br />

0.89<br />

(22.5)<br />

Figure 32. EZD-XS-80 and EZD-XM-80 Series Dimensions in Inches (mm), Drawing Number MD05013009E<br />

EZ202-RE<br />

EZ200-EZ<br />

EZ205-ASI<br />

0.30<br />

(7.5)<br />

3.54<br />

(90.0)<br />

1.77<br />

(45.0)<br />

4.02<br />

(102.0)<br />

4.33<br />

(110.0)<br />

0.18<br />

(4.5)<br />

1.87<br />

(47.5)<br />

2.22<br />

(56.5)<br />

2.28<br />

(58.0)<br />

(M4)<br />

.157 DIA.<br />

(3.9)<br />

1.40<br />

(35.5)<br />

0.30<br />

(7.5)<br />

Figure 33. EZ202-RE/EZ200-EZ/EZ205-ASI Series Dimensions in Inches (mm), Drawing Number MD05013012E<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Accessories<br />

35<br />

SKF-FF4<br />

0.63<br />

(16.0)<br />

SKF-FF6<br />

0.63<br />

(16.0)<br />

2.99<br />

(76.0)<br />

2.99<br />

(76.0)<br />

3.70<br />

(94.0)<br />

0.98<br />

(25.0)<br />

5.12<br />

(130.0)<br />

0.98<br />

(25.0)<br />

Figure 34. EZSKF-FF4 and EZSKF-FF6 Series Dimensions in Inches (mm), Drawing Number MD05013014E<br />

EZSKF-HA<br />

0.43<br />

(11.0)<br />

1.89<br />

(48.0)<br />

2.60<br />

(66.0)<br />

3.23<br />

(82.0)<br />

Figure 35. EZSKF-HA Series Dimensions in Inches (mm), Drawing Number MD05013015E<br />

* 3 fixing feet sufficient<br />

* *<br />

Fitting on 35 mm Top-Hat Rail<br />

Figure 36. EZB4-101-GF1 Series<br />

* *<br />

Fitting on Mounting Plate (Horizontal)<br />

EZB4-101-GF1<br />

CA05001001E<br />

For more information visit: www.eaton.com


36<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Accessories<br />

May 2007<br />

Grounding the Screen for<br />

Top-Hat Rail<br />

Grounding the Screen for<br />

Mounting Plate<br />

Figure 37. EZB4-102-KS1 Series<br />

Connect Outputs<br />

Digital Inputs<br />

Connection<br />

Cable<br />

DEL<br />

ALT<br />

ESC<br />

OK<br />

Power <strong>Supply</strong><br />

Unit<br />

Figure 38. EZ412-DC-SIM-NA Series<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

EZ Intelligent Relays<br />

EZ/EZD Accessories<br />

37<br />

0.30 (7.5)<br />

1.77<br />

(45)<br />

3.54<br />

(90)<br />

4.02<br />

(102) (110)<br />

4.33<br />

1.77 (45)<br />

1.87 (47.5)<br />

M4<br />

2.22 (56.5) 1.40 (35.5)<br />

Figure 39. EZ256-HCI Dimensions in Inches (mm)<br />

Wiring Diagram<br />

L<br />

N<br />

> 1 A<br />

S..<br />

S..<br />

L<br />

N N I1 I2 I3 I4 I5<br />

.....<br />

N N 1 2<br />

115/230 Vh Input 115/230 Vh<br />

EZ5..-AC-..<br />

EZ7..-AC-..<br />

3 4 5 6<br />

EZ256-HCI<br />

Figure 40. EZ256-HCI Wiring Diagram<br />

CA05001001E<br />

For more information visit: www.eaton.com


38<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

May 2007<br />

IT. I/O <strong>Products</strong> D77A-DQ8, D77A-DI8<br />

and D77A-AQ8 with DeviceNet<br />

Adapter, D77D-DNA<br />

Product Description<br />

Cutler-Hammer ® Intelligent Technologies<br />

(IT.) D77A I/O Modules, which are<br />

built by Eaton’s electrical business for<br />

industrial applications, are available in<br />

8 and 16 point I/O, combination I/O and<br />

analog I/O. These modules are capable<br />

of connecting to AC or DC voltages<br />

and also to voltage or current analog<br />

I/O. Input modules have two points per<br />

isolated common while the outputs<br />

are available in relay and solid-state<br />

with two points per isolated common<br />

for most output modules. When added<br />

flexibility is needed, modules that<br />

combine inputs and outputs, AC, DC<br />

and relay are available.<br />

Application Description<br />

Typical D77A I/O Module applications<br />

use the D77A I/O as stand-alone<br />

remote I/O and in a system where<br />

motor control and I/O are required<br />

within a single customer panel.<br />

I/O and the motor control can be connected<br />

to a single network adapter.<br />

The network adapter then represents<br />

the D77A I/O and motor control as<br />

remote I/O, consuming only one network<br />

address. The network then controls<br />

and monitors the connected<br />

devices. Connecting devices is done<br />

by DIN rail back plane or by Plug-and-<br />

Play cables.<br />

D77D-DNA D77A I/O D77A I/O<br />

To Control<br />

PC or <strong>PLC</strong><br />

IT. Starters with QSNAPs<br />

Figure 41. Application — Distributed I/O and Motor Control<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

39<br />

Features, Functions and<br />

Benefits<br />

Scalable Solutions<br />

Since each application is different, the<br />

I/O offering has been designed to<br />

allow for maximum flexibility to tailor<br />

the I/O needs of our customer. The I/O<br />

product offering includes not only 8<br />

and 16 point modules but also combination<br />

I/O modules. Signal types<br />

include 24V DC I/O, 120V AC I/O, solidstate<br />

outputs, relay outputs, analog<br />

inputs and analog outputs.<br />

All Modules<br />

LED Status – When the LED is illuminated,<br />

the proper ON state signal is<br />

received at the input or the output point.<br />

Removable Lockable Terminals – To<br />

facilitate easy removal of the I/O<br />

module, the terminal block has been<br />

designed to be easily removed with<br />

the field wiring installed. A unique<br />

locking mechanism provides for easy<br />

removal of the terminal block and also<br />

positive locking of the terminal to the<br />

I/O module.<br />

Terminal Identification – Each terminal<br />

is marked for ease of wiring and troubleshooting.<br />

Isolation – Each I/O module is optically<br />

isolated between the field I/O and the<br />

network adapter.<br />

Securing Tabs – Each I/O module has a<br />

locking mechanism so that it can be<br />

positively secured to a DIN rail.<br />

Barrier Type Terminals – Each terminal<br />

has a barrier to minimize shorting of<br />

field wiring.<br />

Removal/Insertion – Each I/O module<br />

supports removal and insertion under<br />

power.<br />

Interconnection System – Each I/O<br />

module supports both a backplane<br />

style interconnect and a cable<br />

interconnect system for system<br />

communication.<br />

Points per Common – Each I/O module<br />

supports two I/O points per isolated<br />

common except for the DC output<br />

module which is four points per<br />

isolated common.<br />

Input Modules<br />

Input Filter – Each input module supports<br />

a user definable input debounce. The<br />

time can be set from 1 mS to 250 mS.<br />

Output Modules<br />

Output Safe State – Each output module supports a user definable safe state for<br />

loss of communication. The states are hold last state, ON or OFF (default).<br />

Configurable Power ON State – When the output module initially powers up and<br />

prior to system communication starting, the outputs can be preconfigured to go to<br />

a predefined state which can be ON or OFF (default).<br />

Operation<br />

When the D77A I/O Modules are properly installed and each has a properly configured<br />

Group ID, no configuration is needed for standard operation.<br />

Discrete Input Modules<br />

When a signal is present at the input point, the module responds using the following<br />

procedures:<br />

1. Optical Isolation – Optical isolation protects the I/O circuits and communication<br />

circuits from possible damage due to transients and overvoltage.<br />

2. Debounce Logic/Control – Debounce limits the effects of transients and electrical<br />

noise by requiring the input to be true for a certain period of time before<br />

the logic acknowledges a true signal. Once a true signal is achieved, the logic<br />

turns on the LED.<br />

Input<br />

Figure 42. Input Module Operation<br />

Discrete Output Modules<br />

When an output is commanded to change state, the module responds using the<br />

following procedures:<br />

1. Optical Isolation – Optical isolation protects the I/O circuits and communication<br />

circuits from possible damage due to transients and overvoltage. Once an<br />

active signal is sent to the optical isolation, the LED is activated.<br />

2. Output Drivers – The driver turns on the output point.<br />

Communication<br />

Adapter<br />

Optical<br />

Isolation<br />

LED<br />

Indication<br />

Figure 43. Output Module Operation<br />

Optical<br />

Isolation<br />

Debounce<br />

Logic/Control<br />

Output<br />

Drivers<br />

LED<br />

Indication<br />

Communication<br />

Adapter<br />

Output<br />

CA05001001E<br />

For more information visit: www.eaton.com


40<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

May 2007<br />

Analog Input Module<br />

The analog input module is single-ended uni-polar input type capable of measuring<br />

either voltage or current inputs. Each of the channels can be individually configured<br />

to be either one of the current scales or one of the voltage scales.<br />

Analog Output Module<br />

The analog output module is single-ended uni-polar output type capable of sourcing<br />

either voltage or current outputs. The analog output module requires a 24V DC<br />

source that will provide the current or voltage source for the outputs, each of the<br />

channels can be individually configured to be either one of the current scales or<br />

one of the voltage scales.<br />

Standards and Certifications<br />

Approvals<br />

Table 44. Approvals/Certifications<br />

Description<br />

Electrical/EMC<br />

ESD Immunity (<strong>IEC</strong> 61000-4-2)<br />

Radiated Immunity (<strong>IEC</strong> 61000-4-3)<br />

Fast Transient (<strong>IEC</strong> 61000-4-4)<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

RF Conducted (<strong>IEC</strong> 61000-4-6)<br />

Magnetic Field (<strong>IEC</strong> 61000-4-8)<br />

Voltage Dips (<strong>IEC</strong> 61000-4-11)<br />

Other Approvals<br />

Ingress Protection Code<br />

Radiated and Conducted Emissions<br />

Agency Certifications<br />

Specification<br />

± 8 kV air, ± 4 kV contact<br />

10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />

± 2 kV supply and control, ± 1 kV communications<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

