EATON PLC, I/O & Communications Products ... - IEC Supply, LLC
EATON PLC, I/O & Communications Products ... - IEC Supply, LLC
EATON PLC, I/O & Communications Products ... - IEC Supply, LLC
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
1<br />
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong><br />
<strong>Products</strong><br />
Contents<br />
Description<br />
Page<br />
ELC Programmable Logic Controllers<br />
Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
ELC Controllers / Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />
ELC Graphics Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />
ELC Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
EZ Intelligent Relays<br />
Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />
EZ 500/700/800/EZD Intelligent Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
EZD Controller I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />
EZ/EZD Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />
EZ/EZD Communication Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />
IT. Connect<br />
Remote I/O Modules (D77A Series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<br />
Starter Network Adapters (SNAP) (D77B Series) . . . . . . . . . . . . . . . . . . . 51<br />
DeviceNet SNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />
QCPort SNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53<br />
Communication Adapters (D77D Series) . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
DeviceNet Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />
Modbus Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br />
EtherNet/IP Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />
PROFIBUS Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />
CH Studio Component Manager Software . . . . . . . . . . . . . . . . . . . . . . . . 63<br />
Note: Supplement to Publication No. CA08102001E — Tabs 49 and 50.<br />
ELC and IT. <strong>Products</strong><br />
CA05001001E<br />
For more information visit: www.eaton.com
2<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers / Modules<br />
May 2007<br />
ELC Product Family Overview<br />
ELC Modules<br />
The Eaton Logic Controller (ELC) is our<br />
latest offering into the <strong>PLC</strong> (Programmable<br />
Logic Controller) marketplace.<br />
With the latest technology, this<br />
reduced sized ELC with its abundant<br />
module selection will provide a “Just<br />
Right” concept of providing only what<br />
you want for the price you need.<br />
■ Size – Providing large <strong>PLC</strong> features/<br />
functions in a small 1" package. ELC is<br />
1/3 the size of a D50, offering identical<br />
and even a larger feature set than the<br />
D50. ELC can provide 46 I/O in the<br />
space that a D50 could provide 14 I/O.<br />
■ Flexibility – ELC controllers can<br />
handle I/O counts from 10 I/O to 256<br />
I/O using the same controller. ELC<br />
eliminates the process of counting<br />
I/O and deciding which controller to<br />
use, ELC is the only one needed.<br />
ELC modules come in many flavors<br />
of I/O from modules containing<br />
4 in / 4 out to modules containing<br />
8 in / 8 out. ELC is not a rack based<br />
system — it simply mounts to a DIN<br />
rail. Add modules by simply snapping<br />
them into the mating connectors<br />
and closing the attached locks.<br />
■ Large <strong>PLC</strong> Features – ELC has the<br />
feature set of larger <strong>PLC</strong>s, from its<br />
multiple communications ports,<br />
remote I/O ability, data storage, high<br />
speed counter, high speed pulse<br />
outputs, interrupts, timer resolution<br />
to 1 ms, PID, plus much more.<br />
■ Software – ELCSoft, the software,<br />
configures the entire line of ELC<br />
controllers. Priced less than $200,<br />
it programs in standard ladder logic<br />
and sequential function chart programming.<br />
It will aid in knowing<br />
what registers are in use and what<br />
modules are attached to the ELC. It<br />
monitors the runtime application,<br />
allows forcing (except basic), and<br />
entering values. Software wizards<br />
aid programming of remote I/O,<br />
standard communications and PIDs.<br />
■ Power of One – ELC communicates<br />
easily to MVX drives, eliminating<br />
the need to operate drives by analog<br />
voltage/current or digital I/O. ELC<br />
can access all of the parameters in<br />
the MVX by serial communications,<br />
saving OEM money. ELC communicates<br />
to IT. I/O through the Modbus<br />
TCP gateway. This allows ELC to<br />
control the IT. I/O if local control is<br />
desired. This will also allow IT. I/O to<br />
be used in communicating MCC<br />
applications where the ELC can be<br />
either a DeviceNet, Profibus, or<br />
ModbusTCP communicating MCC.<br />
ELC communicates to PowerNet<br />
Modbus products, allowing ELC<br />
connectivity to Switchgear and<br />
PowerNet applications.<br />
■ Price – Following the “Just Right”<br />
concept, ELC is priced correctly to<br />
please customers.<br />
ELC Controllers/Modules<br />
Product Description<br />
ELC Controllers<br />
The ELC family offers four styles of<br />
controllers. These controllers offer<br />
combinations of the following features:<br />
■ High speed pulse capture and high<br />
speed pulse output on all controllers<br />
■ Interrupts<br />
■ Large module selection AC/DC in,<br />
relay/transistor out<br />
■ Large analog selection of analog in,<br />
out, combined, thermocouple, RTD<br />
Platinum<br />
■ Over 200 instructions to choose<br />
from: Floating point math, communications,<br />
hex, decimal, octal, BCD,<br />
ASCII conversion, 1, 4, 8, 16, 32, bit<br />
manipulations, logical, block move,<br />
block compare, retentive data storage,<br />
time base from clock/calendar<br />
■ 2 Modbus (ASCII or RTU) serial<br />
ports: 1 slave only, 1 master/slave<br />
■ Network communications on<br />
Modbus TCP, DeviceNet and<br />
Profibus<br />
■ ELC controller can be wired for<br />
remote I/O communications (except<br />
the PB model).<br />
ELC Modules<br />
ELC Expansion Modules<br />
ELC expansion modules provide the<br />
correct amount of I/O for application<br />
solutions. Choose 4, 8, or 16 I/O. Any<br />
number of expansion modules can be<br />
added to the ELC processor to create<br />
256 I/O (128 Inputs and 128 Outputs<br />
maximum).<br />
ELC Specialty Modules<br />
In addition the to expansion I/O, specialty<br />
modules like Analog In, Analog<br />
Out, Platinum Temperature, Thermocouple,<br />
DeviceNet, PROFIBUS DP and<br />
Switch Module, etc. can be added. Use<br />
the ELC-485APTR to easily connect to<br />
the RS-485 port of MVX drive, ELC controllers<br />
and other devices.<br />
Catalog Number Selection<br />
Table 1. ELC Controllers/Modules Catalog Numbering System<br />
E L C - A N 02 N A N N<br />
Module Type<br />
Digital Outputs<br />
AN = Analog<br />
EX = Digital Expansion<br />
PA = Processor w/clock & analog<br />
PB = Processor w/o clock<br />
PC = Processor w/clock<br />
PH = Processor, high speed<br />
PT = PT100<br />
TC = Thermocouple<br />
Analog Inputs<br />
A =AC<br />
N = None<br />
I/O Count<br />
Digital Inputs<br />
A =AC<br />
D =DC<br />
N = None<br />
Analog Outputs<br />
A = Analog<br />
N = None<br />
I = High Currency Relay<br />
N = None<br />
R = Relay<br />
T = Transistor<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers / Modules<br />
3<br />
Features<br />
ELC Controllers<br />
POWER<br />
POWER<br />
POWER<br />
POWER<br />
RUN<br />
ERROR<br />
BAT.LOW<br />
RUN<br />
ERROR<br />
BAT.LOW<br />
RUN<br />
ERROR<br />
BAT.LOW<br />
RUN<br />
ERROR<br />
BAT.LOW<br />
RUN<br />
RUN<br />
RUN<br />
RUN<br />
STOP<br />
STOP<br />
STOP<br />
STOP<br />
0<br />
0<br />
1<br />
1<br />
ELC-PB14 Series ELC-PC12 Series ELC-PA10 Series ELC-PH12NNDT<br />
Figure 1. ELC Controllers<br />
Table 2. ELC Controller Features<br />
Items ELC-PB14 Series ELC-PC12 Series ELC-PA10 Series ELC-PH12NNDT<br />
Maximum I/O<br />
I/O Type 14<br />
(8 In / 6 Out) – Digital<br />
256 (128 In / 128 Out) Any number of modules<br />
12<br />
(8 In / 4 Out – Digital)<br />
10<br />
(4 In / 2 Out Digital,<br />
2 In / 2 Out Analog)<br />
Execution Speed<br />
Basic commands - 2µ seconds minimum<br />
Program Language<br />
Boolean + Ladder Logic + SFC<br />
Program Capacity 3792 Steps 7920 Steps<br />
Data Memory Capacity (bits) 1280 Bits 4096 Bits<br />
Data Memory Capacity (words) 744 Words 5000 Words<br />
Index Registers 2 Words 8 Words<br />
File Memory Capacity — 1600 Words<br />
Commands 32 Basic / 107 Advanced 32 Basic / 168 Advanced<br />
Floating Point Yes Yes<br />
SFC Commands 128 Steps 1024 Steps<br />
Timers 128 (1 – 100 ms) 256 (1 – 100 ms)<br />
Counters 128<br />
(16 Bit / 32 Bit / Up/Down)<br />
250 (16 Bit / 32 Bit / Up/Down)<br />
High Speed Counters 1<br />
(14 modes) 10K Max<br />
1 (14 modes)<br />
20 kHz for PA/PC<br />
100 kHz for PH<br />
12<br />
(8 In / 4 Out – Digital)<br />
Pulse Output 2 channels 10 kHz Max 2 channels, 40 kHz Max for PC/PA, 100 kHz for PH<br />
Master Control Loop<br />
8 Loops<br />
Subroutines 64 Subroutines 256 Subroutines<br />
Interrupts 6 15 (External / Time base / HS CNTR / Comm.)<br />
Real-time Clock/Calendar — Built-in<br />
Specialty Expansions Modules<br />
8 (Analog In / Analog Out / TC / PT) Modules do not count in total I/O<br />
Serial Ports<br />
2 (1 – RS-232, 1 – RS-485)<br />
Special Features — 2 Potentiometers 2 7-Segment Displays 2 Potentiometers<br />
CA05001001E<br />
For more information visit: www.eaton.com
4<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers / Modules<br />
May 2007<br />
ELC Expansion Modules<br />
Style 1 Style 2<br />
Figure 2. ELC Expansion Modules<br />
Table 3. ELC Expansion Module Features<br />
Model Style Inputs Outputs<br />
Points Type Points Type<br />
ELC-EX08NNAN — AC IN 1 8 120V AC 0 —<br />
ELC-EX08NNDN — DC IN 1 8 DC Sink or Source 0 —<br />
ELC-EX08NNNR — Relay OUT 1 0 — 8 Relay<br />
ELC-EX08NNNT — Transistor OUT 1 0 — 8 Transistor<br />
ELC-EX06NNNI — High Current Relay OUT 2 0 — 6 Relay (6 Amps)<br />
ELC-EX08NNDR — IN/OUT Combo 2 4 DC Sink or Source 4 Relay<br />
ELC-EX16NNDR — IN/OUT Combo 2 8 DC Sink or Source 8<br />
ELC-EX08NNDT — IN/OUT Combo 2 4 DC Sink or Source 4 Transistor<br />
ELC-EX16NNDT — IN/OUT Combo 2 8 DC Sink or Source 8<br />
For more information visit: www.eaton.com<br />
CA05001001E
3<br />
3<br />
2<br />
2 2<br />
7<br />
8<br />
7<br />
8<br />
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers / Modules<br />
5<br />
ELC Specialty Modules<br />
ON<br />
IN<br />
POWER<br />
POWER<br />
ELC-EX08NNSN<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
X0<br />
X1<br />
X2<br />
X3<br />
X4<br />
X5<br />
X6<br />
X7<br />
ELC-COPBDP<br />
NET<br />
NODE ADDRESS<br />
x16 1<br />
x16 0<br />
ELC-CODNET<br />
MS<br />
NS<br />
4<br />
1<br />
4<br />
1<br />
5<br />
0<br />
5<br />
0<br />
6<br />
9<br />
6<br />
9<br />
1 2 3 4<br />
DIP ON<br />
1<br />
x10<br />
0<br />
x10<br />
DR1<br />
DR0<br />
IN1<br />
IN0<br />
ELC-EX485APTR<br />
COM2 COM1<br />
7<br />
Style 1 Style 2<br />
Figure 3. ELC Specialty Expansion Modules<br />
Style 3 Style 4 Style 5<br />
Style 6 — with<br />
ELC-ACCOVER<br />
Table 4. ELC Expansion Module Features<br />
Model Power Style Inputs Outputs<br />
Points Type Points Type<br />
ELC-AN02NANN — Analog OUT 24V DC 1 0 -20 mA~20 mA 2 (12 bits) 0~20 mA, 4~20 mA<br />
ELC-AN04NANN — Analog OUT 2 0 -10V ~ +10V 4 (12 bits) 0V ~ +10V, 2V ~ +10V<br />
ELC-AN06AANN — Analog Combo 2 4 ±10V, ±20 mA 2 (12 bits) 0~20 mA, 0 ~ +10V<br />
ELC-AN04ANNN — Analog IN 2 4 (V = 14 bits, I = 11 bits ±10V, ±20 mA 0<br />
ELC-PT04ANNN — PT100 2 4 (V = 14 bits, I = 13 bits) PT100 0<br />
ELC-TC04ANNN — Thermocouple 2 4 Thermocouple 0<br />
ELC-EX08NNSN — Switch Input 24V DC 3 8 Switch 0<br />
ELC-COPBDP — PROFIBUS DP 24V DC 4 32 Digital 32 Digital<br />
ELC-CODNET — DeviceNet 24V DC 5 32 Digital 32 Digital<br />
ELC-485APTR — RS-485 Easy Connect N/A 6 0 — 0 —<br />
CA05001001E<br />
For more information visit: www.eaton.com
6<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers / Modules<br />
May 2007<br />
Product Selection<br />
Table 5. ELC Controllers (PB, PC, PA, PH)<br />
Description Inputs Outputs Max. Current<br />
AC DC Analog Relay Transistor Analog<br />
Consumption<br />
(at 24V DC)<br />
14 I/O PB Series<br />
14 I/O PB Series<br />
12 I/O PC Series<br />
12 I/O PC Series<br />
12 I/O PC Series<br />
10 I/O PA Series<br />
10 I/O PA Series<br />
8<br />
8<br />
8<br />
8<br />
8<br />
6<br />
4<br />
4<br />
6<br />
150 mA<br />
150 mA<br />
250 mA<br />
250 mA<br />
250 mA<br />
Catalog<br />
Number<br />
ELC-PB14NNDR<br />
ELC-PB14NNDT<br />
ELC-PC12NNAR<br />
ELC-PC12NNDR<br />
ELC-PC12NNDT<br />
4<br />
4 2<br />
2<br />
2<br />
210 mA<br />
ELC-PA10AADR<br />
341.00<br />
4 2<br />
2<br />
2<br />
210 mA<br />
ELC-PA10AADT<br />
341.00<br />
12 I/O PH Series 8 4 170 mA ELC-PH12NNDT 198.00<br />
Price<br />
U.S. $<br />
149.00<br />
149.00<br />
198.00<br />
198.00<br />
198.00<br />
Table 6. Digital I/O Expansion Modules<br />
Description Inputs Outputs Max. Current<br />
AC DC Relay Transistor<br />
Consumption<br />
(at 24V DC)<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
6 I/O Expansion (6 Amp Outputs) 6 70 mA ELC-EX06NNNI 105.00<br />
8 I/O Expansion — AC IN<br />
8<br />
50 mA<br />
ELC-EX08NNAN<br />
71.50<br />
8 I/O Expansion — DC IN<br />
8<br />
50 mA<br />
ELC-EX08NNDN<br />
60.50<br />
8 I/O Expansion — Relay OUT<br />
8<br />
70 mA<br />
ELC-EX08NNNR<br />
93.50<br />
8 I/O Expansion — Transistor OUT<br />
8<br />
70 mA<br />
ELC-EX08NNNT<br />
93.50<br />
8 I/O Expansion — IN/OUT Combo<br />
4 4<br />
70 mA<br />
ELC-EX08NNDR<br />
93.50<br />
8 I/O Expansion — IN/OUT Combo<br />
4<br />
4<br />
70 mA<br />
ELC-EX08NNDT<br />
93.50<br />
16 I/O Expansion — IN/OUT Combo<br />
8 8<br />
90 mA<br />
ELC-EX16NNDR<br />
105.00<br />
16 I/O Expansion — IN/OUT Combo<br />
8<br />
8<br />
90 mA<br />
ELC-EX16NNDT<br />
105.00<br />
8 I/O Expansion — Switch Input 8 20 mA ELC-EX08NNSN 71.50<br />
Table 7. Analog I/O Modules<br />
Description<br />
Analog<br />
In<br />
Analog<br />
Out<br />
Max. Current<br />
Consumption<br />
(at 24V DC)<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
4 I/O Analog In 4 90 mA ELC-AN04ANNN 193.00<br />
2 I/O Analog Out 2 125 mA ELC-AN02NANN 182.00<br />
4 I/O Analog Out 4 170 mA ELC-AN04NANN 253.00<br />
6 I/O Analog In/Out 4 2 90 mA ELC-AN06AANN 264.00<br />
4 I/O Thermocouple J, K, R, S, T 4 90 mA ELC-TC04ANNN 275.00<br />
4 I/O Platinum RTD, PT100 4 90 mA ELC-PT04ANNN 242.00<br />
Table 8. Accessory Modules<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
Profibus DP Module ELC-COPBDP 358.00<br />
DeviceNet Module ELC-CODNET 253.00<br />
RS-485 Easy Connect Adapter, DB9, ELC-485APTR 60.50<br />
RJ-12, 2-Pin Connections to RS-485<br />
Motion Control, 1 Axis Module<br />
(Up to 8 Modules per Controller)<br />
ELC-MCO1 336.00<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers / Modules<br />
7<br />
Standards and Certifications<br />
Table 9. Approvals/Certifications<br />
Description<br />
Electrical/EMC<br />
ESD Immunity<br />
EFT Immunity<br />
Damped-Oscillatory Wave<br />
RS Immunity<br />
Other Approvals<br />
Agency Certifications<br />
Technical Data and Specifications<br />
Table 10. Environmental Ratings<br />
Description<br />
Transportation & Storage<br />
Specification<br />
Table 11. DC Input Point Electrical Specifications<br />
8 kV air discharge<br />
Power Line: 2 kV; Digital I/O: 1 kV; Analog & Communication I/O: 250V<br />
Power Line: 1 kV; Digital I/O: 1 kV<br />
26 MHz – 1 GHz, 10 V/m<br />
UL 508, cUL, CE; Class 1 Div 2 Group A, B, C, D<br />
Specification<br />
Temperature<br />
-13° – 158°F (-25° – 70°C)<br />
Humidity 5 – 95%<br />
Operating<br />
Temperature<br />
32° – 131°F (0° – 55°C)<br />
Humidity 50 – 95%<br />
Power <strong>Supply</strong> Voltage ELC: 24V DC (-15% – 20%) (With DC input reverse polarity protection),<br />
Expansion Unit: supplied by the ELC<br />
Power Consumption 3 – 6W<br />
Insulation Resistance > 5 MΩ at 500V DC (Between all inputs/outputs and earth)<br />
Grounding<br />
The diameter of grounding wire cannot be smaller than the wire<br />
diameter of terminals L and N (All ELC units should be grounded<br />
directly to the ground pole).<br />
Vibration / Shock Resistance Standard: <strong>IEC</strong>1131-2, <strong>IEC</strong> 68-2-6 (TEST Fc) / <strong>IEC</strong>1131-2 & <strong>IEC</strong> 68-2-27<br />
(TEST Ea)<br />
Weight (approx.)<br />
0.348 Lbs (0.158 kg)<br />
Description<br />
Specification<br />
Input Type<br />
Input Current<br />
Active Level<br />
Response Time<br />
DC (SINK or SOURCE)<br />
24V DC 5 mA<br />
OFF ➔ ON, above 16V DC<br />
ON ➔ OFF, below 14.4V DC<br />
About 10 mS (An adjustment range of 0 – 10,000 mS could be selected<br />
through D1020 and D1021)<br />
Table 12. Output Point Electrical Specifications<br />
Output Type Relay – R Transistor – T<br />
Current Specification 1.5A/1 point (5A/COM) 0.3A/1 point @ 40°C; When the output of Y0 and Y1 is high-speed pulse,<br />
Y0 and Y1 = 30 mA<br />
Voltage Specification Below 250V AC, 30V DC 30V DC<br />
Maximum Loading 75 VA (Inductive) 9W/1 point When the output of Y0 and Y1 is high-speed pulse, Y0 and<br />
90W (Resistive)<br />
Y1 = 0.9W (Y0 = 32 kHz, Y1 = 10kHz), Y0 can be 50 kHz using<br />
D registers.<br />
Response Time Adjustable 0 – 15 ms, default is 10 ms OFF ➔ ON 20 µs<br />
ON ➔ OFF 30 µs<br />
Y0 and Y1 are specified points for high-speed pulse<br />
CA05001001E<br />
For more information visit: www.eaton.com
ANB<br />
AND<br />
SPACE<br />
CLEAR<br />
SHIFT<br />
TEST<br />
STOP<br />
8<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers/Modules<br />
May 2007<br />
ELC Accessories<br />
ELC-GPXFERMOD<br />
Transfer programs to or from ELC-GPxx<br />
units. These devices can be write protected<br />
to maintain program integrity.<br />
ELC-HHP<br />
ELC-HHP is an easy-to-use, hand-held<br />
programming tool for ELC controllers<br />
when a PC is not available. With ELC-<br />
HHP, applications can be programmed<br />
directly with the attached keypad. Or<br />
uploaded from an ELC, saved, and<br />
transferred to a different ELC. Or<br />
downloaded from a PC and transferred<br />
to other ELCs. No need for outlets<br />
when using the ELC-HHP since it<br />
draws its power from either the ELC<br />
or the PC through the attached cable.<br />
Monitor applications when a PC is not<br />
available.<br />
LD<br />
LDI<br />
X<br />
OUT<br />
T<br />
ANI<br />
Y<br />
SET<br />
C<br />
OR<br />
RST<br />
8<br />
ORI<br />
M<br />
TMR<br />
D<br />
API<br />
NOP<br />
4<br />
ORB<br />
K<br />
CNT<br />
9<br />
S<br />
0<br />
MC<br />
H P/I<br />
E<br />
RUN<br />
MPS<br />
5<br />
END<br />
MCR<br />
A<br />
1<br />
STL<br />
F<br />
STEP<br />
MRD<br />
6<br />
MAIN<br />
RET<br />
B<br />
2<br />
EDIT<br />
MPP<br />
3<br />
7<br />
MON<br />
INS<br />
DEL<br />
Figure 4. ELC-HHP with Cables for ELC and PC Connections<br />
ELC Power Supplies<br />
All ELC modules operate from 24V DC.<br />
These power supplies provide a convenient<br />
way to provide robust DC voltage.<br />
L<br />
N<br />
L<br />
N<br />
24V<br />
0V<br />
24V<br />
0V<br />
POWER<br />
ELC-PS01<br />
POWER<br />
ELC-PS02<br />
Figure 5. ELC Power Supplies<br />
Table 13. ELC Power <strong>Supply</strong> Specifications<br />
Item ELC-PS01 ELC-PS02<br />
Dimensions WxHxD in Inches (mm) 1.44 x 3.54 x 2.36 (36.5 x 90 x 60) 2.17 x 3.54 x 2.36 (55 x 90 x 60)<br />
Input Power<br />
100 – 240V AC 50/60 Hz<br />
Output Volts<br />
24V DC<br />
Output Current (A) 1A 2A<br />
Watts 24 48<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers/Modules<br />
9<br />
ELC-CBPCELC3<br />
Use this cable to download, upload,<br />
monitor ELC controllers. Or use this<br />
same cable to connect any ELC-GPxx<br />
to an ELC controller. This cable is 3<br />
meters long.<br />
PC/HMI COM Port<br />
9 PIN D-SUB Female<br />
<strong>PLC</strong> COM1 Port<br />
8 PIN MINI DIN<br />
Rx 2 5 Tx<br />
Tx 3 4 Rx<br />
2<br />
1<br />
1<br />
4<br />
GND 5 8 GND<br />
7<br />
1,2 5V<br />
8<br />
5<br />
8<br />
4<br />
7<br />
3<br />
6<br />
6<br />
Figure 6. ELC-CBPCELC3 Cable<br />
ELC-CBPCGP3<br />
Use this cable to download or upload<br />
applications between a PC and the<br />
ELC-GPxx graphics panels. This cable<br />
can also be used to transfer a program<br />
from an ELC-GPxx to another ELC-<br />
GPxx. This cable is 3 meters long.<br />
■ The Pin definition of 9 PIN D-SUB<br />
RS-232:<br />
ELC-GP04 COM Port<br />
RS-232 9 PIN D-SUB Male<br />
3<br />
2<br />
5<br />
Tx<br />
Rx<br />
GND<br />
ON PC (RS-232)<br />
ON ELC-GP02/04<br />
9<br />
5<br />
1<br />
6<br />
6<br />
1<br />
5<br />
9<br />
9 PIN D-SUB<br />
9 PIN D-SUB<br />
PC COM Port<br />
9 PIN D-SUB Female<br />
GP02/04 COM Port<br />
9 PIN D-SUB Female<br />
Rx 2 3 Tx<br />
Tx 3 2 Rx<br />
GND 5 5 GND<br />
Figure 7. PC or GPO2/04<br />
CA05001001E<br />
For more information visit: www.eaton.com
10<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers/Modules<br />
May 2007<br />
Table 14. ELC Accessories<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
24 Watt, 1 Amp Power <strong>Supply</strong> ELC-PS01 49.50<br />
48 Watt, 2 Amp Power <strong>Supply</strong> ELC-PS02 71.50<br />
Hand-Held Programmer (Includes ELC-CBHHELC15) ELC-HHP 286.00<br />
Cable to Connect a PC or a GP unit to ELC, 3 meters (DB9 pin ELC-CBPCELC3 34.25<br />
female to 8 pin DIN)<br />
Cable to Connect a PC to a GP unit. 3 meters (DB9 pin female ELC-CBPCGP3 34.25<br />
to DB9 pin female)<br />
Program transfer module for GP units ELC-GPXFERMOD 71.50<br />
Program transfer module for ELC controllers ELC-ACPGMXFR 105.00<br />
Plate mount for specialty modules, qty. 10 ELC-ACCOVER 82.50<br />
ELC Starter Kit (Includes ELC-PA10AADT, ELC-PS01, ELC-GP04,<br />
ELC-CBPCELC3, ELC-CBPCGP3, ELCSoft, ELCSoft GP)<br />