10V, .15 – 80 MHz<br />

30A/m, 50 Hz<br />

30% dip @ 10 mS, 60% dip @ 100 mS, >95% interrupt @ 5 mS<br />

IP20<br />

EN 5011 Class A<br />

UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive)<br />

Technical Data and Specifications<br />

Table 45. Environmental Ratings<br />

Description<br />

Transportation & Storage<br />

Temperature<br />

Humidity<br />

Operating<br />

Temperature<br />

Humidity<br />

Altitude<br />

Shock <strong>IEC</strong> 68-2-27<br />

Vibration <strong>IEC</strong> 68-2-6<br />

Pollution Degree 2<br />

Enclosure<br />

IP20<br />

Specification<br />

-58° – 176°F (-50° – 80°C)<br />

5 – 95% non-condensing<br />

-13° – 131°F (-25° – 55°C) Discrete I/O<br />

-32° – 131°F (0° – 55°C) Analog I/O<br />

5 – 95% non-condensing<br />

Above 6,600 ft. (2000m) consult factory<br />

8G any direction for 11 mS<br />

10 – 55 Hz, 3G, .7 mm maximum peak-to-peak<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

41<br />

AC Input Modules — D77A-AI8, D77A-AI16<br />

Table 46. Specifications<br />

Description<br />

Nominal Input Voltage<br />

Operating Voltage<br />

Number of Inputs<br />

Points per Common 2<br />

OFF-State Voltage<br />

ON-State Voltage<br />

Nominal Input Current<br />

Signal Delay<br />

Specification<br />

120V AC<br />

80 – 140V AC<br />

8 (D77A-AI8)<br />

16 (D77A-AI16)<br />

< 30V AC<br />

> 80V AC<br />

15 mA<br />

1/2 Cycle<br />

Isolation 1,500V<br />

Module Current Draw 33 mA (D777-AI8), 46 mA (D77A-AI6)<br />

Terminal Screw Torque 7 – 9 in-lb<br />

Table 47. Operating Voltage Range — AC Input Modules<br />

OFF State Transition Region ON State<br />

0 30V AC 30V AC 80V AC 80V AC 140V AC<br />

AC Output Modules — D77A-AQ8, D77A-AQ16<br />

Table 48. Specifications<br />

Description<br />

Nominal Input Voltage<br />

Operating Voltage<br />

Number of Outputs<br />

Specification<br />

120V AC<br />

80 – 140V AC<br />

8 (D77A-AQ8)<br />

16 (D77A-AQ16)<br />

Points per Common 2<br />

Minimum Load Current (Resistive) 15 mA<br />

Maximum Current/Point (Resistive) .5A @ 30°C<br />

.1A @ 55°C<br />

Current per Module 4A (D77A-AQ8) @ 30°C<br />

8A (D77A-AQ16) @ 30°C<br />

Surge Current (10 ms)<br />

10A<br />

OFF-State Leakage<br />

2 mA<br />

Signal Delay<br />

1/2 Cycle<br />

Module Current Draw<br />

120 mA (D77A-AQ8)<br />

220 mA (D77A-AQ16)<br />

Terminal Screw Torque<br />

7 – 9 in-lb<br />

Table 49. Operating Voltage Range — AC Output Modules<br />

Transition Region<br />

ON State<br />

0 80V AC 80V AC 140V AC<br />

0<br />

8<br />

1<br />

9<br />

CR<br />

0<br />

CR<br />

8<br />

V AC<br />

C0<br />

V AC<br />

C4<br />

CR<br />

2<br />

CR<br />

9<br />

2<br />

10<br />

V AC<br />

C0<br />

V AC<br />

C4<br />

V AC<br />

3<br />

C1<br />

4<br />

V AC<br />

11<br />

C5<br />

12<br />

CR<br />

CR<br />

V AC<br />

CR<br />

2<br />

3<br />

C1<br />

4<br />

CR<br />

CR<br />

V AC<br />

CR<br />

10<br />

11<br />

C5<br />

12<br />

5<br />

13<br />

CR<br />

5<br />

CR<br />

13<br />

V AC<br />

C2<br />

V AC<br />

C6<br />

V AC<br />

C2<br />

V AC<br />

C6<br />

6<br />

14<br />

CR<br />

6<br />

CR<br />

14<br />

7<br />

15<br />

CR<br />

7<br />

CR<br />

15<br />

V AC<br />

C3<br />

V AC<br />

C7<br />

V AC<br />

C3<br />

V AC<br />

C7<br />

Figure 44. Wiring Diagram — AC Input Modules, D77A-AI8 & D77A-<br />

AI16<br />

Com<br />

Figure 46. Wiring Diagram — AC Output Modules, D77A-AQ8 &<br />

D77A-AQ16<br />

L2<br />

Out<br />

In<br />

In<br />

Figure 45. Circuit Diagram — AC Input Modules, D77A-AI8 &<br />

D77A-AI16<br />

Out<br />

Figure 47. Circuit Diagram — AC Output Modules, D77A-AQ8 &<br />

D77A-AQ16<br />

CA05001001E<br />

For more information visit: www.eaton.com


42<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

May 2007<br />

DC Input Modules — D77A-DI8, D77A-DI16<br />

Table 50. Specifications<br />

Description<br />

Nominal Input Voltage<br />

Operating Voltage<br />

Number of Inputs<br />

Specification<br />

24V DC<br />

18 – 30V DC<br />

8 (D77A-DI8)<br />

16 (D77A-DI16)<br />

Points per Common 2<br />

Signal Delay<br />

5 mS (Programmable to 250 mS)<br />

OFF-State Voltage<br />

< 6V DC<br />

ON-State Voltage<br />

> 18V DC<br />

Nominal Input Current<br />

5 mA<br />

Isolation<br />

1500V<br />

Module Current Draw<br />

35 mA (D77A-DI8)<br />

49 mA (D77A-DI16)<br />

Terminal Screw Torque<br />

7 – 9 in-lb<br />

Table 51. Operating Voltage Range — DC Input Modules<br />

OFF State Transition Region ON State<br />

0 6V DC 6V DC 18V DC 18V DC 30V DC<br />

DC Output Modules Sink — D77A-DQ8, D77A-DQ16<br />

Table 52. Specifications<br />

Description<br />

Specification<br />

Nominal Input Voltage<br />

24V DC<br />

Type<br />

MQSFET sink<br />

Operating Voltage<br />

18 – 30V DC<br />

Number of Outputs<br />

8 (D77A-DQ8)<br />

16 (D77A-DQ16)<br />

Points per Common 4<br />

Signal Delay<br />

1 mS<br />

Maximum Current/Point .75A<br />

Current per Module<br />

6A (D77D-DQ8)<br />

12A (D77D -DQ16)<br />

Surge Current (10 mS)<br />

4A<br />

OFF-State Leakage<br />

1 mA<br />

Module Current Draw<br />

85 mA (D77A-DQ8)<br />

126 mA (D77A-DQ16)<br />

Terminal Screw Torque<br />

7 – 9 in-lb<br />

Table 53. Operating Voltage Range — DC Output<br />

Transition Region<br />

ON State<br />

0<br />

8<br />

0 18V DC 18V DC 30V DC<br />

V DC<br />

V DC<br />

V DC<br />

V DC<br />

1<br />

C0<br />

2<br />

3<br />

C1<br />

4<br />

5<br />

C2<br />

6<br />

7<br />

C3<br />

V DC<br />

V DC<br />

V DC<br />

V DC<br />

9<br />

C4<br />

10<br />

11<br />

C5<br />

12<br />

13<br />

C6<br />

14<br />

15<br />

C7<br />

CR<br />

CR<br />

CR<br />

CR<br />

COM<br />

V DC<br />

CR<br />

CR<br />

CR<br />

CR<br />

COM<br />

0<br />

1<br />

2<br />

3<br />

–<br />

+<br />

4<br />

5<br />

6<br />

7<br />

–<br />

CR<br />

CR<br />

CR<br />

CR<br />

COM<br />

V DC<br />

CR<br />

CR<br />

CR<br />

CR<br />

COM<br />

8<br />

9<br />

10<br />

11<br />

–<br />

+<br />

12<br />

13<br />

14<br />

15<br />

–<br />

Figure 48. Wiring Diagram — DC Input Modules, D77A-DI8 &<br />

D77A-DI16<br />

In<br />

In<br />

V DC<br />

+<br />

V DC<br />

Figure 50. Wiring Diagram — DC Output Modules Sink, D77A-DQ8 &<br />

D77A-DQ16<br />

+<br />

+24<br />

Out<br />

Com<br />

Figure 49. Circuit Diagram — DC Input Modules, D77A-DI8 &<br />

D77A-DI16<br />

Out<br />

C<br />

Figure 51. Circuit Diagram — DC Output Modules Sink, D77A-DQ8 &<br />

D77A-DQ16<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

43<br />

DC Output Modules Source —<br />

D77A-DQ8C, D77A-DQ16C<br />

Table 54. DC Output Modules Specifications<br />

Description<br />

Specification<br />

Nominal Voltage<br />

24V DC<br />

Type<br />

MOSFET Source<br />

Operating Voltage<br />

18 – 30V DC<br />

Number of Outputs<br />

8 (D77A-DQ8C)<br />

16 (D77A-DQ16C)<br />

Points per Common 4<br />

Signal Delay<br />

1 mS<br />

Max. Current per Point .75A<br />

Max. Current per Module <br />

6A (D77A-DQ8C)<br />

12A (D77A-DQ16C)<br />

Surge Current (10 mS)<br />

4A<br />

OFF-State Leakage<br />

.5 mA<br />

Module Current Draw<br />

29 mA (D77A-DQ8C)<br />

45 mA (D77A-DQ16C)<br />

Resistive current at 55°C ambient.<br />

Relay Output Modules — D77A-RQ8, D77A-RQ16<br />

Table 55. Relay Output Modules Specifications<br />

Description<br />

Specification<br />

Nominal Voltage<br />

120V AC<br />

24V DC<br />

Number of Outputs<br />

8 (D77A-RQ8)<br />

16 (D77A-RQ16)<br />

Points per Common 2<br />

Relay OFF Time<br />

6 mS<br />

Relay ON Time<br />

3 mS<br />

Max. Current per Point <br />

3A<br />

Max. Current per Module 24A (D77A-RQ8)<br />

48A (D77A-RQ16)<br />

Electrical Life<br />

100,000 Cycles<br />

Mechanical Life<br />

1,000,000 Cycles<br />

Module Current Draw<br />

92 mA (D77A-RQ8)<br />

164 mA (D77A-RQ16)<br />

Resistive current at 55°C ambient.<br />

CR<br />

0<br />

CR<br />

8<br />

COM<br />

COM<br />

CR<br />

CR<br />

CR<br />

CR<br />

V DC<br />

CR<br />

CR<br />

CR<br />

CR<br />

0<br />

1<br />

2<br />

3<br />

–<br />

+<br />

4<br />

5<br />

6<br />

7<br />

–<br />

COM<br />

COM<br />

CR<br />

CR<br />

CR<br />

CR<br />

V DC<br />

CR<br />

CR<br />

CR<br />

CR<br />

0<br />

1<br />

2<br />

3<br />

–<br />

+<br />

4<br />

5<br />

6<br />

7<br />

–<br />

COM<br />

COM<br />

CR<br />

CR<br />

CR<br />

CR<br />

V DC<br />

CR<br />

CR<br />

CR<br />

CR<br />

8<br />

9<br />

10<br />

11<br />

–<br />

+<br />

12<br />

13<br />

14<br />

15<br />

–<br />

CR<br />

V AC/DC<br />

CR<br />

CR<br />

V AC/DC<br />

CR<br />

CR<br />

V AC/DC<br />

CR<br />

CR<br />

V AC/DC<br />

1<br />

C0<br />

2<br />

3<br />

C1<br />

4<br />

5<br />

C2<br />

6<br />

7<br />

C3<br />

CR<br />

V AC/DC<br />

CR<br />

CR<br />

V AC/DC<br />

CR<br />

CR<br />

V AC/DC<br />

CR<br />

CR<br />

V AC/DC<br />

9<br />

C4<br />

10<br />

11<br />

C5<br />

12<br />

13<br />

C6<br />

14<br />

15<br />

C7<br />

V DC<br />

D77A-DQ8C<br />

+<br />

V DC<br />

+<br />

V DC<br />

D77A-DQ16C<br />

+<br />

Figure 54. Wiring Diagram — Relay Output Modules, D77A-RQ8 &<br />

D77A-RQ16<br />

Figure 52. Wiring Diagram — DC Output Modules Source,<br />

D77A-DQ8C & D77A-DQ16C<br />

Out<br />

V DC<br />

Out<br />

Out (Q)<br />

V DC<br />

Out (Q)<br />

COM<br />

Figure 55. Circuit Diagram — Relay Output Modules, D77A-RQ8 &<br />

D77A-RQ16<br />

C<br />

Figure 53. Circuit Diagram — DC Output Modules Source,<br />

D77A-DQ8C & D77A-DQ16C<br />

CA05001001E<br />

For more information visit: www.eaton.com


44<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

May 2007<br />

AC Input AC Output Module — D77A-AI8AQ8<br />

Table 56. Specifications<br />

Description<br />

Resistive current at 55°C.<br />

Specification<br />

AC Input<br />

Table 57. Operating Voltage Range<br />

AC Output<br />

Nominal Voltage<br />

120V AC<br />

Operating Voltage<br />

80 – 140V AC<br />

Number of Points 8<br />

Points per Common 2<br />

Signal Delay<br />

1/2 Cycle<br />

(programmable<br />

to 250 mS)<br />

—<br />

OFF-State Voltage < 30V AC —<br />

ON-State Voltage > 80V AC —<br />

Nominal Current 15 mA —<br />

Signal Delay — 1/2 Cycle<br />

Max. Current per Point — .5A @ 30°C<br />

.1A @ 55°C<br />

Max. Current per<br />

Module — 4A @ 30°C<br />

.8A @ 55°C<br />

Surge Current (10 mS) — 10A<br />

OFF-State Leakage — 2 mA<br />

Isolation 1,500V<br />

Module Current Draw<br />

104 mA<br />

OFF State Transition Region ON State<br />

Input 0 30V AC 80V AC 140V AC<br />

Output 0V AC 80V AC 80V AC 140V AC<br />

0 CR 0<br />

1 CR<br />

V AC C0 V AC<br />

2 CR<br />

3 CR<br />

V AC C1 V AC<br />

4 CR<br />

5 CR<br />

V AC C2 V AC<br />

6 CR<br />

7 CR<br />

V AC C3 V AC<br />

Figure 56. Wiring Diagram — AC Input AC Output<br />

Com<br />

In<br />

In<br />

1<br />

C4<br />

2<br />

3<br />

C5<br />

4<br />

5<br />

C6<br />

6<br />

7<br />

C7<br />

L2<br />

Out<br />

Out<br />

Figure 57. Circuit Diagram — AC Input AC Output<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

45<br />

DC Input DC Output Module — D77A-DI8DQ8<br />

Table 58. Specifications<br />

Description<br />

Resistive current at 55°C.<br />

Specification<br />

DC Input<br />

Nominal Voltage<br />

24V DC<br />

Operating Voltage<br />

18 – 30V AC<br />

Number of Points 8<br />

Points per Common 2 4<br />

Signal Delay<br />

5 mS<br />

(programmable<br />

to 250 mS)<br />

—<br />

OFF-State Voltage < 6V DC —<br />

ON-State Voltage > 18V DC —<br />

Nominal Current 5 mA —<br />

Signal Delay — 1 mS<br />

Max. Current per Point — .75A<br />

Max. Current per<br />

— 6A<br />

Module <br />

Surge Current (10 mS) — 4A<br />

OFF-State Leakage — 1 mA<br />

Isolation 1,500V<br />

Module Current Draw<br />

99 mA<br />

Table 59. Operating Voltage Range — Input<br />

Table 60. Operating Voltage Range — Output<br />

DC Sink Output<br />

OFF State Transition Region ON State<br />

0 8V DC 8V DC 18V DC 18V DC 30V DC<br />

Transition Region<br />

ON State<br />

0 18V DC 18V DC 30V DC<br />

0 CR 0<br />

1 CR 1<br />

V DC C0 CR 2<br />

2 CR 3<br />

3 COM –<br />

V DC C1<br />

V DC<br />

+<br />

4 CR 4<br />

5 CR 5<br />

V DC C2 CR 6<br />

6 CR 7<br />

7 COM –<br />

V DC C3<br />

V DC<br />

+<br />

Figure 58. Wiring Diagram — DC Input DC Output<br />

In<br />

In<br />

Com<br />

Figure 59. Circuit Diagram — DC Input DC Output<br />

+24<br />

Out<br />

Out<br />

C<br />

CA05001001E<br />

For more information visit: www.eaton.com


46<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

May 2007<br />

AC Input Relay Output Module — D77A-AI8RQ8<br />

Table 61. Specifications<br />

Description<br />

Resistive current at 55°C.<br />

Specification<br />

AC Input<br />

Table 62. Operating Voltage Range — Input<br />

Relay Output<br />

Nominal Voltage 120V AC 120V AC<br />

24V DC<br />

Operating Voltage 80 – 140V AC 0 – 30V DC<br />

0 – 140V AC<br />

Number of Points 8<br />

Points per Common 2<br />

Signal Delay<br />

1/2 Cycle<br />

(programmable<br />

to 250 mS)<br />

—<br />

OFF-State Voltage < 30V AC —<br />

ON-State Voltage > 80V AC —<br />

Nominal Current 15 mA —<br />

Relay OFF Time — 6 mS<br />

Relay ON Time — 3 mS<br />

Max. Current per Point — 3A<br />

Max. Current per<br />

— 24A<br />

Module <br />

Electrical Life — 100,000 Cycles<br />

Mechanical Life — 1,000,000 Cycles<br />

Isolation 1,500V<br />

Module Current Draw<br />

104 mA<br />

OFF State Transition Region ON State<br />

0 30V AC 30V AC 80V AC 80V AC 140V AC<br />

0 CR 0<br />

1 CR<br />

V AC C0 V AC/DC<br />

2 CR<br />

3 CR<br />

V AC C1 V AC/DC<br />

4 CR<br />

5 CR<br />

V AC C2 V AC/DC<br />

6 CR<br />

7 CR<br />

V AC C3 V AC/DC<br />

1<br />

C0<br />

2<br />

3<br />

C1<br />

4<br />

5<br />

C2<br />

6<br />

7<br />

C3<br />

Figure 60. Wiring Diagram — AC Input Relay Output<br />

Com<br />

In<br />

In<br />

Out<br />

Out<br />

C<br />

Figure 61. Circuit Diagram — AC Input Relay Output<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