ELCSTARTKIT1 605.00<br />
Dimensions<br />
.12<br />
(3.0)<br />
POWER<br />
RUN<br />
ERROR<br />
BAT.LOW<br />
1.47<br />
(37.4)<br />
2.36<br />
(60.0)<br />
RUN<br />
3.54<br />
(90.0)<br />
STOP<br />
EXTENSION<br />
PORT<br />
.12<br />
(3.0)<br />
Figure 8. ELC-PA10, ELC-PC12 and ELC-PH12 Controllers — Approximate Dimensions in Inches (mm)<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers/Modules<br />
11<br />
.12<br />
(3.0)<br />
0.99<br />
(25.2)<br />
2.36<br />
(60.0)<br />
.12<br />
(3)<br />
3.54<br />
(90.0)<br />
EXTENSION<br />
PORT<br />
3.94<br />
(100)<br />
3.54<br />
(90)<br />
4.20<br />
(106.8)<br />
.12<br />
(3.0)<br />
.27<br />
(6.8)<br />
.12<br />
(3)<br />
2.51 (63.4)<br />
.28<br />
(7)<br />
Figure 11. Plate Mount for Specialty Modules<br />
Figure 9. ELC-PB14 Controllers — Approximate Dimensions in<br />
Inches (mm)<br />
.12<br />
(3.0)<br />
0.99<br />
(25.2)<br />
2.36<br />
(60.0)<br />
3.54<br />
(90.0)<br />
EXTENSION<br />
PORT<br />
.12<br />
(3.0)<br />
Figure 10. ELC Specialty Module — Approximate Dimensions in<br />
Inches (mm)<br />
CA05001001E<br />
For more information visit: www.eaton.com
12<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers/Modules<br />
May 2007<br />
2.00 (50.9)<br />
.78 (19.8)<br />
.39 (10.0)<br />
Figure 12. ELC-GPXFERMOD — Approximate Dimensions in Inches (mm)<br />
3.54<br />
(90.0)<br />
1.14<br />
(29.0)<br />
2.64<br />
(67.0)<br />
M3 p0.5<br />
4 Places<br />
7.09<br />
(180.0)<br />
3.60<br />
(91.5)<br />
1.81<br />
(46.0)<br />
1.73<br />
(44.0)<br />
Figure 13. ELC-HHP — Approximate Dimensions in Inches (mm)<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Controllers/Modules<br />
13<br />
1.44<br />
(36.5)<br />
.52<br />
(13.3)<br />
2.36<br />
(60.0)<br />
3.54<br />
(90.0)<br />
.12<br />
(3.0)<br />
Figure 14. ELC-PS01 Power <strong>Supply</strong> — Approximate Dimensions in Inches (mm)<br />
.12<br />
(3.0)<br />
2.17<br />
(55.0)<br />
1.28<br />
(32.5)<br />
.52<br />
(13.3)<br />
2.36<br />
(60.0)<br />
3.94<br />
(100.0)<br />
3.54<br />
(90.0)<br />
.12<br />
(3.0)<br />
Figure 15. ELC-PS02 Power <strong>Supply</strong> — Approximate Dimensions in Inches (mm)<br />
CA05001001E<br />
For more information visit: www.eaton.com
14<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Graphics Panels<br />
May 2007<br />
ELC Graphics Panels<br />
Product Description<br />
ELC Graphics Panels are simple to program<br />
and easily connect to ELC products.<br />
ELC graphics panels make<br />
modifying an application quick and<br />
easy. ELC graphics panels also connect<br />
to Cutler-Hammer ® MVX drives, IQ<br />
MODBUS meters and many other<br />
devices. With over 30 objects that can<br />
be placed anywhere on the display,<br />
these tough panels also communicate<br />
to other major controllers. These<br />
graphics panels have two serial ports<br />
which can be used simultaneously to<br />
communicate. Transfer applications to<br />
or from these graphics panels using<br />
the handy transfer module. Ten programmable<br />
functions keys provide<br />
easy to change pages, input numeric<br />
values, enter alpha-numeric passwords,<br />
set, reset and more. Create alarms,<br />
password protect, import bitmaps, and<br />
use many different fonts.<br />
Protocols Supported<br />
■ Eaton D50/D32LT, D320<br />
■ Eaton ELC<br />
■ Eaton MVX ASCII<br />
■ Eaton MVX RTU<br />
■ MODBUS ASCII<br />
■ MODBUS RTU<br />
■ AB DF1<br />
■ Mitsubishi FX Series<br />
■ Mitsubishi FX2N Series<br />
■ Koyo K-Sequence<br />
■ LG 200S<br />
■ OMRON C-Series<br />
■ Siemens 57-200 Series<br />
■ ASCII Slave Mode<br />
■ And more...<br />
0<br />
50<br />
100<br />
Features<br />
No Alarms<br />
Tank Fill Level<br />
ELC-GP02<br />
Table 15. ELC Graphics Panel Features<br />
Item ELC-GP02 ELC-GP04<br />
Display Screen<br />
Screen<br />
STN-LCD<br />
Color<br />
Monochromatic<br />
Back-light<br />
The back-light automatic turn off time is 1 – 99 minutes<br />
(0 = do not to turn off)<br />
(back-light life is 50 thousand hours at 25°C)<br />
Resolution 160X32 pixels 128X64 pixels<br />
Display Range 72 mm (W) X 22 mm (H) 67mm (W) X 32mm (H);<br />
3.00" (diagonal preferred)<br />
Contrast Adjustment 15-step contrast adjustment 10-step contrast adjustment<br />
Language Font<br />
ASCII: characters (including European Fonts)<br />
Taiwan: (BIG 5 code) traditional Chinese character font<br />
China: (GB2324-80 code) simplified Chinese character font<br />
Font Size (ASCII) 5 X 8, 8 X 8, 8 X 12, 8 X 16<br />
ALARM Indication LED<br />
1. Power on indication (Flash three times)<br />
2. Flash for communication error or other alarm<br />
3. Special Indication by user programming<br />
RS-232 LED (Yellow)<br />
Flashes when communicating<br />
RS-485 LED (Green)<br />
Flashes when communicating<br />
Program Memory<br />
Program Memory<br />
256KB flash memory<br />
External Interface<br />
Serial Communication Port<br />
RS-232 (COM1)<br />
9 PIN D-SUB male<br />
Extension Communication port<br />
RS-485 (COM2)<br />
5-Pin Removal Terminal<br />
(RS-485 or RS-422)<br />
Extension Slot<br />
Power<br />
RUN<br />
ELC-GP04<br />
RUN<br />
F3<br />
F4<br />
STOP<br />
Data length: 7 or 8 bits<br />
Stop bits: 1 or 2 bits<br />
Parity: None/Odd/Even<br />
Baud Rate: 4800 bps – 115200 bps<br />
Data length: 7 or 8 bits<br />
Stop bits: 1 or 2 bits<br />
Parity: None/Odd/Even<br />
Baud Rate: 4800 bps – 115200 bps<br />
The slot for program copy card<br />
24V DC input<br />
Product Selection<br />
Table 16. Graphics Panels<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
160 x 32 pixels, 10 Function Keys, Monochrome ELC-GP02 209.<br />
128 x 64 pixels, 10 Function Keys, Monochrome ELC-GP04 314.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Graphics Panels<br />
15<br />
Standards and Certifications<br />
Table 17. Approvals/Certifications<br />
Description<br />
Electrical/EMC<br />
Electrostatic Discharge Immunity<br />
Radiated Immunity<br />
Electrical Fast Transient<br />
Radiated Emission<br />
Other Approvals<br />
Waterproof Class of Front Panel<br />
Agency Certifications<br />
Specifications<br />
EN61000-4-2/1995<br />
EN61000-4-3/1995<br />
EN61000-4-4/1995<br />
CISPR22, Class A<br />
UL Type 4X Outdoor Rated<br />
UL 508, cUL (CSA C22.2 No. 14); CE (Low Voltage Directive);<br />
Class 1 Div 2 Groups A, B, C, D<br />
Technical Data and Specifications<br />
Table 18. Environmental Ratings/Specifications<br />
Description<br />
Transportation & Storage<br />
Temperature<br />
Operating<br />
Temperature<br />
Humidity<br />
Communication Interface<br />
Vibration<br />
Impact<br />
Weight<br />
Cooling Method<br />
Specification<br />
-4° – 140°F (-20° – 60°C)<br />
32° – 122°F (0° – 50°C)<br />
20 – 90% RH (non-condensing)<br />
COM1: RS-232; COM2: RS-485/RS-422<br />
0.5 mm displacement, 10 – 55 Hz, X, Y, Z three directions and<br />
two hours for each direction<br />
10G, 11 mS, from X, Y, Z three directions and three times for<br />
each direction<br />
0.53 Lbs. (0.24 kg)<br />
Natural Air Cooling<br />
CA05001001E<br />
For more information visit: www.eaton.com
16<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Graphics Panels<br />
May 2007<br />
Dimensions<br />
ALARM<br />
RS-232<br />
RS-485<br />
Up<br />
Pg Up<br />
3.82<br />
(97.0)<br />
Left<br />
Right<br />
3.35<br />
(85.0)<br />
Esc<br />
Pg Dn<br />
Down<br />
Shift<br />
F0<br />
F5<br />
F1<br />
F6<br />
F2<br />
F7<br />
F3<br />
F8<br />
F4<br />
F9<br />
Enter<br />
5.79<br />
(147.0)<br />
1.20<br />
(30.5)<br />
.14<br />
(3.5)<br />
1.40<br />
(35.5)<br />
5.31<br />
(135.0)<br />
Cut-Out Dimensions<br />
3.35<br />
(85.0)<br />
5.31 ~ 5.37<br />
(135 ~ 136.5)<br />
Figure 16. ECL-GP04 — Approximate Dimensions in Inches (mm)<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Graphics Panels<br />
17<br />
ALARM<br />
RS-232<br />
RS-485<br />
3.82<br />
(97.0)<br />
3.35<br />
(85.0)<br />
Esc<br />
F5<br />
5<br />
F0<br />
0<br />
F6<br />
6<br />
F1<br />
1<br />
F7<br />
7<br />
F2<br />
2<br />
F3<br />
3<br />
F8 F9<br />
8 9<br />
F4<br />
4<br />
Enter<br />
Left<br />
Up<br />
Pg Up<br />
Pg Dn<br />
Down<br />
Right<br />
5.79<br />
(147.0)<br />
1.20<br />
(30.5)<br />
.14<br />
(3.5)<br />
1.40<br />
(35.5)<br />
5.31<br />
(135.0)<br />
Cut-Out Dimensions<br />
3.35<br />
(85.0)<br />
5.31 ~ 5.37<br />
(135 ~ 136.5)<br />
Figure 17. ECL-GP02 — Approximate Dimensions in Inches (mm)<br />
CA05001001E<br />
For more information visit: www.eaton.com
18<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
ELC Programmable Logic Controllers<br />
ELC Software<br />
May 2007<br />
ELCSoft Programming<br />
Software<br />
ELCSoft Programming Software<br />
configures all ELC controllers. With<br />
ELCSoft, applications can be created,<br />
edited, monitored, forced, etc. Move<br />
programs from one controller to a<br />
different one with ease.<br />
Requirements:<br />
■ Operating Systems – Windows 98,<br />
Windows ME, Windows 2000,<br />
Windows XP<br />
■ Hard Drive – At least 100M bytes<br />
■ RAM – At least 256M bytes<br />
ELCSoftGP Programming<br />
Software<br />
ELCSoftGP Programming Software<br />
configures all ELC graphics panels.<br />
With ELCSoftGP, applications can be<br />
created, edited, downloaded, uploaded,<br />
etc. Move programs from one controller<br />
to a different one with ease.<br />
Requirements:<br />
■ Operating Systems – Windows 98,<br />
Windows ME, Windows 2000, Windows<br />
XP<br />
■ Hard Drive – At least 100M bytes<br />
■ RAM – At least 256M bytes<br />
ELCSoft Ladder Diagram Mode<br />
ELCSoftGP Editing Environment<br />
Product Selection<br />
Table 19. Software<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
ELCSoft Editor<br />
Programming Software for ELC Controllers ELCSOFT 215.<br />
Programming Software for GP Units ELCSOFTGP 215.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
Product Family Overview<br />
19<br />
Contents<br />
Description<br />
Page<br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD<br />
Intelligent Relays . . . . . . . 20<br />
EZD Controller<br />
I/O Modules . . . . . . . . . . . 27<br />
EZ/EZD Expansion<br />
Modules . . . . . . . . . . . . . . 28<br />
EZ/EZD Communication<br />
Modules . . . . . . . . . . . . . . 30<br />
EZ Software . . . . . . . . . . . . 31<br />
EZ/EZD Power Supplies. . . 32<br />
EZ/EZD Accessories . . . . . . 33<br />
EZ Intelligent Relays Product Family<br />
Product Family Overview<br />
The EZ intelligent relays bring timers,<br />
relays, counters, special functions,<br />
inputs and outputs into one compact<br />
device that is easily configured. The EZ<br />
family of products provides exceptional<br />
levels of flexibility together with<br />
substantial savings in commissioning<br />
time and effort.<br />
The EZ intelligent relays are available<br />
in more than 32 different styles that<br />
support from 12 I/O up to 320 I/O<br />
points providing the ideal solution for<br />