47<br />

DC Input Relay Output Module — D77A-DI8RQ8<br />

Table 63. Specifications<br />

Description<br />

Resistive current at 55°C.<br />

Specification<br />

DC Input<br />

Table 64. Operating Voltage Range — Input<br />

Relay Output<br />

Nominal Voltage 24V DC 120V AC<br />

24V DC<br />

Operating Voltage 18 – 30V DC 0 – 30V DC<br />

0 – 140V AC<br />

Number of Points 8<br />

Points per Common 2<br />

Signal Delay<br />

5 mS<br />

(programmable<br />

to 250 mS)<br />

—<br />

OFF-State Voltage < 6V DC —<br />

ON-State Voltage > 18V DC —<br />

Nominal Current 5 mA —<br />

Relay OFF Time — 6 mS<br />

Relay ON Time — 3 mS<br />

Max. Current per Point — 3A<br />

Max. Current per<br />

— 24A<br />

Module <br />

Electrical Life — 100,000 Cycles<br />

Mechanical Life — 1,000,000 Cycles<br />

Isolation 1,500V<br />

Module Current Draw<br />

106 mA<br />

OFF State Transition Region ON State<br />

0 8V DC 8V DC 18V DC 18V DC 30V DC<br />

0 CR 0<br />

1 CR<br />

V DC C4 V AC/DC<br />

2 CR<br />

3 CR<br />

V DC C5 V AC/DC<br />

4 CR<br />

5 CR<br />

V DC C6 V AC/DC<br />

6 CR<br />

7 CR<br />

V DC C7 V AC/DC<br />

1<br />

C0<br />

2<br />

3<br />

C1<br />

4<br />

5<br />

C2<br />

6<br />

7<br />

C3<br />

Figure 62. Wiring Diagram — DC Input Relay Output<br />

In<br />

In<br />

Com<br />

Out<br />

Out<br />

C<br />

Figure 63. Circuit Diagram — DC Input Relay Output<br />

CA05001001E<br />

For more information visit: www.eaton.com


48<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

May 2007<br />

Analog Input Module — D77A-NI4<br />

Table 65. D77A-NI4 — Specifications<br />

Description<br />

Specification<br />

Voltage Input<br />

0 – 5V DC, 1 – 5V DC, 0 – 10V DC<br />

Current Input<br />

4 – 20 mA, 0 – 20 mA<br />

Module Current Draw<br />

60 mA max.<br />

Input Types<br />

Single ended, Uni-polar<br />

Points 4<br />

Resolution Filter Setting Effective Resolution<br />

0 – 10V DC 0 – 5V DC, 1 – 5V DC / 4 – 20 mA, 0 – 20 mA<br />

50 Hz<br />

60 Hz<br />

250 Hz<br />

500 Hz<br />

14 bit<br />

14 bit<br />

13 bit<br />

13 bit<br />

Input Full Scale Voltage Current<br />

0 – 10.5V DC, 0 – 5.25V DC 0 – 21 mA<br />

Max Overload<br />

30V DC / 32 mA<br />

Input to Bus Isolation<br />

500V AC for 60 seconds<br />

Input Filter<br />

50 Hz, 60 Hz, 250 Hz, 500 Hz<br />

Common Mode Rejection > 60 dB @ 50 Hz and 60 Hz<br />

Normal Mode Rejection Ratio - 50 dB @ 50 Hz and 60 Hz<br />

Input Impedance Voltage Current<br />

15 M ohm 250 ohm<br />

Accuracy Voltage Current<br />

± 0.3% full scale @ 25°C<br />

± 0.4% full scale @ 0 – 55°C<br />

Update Rate Input Filter Update Time<br />

50 Hz<br />

60 Hz<br />

250 Hz<br />

500 Hz<br />

± 0.45% full scale @ 25°C<br />

± 0.5% full scale @ 0 – 55°C<br />

336 mS<br />

283 mS<br />

80 mS<br />

44 m S<br />

Input filter setting affects the effective resolution of channel.<br />

The time to update one channel when various filters are used within one module.<br />

14 bit<br />

14 bit<br />

12 bit<br />

9 bit<br />

Terminal<br />

1 V0<br />

Voltage<br />

Current<br />

2 I0<br />

i<br />

3 C0<br />

4 V1<br />

Earth ground<br />

Earth ground<br />

5<br />

I1<br />

i<br />

6 C1<br />

7 V2<br />

Earth ground<br />

Earth ground<br />

8 I2<br />

i<br />

9 C2<br />

Earth ground<br />

Earth ground<br />

10<br />

V3<br />

11<br />

I3<br />

i<br />

12<br />

C3<br />

Earth ground<br />

Earth ground<br />

Figure 64. D77A-NI4 Wiring Diagram<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series)<br />

49<br />

Analog Output Module — D77A-NQ2<br />

Table 66. D77A-NQ2 — Specifications<br />

Description<br />

Specification<br />

Voltage Output<br />

0 – 5V DC, 1 – 5V DC, 0 – 10V DC<br />

Current Output<br />

4 – 20 mA, 0 – 20 mA<br />

Module Current Draw<br />

40 mA max.<br />

External Power<br />

60A max. @ 24V DC<br />

Output Types<br />

Single ended, Uni-polar<br />

Protection<br />

Open and Short Circuit<br />

Points 2<br />

Resolution Range Resolution<br />

4 – 20 mA, 0 – 20 mA 14 bit<br />

0 – 10V DC 14 bit<br />

0 – 5V DC, 1 – 5V DC 13 bit<br />

Output Full Scale Voltage Current<br />

0 – 10.5V DC, 0 – 5.25V DC 0 – 21 mA<br />

Overvoltage Protection<br />

36V DC @ ± terminals<br />

Output to Bus Isolation<br />

1500V AC for 60 seconds<br />

Resistive Load on Current Output<br />

< 500 ohm<br />

Load Range on Voltage Output<br />

> 1 K ohm<br />

Max. Inductive Load<br />

0.1 mH<br />

Max. Capacitive Load 1 µF<br />

Output ripple (0 – 50 Hz) ± 0.1%<br />

Output Impedance<br />

10 ohm<br />

Accuracy Voltage Current<br />

0.8% full scale @ 25°C<br />

1% full scale @ 0 – 55°C<br />

Update Rate 350 µS<br />

0.8% full scale @ 25°C<br />

1% full scale @ 0 – 55°C<br />

Terminal<br />

1 V0<br />

2 I0<br />

0-5V, 1-5V, 0-10V wiring<br />

Voltage<br />

Load<br />

3 C0<br />

4 V1<br />

5 I1<br />

6 C1<br />

7 NC<br />

8 NC<br />

9 NC<br />

10 NC<br />

11<br />

12<br />

Earth ground<br />

Earth ground<br />

0-20 mA, 4-20 mA wiring<br />

External 24V DC<br />

Power <strong>Supply</strong><br />

Current<br />

Load<br />

Figure 65. D77A-NQ2 Wiring Diagram<br />

CA05001001E<br />

For more information visit: www.eaton.com


50<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Remote I/O Modules (D77A Series) — Accessories<br />

May 2007<br />

Dimensions<br />

Single<br />

Double<br />

Side<br />

2 (50.8)<br />

3.5<br />

(90)<br />

3.5<br />

(90)<br />

2<br />

(50.8)<br />

Module<br />

Module<br />

Module<br />

Module<br />

2 (50.8)<br />

Module<br />

2<br />

(50.8)<br />

Figure 67. I/O Module Ventilation —<br />

Approximate Dimensions in Inches (mm)<br />

.9<br />

(22.5)<br />

1.8<br />

(45)<br />

2.7<br />

(68)<br />

Figure 66. I/O Module — Approximate Dimensions in Inches (mm)<br />

Product Selection<br />

Table 67. D77A- I/O Module Product Selection<br />

Description<br />

Max.<br />

Output<br />

Current per<br />

Point<br />

Points per<br />

Common<br />

Size<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

8 Point 24V DC Input<br />

16 Point 24V DC Input<br />

8 Point 24V DC Solid-State Output<br />

16 Point 24V DC Solid-State Output<br />

8 Point 120V AC Input<br />

16 Point 120V AC Input<br />

8 Point 120V AC Solid-State Output<br />

16 Point 120V AC Solid-State Output<br />

8 Point Relay Output (24V DC/120V AC)<br />

16 Point Relay Output (24V DC/120V AC)<br />

8 Point 24V DC Input / 8 Point 24V DC Output<br />

8 Point 24V DC Input / 8 Point Relay Output<br />

8 Point 120V AC Input / 8 Point 120V AC Output<br />

8 Point Relay Output / 8 Point 120V AC Input<br />

4 Point Analog Input<br />

2 Point Analog Output<br />

N/A<br />

N/A<br />

.75 Amp<br />

.75 Amp<br />

N/A<br />

N/A<br />

.5 Amp<br />

.5 Amp<br />

3 Amp<br />

3 Amp<br />

.75 Amp<br />

3 Amp<br />

.5 Amp<br />

3 Amp<br />

N/A<br />

N/A<br />

2<br />

2<br />

4<br />

4<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2 (in), 4 (out)<br />

2 (in), 2 (out)<br />

2 (in), 2 (out)<br />

2 (in), 2 (out)<br />

4<br />

2<br />

Single<br />

Double<br />

Single<br />

Double<br />

Single<br />

Double<br />

Single<br />

Double<br />

Single<br />

Double<br />

Double<br />

Double<br />

Double<br />

Double<br />

Single<br />

Single<br />

D77A-DI8<br />

D77A-DI16<br />

D77A-DQ8<br />

D77A-DQ16<br />

D77A-AI8<br />

D77A-AI16<br />

D77A-AQ8<br />

D77A-AQ16<br />

D77A-RQ8<br />

D77A-RQ16<br />

D77A-DI8DQ8<br />

D77A-DI8RQ8<br />

D77A-AI8AQ8<br />

D77A-AI8RQ8<br />

D77A-NI4<br />

D77A-NQ2<br />

171.00<br />

227.00<br />

239.00<br />

299.00<br />

200.00<br />

268.00<br />

258.00<br />

411.00<br />

201.00<br />

381.00<br />

306.00<br />

314.00<br />

392.00<br />

345.00<br />

431.00<br />

431.00<br />

Accessories<br />

Table 68. I/O Module Product Accessories<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

7-Position Backplane with DIN Rail<br />

12-Position Backplane with DIN Rail<br />

25 cm Interconnect Plug-and-Play Cable<br />

1 Meter Interconnect Plug-and-Play Cable<br />

2 Meter Interconnect Plug-and-Play Cable<br />

3 Meter Interconnect Plug-and-Play Cable<br />

D77E-BP7<br />

D77E-BP12<br />

D77E-QPIP25<br />

D77E-QPIP100<br />

D77E-QPIP200<br />

D77E-QPIP300<br />

66.00<br />

90.00<br />

33.25<br />

38.75<br />

44.25<br />

49.75<br />

I/O Terminator DIN Style and Power Tap D77E-QPLR 99.50<br />

I/O Terminator RJ11 Style D77E-TERRJ 38.75<br />

Figure 68. Backplane with DIN Rail<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Starter Network Adapters (SNAP) (D77B Series) — DeviceNet SNAP<br />

51<br />

DeviceNet Starter Network<br />

Adapter Product (DSNAP)<br />

Catalog Number D77B-DSNAP-X3<br />

with 54 mm IT. Starter<br />

Product Description<br />

The Cutler-Hammer ® DeviceNet Starter<br />

Network Adapter Product (DSNAP)<br />

from Eaton’s electrical business is a<br />

front-mount device that serves as a<br />

single node on DeviceNet, providing<br />

communication capability, control and<br />

monitoring to Intelligent Technologies<br />

(IT.) Electromechanical Starters, as<br />

well as the S751 and S752 Soft Start,<br />

as listed in Tables 69 – 71.<br />

The IT. DSNAP has an optional HANDS/<br />

OFF/AUTO (HOA) module that enables<br />

the starter to be operated in hand<br />

mode; even if the DSNAP is not powered.<br />

The HOA option is used for customers<br />

who need the extra security of<br />

manual control in conjunction with the<br />

communication capabilities of<br />

DeviceNet.<br />

IT. Starter<br />

with<br />

DSNAP<br />

Figure 69. Typical DSNAP Application<br />

With the addition of a D64 zero<br />

sequence CT, the DSNAP can be<br />

enabled to detect ground faults for<br />

added protection.<br />

Features<br />

■ Communication to DeviceNet consuming<br />

one DeviceNet MAC ID<br />

■ Manually set MAC ID and baud rate;<br />

configuration using a software<br />

application is not required for normal<br />

operation<br />

■ Advanced configuration using<br />

CH Studio<br />

■ Includes pre-wired starter interconnect<br />

cable and terminal adapter<br />

Comprehensive Motor Data and<br />

Control<br />

■ RMS average current<br />

■ % of operating FLA<br />

■ % thermal memory<br />

■ Integral contact position detection<br />

■ Operating status and fault codes<br />

■ At speed (soft starters)<br />

■ START/STOP control<br />

■ RUN/FORWARD-REVERSE control<br />

■ Trip Reset<br />

Extended Starter Capabilities<br />

■ Ground fault detection (with<br />

accessory)<br />

■ Fault log<br />

■ Overcurrent warning (adjustable)<br />

■ Undercurrent warning (adjustable)<br />

DeviceNet<br />

Table 69. <strong>IEC</strong> SNAP Connectivity<br />

<strong>IEC</strong> E101, E501<br />

Frame Size Continuous<br />

Ampacity<br />

Rating<br />

45 mm B 18 Amp<br />

25 Amp<br />

32 Amp<br />

54 mm C 40 Amp<br />

50 Amp<br />

76 mm D 65 Amp<br />

85 Amp<br />

100 Amp<br />

105 mm E 125 Amp<br />

160 Amp<br />

200 Amp<br />

140 mm F 250 Amp<br />

315 Amp<br />

420 Amp<br />

Table 70. NEMA SNAP Connectivity<br />

NEMA N101, N501<br />

Size<br />

Continuous Ampacity<br />

Rating<br />

00 9<br />

0 18<br />

1 27<br />

2 45<br />

3 90<br />

4 135<br />

5 270<br />

Table 71. S751/S752 SNAP Connectivity<br />

S751/S752 Soft Start<br />

54 mm All Sizes<br />

Application Description<br />

In a typical application, the DSNAP<br />

front mounts to an IT. starter or soft<br />

start. The DSNAP connects directly to<br />

DeviceNet, allowing for control and<br />

monitoring of the starter/soft start. A<br />

PC or <strong>PLC</strong> serves as the central control<br />

and scans the DSNAP for motor control<br />

and monitoring information. The<br />

HOA module provides for the ability<br />

to locate operators on the panel for<br />

manual operation.<br />

CA05001001E<br />

For more information visit: www.eaton.com


52<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Starter Network Adapters (SNAP) (D77B Series) — DeviceNet SNAP<br />

May 2007<br />

Standards and Certifications<br />

Approvals<br />

Table 72. Approvals/Certifications<br />

Description<br />

Specification<br />

Electrical/EMC<br />

ESD Immunity<br />

± 8 kV air, ± 4 kV contact<br />

(<strong>IEC</strong> 61000-4-2)<br />

Radiated Immunity<br />

(<strong>IEC</strong> 61000-4-3)<br />

Fast Transient<br />

(<strong>IEC</strong> 61000-4-4)<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

RF Conducted<br />

(<strong>IEC</strong> 61000-4-6)<br />

Magnetic Field<br />

(<strong>IEC</strong> 61000-4-8)<br />

Voltage Dips<br />

(<strong>IEC</strong> 61000-4-11)<br />

Other Approvals<br />

Ingress Protection Code<br />

(<strong>IEC</strong> 60947-1)<br />

Radiated and Conducted<br />

Emissions<br />

Technical Data and Specifications<br />

Table 73. DeviceNet Specifications<br />

DeviceNet Connections Group 2 Slave<br />

Polling<br />

Explicit<br />

No UCMM<br />

10V/m 80 – 1,000 MHz, 80% amplitude<br />

modulation @ 1 kHz<br />

± 2 kV supply and control, ± 1 kV<br />

communications<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

10V, .15 – 80 MHz<br />

30A/m, 50 Hz<br />

30% dip @ 10 mS, 60% dip @ 100 mS,<br />

>95% interrupt @ 5 mS<br />

IP20<br />

EN 5011 Class A<br />

Agency Certifications UL 508, CUL (CSA C22.2 No. 14),<br />

CE (Low Voltage Directive),<br />

ODVA Conformance Tested<br />

DeviceNet Baud Rate<br />

125K, 250K, 500K<br />

Dimensions<br />

2.4<br />

(62)<br />

Figure 70. DSNAP Approximate Dimensions in Inches (mm)<br />

Product Selection<br />

Table 75. Product Selection<br />

Description<br />

Front<br />

1.0<br />

(26)<br />

Side<br />

1.9<br />

(49)<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

DSNAP Kit for FVNR Starters D77B-DSNAP-X1 335.00<br />

DSNAP Kit for FVR Starters D77B-DSNAP-X2 371.00<br />

DSNAP Kit for FVNR Starters with HOA D77B-DSNAP-X3 390.00<br />

DSNAP Kit for FVR Starters with HOA D77B-DSNAP-X4 458.00<br />

DSNAP Adapter for Size 5 and<br />

D77B-140A 47.25<br />

Size F Frame Starters<br />

SNAP Auxiliary Connector D77B-AC1 42.00<br />

Note: For D64 zero sequence CTs refer to Tab 49 in Publication No.<br />

CA08102001E.<br />

Table 74. Environmental Ratings<br />

Description<br />

Specifications<br />

Transportation/Storage<br />

Temperature<br />

-58° to 176°F (-50° to 80°C)<br />

Humidity<br />

5 – 95% non-condensing<br />

Operating<br />

Temperature<br />

-4° to 131°F (-20° to 55°C)<br />

Humidity<br />

5 – 95% non-condensing<br />

Altitude<br />

Above 2000 meters (6600 feet) consult factory<br />

Pollution Degree 2<br />

Power Draw<br />

90 mA Steady State<br />

Shock (<strong>IEC</strong> 68-2-27) 15G any direction for 11 mS<br />

Vibration (<strong>IEC</strong> 68-2-6) 5 – 150 Hz, 5G, .7 mm max. peak-to-peak<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Starter Network Adapters (SNAP) (D77B Series) — QCPort SNAP<br />

53<br />

QCPort Starter Network<br />

Adapter Product (QSNAP)<br />

Catalog Number D77B-QSNAP-X1<br />

with 54 mm IT. Starter<br />

Product Description<br />

The Cutler-Hammer ® QCPort Starter<br />

Network Adapter Product (QSNAP)<br />

from Eaton’s electrical business is a<br />

front-mount device providing communication<br />

capability, control and monitoring<br />

to Intelligent Technologies (IT.)<br />

Electromechanical Starters, as well as<br />

the S751 and S752 Soft Start, as listed<br />

in Tables 76 – 78. The QSNAP allows<br />

connection to any communications<br />

adapter and provides access to any<br />

support network.<br />

The IT. QSNAP has an optional HANDS/<br />

OFF/AUTO (HOA) module that enables<br />

the starter to be operated in hand<br />

mode; even if the QSNAP is not powered.<br />

The HOA option is used for customers<br />

who need the extra security of<br />

manual control in conjunction with<br />

industrial network communication<br />

capabilities.<br />

D77D-EIP, D77D-EMA,<br />

D77D-DNA, D77D-PNA<br />

To Control<br />

PC or <strong>PLC</strong><br />

With the addition of a D64 zero<br />

sequence CT, the QSNAP can be<br />

enabled to detect ground faults for<br />

added protection.<br />

Features<br />

■ Starter/contactor connectivity connecting<br />

motor control and I/O on<br />

same communication adapter<br />

■ Configuration using a software<br />

application is not required for normal<br />

operation<br />

■ Advanced configuration using<br />

CH Studio<br />

■ Includes pre-wired starter interconnect<br />

cable and terminal adapter<br />

Comprehensive Motor Data and<br />

Control<br />

■ RMS average current<br />

■ % of operating FLA<br />

■ % thermal memory<br />

■ Integral contact position detection<br />

■ Operating status and fault codes<br />

■ At speed (soft starters)<br />

■ START/STOP control<br />

■ RUN/FORWARD-REVERSE control<br />

■ Trip Reset<br />

Extended Starter Capabilities<br />

■ Ground fault detection (with<br />

accessory)<br />

■ Fault log<br />

■ Overcurrent warning (adjustable)<br />

■ Undercurrent warning (adjustable)<br />

■ Emergency stop detection<br />

IT. Starters with QSNAPs<br />

Table 76. <strong>IEC</strong> SNAP Connectivity<br />

<strong>IEC</strong> E101, E501<br />

Frame Size Continuous<br />

Ampacity<br />

Rating<br />

45 mm B 18 Amp<br />

25 Amp<br />

32 Amp<br />

54 mm C 40 Amp<br />

50 Amp<br />

76 mm D 65 Amp<br />

85 Amp<br />

100 Amp<br />

105 mm E 125 Amp<br />

160 Amp<br />

200 Amp<br />

140 mm F 250 Amp<br />

315 Amp<br />

420 Amp<br />

Table 77. NEMA SNAP Connectivity<br />

NEMA N101, N501<br />

Size<br />

Continuous Ampacity<br />

Rating<br />

00 9<br />

0 18<br />

1 27<br />

2 45<br />

3 90<br />

4 135<br />

5 270<br />

Table 78. S751/S752 SNAP Connectivity<br />

S751/S752 Soft Start<br />

54 mm All Sizes<br />

Application Description<br />

A typical application for the QSNAP<br />

will contain many QSNAPs and many<br />

I/O products all connected to a single<br />

network adapter. With this architecture,<br />

an entire panel can be represented<br />

by a single network adapter.<br />

Figure 71. Typical QSNAP Application<br />

CA05001001E<br />

For more information visit: www.eaton.com


54<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Starter Network Adapters (SNAP) (D77B Series) — QCPort SNAP<br />