lighting, energy management, industrial<br />
control, watering, pump control,<br />
HVAC and home automation.<br />
Once EZ products are installed, changes<br />
are easily accomplished through front<br />
panel programming, eliminating the<br />
need to change wiring and wiring diagrams<br />
increasing the savings realized.<br />
Other terms often used for intelligent<br />
relay are relay replacer, control relay<br />
and smart relay.<br />
Application Description<br />
Generally where multiple relays, timers<br />
and pushbuttons are used there is an<br />
opportunity to evaluate switching to<br />
the EZ Intelligent Relays. Applications<br />
span residential, commercial and<br />
industrial installations. Typical applications<br />
are:<br />
■ Car washes.<br />
■ Automatic door control.<br />
■ Commercial lighting.<br />
■ Residential lighting.<br />
■ Exterior lighting.<br />
■ Pump control, 12V DC automotive<br />
control.<br />
■ Greenhouse control.<br />
■ Crane control.<br />
■ Machinery.<br />
■ Paper/pulp.<br />
■ Elevator control.<br />
■ Livestock feed/gate control.<br />
■ Irrigation control.<br />
■ Cart chargers.<br />
■ Heating and air conditioning.<br />
CA05001001E<br />
For more information visit: www.eaton.com
20<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
May 2007<br />
EZ 500/700/800/EZD Intelligent<br />
Relays<br />
EZD Series — for controlling largescale<br />
applications with up to 320 input/<br />
output signals using powerful visualization<br />
functions. The EZD display can<br />
be linked to the EZ500/700/800 models<br />
to provide an enhanced operator interface.<br />
Panel mounted.<br />
The EZ-NET integrated network provides<br />
easy and inexpensive linking of<br />
up to eight EZ800/EZD devices over a<br />
distance of up to 1000 meters. The EZ<br />
and EZD devices can run their own<br />
program or be used as a distributed<br />
input/output module. Connect up to 8<br />
controllers each with 40 I/O via a signal<br />
expansion module to obtain 320 I/O.<br />
EZ 500/700/800/EZD Intelligent Relays<br />
Product Description<br />
Four families make up the EZ Intelligent<br />
Relay product line.<br />
EZ500 Series — for controlling small<br />
applications with up to 12 input/output<br />
signals. Models are available with and<br />
without displays. DIN rail mounted.<br />
EZ700 Series — for controlling<br />
medium-sized applications with up to<br />
40 input/output signals. DIN rail<br />
mounted.<br />
EZ800 Series — for controlling largescale<br />
applications with up to 320 input/<br />
output signals. Models are available<br />
with and without displays. DIN rail<br />
mounted. Use EZ-NET for applications<br />
beyond 40 I/O.<br />
Catalog Number Selection<br />
Table 20. EZ500/700/800 Module Definition Catalog Numbering System<br />
Module Type<br />
5xx = 500 Series<br />
7xx = 700 Series<br />
8xx = 800 Series<br />
Product Selection<br />
EZ 7xx AC T C X<br />
Digital Inputs<br />
AB = 24V AC<br />
AC = 110 – 240V DC<br />
DA = 12V DC<br />
DC = 24V DC<br />
Display<br />
Blank = Display<br />
X = No Display<br />
Clock<br />
C = Clock<br />
Blank = No Clock<br />
Digital Outputs<br />
R = Relay<br />
T = Transistor<br />
EZ500 with Display<br />
EZ500 without Display<br />
Table 21. EZ500 Intelligent Relays<br />
Description Inputs Outputs Catalog<br />
24V 110 – 240V 12V 24V ALG RY TRN<br />
Number<br />
AC AC DC DC<br />
Price<br />
U.S. $<br />
12 I/O, Clock, Display<br />
12 I/O, Clock, No Display<br />
12 I/O, No Clock, Display<br />
12 I/O, Clock, Display<br />
12 I/O, Clock, No Display<br />
12 I/O, Clock, Display<br />
12 I/O, Clock, No Display<br />
12 I/O, No Clock, Display<br />
12 I/O, Clock, Display<br />
12 I/O, Clock, No Display<br />
12 I/O, Clock, Display<br />
12 I/O, Clock, No Display<br />
8<br />
8<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
8<br />
8<br />
8<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
8<br />
8<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
8<br />
8<br />
8<br />
8<br />
8<br />
2<br />
2<br />
—<br />
—<br />
—<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
4<br />
4<br />
EZ512-AB-RC<br />
EZ512-AB-RCX<br />
EZ512-AC-R<br />
EZ512-AC-RC<br />
EZ512-AC-RCX<br />
EZ512-DA-RC<br />
EZ512-DA-RCX<br />
EZ512-DC-R<br />
EZ512-DC-RC<br />
EZ512-DC-RCX<br />
EZ512-DC-TC<br />
EZ512-DC-TCX<br />
155.<br />
119.<br />
144.<br />
155.<br />
119.<br />
155.<br />
119.<br />
144.<br />
155.<br />
119.<br />
139.<br />
119.<br />
Note: Analog inputs optional.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
21<br />
EZ700 with Display<br />
EZ700 without Display<br />
Table 22. EZ700 Intelligent Relays<br />
Description Inputs Outputs Catalog<br />
24V AC 110 – 240V 12V DC 24V DC Analog Relay Transistor<br />
Number<br />
AC<br />
Price<br />
U.S. $<br />
18 I/O, Clock, Display<br />
18 I/O, Clock, No Display<br />
18 I/O, Clock, Display<br />
18 I/O, Clock, No Display<br />
18 I/O, Clock, Display<br />
18 I/O, Clock, No Display<br />
18 I/O, Clock, Display<br />
18 I/O, Clock, No Display<br />
20 I/O, Clock, Display<br />
20 I/O, Clock, No Display<br />
12<br />
12<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
12<br />
12<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
12<br />
12<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
12<br />
12<br />
12<br />
12<br />
4<br />
4<br />
—<br />
—<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
6<br />
6<br />
6<br />
6<br />
6<br />
6<br />
6<br />
6<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
8<br />
8<br />
EZ719-AB-RC<br />
EZ719-AB-RCX<br />
EZ719-AC-RC<br />
EZ719-AC-RCX<br />
EZ719-DA-RC<br />
EZ719-DA-RCX<br />
EZ719-DC-RC<br />
EZ719-DC-RCX<br />
EZ721-DC-TC<br />
EZ721-DC-TCX<br />
218.<br />
187.<br />
218.<br />
187.<br />
218.<br />
187.<br />
218.<br />
187.<br />
218.<br />
187.<br />
Note: Analog inputs optional.<br />
EZ800 with Display<br />
EZ800 without Display<br />
Table 23. EZ800 Intelligent Relays<br />
Description Inputs Outputs Catalog<br />
110 – 240V 24V DC Analog Relay Transistor Analog<br />
Number<br />
AC<br />
Price<br />
U.S. $<br />
18 I/O, Clock, Display<br />
18 I/O, Clock, No Display<br />
18 I/O, Clock, Display<br />
18 I/O, Clock, No Display<br />
19 I/O, Clock, Display<br />
19 I/O, Clock, No Display<br />
20 I/O, Clock, Display<br />
20 I/O, Clock, No Display<br />
21 I/O, Clock, Display<br />
21 I/O, Clock, No Display<br />
12<br />
12<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
12<br />
—<br />
—<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
6<br />
6<br />
6<br />
6<br />
6<br />
6<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
—<br />
8<br />
8<br />
8<br />
8<br />
—<br />
—<br />
—<br />
—<br />
1<br />
1<br />
—<br />
—<br />
1<br />
1<br />
EZ819-AC-RC<br />
EZ819-AC-RCX<br />
EZ819-DC-RC<br />
EZ819-DC-RCX<br />
EZ820-DC-RC<br />
EZ820-DC-RCX<br />
EZ821-DC-TC<br />
EZ821-DC-TCX<br />
EZ822-DC-TC<br />
EZ822-DC-TCX<br />
345.<br />
301.<br />
345.<br />
301.<br />
385.<br />
342.<br />
345.<br />
301.<br />
385.<br />
342.<br />
Note: Analog inputs optional, analog outputs optional.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
CA05001001E<br />
For more information visit: www.eaton.com
22<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
May 2007<br />
+ + =<br />
EZD-80 EZD-CP8 EZD I/O EZD Assembly<br />
Table 24. EZD Displays (EZD-80) and EZD Controllers (EZD-CP8)<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
EZD, No Buttons EZD-80 116.<br />
EZD, Buttons EZD-80-B 126.<br />
EZD CPU with 24V DC, Power <strong>Supply</strong>, Clock EZD-CP8-ME 283.<br />
EZD CPU with 24V DC, Power <strong>Supply</strong>, Clock, EZ-Net EZD-CP8-NT 342.<br />
EZD CPU with 100 – 240V AC, Power <strong>Supply</strong>, Clock EZD-AC-CP8-ME 283.<br />
EZD CPU with 100 – 240V AC, Power <strong>Supply</strong>, Clock, EZ-Net EZD-AC-CP8-NT 342.<br />
EZD-CP4-800 Attached to EZ-80 Display and EZ800 Unit<br />
EZ 500/700/800/EZD Intelligent Relays<br />
Table 25. EZD Display to EZ Communication Modules (EZD-CP4)<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
EZD Display to EZ500/700 DC Communication Module with EZ500/700<br />
Communication Cable (EZD-CP4-500-CAB5)<br />
EZD Display to EZ800 DC Communication Module with EZ800<br />
Communication Cable (EZD-CP4-800-CAB5)<br />
EZD Display to EZ500/700 AC Communication Module with EZ500/700<br />
Communication Cable (EZD-CP4-500-CAB5)<br />
EZD Display to EZ800 AC Communication Module with EZ800<br />
Communication Cable (EZD-CP4-800-CAB5)<br />
EZD-CP4-500 104.<br />
EZD-CP4-800 104.<br />
EZD-AC-CP4-500 160.<br />
EZD-AC-CP4-800 160.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
23<br />
Technical Data and Specifications<br />
Table 26. EZ500 Series<br />
Type EZ512-AB… EZ512-AC… EZ512-DA… EZ512-DC-R… EZ512-DC-TC.<br />
<strong>Supply</strong> Voltage 24V AC 100 – 240V AC 12V DC 24V DC 24V DC<br />
Heat Dissipation 5 VA 5 VA 2 W 2 W 2 W<br />
Continuous Current Outputs (1) 8 A 8 A 8 A 8 A 0.5 A<br />
Short-circuit Proof with Power Factor 1 Line Protection B16, 600 A —<br />
Short-circuit Proof with Power Factor 0.7…0.7 Line Protection B16, 900 A —<br />
Mounting<br />
On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />
Table 27. EZ700 Series<br />
Type EZ719-AB… EZ719-AC… EZ719-DA… EZ719-DC-RC. EZ721-DC-TC.<br />
<strong>Supply</strong> Voltage 24V AC 100 – 240V AC 12V DC 24V DC 24V DC<br />
Heat Dissipation 7 VA 10 VA 3.5 W 3.5 W 3.5 W<br />
Continuous Current Outputs (1) 8 A 8 A 8 A 8 A 0.5 A<br />
Short-circuit Proof with Power Factor 1 Line protection B16, 600 A —<br />
Short-circuit Proof with Power Factor 0.7…0.7 Line protection B16, 900 A —<br />
Mounting<br />
On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />
Table 28. EZ800 Series<br />
Type EZ819-AC… EZ819-DC-RC. EZ820-DC-RC. EZ821-DC-TC. EZ822-DC-TC.<br />
<strong>Supply</strong> Voltage 100 – 240V AC 24V DC 24V DC 24V DC 24V DC<br />
Heat Dissipation 10 VA 3.4 W 3.4 W 3.4 W 3.4 W<br />
Continuous Current Outputs (1) 8 A 8 A 8 A 8 A 0.5 A<br />
Short-circuit Proof with Power Factor 1 Line protection B16, 600 A —<br />
Short-circuit Proof with Power Factor 0.7…0.7 Line protection B16, 900 A —<br />
Mounting<br />
On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />
Table 29. EZD CP4 and CP8 Modules<br />
Type EZD-80… EZD-CP4-… EZD-CP8… EZD-AC-CP8…<br />
<strong>Supply</strong> Voltage <strong>Supply</strong> from -CP 24V DC 24V DC 100 – 240V AC<br />
Heat Dissipation 3 W 1.5 W 3 W 8 VA<br />
Mounting<br />
Front Mounting in<br />
2 x 22.5 mm Standard<br />
Drill Holes<br />
Snap Fitted to EZD-80 Snap Fitted to EZD-80 or on Top-hat Rail to<br />
DIN 50022, 35 mm or Screw Mounting with<br />
EZB4-101-GF1 Fixing Brackets<br />
Table 30. EZ500, EZ700, EZ800, EZD-80, EZD-CP4, EZD-CP8 Modules<br />
Type EZD-80… EZ500/700/800, EZD-CP4/CP8<br />
Connection Cables — 0.2 – 4.0 mm2 (AWG 22-12), solid<br />
0.2 - 2.5 mm2 (AWG 22-12), flexible<br />
Degree of Protections IP65 IP 20<br />
RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4 EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />
Ambient Operating Temperature Clearly Legible at -5 to 50ºC -25 to 55ºC<br />
Transport and Storage Temperature -40 to 70ºC -40 to 70ºC<br />
Certification, Standards EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />
CA05001001E<br />
For more information visit: www.eaton.com
24<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
May 2007<br />
Dimensions<br />
EZ500<br />
0.42<br />
(10.8)<br />
1.97<br />
(50.0)<br />
1.77<br />
(45.0)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.28<br />
(58.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.41<br />
(35.8)<br />
2.81<br />
(71.5)<br />
Figure 18. EZ500 Series Dimensions in Inches (mm), Drawing Number MD05013001E<br />
EZ600<br />
EZ700<br />
0.64<br />
(16.3)<br />
2.96<br />
(75.0)<br />
0.64<br />
(16.3)<br />
3.54<br />
(90.0)<br />
1.77<br />
(45.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.28<br />
(58.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
4.23<br />
(107.5)<br />
Figure 19. EZ600 and EZ700 Series Dimensions in Inches (mm), Drawing Number MD05013002E<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
25<br />
EZ800<br />
0.64<br />
(16.3)<br />
2.96<br />
(75.0)<br />
0.64<br />
(16.3)<br />
3.54<br />
(90.0)<br />
1.77<br />
(45.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.91<br />
(48.5)<br />
2.78<br />
(70.5)<br />
2.83<br />
(72.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
4.23<br />
(107.5)<br />
Figure 20. EZ800 Series Dimensions in Inches (mm), Drawing Number MD05013003E<br />
EZD-80<br />
0.89<br />
(22.5)<br />
EZD-80<br />
0.67<br />
(17.0)<br />
1.26<br />
(32.0)<br />
3.41<br />
(86.5)<br />
0.88 +0.02<br />
(22.3) +0.4<br />
1.18<br />
(30.0)<br />
EZD-CP...<br />
1.11<br />
(28.3)<br />
±0.01<br />
±0.2<br />
2.44<br />
(62.0)<br />
1.11<br />
(28.3)<br />
0.79<br />
(20.0)<br />
0.54<br />
(13.7)<br />
1.18<br />
(30.0)<br />
3.41<br />
(86.5)<br />
Template for Holes, Scale 1:1<br />
Figure 21. EZD-80 Series Dimensions in Inches (mm), Drawing Number MD05013005E<br />
CA05001001E<br />
For more information visit: www.eaton.com
26<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ 500/700/800/EZD Intelligent Relays<br />
May 2007<br />
EZD-CP8<br />
0.64<br />
(16.3)<br />
2.95<br />
(75.0)<br />
0.640<br />
(16.3)<br />
3.54<br />
(90.0)<br />
1.53<br />
(38.8)<br />
1.18 ±0.01<br />
(30.0) ±0.2<br />
4.23<br />
(107.5)<br />
1.53<br />
(38.8)<br />
0.18<br />
(4.5)<br />
1.16<br />
(29.5)<br />
Figure 22. EZD-CP8 Series Dimensions in Inches (mm), Drawing Number MD05013006E<br />
1-6<br />
-0.24<br />
(0.04)<br />
EZD-80<br />
EZD-CP4<br />
0.81<br />
(20.5)<br />
1.70<br />
(43.2)<br />
EZD-CP4<br />
EZD-CP4<br />
2.28<br />
(58.0)<br />
1.08<br />
(27.5)<br />
0.89<br />
(22.5)<br />
1.18<br />
(30.0)<br />
0.89<br />
(22.5)<br />
1.43<br />
(36.2)<br />
2.95<br />
(75.0)<br />
Figure 23. EZD-CP4, EZD-80 and EZD-CP4 Series Combined Dimensions in Inches (mm), Drawing Number MD013013E<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZD Controller I/O Modules<br />
27<br />
EZD Controller I/O Modules<br />
Product Selection<br />
Table 31. EZD Controller I/O Modules<br />
Description Inputs Outputs Catalog<br />
110 – 240V AC 24V DC Analog Relay Transistor Analog<br />
Number<br />
Price<br />
U.S. $<br />
16 I/O<br />
16 I/O<br />
17 I/O<br />
16 I/O<br />
17 I/O<br />
12<br />
—<br />
—<br />
—<br />
—<br />
—<br />
12<br />
12<br />
12<br />
12<br />
—<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
4<br />
—<br />
—<br />
—<br />
—<br />
—<br />
4<br />
4<br />
—<br />
—<br />
1<br />
—<br />
1<br />
EZD-AC-R16<br />
EZD-R16<br />
EZD-RA17<br />
EZD-T16<br />
EZD-TA17<br />
120.<br />
120.<br />
156.<br />
120.<br />
156.<br />
Note: Analog inputs optional.<br />
Technical Data and Specifications<br />
Table 32. EZD Specifications<br />
Type EZD-AC-R16 EZD-R16 EZD-RA17 EZD-T16 EZD-TA17<br />
<strong>Supply</strong> Voltage<br />
<strong>Supply</strong> via EZD-CP8 module<br />
Heat Dissipation 0.5 W 0.5 W 0.5 W 0.5 W 0.5 W<br />
Continuous Current Outputs 8 A 8 A 8 A 0.5 A 0.5 A<br />
Short-circuit Proof with Power Factor 1 Line protection B16, 600 A — —<br />
Short-circuit Proof with Power Factor 0.7…0.7 Line protection B16, 900 A — —<br />
Connection Cables<br />
0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />
0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />
Degree of Protections IP 20 IP 20 IP 20 IP 20 IP 20<br />
RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />
Ambient Operating Temperature -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC<br />
Transport and Storage Temperature -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC<br />
Certification, Standards<br />
EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />
Mounting<br />
Snap Fitted to EZD-CP8 Module<br />
Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A/24V DC, max 4 outputs switchable in parallel.<br />
Dimensions<br />
EZD-R<br />
EZD-T I/O<br />
3.54<br />
(90.0)<br />
3.47<br />
(88.1)<br />
0.75<br />
(19.0)<br />
0.98<br />
(25.0)<br />
Figure 24. EZD-R/EZD-T I/O Module Dimensions in Inches (mm), Drawing Number MD05013007E<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
CA05001001E<br />
For more information visit: www.eaton.com
28<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Expansion Modules<br />
May 2007<br />
EZ/EZD Expansion Modules<br />
EZ/EZD Expansion Modules<br />
Product Description<br />
Expansion modules are available for<br />
increasing the input/output of the<br />
EZ700/800 and EZD intelligent relays to<br />
24 inputs and up to 16 outputs. Expansion<br />
modules can be mounted directly<br />
to the EZ/EZD unit or up to 98 ft. (30 m)<br />
away using coupling module EZ200-EZ.<br />
Product Selection<br />
Table 33. EZ/EZD I/O Expansion Modules <br />
Description Inputs Outputs Catalog<br />
110 – 240V 24V DC RY TRN Number<br />
AC<br />
All expansion modules include one EZ-LINK-DS.<br />
Technical Data and Specifications<br />
Table 34. EZ Specifications<br />
Relay = 8A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A/24V DC,<br />
max 4 outputs switchable in parallel.<br />
Dimensions<br />
Price<br />
U.S. $<br />
2 I/O Expansion — — 2 — EZ202-RE 52.<br />
18 I/O Expansion 12 — 6 — EZ618-AC-RE 152.<br />
18 I/O Expansion — 12 6 — EZ618-DC-RE 152.<br />
20 I/O Expansion — 12 — 8 EZ620-DC-TE 152.<br />
Coupling Module for Remote Mounting of Expansion Modules EZ200-EZ 41.<br />
Type EZ202-RE EZ618-AC-RE EZ618-DC-RE EZ620-DC-TE EZ200EZ<br />
<strong>Supply</strong> Voltage — 100 – 240V AC 24V AC 24V AC —<br />
Heat Dissipation 1 W 10 VA 4 W 4 W 1 W<br />
Continuous<br />
8 A 8 A 8 A 0.5 A —<br />
Current Outputs <br />
Short-circuit Proof Line Protection B16, 600 A —<br />
with Power Factor 1<br />
Short-circuit Proof with Line Protection B16, 900 A —<br />
Power Factor 0.7…0.7<br />
Connection Cables 0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />
0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />
Degree of Protections IP 20 IP 20 IP 20 IP 20 IP 20<br />
RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />
Ambient Operating -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC<br />
Temperature<br />
Transport and Storage -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC<br />
Temperature<br />
Certification, Standards EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />
Mounting<br />
On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with<br />
EZB4-101-GF1 Fixing Brackets<br />
EZ600<br />
EZ700<br />
0.64<br />
(16.3)<br />
2.96<br />
(75.0)<br />
0.64<br />
(16.3)<br />
3.54<br />
(90.0)<br />
1.77<br />
(45.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.28<br />
(58.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
4.23<br />
(107.5)<br />
Figure 25. EZ600 and EZ700 Series Dimensions in Inches (mm), Drawing Number MD05013002E<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Expansion Modules<br />
29<br />
EZ202-RE<br />
EZ200-EZ<br />
EZ205-ASI<br />
0.30<br />
(7.5)<br />
3.54<br />
(90.0)<br />
1.77<br />
(45.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.28<br />
(58.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.40<br />
(35.5)<br />
0.30<br />
(7.5)<br />
Figure 26. EZ202-RE/EZ200-EZ/EZ205-ASI Series Dimensions in Inches (mm), Drawing Number<br />
MD05013012E<br />
CA05001001E<br />
For more information visit: www.eaton.com
30<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Communication Modules<br />
May 2007<br />
EZ/EZD Communication<br />
Modules<br />
Product Selection<br />
Table 35. EZ/EZD Communication Interface Modules<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
PROFIBUS-DP Slave Interface Module EZ204-DP 257.<br />
AS-Interface Slave with 4 In and<br />
EZ205-ASI 94.<br />
4 Out Interface Module<br />
CANopen Interface Module EZ221-CO 247.<br />
DeviceNet Slave Interface Module EZ222-DN 247.<br />
Ethernet/IP Gateway EZ209-SE 289.<br />
Technical Data and Specifications<br />
Table 36. EZ/EZD Specifications<br />
Type EZ204-DP EZ205-ASI EZ221-CO EZ222-DN<br />
EZ204-DP Communication Module<br />
Product Description<br />
Four modules are available for easily<br />
connecting to world-standard networks.<br />
The communication modules<br />
can be used with the EZ700/800 and<br />
EZD intelligent relays.<br />
Available communication modules<br />
support:<br />
■ PROFIBUS-DP<br />
■ AS-I (Actuator Sensor Interface)<br />
networks<br />
■ CANopen<br />
■ DeviceNet<br />
■ Ethernet/IP<br />
All modules act as a gateway and<br />
operate exclusively as a slave station<br />
on the network.<br />
<strong>Supply</strong> Voltage 24V DC 24V DC 24V DC 24V DC<br />
Heat Dissipation 2 W 1 W 1 W 1 W<br />
Connection Cables<br />
0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />
0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />
Degree of Protections IP 20 IP 20 IP 20 IP 20<br />
RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1,2,3,4<br />
Ambient Operating Temperature -25 to 55ºC -25 to 55ºC -25 to 55ºC -25 to 55ºC<br />
Transport and Storage Temperature -40 to 70ºC -40 to 70ºC -40 to 70ºC -40 to 70ºC<br />
Certification, Standards<br />
EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />
Mounting<br />
On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting<br />
with EZB4-101-GF1 Fixing Brackets<br />
Dimensions<br />
EZ221-CO<br />
EZ222-DN<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.77<br />
(45.0)<br />
0.30<br />
(7.5)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.64<br />
(67.0)<br />
1.40<br />
(35.5)<br />
0.30<br />
(7.5)<br />
Figure 27. EZ221-CO/EZ222-DN Series Dimensions in Inches (mm), Drawing Number<br />
MD05013010E<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ Software<br />
31<br />
EZ204-DP<br />
0.30<br />
(7.5)<br />
EZ Software<br />
1.77<br />
(45.0)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.44<br />