May 2007<br />

Standards and Certifications<br />

Approvals<br />

Table 79. Approvals/Certifications<br />

Description<br />

Specification<br />

Electrical/EMC<br />

ESD Immunity<br />

± 8 kV air, ± 4 kV contact<br />

(<strong>IEC</strong> 61000-4-2)<br />

Radiated Immunity<br />

(<strong>IEC</strong> 61000-4-3)<br />

Fast Transient<br />

(<strong>IEC</strong> 61000-4-4)<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

RF Conducted<br />

(<strong>IEC</strong> 61000-4-6)<br />

Magnetic Field<br />

(<strong>IEC</strong> 61000-4-8)<br />

Voltage Dips<br />

(<strong>IEC</strong> 61000-4-11)<br />

Other Approvals<br />

Ingress Protection Code<br />

(<strong>IEC</strong> 60947-1)<br />

Radiated and Conducted<br />

Emissions<br />

Technical Data and Specifications<br />

Table 80. Environmental Ratings<br />

10V/m 80 – 1,000 MHz, 80% amplitude<br />

modulation @ 1 kHz<br />

± 2 kV supply and control, ± 1 kV<br />

communications<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

10V, .15 – 80 MHz<br />

30A/m, 50 Hz<br />

30% dip @ 10 mS, 60% dip @ 100 mS,<br />

>95% interrupt @ 5 mS<br />

IP20<br />

EN 5011 Class A<br />

Agency Certifications UL 508, CUL (CSA C22.2 No. 14),<br />

CE (Low Voltage Directive),<br />

ODVA Conformance Tested<br />

Description<br />

Transportation/Storage<br />

Temperature<br />

Humidity<br />

Operating<br />

Temperature<br />

Humidity<br />

Altitude<br />

Power Draw<br />

Shock (<strong>IEC</strong> 68-2-27)<br />

Vibration (<strong>IEC</strong> 68-2-6)<br />

Specifications<br />

-58° to 176°F (-50° to 80°C)<br />

5 – 95% non-condensing<br />

-13° to 149°F (-25° to 65°C)<br />

5 – 95% non-condensing<br />

Above 2000 meters (6600 feet) consult factory<br />

90 mA Steady State<br />

15G any direction for 11 mS<br />

5 – 150 Hz, 5G, .7 mm max. peak-to-peak<br />

Dimensions<br />

2.4<br />

(62)<br />

Figure 72. QSNAP Approximate Dimensions in Inches (mm)<br />

Product Selection<br />

Table 81. Product Selection<br />

Description<br />

Front<br />

1.0<br />

(26)<br />

Side<br />

1.2<br />

(32)<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

QSNAP Kit for FVNR Starters D77B-QSNAP-X1 301.00<br />

QSNAP Kit for FVR Starters D77B-QSNAP-X2 333.00<br />

QSNAP Kit for FVNR Starters with HOA D77B-QSNAP-X3 350.00<br />

QSNAP Kit for FVR Starters with HOA D77B-QSNAP-X4 350.00<br />

QSNAP Adapter for Size 5 and<br />

D77B-140A 47.25<br />

Size F Frame Starters<br />

SNAP Auxiliary Connector D77B-AC1 42.00<br />

Note: For D64 zero sequence CTs, refer to Tab 49 in Publication No.<br />

CA08102001E.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — DeviceNet Adapter<br />

55<br />

Cat. No. D77D-DNA<br />

Product Description<br />

The Cutler-Hammer ® Intelligent Technologies<br />

(IT.) DeviceNet Adapter<br />

(D77D-DNA) from Eaton’s electrical<br />

business has greatly increased the<br />

functionality of IT. communicating<br />

products, allowing monitoring and<br />

control for IT. I/O and IT. motor control<br />

devices. The adapter concentrates all<br />

data from these devices into a single<br />

DeviceNet node.<br />

To simplify the configuration of the<br />

D77D-DNA, a simple auto-configure<br />

button press sets the system up for<br />

default operation. This automatically<br />

configures the DeviceNet I/O assemblies<br />

to the system devices. The data<br />

from these devices is assembled into a<br />

single input and output message.<br />

Application Description<br />

In a typical DeviceNet Adapter application,<br />

the D77D-DNA connects directly<br />

to DeviceNet, and resides in a system<br />

with IT. I/O and other communicating<br />

motor controls. The data from these IT.<br />

devices is assembled into a single<br />

input and output message before<br />

being presented to DeviceNet.<br />

Features, Functions and Benefits<br />

■ Communication to DeviceNet<br />

consuming one DeviceNet MAC ID<br />

■ Provides for control of all IT. communicating<br />

devices connected to<br />

the gateway<br />

■ Manually set to MAC ID and baud<br />

rate; configuration using a software<br />

application is not required for normal<br />

operation<br />

■ Single button press auto configures<br />

the gateway, setting up the system<br />

for default operation<br />

■ Advanced configuration using<br />

CH Studio<br />

■ Provides for backplane and interconnect<br />

cable connections to I/O<br />

modules and motor control<br />

products<br />

Standards and Certifications<br />

Approvals<br />

■ Provides one I/O DeviceNet message<br />

representing all connected devices<br />

■ Two independent ports for Plugand-Play<br />

connection to I/O<br />

■ Powered from backplane<br />

■ Isolated from DeviceNet<br />

■ Status LEDs for DeviceNet and<br />

module health<br />

■ Provides for configuration of I/O<br />

devices over DeviceNet<br />

■ Small package size<br />

■ DIN rail mountable<br />

Table 82. Approvals/Certifications<br />

Description<br />

Specification<br />

Electrical/EMC<br />

ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />

Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />

Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />

Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />

Other Approvals<br />

Ingress Protection Code<br />

IP20<br />

Radiated and Conducted Emissions EN 5011 Class A<br />

Agency Certifications<br />

UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />

ODVA Conformance Tested<br />

CA05001001E<br />

For more information visit: www.eaton.com


56<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — DeviceNet Adapter<br />

May 2007<br />

Technical Data and<br />

Specifications<br />

Dimensions<br />

Table 83. DeviceNet Specifications<br />

Description<br />

Specification<br />

DeviceNet<br />

Connections<br />

Maximum<br />

DeviceNet I/O<br />

Size<br />

DeviceNet<br />

Baud Rate<br />

QCPort Channels<br />

Group 2,<br />

Polling, Bit Strobe,<br />

Explicit, No UCMM<br />

128 Bytes Input<br />

128 Bytes Output<br />

125K, 250K, 500K<br />

2 Independent<br />

Channels<br />

3.5<br />

(90)<br />

Table 84. Environmental Ratings<br />

Description<br />

Transportation/Storage<br />

Temperature<br />

Humidity<br />

Operating<br />

Temperature<br />

Humidity<br />

Altitude<br />

Shock<br />

(<strong>IEC</strong> 68-2-27)<br />

Vibration<br />

(<strong>IEC</strong> 68-2-6)<br />

Pollution Degree 2<br />

Specification<br />

-58° – 176°F (-50° – 80°C)<br />

5 – 95% non-condensing<br />

-13° – 131°F (-25° – 55°C)<br />

5 – 95% non-condensing<br />

Above 6,600 ft. (2,000m)<br />

consult factory<br />

15G any direction for<br />

11 mS<br />

5 – 150 Hz, 5G .7 mm<br />

maximum peak-to-peak<br />

Figure 73. D77D-DNA — Approximate Dimensions in Inches (mm)<br />

2<br />

(50.8)<br />

Module<br />

Module<br />

Module<br />

.9<br />

(22.5)<br />

2 (50.8)<br />

Module<br />

Module<br />

2<br />

(50.8)<br />

2.7<br />

(68)<br />

Product Selection<br />

Table 85. DeviceNet Adapter Product<br />

Selection<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

DeviceNet Adapter D77D-DNA 406.<br />

2 (50.8)<br />

Figure 74. D77D-DNA Module Ventilation —<br />

Approximate Dimensions in Inches (mm)<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — Modbus Adapter<br />