(62.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.40<br />
(35.5)<br />
0.30<br />
(7.5)<br />
Figure 28. EZ204-DP Series Dimensions in Inches (mm), Drawing Number MD05013011E<br />
EZ202-RE<br />
EZ200-EZ<br />
EZ205-ASI<br />
0.30<br />
(7.5)<br />
EZSoft Software<br />
Product Description<br />
The EZSoft software is used to program<br />
all of the EZ and EZD controllers and<br />
displays. The Windows-based software<br />
provides straightforward circuit diagram<br />
input and editing and the diagrams<br />
can be displayed in the format desired.<br />
When EZ800 and EZD controllers are<br />
connected using EZ-NET, all connected<br />
devices can be accessed and their programs<br />
loaded from a single controller.<br />
EZSoft includes an integrated offline<br />
simulation tool that allows users to<br />
test a circuit diagram before commissioning.<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.28<br />
(58.0)<br />
1.77<br />
(45.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.40<br />
(35.5)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
0.30<br />
(7.5)<br />
4.33<br />
(110.0)<br />
Product Selection<br />
Table 37. EZ/EZD Software<br />
Description<br />
Catalog<br />
Number<br />
Programming Software<br />
for EZ500/700/800 and<br />
EZD<br />
Price<br />
U.S. $<br />
EZSOFT 195.<br />
Figure 29. EZ202-RE/EZ200-EZ/EZ205-ASI Series Dimensions in Inches (mm), Drawing Number<br />
MD05013012E<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
CA05001001E<br />
For more information visit: www.eaton.com
32<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Power Supplies<br />
May 2007<br />
EZ/EZD Power Supplies<br />
Product Selection<br />
Table 38. EZ/EZD-CP8 Power Supplies<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
100 – 240V AC Input to 12V DC at 20 mA/24V DC at 250 mA EZ200-POW 41.<br />
100 – 240V AC Input to 24V DC at 1.25 A EZ400-POW 68.<br />
Technical Data and Specifications<br />
Table 39. EZ Specifications<br />
Type EZ200-POW EZ400-POW<br />
<strong>Supply</strong> Voltage 100 – 240V AC 100 – 240V AC<br />
Maximum Range 85 – 264V AC 85 – 264V AC<br />
Output Voltage 24V DC (±3%) 24V DC (±3%)<br />
Output Current (Rated Value) 0.25 A 1.25 A<br />
Overcurrent Limitation Form 0.3 A 1.4 A<br />
Short-circuit Proof (Secondary) YES YES<br />
Overload Proof YES YES<br />
Potential Isolation (prim/sec.) YES, SELV, (to EN 600950, VDE 805) YES, SELV, (to EN 600950, VDE 805)<br />
Others Additional Output Voltage 12 dc, 20 mA Additional Output Voltage 12 dc, 20 mA<br />
Connection Cables<br />
0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />
0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />
0.2 – 4.0 mm 2 (AWG 22-12), Solid<br />
0.2 – 2.5 mm 2 (AWG 22-12), Flexible<br />
Degree of Protections IP 20 IP 20<br />
RFI Suppression EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1, 2, 3, 4 EN 55011, EN 55022 Class B, <strong>IEC</strong> 61000-6-1, 2, 3, 4<br />
Ambient Operating Temperature -25 to 55ºC -25 to 55ºC<br />
Transport and Storage Temperature -40 to 70ºC -40 to 70ºC<br />
Certification, Standards EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA EN 50178, <strong>IEC</strong>/EN 60947, UL, CSA<br />
Mounting<br />
On Top-hat Rail to DIN 50022, 35 mm or Screw Mounting with EZB4-101-GF1 Fixing Brackets<br />
Dimensions<br />
0.42<br />
(10.8)<br />
EZ400-POW<br />
1.97<br />
(50.0)<br />
EZ200-POW<br />
EZ256-HCI<br />
0.30<br />
(7.5)<br />
1.77<br />
(45.0)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
1.41<br />
(35.8)<br />
2.81<br />
(71.5)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.40<br />
(35.5)<br />
0.30<br />
(7.5)<br />
Figure 30. EZ200-POW/EZ256-HCI and EZ400-POW Series Dimensions in Inches (mm), Drawing Number MD05013004E<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Accessories<br />
33<br />
EZ/EZD Accessories<br />
Table 42. EZ/EZD Cables and Connectors<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S.<br />
EZ700/500 Panel Window and Mounting Kit<br />
Product Selection<br />
Table 40. EZ/EZD Memory Storage Modules<br />
Description<br />
EZ500/700 32K<br />
Memory Storage<br />
Module<br />
EZ800/EZD 256K<br />
Memory Storage<br />
Module<br />
Table 41. EZ/EZD Programming Cables<br />
Description<br />
EZ500/700 to PC<br />
Cable<br />
EZ800/EZD to PC<br />
Cable<br />
Dimensions<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
EZ-M-32K 22.<br />
EZ-M-256K 33.<br />
Catalog<br />
Number<br />
EZ-PC-CAB<br />
EZ800-PC-CAB<br />
Price<br />
U.S. $<br />
56.<br />
82.<br />
EZ500/700 to EZD-CP4 Communication Cable, 5 m EZD-CP4-500-CAB5 50.<br />
EZ800 to EZD-CP8 Communication Cable, 2 m<br />
EZ800 to EZD-CP8 Communication Cable, 5 m<br />
EZ800 to EZD-CP4 Communication Cable, 5 m<br />
EZ800/EZD EZ-NET Cable, 0.3 m<br />
EZ800/EZD EZ-NET Cable, 0.8 m<br />
EZ800/EZD EZ-NET Cable, 1.5 m<br />
EZ800/EZD Network Termination Resistor, 2/Pack<br />
EZ800/EZD EZ-NET Cable (cable only, no connectors, see<br />
EZ-NT-RJ45), 100 m<br />
Table 43. EZ/EZD Miscellaneous Parts<br />
EZD-800-CAB<br />
EZD-800-CAB5<br />
EZD-CP4-800-CAB5<br />
EZ-NT-30<br />
EZ-NT-80<br />
EZ-NT-150<br />
EZ-NT-R<br />
54.<br />
92.<br />
50.<br />
9.<br />
14.<br />
21.<br />
25.<br />
EZ-NT-CAB 162.<br />
RJ45 Network Connectors for EZ-NET Cable (EZ-NT-CAB), 10/Pack EZ-NT-RJ45 4.<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S.<br />
EZ500 Relay Simulator EZ412-DC-SIM-NA 150.<br />
EZ500 Panel Window<br />
EZ700/800 Panel Window<br />
EZ500/700/800 Panel Window Mounting Kit to Front Mount Units<br />
EZ/EZD Panel Mount Brackets, 9/Pack<br />
EZ/EZD Grounding Kit<br />
EZD Display DIN Rail Mount Kit<br />
EZD Display Protective Membrane Cover<br />
EZD Display Protective Plastic Cover<br />
EZSKF-FF4<br />
EZSKF-FF6<br />
EZSKF-HA<br />
EZB4-101-GF1<br />
EZB4-102-KS1<br />
EZD-TS144<br />
EZD-XM-80<br />
EZD-XS-80<br />
EZ/EZD 6 Channel Noise Suppression Adapter EZ256-HCI 34.<br />
EZ/EZD Spare Interface Connector, Base to Expander EZ-LINK-DS 5.<br />
EZSoft Configuration Software EZSOFT 195.<br />
EZ Starter Kit (includes EZ512-DC-RC, EZ-PC-CAB,<br />
EZ412-DC-SIM-NA, EZSoft<br />
EZSTARTKIT1 475.<br />
18.<br />
21.<br />
9.<br />
13.<br />
17.<br />
10.<br />
28.<br />
28.<br />
0.42<br />
(10.8)<br />
EZ400-POW<br />
1.97<br />
(50.0)<br />
EZ200-POW<br />
EZ256-HCI<br />
0.30<br />
(7.5)<br />
1.77<br />
(45.0)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
3.54<br />
(90.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
1.41<br />
(35.8)<br />
2.81<br />
(71.5)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.40<br />
(35.5)<br />
0.30<br />
(7.5)<br />
Figure 31. EZ200-POW/EZ256-HCI and EZ400-POW Series Dimensions in Inches (mm), Drawing Number MD05013004E<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 2CD-5<br />
CA05001001E<br />
For more information visit: www.eaton.com
34<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Accessories<br />
May 2007<br />
EZD-XS-80<br />
EZD-XM-80<br />
3.74<br />
(95.0)<br />
3.48<br />
(88.5)<br />
3.41<br />
(86.5)<br />
0.98<br />
(25.0)<br />
3.48<br />
(88.5)<br />
0.89<br />
(22.5)<br />
Figure 32. EZD-XS-80 and EZD-XM-80 Series Dimensions in Inches (mm), Drawing Number MD05013009E<br />
EZ202-RE<br />
EZ200-EZ<br />
EZ205-ASI<br />
0.30<br />
(7.5)<br />
3.54<br />
(90.0)<br />
1.77<br />
(45.0)<br />
4.02<br />
(102.0)<br />
4.33<br />
(110.0)<br />
0.18<br />
(4.5)<br />
1.87<br />
(47.5)<br />
2.22<br />
(56.5)<br />
2.28<br />
(58.0)<br />
(M4)<br />
.157 DIA.<br />
(3.9)<br />
1.40<br />
(35.5)<br />
0.30<br />
(7.5)<br />
Figure 33. EZ202-RE/EZ200-EZ/EZ205-ASI Series Dimensions in Inches (mm), Drawing Number MD05013012E<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Accessories<br />
35<br />
SKF-FF4<br />
0.63<br />
(16.0)<br />
SKF-FF6<br />
0.63<br />
(16.0)<br />
2.99<br />
(76.0)<br />
2.99<br />
(76.0)<br />
3.70<br />
(94.0)<br />
0.98<br />
(25.0)<br />
5.12<br />
(130.0)<br />
0.98<br />
(25.0)<br />
Figure 34. EZSKF-FF4 and EZSKF-FF6 Series Dimensions in Inches (mm), Drawing Number MD05013014E<br />
EZSKF-HA<br />
0.43<br />
(11.0)<br />
1.89<br />
(48.0)<br />
2.60<br />
(66.0)<br />
3.23<br />
(82.0)<br />
Figure 35. EZSKF-HA Series Dimensions in Inches (mm), Drawing Number MD05013015E<br />
* 3 fixing feet sufficient<br />
* *<br />
Fitting on 35 mm Top-Hat Rail<br />
Figure 36. EZB4-101-GF1 Series<br />
* *<br />
Fitting on Mounting Plate (Horizontal)<br />
EZB4-101-GF1<br />
CA05001001E<br />
For more information visit: www.eaton.com
36<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Accessories<br />
May 2007<br />
Grounding the Screen for<br />
Top-Hat Rail<br />
Grounding the Screen for<br />
Mounting Plate<br />
Figure 37. EZB4-102-KS1 Series<br />
Connect Outputs<br />
Digital Inputs<br />
Connection<br />
Cable<br />
DEL<br />
ALT<br />
ESC<br />
OK<br />
Power <strong>Supply</strong><br />
Unit<br />
Figure 38. EZ412-DC-SIM-NA Series<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
EZ Intelligent Relays<br />
EZ/EZD Accessories<br />
37<br />
0.30 (7.5)<br />
1.77<br />
(45)<br />
3.54<br />
(90)<br />
4.02<br />
(102) (110)<br />
4.33<br />
1.77 (45)<br />
1.87 (47.5)<br />
M4<br />
2.22 (56.5) 1.40 (35.5)<br />
Figure 39. EZ256-HCI Dimensions in Inches (mm)<br />
Wiring Diagram<br />
L<br />
N<br />
> 1 A<br />
S..<br />
S..<br />
L<br />
N N I1 I2 I3 I4 I5<br />
.....<br />
N N 1 2<br />
115/230 Vh Input 115/230 Vh<br />
EZ5..-AC-..<br />
EZ7..-AC-..<br />
3 4 5 6<br />
EZ256-HCI<br />
Figure 40. EZ256-HCI Wiring Diagram<br />
CA05001001E<br />
For more information visit: www.eaton.com
38<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
May 2007<br />
IT. I/O <strong>Products</strong> D77A-DQ8, D77A-DI8<br />
and D77A-AQ8 with DeviceNet<br />
Adapter, D77D-DNA<br />
Product Description<br />
Cutler-Hammer ® Intelligent Technologies<br />
(IT.) D77A I/O Modules, which are<br />
built by Eaton’s electrical business for<br />
industrial applications, are available in<br />
8 and 16 point I/O, combination I/O and<br />
analog I/O. These modules are capable<br />
of connecting to AC or DC voltages<br />
and also to voltage or current analog<br />
I/O. Input modules have two points per<br />
isolated common while the outputs<br />
are available in relay and solid-state<br />
with two points per isolated common<br />
for most output modules. When added<br />
flexibility is needed, modules that<br />
combine inputs and outputs, AC, DC<br />
and relay are available.<br />
Application Description<br />
Typical D77A I/O Module applications<br />
use the D77A I/O as stand-alone<br />
remote I/O and in a system where<br />
motor control and I/O are required<br />
within a single customer panel.<br />
I/O and the motor control can be connected<br />
to a single network adapter.<br />
The network adapter then represents<br />
the D77A I/O and motor control as<br />
remote I/O, consuming only one network<br />
address. The network then controls<br />
and monitors the connected<br />
devices. Connecting devices is done<br />
by DIN rail back plane or by Plug-and-<br />
Play cables.<br />
D77D-DNA D77A I/O D77A I/O<br />
To Control<br />
PC or <strong>PLC</strong><br />
IT. Starters with QSNAPs<br />
Figure 41. Application — Distributed I/O and Motor Control<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
39<br />
Features, Functions and<br />
Benefits<br />
Scalable Solutions<br />
Since each application is different, the<br />
I/O offering has been designed to<br />
allow for maximum flexibility to tailor<br />
the I/O needs of our customer. The I/O<br />
product offering includes not only 8<br />
and 16 point modules but also combination<br />
I/O modules. Signal types<br />
include 24V DC I/O, 120V AC I/O, solidstate<br />
outputs, relay outputs, analog<br />
inputs and analog outputs.<br />
All Modules<br />
LED Status – When the LED is illuminated,<br />
the proper ON state signal is<br />
received at the input or the output point.<br />
Removable Lockable Terminals – To<br />
facilitate easy removal of the I/O<br />
module, the terminal block has been<br />
designed to be easily removed with<br />
the field wiring installed. A unique<br />
locking mechanism provides for easy<br />
removal of the terminal block and also<br />
positive locking of the terminal to the<br />
I/O module.<br />
Terminal Identification – Each terminal<br />
is marked for ease of wiring and troubleshooting.<br />
Isolation – Each I/O module is optically<br />
isolated between the field I/O and the<br />
network adapter.<br />
Securing Tabs – Each I/O module has a<br />
locking mechanism so that it can be<br />
positively secured to a DIN rail.<br />
Barrier Type Terminals – Each terminal<br />
has a barrier to minimize shorting of<br />
field wiring.<br />
Removal/Insertion – Each I/O module<br />
supports removal and insertion under<br />
power.<br />
Interconnection System – Each I/O<br />
module supports both a backplane<br />
style interconnect and a cable<br />
interconnect system for system<br />
communication.<br />
Points per Common – Each I/O module<br />
supports two I/O points per isolated<br />
common except for the DC output<br />
module which is four points per<br />
isolated common.<br />
Input Modules<br />
Input Filter – Each input module supports<br />
a user definable input debounce. The<br />
time can be set from 1 mS to 250 mS.<br />
Output Modules<br />
Output Safe State – Each output module supports a user definable safe state for<br />
loss of communication. The states are hold last state, ON or OFF (default).<br />
Configurable Power ON State – When the output module initially powers up and<br />
prior to system communication starting, the outputs can be preconfigured to go to<br />
a predefined state which can be ON or OFF (default).<br />
Operation<br />
When the D77A I/O Modules are properly installed and each has a properly configured<br />
Group ID, no configuration is needed for standard operation.<br />
Discrete Input Modules<br />
When a signal is present at the input point, the module responds using the following<br />
procedures:<br />
1. Optical Isolation – Optical isolation protects the I/O circuits and communication<br />
circuits from possible damage due to transients and overvoltage.<br />
2. Debounce Logic/Control – Debounce limits the effects of transients and electrical<br />
noise by requiring the input to be true for a certain period of time before<br />
the logic acknowledges a true signal. Once a true signal is achieved, the logic<br />
turns on the LED.<br />
Input<br />
Figure 42. Input Module Operation<br />
Discrete Output Modules<br />
When an output is commanded to change state, the module responds using the<br />
following procedures:<br />
1. Optical Isolation – Optical isolation protects the I/O circuits and communication<br />
circuits from possible damage due to transients and overvoltage. Once an<br />
active signal is sent to the optical isolation, the LED is activated.<br />
2. Output Drivers – The driver turns on the output point.<br />
Communication<br />
Adapter<br />
Optical<br />
Isolation<br />
LED<br />
Indication<br />
Figure 43. Output Module Operation<br />
Optical<br />
Isolation<br />
Debounce<br />
Logic/Control<br />
Output<br />
Drivers<br />
LED<br />
Indication<br />
Communication<br />
Adapter<br />
Output<br />
CA05001001E<br />
For more information visit: www.eaton.com
40<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
May 2007<br />
Analog Input Module<br />
The analog input module is single-ended uni-polar input type capable of measuring<br />
either voltage or current inputs. Each of the channels can be individually configured<br />
to be either one of the current scales or one of the voltage scales.<br />
Analog Output Module<br />
The analog output module is single-ended uni-polar output type capable of sourcing<br />
either voltage or current outputs. The analog output module requires a 24V DC<br />
source that will provide the current or voltage source for the outputs, each of the<br />
channels can be individually configured to be either one of the current scales or<br />
one of the voltage scales.<br />
Standards and Certifications<br />
Approvals<br />
Table 44. Approvals/Certifications<br />
Description<br />
Electrical/EMC<br />
ESD Immunity (<strong>IEC</strong> 61000-4-2)<br />
Radiated Immunity (<strong>IEC</strong> 61000-4-3)<br />
Fast Transient (<strong>IEC</strong> 61000-4-4)<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
RF Conducted (<strong>IEC</strong> 61000-4-6)<br />
Magnetic Field (<strong>IEC</strong> 61000-4-8)<br />
Voltage Dips (<strong>IEC</strong> 61000-4-11)<br />
Other Approvals<br />
Ingress Protection Code<br />
Radiated and Conducted Emissions<br />
Agency Certifications<br />
Specification<br />
± 8 kV air, ± 4 kV contact<br />
10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />
± 2 kV supply and control, ± 1 kV communications<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
10V, .15 – 80 MHz<br />
30A/m, 50 Hz<br />
30% dip @ 10 mS, 60% dip @ 100 mS, >95% interrupt @ 5 mS<br />
IP20<br />
EN 5011 Class A<br />
UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive)<br />
Technical Data and Specifications<br />
Table 45. Environmental Ratings<br />
Description<br />
Transportation & Storage<br />
Temperature<br />
Humidity<br />
Operating<br />
Temperature<br />
Humidity<br />
Altitude<br />
Shock <strong>IEC</strong> 68-2-27<br />
Vibration <strong>IEC</strong> 68-2-6<br />
Pollution Degree 2<br />
Enclosure<br />
IP20<br />
Specification<br />
-58° – 176°F (-50° – 80°C)<br />
5 – 95% non-condensing<br />
-13° – 131°F (-25° – 55°C) Discrete I/O<br />
-32° – 131°F (0° – 55°C) Analog I/O<br />
5 – 95% non-condensing<br />
Above 6,600 ft. (2000m) consult factory<br />
8G any direction for 11 mS<br />
10 – 55 Hz, 3G, .7 mm maximum peak-to-peak<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
41<br />
AC Input Modules — D77A-AI8, D77A-AI16<br />
Table 46. Specifications<br />
Description<br />
Nominal Input Voltage<br />
Operating Voltage<br />
Number of Inputs<br />
Points per Common 2<br />
OFF-State Voltage<br />
ON-State Voltage<br />
Nominal Input Current<br />
Signal Delay<br />
Specification<br />
120V AC<br />
80 – 140V AC<br />
8 (D77A-AI8)<br />
16 (D77A-AI16)<br />
< 30V AC<br />
> 80V AC<br />
15 mA<br />
1/2 Cycle<br />
Isolation 1,500V<br />
Module Current Draw 33 mA (D777-AI8), 46 mA (D77A-AI6)<br />
Terminal Screw Torque 7 – 9 in-lb<br />
Table 47. Operating Voltage Range — AC Input Modules<br />
OFF State Transition Region ON State<br />
0 30V AC 30V AC 80V AC 80V AC 140V AC<br />
AC Output Modules — D77A-AQ8, D77A-AQ16<br />
Table 48. Specifications<br />
Description<br />
Nominal Input Voltage<br />
Operating Voltage<br />
Number of Outputs<br />
Specification<br />
120V AC<br />
80 – 140V AC<br />
8 (D77A-AQ8)<br />
16 (D77A-AQ16)<br />
Points per Common 2<br />
Minimum Load Current (Resistive) 15 mA<br />
Maximum Current/Point (Resistive) .5A @ 30°C<br />
.1A @ 55°C<br />
Current per Module 4A (D77A-AQ8) @ 30°C<br />
8A (D77A-AQ16) @ 30°C<br />
Surge Current (10 ms)<br />
10A<br />
OFF-State Leakage<br />
2 mA<br />
Signal Delay<br />
1/2 Cycle<br />
Module Current Draw<br />
120 mA (D77A-AQ8)<br />
220 mA (D77A-AQ16)<br />
Terminal Screw Torque<br />
7 – 9 in-lb<br />
Table 49. Operating Voltage Range — AC Output Modules<br />
Transition Region<br />
ON State<br />
0 80V AC 80V AC 140V AC<br />
0<br />
8<br />
1<br />
9<br />
CR<br />
0<br />
CR<br />
8<br />
V AC<br />
C0<br />
V AC<br />
C4<br />
CR<br />
2<br />
CR<br />
9<br />
2<br />
10<br />
V AC<br />
C0<br />
V AC<br />
C4<br />
V AC<br />
3<br />
C1<br />
4<br />
V AC<br />
11<br />
C5<br />
12<br />
CR<br />
CR<br />
V AC<br />
CR<br />
2<br />
3<br />
C1<br />
4<br />
CR<br />
CR<br />
V AC<br />
CR<br />
10<br />
11<br />
C5<br />
12<br />
5<br />
13<br />
CR<br />
5<br />
CR<br />
13<br />
V AC<br />
C2<br />
V AC<br />
C6<br />
V AC<br />
C2<br />
V AC<br />
C6<br />
6<br />
14<br />
CR<br />
6<br />
CR<br />
14<br />
7<br />
15<br />
CR<br />
7<br />
CR<br />
15<br />
V AC<br />
C3<br />
V AC<br />
C7<br />
V AC<br />
C3<br />
V AC<br />
C7<br />
Figure 44. Wiring Diagram — AC Input Modules, D77A-AI8 & D77A-<br />
AI16<br />
Com<br />
Figure 46. Wiring Diagram — AC Output Modules, D77A-AQ8 &<br />
D77A-AQ16<br />
L2<br />
Out<br />
In<br />
In<br />
Figure 45. Circuit Diagram — AC Input Modules, D77A-AI8 &<br />
D77A-AI16<br />
Out<br />
Figure 47. Circuit Diagram — AC Output Modules, D77A-AQ8 &<br />
D77A-AQ16<br />
CA05001001E<br />
For more information visit: www.eaton.com
42<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
May 2007<br />
DC Input Modules — D77A-DI8, D77A-DI16<br />
Table 50. Specifications<br />
Description<br />
Nominal Input Voltage<br />
Operating Voltage<br />
Number of Inputs<br />
Specification<br />
24V DC<br />
18 – 30V DC<br />
8 (D77A-DI8)<br />
16 (D77A-DI16)<br />
Points per Common 2<br />
Signal Delay<br />
5 mS (Programmable to 250 mS)<br />
OFF-State Voltage<br />
< 6V DC<br />
ON-State Voltage<br />
> 18V DC<br />
Nominal Input Current<br />
5 mA<br />
Isolation<br />
1500V<br />
Module Current Draw<br />
35 mA (D77A-DI8)<br />
49 mA (D77A-DI16)<br />
Terminal Screw Torque<br />
7 – 9 in-lb<br />
Table 51. Operating Voltage Range — DC Input Modules<br />
OFF State Transition Region ON State<br />
0 6V DC 6V DC 18V DC 18V DC 30V DC<br />
DC Output Modules Sink — D77A-DQ8, D77A-DQ16<br />
Table 52. Specifications<br />
Description<br />
Specification<br />
Nominal Input Voltage<br />
24V DC<br />
Type<br />
MQSFET sink<br />
Operating Voltage<br />
18 – 30V DC<br />
Number of Outputs<br />
8 (D77A-DQ8)<br />
16 (D77A-DQ16)<br />
Points per Common 4<br />
Signal Delay<br />
1 mS<br />
Maximum Current/Point .75A<br />
Current per Module<br />
6A (D77D-DQ8)<br />
12A (D77D -DQ16)<br />
Surge Current (10 mS)<br />
4A<br />
OFF-State Leakage<br />
1 mA<br />
Module Current Draw<br />
85 mA (D77A-DQ8)<br />
126 mA (D77A-DQ16)<br />