57<br />

Cat. No. D77D-EMA<br />

Product Description<br />

The Cutler-Hammer ® Intelligent Technologies<br />

(IT). Ethernet Modbus<br />

Adapter (D77D-EMA) from Eaton’s<br />

electrical business has greatly<br />

increased the functionality of Cutler-<br />

Hammer IT. communicating products,<br />

allowing monitoring and control for IT.<br />

I/O and IT. motor control devices. The<br />

adapter concentrates all data from<br />

these devices into a single Modbus<br />

node.<br />

The Modbus Adapter supports not<br />

only Modbus TCP but also Modbus<br />

serial (ASCII and RTU) as a slave<br />

device. This combination of the two<br />

physical layers provides for ultimate<br />

functionality when connecting to a<br />

Modbus system. A unique attribute of<br />

the D77D-EMA is that it supports Modbus<br />

serial Pass-Through. In this mode<br />

a customer can connect Modbus serial<br />

devices to one of the channels and<br />

monitor and control them over<br />

Modbus TCP.<br />

To simplify the configuration of the<br />

D77D-EMA, a simple auto-configure<br />

button press sets the system up for<br />

default operation. This automatically<br />

configures the Modbus registers to the<br />

I/O system devices.<br />

Application Description<br />

In a typical Modbus Adapter application,<br />

the D77D-EMA connects directly<br />

to Modbus, and resides in a system<br />

with IT. I/O and other communicating<br />

motor controls. The data from these<br />

IT. devices is assembled into input and<br />

output registers before being presented<br />

to Modbus.<br />

Features, Functions and Benefits<br />

■ Communication to Modbus<br />

consuming one address<br />

■ Supports Boot P and static IP<br />

addressing<br />

■ 10/100 BaseT Connection<br />

■ RS-485 Modbus slave serial<br />

connection<br />

■ Supports Serial Modbus Pass-<br />

Through over Modbus TCP<br />

■ Provides for control of all IT. communicating<br />

devices connected to<br />

the gateway<br />

■ Manually set to address and baud<br />

rate for serial Modbus; configuration<br />

using a software application is<br />

not required for normal operation<br />

■ Single button press auto configures<br />

the gateway, setting up the system<br />

for default operation<br />

Standards and Certifications<br />

Approvals<br />

Technical Data and Specifications<br />

Table 87. Environmental Ratings<br />

Description Specification<br />

Transportation/Storage<br />

Temperature -58° – 176°F (-50° – 80°C)<br />

Humidity 5 – 95% non-condensing<br />

Operating<br />

Temperature -13° –149 °F (-25° – 65°C)<br />

Humidity 5 – 95% non-condensing<br />

Altitude<br />

Above 6,600 ft. (2,000m)<br />

consult factory<br />

■ Advanced configuration using CH<br />

Studio<br />

■ Provides for backplane and interconnect<br />

cable connections to I/O<br />

modules and motor control<br />

products<br />

■ Two independent ports for Plugand-Play<br />

connection to I/O<br />

■ Powered from backplane<br />

■ Isolated from Modbus<br />

■ Status LEDs for Modbus and<br />

module health<br />

■ Provides for configuration of I/O<br />

devices over Modbus TCP<br />

■ Small package size<br />

■ DIN rail mountable<br />

Table 86. Approvals/Certifications<br />

Description<br />

Specification<br />

Electrical/EMC<br />

ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />

Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />

Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />

Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />

Other Approvals<br />

Ingress Protection Code<br />

IP20<br />

Radiated and Conducted Emissions EN 5011 Class A<br />

Agency Certifications<br />

UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />

Modbus Conformance Tested<br />

Shock<br />

(<strong>IEC</strong> 68-2-27)<br />

Vibration<br />

(<strong>IEC</strong> 68-2-6)<br />

Pollution Degree 2<br />

15G any direction for<br />

11 mS<br />

5 – 150 Hz, 5G .7 mm<br />

maximum peak-to-peak<br />

Table 88. Modbus Specifications<br />

Description Specification<br />

Connections<br />

I/O Size<br />

Baud<br />

Addressing<br />

Channels<br />

10/100 BaseT<br />

RS-485<br />

1024 Registers Input<br />

1024 Registers Output<br />

Ethernet 10 Megabit<br />

Serial 1200 to 115.2K baud<br />

Ethernet – Boot P or Static IP<br />

Serial – DIP Switch 1 – 255<br />

2 Independent<br />

Channels<br />

CA05001001E<br />

For more information visit: www.eaton.com


58<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — Modbus Adapter<br />

May 2007<br />

Dimensions<br />

3.5<br />

(90)<br />

.9<br />

(22.5)<br />

2.7<br />

(68)<br />

Figure 75. D77D-EMA — Approximate Dimensions in Inches (mm)<br />

2<br />

(50.8)<br />

Module<br />

Module<br />

Module<br />

2 (50.8)<br />

Module<br />

Module<br />

2<br />

(50.8)<br />

Product Selection<br />

Table 89. Modbus Adapter Product Selection<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

Modbus Adapter D77D-EMA 499.<br />

2 (50.8)<br />

Figure 76. D77D-EMA Module Ventilation —<br />

Approximate Dimensions in Inches (mm)<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — EtherNet/IP Adapter<br />

59<br />

Features, Functions and Benefits<br />

■ Communication to EtherNet/IP<br />

consuming one address<br />

■ Supports Boot P, DHCP and static<br />

IP addressing<br />

■ 10/100 BaseT Connection<br />

■ Provides for control of all IT. communicating<br />

devices connected to<br />

the network adapter<br />

■ Single button press auto configures<br />

the gateway, setting up the system<br />

for default operation<br />

■ Advanced configuration using<br />

CH Studio<br />

■ Provides for backplane and interconnect<br />

cable connections to I/O<br />

modules and motor control<br />

products<br />

■ Two independent ports for Plugand-Play<br />

connection to I/O<br />

■ Powered from backplane<br />

■ Isolated from EtherNet/IP<br />

■ Status LEDs for EtherNet/IP and<br />

module health<br />

■ Provides for configuration of I/O<br />

devices over EtherNet/IP<br />

■ Small package size<br />

■ DIN rail mountable<br />

Cat. No. D77D-EIP<br />

Product Description<br />

The Cutler-Hammer ® Intelligent Technologies<br />

(IT.) EtherNet/IP (D77D-EIP)<br />

from Eaton’s electrical business has<br />

greatly increased the functionality of<br />

Cutler-Hammer IT. communicating<br />

products, allowing monitoring and<br />

control for IT. I/O and IT. motor control<br />

devices. The adapter concentrates all<br />

data from these devices into a single<br />

EtherNet/IP node.<br />

The EtherNet/IP Adapter is a slave<br />

device on EtherNet/IP.<br />

To simplify the configuration of the<br />

D77D-EIP, a simple auto-configure<br />

button press sets the system up for<br />

default operation. This automatically<br />

configures the EtherNet/IP assemblies<br />

to the I/O system devices.<br />

Application Description<br />

In a typical EtherNet/IP Adapter application,<br />

the D77D-EIP connects directly<br />

to EtherNet/IP, and resides in a system<br />

with IT. I/O and other communicating<br />

motor controls. The data from these<br />

IT. devices is assembled into input and<br />

output assemblies before being presented<br />

to EtherNet/IP.<br />

Standards and Certifications<br />

Approvals<br />

Table 90. Approvals/Certifications<br />

Description<br />

Specification<br />

Electrical/EMC<br />

ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />

Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />

Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />

Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />

Other Approvals<br />

Ingress Protection Code<br />

IP20<br />

Radiated and Conducted Emissions EN 5011 Class A<br />

Agency Certifications<br />

UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />

Modbus Conformance Tested<br />

Technical Data and Specifications<br />

Table 91. Environmental Ratings<br />

Description Specification<br />

Transportation/Storage<br />

Temperature -58° – 176°F (-50° – 80°C)<br />

Humidity 5 – 95% non-condensing<br />

Operating<br />

Temperature -13° –149 °F (-25° – 65°C)<br />

Humidity 5 – 95% non-condensing<br />

Altitude<br />

Above 6,600 ft. (2,000m)<br />

consult factory<br />

Shock<br />

(<strong>IEC</strong> 68-2-27)<br />

Vibration<br />

(<strong>IEC</strong> 68-2-6)<br />

Pollution Degree 2<br />

15G any direction for<br />

11 mS<br />

5 – 150 Hz, 5G .7 mm<br />

maximum peak-to-peak<br />

Table 92. EtherNet/IP Specifications<br />

Description Specification<br />

Connections<br />

I/O Size<br />

Baud<br />

Addressing<br />

Channels<br />

10/100 BaseT<br />

504 bytes Input<br />

504 bytes Output<br />

Ethernet 10/100 Megabit<br />

Ethernet – Boot P, Static IP<br />

or DHCP<br />

2 Independent<br />

Channels<br />

CA05001001E<br />

For more information visit: www.eaton.com


60<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — EtherNet/IP Adapter<br />

May 2007<br />

Dimensions<br />

3.5<br />

(90)<br />

.9<br />

(22.5)<br />

2.7<br />

(68)<br />

Figure 77. D77D-EIP — Approximate Dimensions in Inches (mm)<br />

2<br />

(50.8)<br />

Module<br />

Module<br />

Module<br />

2 (50.8)<br />

Module<br />

Module<br />

2<br />

(50.8)<br />

Product Selection<br />

Table 93. EtherNet/IP Adapter Product<br />

Selection<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

Modbus Adapter D77D-EIP 510.<br />

2 (50.8)<br />

Figure 78. D77D-EIP Module Ventilation —<br />

Approximate Dimensions in Inches (mm)<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — PROFIBUS Adapter<br />

61<br />

Features, Functions and Benefits<br />

Cat. No. D77D-PNA<br />

■ Communication to PROFIBUS<br />

consuming one address<br />

■ Supports hardware addressing<br />

■ DB9 Connection<br />

■ Modbus slave connections on<br />

motherboard<br />

■ Provides for control of all IT. communicating<br />

devices connected to<br />

the network adapter<br />

■ PROFIBUS supports autobaud<br />

■ Single button press auto configures<br />

the gateway, setting up the system<br />

for default operation<br />

■ Advanced configuration using<br />

CH Studio<br />

■ Provides for backplane and interconnect<br />

cable connections to I/O<br />

modules and motor control<br />

products<br />

■ Two independent ports for Plugand-Play<br />

connection to I/O<br />

■ Powered from backplane<br />

■ Isolated from PROFIBUS<br />

■ Status LEDs for module health<br />

■ Provides for configuration of I/O<br />

devices over Modbus TCP<br />

■ Small package size<br />

■ DIN rail mountable<br />

Product Description<br />

The Cutler-Hammer ® Intelligent Technologies<br />

(IT.) PROFIBUS Adapter<br />

(D77D-PNA) from Eaton’s electrical<br />

business has greatly increased the<br />

functionality of Cutler-Hammer IT.<br />

communicating products, allowing<br />

monitoring and control for IT. I/O and<br />

IT. motor control devices. The adapter<br />

concentrates all data from these<br />

devices into a single node.<br />

The PROFIBUS Adapter supports not<br />

only PROFIBUS but also Modbus<br />

(ASCII and RTU) as a slave device. This<br />

combination of the two physical layers<br />

provides for ultimate functionality<br />

when connecting to a control system.<br />

This unique feature of the D77D-PNA<br />

provides for deterministic control<br />

using PROFIBUS along with the flexibility<br />

to monitor and configure I/O<br />

devices over Modbus. The Modbus<br />

connection is a read-only connection<br />

not allowing control of I/O devices<br />

ensuring a single point of control.<br />

To simplify the configuration of the<br />

D77D-PNA, a simple auto-configure<br />

button press sets the system up for<br />

default operation. This automatically<br />

configures the telegrams to the system<br />

devices.<br />

Application Description<br />

In a typical PROFIBUS Adapter application,<br />

the D77D-PNA connects directly<br />

to PROFIBUS, and resides in a system<br />

with IT. I/O and other communicating<br />

motor controls. The data from these<br />

IT. devices is assembled into input<br />

and output telegrams before being<br />

presented.<br />

Standards and Certifications<br />

Approvals<br />

Table 94. Approvals/Certifications<br />

Description<br />

Specification<br />

Electrical/EMC<br />

ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />

Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />

Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />

Surge (<strong>IEC</strong> 61000-4-5)<br />

± 1 kV line-to-ground, ± 2 kV line-to-line<br />

RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />

Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />

Other Approvals<br />

Ingress Protection Code<br />

IP20<br />

Radiated and Conducted Emissions EN 5011 Class A<br />

Agency Certifications<br />

UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />

Modbus Conformance Tested<br />

Technical Data and Specifications<br />

Table 95. Environmental Ratings<br />

Description Specification<br />

Transportation/Storage<br />

Temperature -58° – 176°F (-50° – 80°C)<br />

Humidity 5 – 95% non-condensing<br />

Operating<br />

Temperature -13° –149 °F (-25° – 65°C)<br />

Humidity 5 – 95% non-condensing<br />

Altitude<br />

Above 6,600 ft. (2,000m)<br />

consult factory<br />

Shock<br />

(<strong>IEC</strong> 68-2-27)<br />

Vibration<br />

(<strong>IEC</strong> 68-2-6)<br />

Pollution Degree 2<br />

15G any direction for<br />

11 mS<br />

5 – 150 Hz, 5G .7 mm<br />

maximum peak-to-peak<br />

Table 96. PROFIBUS Specifications<br />

Description Specification<br />

Connection DB9<br />

I/O Size<br />

244 Bytes Input<br />

176 Bytes Output<br />

Baud<br />

Up to 12 Megabit<br />

Addressing DIP Switch 1 – 255<br />

Channels 2 Independent<br />

Channels<br />

CHA Current 170 mA<br />

Draw<br />

CHB Current 10 mA<br />

Draw<br />

CA05001001E<br />

For more information visit: www.eaton.com


62<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

Communication Adapters (D77D Series) — PROFIBUS Adapter<br />

May 2007<br />

Dimensions<br />

3.5<br />

(90)<br />

1.8<br />

(45)<br />

2.7<br />

(68)<br />

Figure 79. D77D-PNA — Approximate Dimensions in Inches (mm)<br />

2<br />

(50.8)<br />

Module<br />

Module<br />

Module<br />

2 (50.8)<br />

Module<br />

Module<br />

2<br />

(50.8)<br />

Product Selection<br />

Table 97. PROFIBUS Adapter Product<br />

Selection<br />

Description<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

PROFIBUS Adapter D77D-PNA 580.<br />

2 (50.8)<br />

Figure 80. D77D-PNA Module Ventilation —<br />

Approximate Dimensions in Inches (mm)<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

For more information visit: www.eaton.com<br />

CA05001001E


May 2007<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

CH Studio Component Manager Software 45<br />

63<br />

CH Studio<br />

Product Description<br />

CH Studio Component Manager<br />

Software<br />

CH Studio from Eaton’s electrical business<br />

is an integrated software development<br />

environment that supports<br />

the configuration and monitoring of<br />

control products and systems. The<br />

application simplifies the monitoring<br />

and configuration of entire networks,<br />

as well as the enhanced features of<br />

individual IT. communicating devices<br />

within those networks.<br />

CH Studio takes advantage of the<br />

Windows graphical interface to<br />

present a suite of tools that is easy to<br />

learn and efficient to use, while meeting<br />

the requirements for developing<br />

complex network configurations.<br />

Configure Eaton’s Cutler-Hammer<br />

Control Devices<br />

Component Manager provides for the<br />

configuration and monitoring of the<br />

following Cutler-Hammer ® products:<br />

■ IT. Motor Control Center (MCC)<br />

■ IT. Electro-Mechanical Motor Starters<br />

connected by a Starter Network<br />

Adapter Product (SNAP) or Cover<br />

Control<br />

■ IT. S751/S752 Soft Starters connected<br />

by a SNAP, Cover Control or<br />

a Network Adapter<br />

■ IT. I/O modules<br />

■ IT. S811 Soft Starter connected by<br />

network Adapter<br />

■ IT. D77D-DNA DeviceNet network<br />

Adapter<br />

■ IT. D77D-EMA Modbus/TCP network<br />

Adapter<br />

■ IT. D77D-EIP EtherNet/IP network<br />

Adapter<br />

■ IT. D77D-PNA PROFIBUS network<br />

Adapter<br />

■ Cutler-Hammer legacy DeviceNet<br />

products<br />

Configure Other DeviceNet <strong>Products</strong><br />

CH Studio provides the capacity to<br />

configure and monitor all DeviceNet<br />

products that are supported by a published<br />

EDS file, regardless of vendor.<br />

The DeviceNet management package<br />

includes prepackaged support of over<br />

4000 different devices, and the capability<br />

to include new EDS files, as<br />

needed.<br />

Application Description<br />

The CH Studio Software runs on any<br />

personal computer hosting one of the<br />

following supported Windows operating<br />

systems:<br />

■ MS Windows XP<br />

■ MS Windows 2000<br />

A typical automation system is<br />

comprised of a programmable logic<br />

controller acting as a master, and<br />

numerous slave devices such as network<br />

adapters, motor starters, or I/O<br />

modules. The devices are networked<br />

via an industrial fieldbus such as<br />

DeviceNet or Modbus/TCP.<br />

A personal computer hosting CH<br />

Studio may be connected to an industrial<br />

network using a supported interface<br />

card or common Ethernet port<br />

(a variety of network protocols, such<br />

as Modbus/TCP, utilize Ethernet for a<br />

physical layer). CH Studio can then be<br />

used to configure and commission the<br />

automation products and network.<br />

Industry Standard Fieldbus (DeviceNet/EtherNet)<br />

USB/<br />

DeviceNet<br />

Adapter<br />

D77SX-A-X<br />

Network Adapter<br />

D77D-DNA<br />

(DeviceNet)<br />

D77D-EMA<br />

(Modbus/TCP)<br />

Network Adapter<br />

D77D-DNA<br />

(DeviceNet)<br />

D77D-EMA<br />

(Modbus/TCP)<br />

Starter<br />

Interface<br />

D77D-DSNAP<br />

IT. EM<br />

Starter<br />

IT. S811<br />

Soft Starter<br />

IT. EM<br />

Starter<br />

Screen Shot<br />

CH Studio components include<br />

Explorer, Property, Output, Toolbox,<br />

Message Editor, Property Pages, and<br />

Device Selector windows and dialog<br />

boxes.<br />

PC Hosting<br />

Component<br />

Manager<br />

Figure 81. Network Diagram<br />

Cover Control<br />

IT. MCC (Typical)<br />

CA05001001E<br />

For more information visit: www.eaton.com


64<br />

<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />

IT. Connect<br />

CH Studio Component Manager Software<br />

May 2007<br />

Features, Functions and<br />

Benefits<br />

Studio provides powerful features:<br />

■ Fast discovery of devices on<br />

DeviceNet, Modbus/TCP and<br />

Ethernet/IP networks.<br />

■ “Snapshot” storage of an entire networks<br />

worth of device parameters<br />

with just one mouse-click.<br />

■ Rapid configuration of IT. family<br />

products via “plug-in” support components<br />

that are regularly updated<br />

via the Internet.<br />

■ Online and offline operation with<br />

flexible synchronization options.<br />

■ Custom configuration dialogs for<br />

point and click ease of configuration,<br />

support for any DeviceNet<br />

product with or without EDS files.<br />

■ Extensive report generation to assist<br />

<strong>PLC</strong> or DCS programmers.<br />

■ OPC server for industry standard<br />

communications with third party<br />

products such as HMI, data<br />

acquisition and control applications.<br />

■ Built-in 4800+ device EDS file<br />

database.<br />

■ OPC server-to-control and monitor<br />

QCPort device over OPC.<br />

■ Tag export feature to import tag<br />

data to the controller.<br />

■ Live I/O to view actual status of the<br />

QCPort I/O when online.<br />

Technical Data and<br />

Specifications<br />

■ Processor: 230 MHz Pentium class<br />

minimum; 300+ MHz recommended.<br />

■ Memory (RAM): 64 MB Minimum<br />

(may limit performance); 128 MB+<br />

recommended.<br />

■ Hard Drive Space: 120 MB - CHStudio<br />

additional 70 meg for online<br />

documentation in .PDF format.<br />

■ Super VGA 800x600 or higher resolution<br />

video adapter and monitor.<br />

■ CDROM or DVD Drive (required for<br />

installation).<br />

■ Keyboard and Microsoft mouse or<br />

compatible pointing device.<br />

■ Industrial network adapter. Studio<br />

makes use of the Ethernet port that<br />

comes as standard equipment on<br />

most PCs for industrial protocols<br />

such as MODBUS/TCP. For<br />

DeviceNet networks a USB/<br />

DeviceNet converter is available, or<br />

you may use one of the popular SS<br />

Technologies Devicenet interfaces in<br />

the 5136 series (ISA, PCI, PCMCIA<br />

supported).<br />

USB DeviceNet Adapter<br />

The D77SX-A-X USB converter is a<br />

cost-effective interface for DeviceNet<br />

networks. Specifically designed for<br />

use with CH Studio, the USB converter<br />

provides a high performance<br />

DeviceNet interface with Plug and<br />

Play ease of installation. The D77SX-<br />

A-X comes in kit form including USB<br />

and 6-foot DeviceNet to mini cables.<br />

Drivers for the converter are built into<br />

CH Studio.<br />

Product Selection<br />

The following table lists the Catalog<br />

Numbers for available CH Studio<br />

software packages:<br />

Table 98. CH Studio Product Selection<br />

Description<br />

CH Studio Component<br />

Manager V2.1<br />

CH Studio Component<br />

Manager V2.1 w/USB<br />

interface<br />

USB/DeviceNet<br />

Interface (Alone)<br />

CH Studio Component<br />

Manager 2.1 and OPC<br />

Server<br />

CH Studio Component<br />

Manager 2.1 OPC<br />

Server<br />

Catalog<br />

Number<br />

Price<br />

U.S. $<br />

D77SC-X-D 1,040.<br />

D77SC-A-D 1,325.<br />

D77SX-A-X 555.<br />

D77SC-X-P 1,315.<br />

D77SC-A-P 1,575.<br />

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />

Eaton Corporation<br />

Electrical Group<br />

1000 Cherrington Parkway<br />

Moon Township, PA 15108<br />

United States<br />

877-ETN CARE (877-386-2273)<br />

Eaton.com<br />

© 2007 Eaton Corporation<br />

All Rights Reserved<br />

Printed in USA<br />

Publication No. CA05001001E/CPG<br />

May 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!