Terminal Screw Torque<br />
7 – 9 in-lb<br />
Table 53. Operating Voltage Range — DC Output<br />
Transition Region<br />
ON State<br />
0<br />
8<br />
0 18V DC 18V DC 30V DC<br />
V DC<br />
V DC<br />
V DC<br />
V DC<br />
1<br />
C0<br />
2<br />
3<br />
C1<br />
4<br />
5<br />
C2<br />
6<br />
7<br />
C3<br />
V DC<br />
V DC<br />
V DC<br />
V DC<br />
9<br />
C4<br />
10<br />
11<br />
C5<br />
12<br />
13<br />
C6<br />
14<br />
15<br />
C7<br />
CR<br />
CR<br />
CR<br />
CR<br />
COM<br />
V DC<br />
CR<br />
CR<br />
CR<br />
CR<br />
COM<br />
0<br />
1<br />
2<br />
3<br />
–<br />
+<br />
4<br />
5<br />
6<br />
7<br />
–<br />
CR<br />
CR<br />
CR<br />
CR<br />
COM<br />
V DC<br />
CR<br />
CR<br />
CR<br />
CR<br />
COM<br />
8<br />
9<br />
10<br />
11<br />
–<br />
+<br />
12<br />
13<br />
14<br />
15<br />
–<br />
Figure 48. Wiring Diagram — DC Input Modules, D77A-DI8 &<br />
D77A-DI16<br />
In<br />
In<br />
V DC<br />
+<br />
V DC<br />
Figure 50. Wiring Diagram — DC Output Modules Sink, D77A-DQ8 &<br />
D77A-DQ16<br />
+<br />
+24<br />
Out<br />
Com<br />
Figure 49. Circuit Diagram — DC Input Modules, D77A-DI8 &<br />
D77A-DI16<br />
Out<br />
C<br />
Figure 51. Circuit Diagram — DC Output Modules Sink, D77A-DQ8 &<br />
D77A-DQ16<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
43<br />
DC Output Modules Source —<br />
D77A-DQ8C, D77A-DQ16C<br />
Table 54. DC Output Modules Specifications<br />
Description<br />
Specification<br />
Nominal Voltage<br />
24V DC<br />
Type<br />
MOSFET Source<br />
Operating Voltage<br />
18 – 30V DC<br />
Number of Outputs<br />
8 (D77A-DQ8C)<br />
16 (D77A-DQ16C)<br />
Points per Common 4<br />
Signal Delay<br />
1 mS<br />
Max. Current per Point .75A<br />
Max. Current per Module <br />
6A (D77A-DQ8C)<br />
12A (D77A-DQ16C)<br />
Surge Current (10 mS)<br />
4A<br />
OFF-State Leakage<br />
.5 mA<br />
Module Current Draw<br />
29 mA (D77A-DQ8C)<br />
45 mA (D77A-DQ16C)<br />
Resistive current at 55°C ambient.<br />
Relay Output Modules — D77A-RQ8, D77A-RQ16<br />
Table 55. Relay Output Modules Specifications<br />
Description<br />
Specification<br />
Nominal Voltage<br />
120V AC<br />
24V DC<br />
Number of Outputs<br />
8 (D77A-RQ8)<br />
16 (D77A-RQ16)<br />
Points per Common 2<br />
Relay OFF Time<br />
6 mS<br />
Relay ON Time<br />
3 mS<br />
Max. Current per Point <br />
3A<br />
Max. Current per Module 24A (D77A-RQ8)<br />
48A (D77A-RQ16)<br />
Electrical Life<br />
100,000 Cycles<br />
Mechanical Life<br />
1,000,000 Cycles<br />
Module Current Draw<br />
92 mA (D77A-RQ8)<br />
164 mA (D77A-RQ16)<br />
Resistive current at 55°C ambient.<br />
CR<br />
0<br />
CR<br />
8<br />
COM<br />
COM<br />
CR<br />
CR<br />
CR<br />
CR<br />
V DC<br />
CR<br />
CR<br />
CR<br />
CR<br />
0<br />
1<br />
2<br />
3<br />
–<br />
+<br />
4<br />
5<br />
6<br />
7<br />
–<br />
COM<br />
COM<br />
CR<br />
CR<br />
CR<br />
CR<br />
V DC<br />
CR<br />
CR<br />
CR<br />
CR<br />
0<br />
1<br />
2<br />
3<br />
–<br />
+<br />
4<br />
5<br />
6<br />
7<br />
–<br />
COM<br />
COM<br />
CR<br />
CR<br />
CR<br />
CR<br />
V DC<br />
CR<br />
CR<br />
CR<br />
CR<br />
8<br />
9<br />
10<br />
11<br />
–<br />
+<br />
12<br />
13<br />
14<br />
15<br />
–<br />
CR<br />
V AC/DC<br />
CR<br />
CR<br />
V AC/DC<br />
CR<br />
CR<br />
V AC/DC<br />
CR<br />
CR<br />
V AC/DC<br />
1<br />
C0<br />
2<br />
3<br />
C1<br />
4<br />
5<br />
C2<br />
6<br />
7<br />
C3<br />
CR<br />
V AC/DC<br />
CR<br />
CR<br />
V AC/DC<br />
CR<br />
CR<br />
V AC/DC<br />
CR<br />
CR<br />
V AC/DC<br />
9<br />
C4<br />
10<br />
11<br />
C5<br />
12<br />
13<br />
C6<br />
14<br />
15<br />
C7<br />
V DC<br />
D77A-DQ8C<br />
+<br />
V DC<br />
+<br />
V DC<br />
D77A-DQ16C<br />
+<br />
Figure 54. Wiring Diagram — Relay Output Modules, D77A-RQ8 &<br />
D77A-RQ16<br />
Figure 52. Wiring Diagram — DC Output Modules Source,<br />
D77A-DQ8C & D77A-DQ16C<br />
Out<br />
V DC<br />
Out<br />
Out (Q)<br />
V DC<br />
Out (Q)<br />
COM<br />
Figure 55. Circuit Diagram — Relay Output Modules, D77A-RQ8 &<br />
D77A-RQ16<br />
C<br />
Figure 53. Circuit Diagram — DC Output Modules Source,<br />
D77A-DQ8C & D77A-DQ16C<br />
CA05001001E<br />
For more information visit: www.eaton.com
44<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
May 2007<br />
AC Input AC Output Module — D77A-AI8AQ8<br />
Table 56. Specifications<br />
Description<br />
Resistive current at 55°C.<br />
Specification<br />
AC Input<br />
Table 57. Operating Voltage Range<br />
AC Output<br />
Nominal Voltage<br />
120V AC<br />
Operating Voltage<br />
80 – 140V AC<br />
Number of Points 8<br />
Points per Common 2<br />
Signal Delay<br />
1/2 Cycle<br />
(programmable<br />
to 250 mS)<br />
—<br />
OFF-State Voltage < 30V AC —<br />
ON-State Voltage > 80V AC —<br />
Nominal Current 15 mA —<br />
Signal Delay — 1/2 Cycle<br />
Max. Current per Point — .5A @ 30°C<br />
.1A @ 55°C<br />
Max. Current per<br />
Module — 4A @ 30°C<br />
.8A @ 55°C<br />
Surge Current (10 mS) — 10A<br />
OFF-State Leakage — 2 mA<br />
Isolation 1,500V<br />
Module Current Draw<br />
104 mA<br />
OFF State Transition Region ON State<br />
Input 0 30V AC 80V AC 140V AC<br />
Output 0V AC 80V AC 80V AC 140V AC<br />
0 CR 0<br />
1 CR<br />
V AC C0 V AC<br />
2 CR<br />
3 CR<br />
V AC C1 V AC<br />
4 CR<br />
5 CR<br />
V AC C2 V AC<br />
6 CR<br />
7 CR<br />
V AC C3 V AC<br />
Figure 56. Wiring Diagram — AC Input AC Output<br />
Com<br />
In<br />
In<br />
1<br />
C4<br />
2<br />
3<br />
C5<br />
4<br />
5<br />
C6<br />
6<br />
7<br />
C7<br />
L2<br />
Out<br />
Out<br />
Figure 57. Circuit Diagram — AC Input AC Output<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
45<br />
DC Input DC Output Module — D77A-DI8DQ8<br />
Table 58. Specifications<br />
Description<br />
Resistive current at 55°C.<br />
Specification<br />
DC Input<br />
Nominal Voltage<br />
24V DC<br />
Operating Voltage<br />
18 – 30V AC<br />
Number of Points 8<br />
Points per Common 2 4<br />
Signal Delay<br />
5 mS<br />
(programmable<br />
to 250 mS)<br />
—<br />
OFF-State Voltage < 6V DC —<br />
ON-State Voltage > 18V DC —<br />
Nominal Current 5 mA —<br />
Signal Delay — 1 mS<br />
Max. Current per Point — .75A<br />
Max. Current per<br />
— 6A<br />
Module <br />
Surge Current (10 mS) — 4A<br />
OFF-State Leakage — 1 mA<br />
Isolation 1,500V<br />
Module Current Draw<br />
99 mA<br />
Table 59. Operating Voltage Range — Input<br />
Table 60. Operating Voltage Range — Output<br />
DC Sink Output<br />
OFF State Transition Region ON State<br />
0 8V DC 8V DC 18V DC 18V DC 30V DC<br />
Transition Region<br />
ON State<br />
0 18V DC 18V DC 30V DC<br />
0 CR 0<br />
1 CR 1<br />
V DC C0 CR 2<br />
2 CR 3<br />
3 COM –<br />
V DC C1<br />
V DC<br />
+<br />
4 CR 4<br />
5 CR 5<br />
V DC C2 CR 6<br />
6 CR 7<br />
7 COM –<br />
V DC C3<br />
V DC<br />
+<br />
Figure 58. Wiring Diagram — DC Input DC Output<br />
In<br />
In<br />
Com<br />
Figure 59. Circuit Diagram — DC Input DC Output<br />
+24<br />
Out<br />
Out<br />
C<br />
CA05001001E<br />
For more information visit: www.eaton.com
46<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
May 2007<br />
AC Input Relay Output Module — D77A-AI8RQ8<br />
Table 61. Specifications<br />
Description<br />
Resistive current at 55°C.<br />
Specification<br />
AC Input<br />
Table 62. Operating Voltage Range — Input<br />
Relay Output<br />
Nominal Voltage 120V AC 120V AC<br />
24V DC<br />
Operating Voltage 80 – 140V AC 0 – 30V DC<br />
0 – 140V AC<br />
Number of Points 8<br />
Points per Common 2<br />
Signal Delay<br />
1/2 Cycle<br />
(programmable<br />
to 250 mS)<br />
—<br />
OFF-State Voltage < 30V AC —<br />
ON-State Voltage > 80V AC —<br />
Nominal Current 15 mA —<br />
Relay OFF Time — 6 mS<br />
Relay ON Time — 3 mS<br />
Max. Current per Point — 3A<br />
Max. Current per<br />
— 24A<br />
Module <br />
Electrical Life — 100,000 Cycles<br />
Mechanical Life — 1,000,000 Cycles<br />
Isolation 1,500V<br />
Module Current Draw<br />
104 mA<br />
OFF State Transition Region ON State<br />
0 30V AC 30V AC 80V AC 80V AC 140V AC<br />
0 CR 0<br />
1 CR<br />
V AC C0 V AC/DC<br />
2 CR<br />
3 CR<br />
V AC C1 V AC/DC<br />
4 CR<br />
5 CR<br />
V AC C2 V AC/DC<br />
6 CR<br />
7 CR<br />
V AC C3 V AC/DC<br />
1<br />
C0<br />
2<br />
3<br />
C1<br />
4<br />
5<br />
C2<br />
6<br />
7<br />
C3<br />
Figure 60. Wiring Diagram — AC Input Relay Output<br />
Com<br />
In<br />
In<br />
Out<br />
Out<br />
C<br />
Figure 61. Circuit Diagram — AC Input Relay Output<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
47<br />
DC Input Relay Output Module — D77A-DI8RQ8<br />
Table 63. Specifications<br />
Description<br />
Resistive current at 55°C.<br />
Specification<br />
DC Input<br />
Table 64. Operating Voltage Range — Input<br />
Relay Output<br />
Nominal Voltage 24V DC 120V AC<br />
24V DC<br />
Operating Voltage 18 – 30V DC 0 – 30V DC<br />
0 – 140V AC<br />
Number of Points 8<br />
Points per Common 2<br />
Signal Delay<br />
5 mS<br />
(programmable<br />
to 250 mS)<br />
—<br />
OFF-State Voltage < 6V DC —<br />
ON-State Voltage > 18V DC —<br />
Nominal Current 5 mA —<br />
Relay OFF Time — 6 mS<br />
Relay ON Time — 3 mS<br />
Max. Current per Point — 3A<br />
Max. Current per<br />
— 24A<br />
Module <br />
Electrical Life — 100,000 Cycles<br />
Mechanical Life — 1,000,000 Cycles<br />
Isolation 1,500V<br />
Module Current Draw<br />
106 mA<br />
OFF State Transition Region ON State<br />
0 8V DC 8V DC 18V DC 18V DC 30V DC<br />
0 CR 0<br />
1 CR<br />
V DC C4 V AC/DC<br />
2 CR<br />
3 CR<br />
V DC C5 V AC/DC<br />
4 CR<br />
5 CR<br />
V DC C6 V AC/DC<br />
6 CR<br />
7 CR<br />
V DC C7 V AC/DC<br />
1<br />
C0<br />
2<br />
3<br />
C1<br />
4<br />
5<br />
C2<br />
6<br />
7<br />
C3<br />
Figure 62. Wiring Diagram — DC Input Relay Output<br />
In<br />
In<br />
Com<br />
Out<br />
Out<br />
C<br />
Figure 63. Circuit Diagram — DC Input Relay Output<br />
CA05001001E<br />
For more information visit: www.eaton.com
48<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
May 2007<br />
Analog Input Module — D77A-NI4<br />
Table 65. D77A-NI4 — Specifications<br />
Description<br />
Specification<br />
Voltage Input<br />
0 – 5V DC, 1 – 5V DC, 0 – 10V DC<br />
Current Input<br />
4 – 20 mA, 0 – 20 mA<br />
Module Current Draw<br />
60 mA max.<br />
Input Types<br />
Single ended, Uni-polar<br />
Points 4<br />
Resolution Filter Setting Effective Resolution<br />
0 – 10V DC 0 – 5V DC, 1 – 5V DC / 4 – 20 mA, 0 – 20 mA<br />
50 Hz<br />
60 Hz<br />
250 Hz<br />
500 Hz<br />
14 bit<br />
14 bit<br />
13 bit<br />
13 bit<br />
Input Full Scale Voltage Current<br />
0 – 10.5V DC, 0 – 5.25V DC 0 – 21 mA<br />
Max Overload<br />
30V DC / 32 mA<br />
Input to Bus Isolation<br />
500V AC for 60 seconds<br />
Input Filter<br />
50 Hz, 60 Hz, 250 Hz, 500 Hz<br />
Common Mode Rejection > 60 dB @ 50 Hz and 60 Hz<br />
Normal Mode Rejection Ratio - 50 dB @ 50 Hz and 60 Hz<br />
Input Impedance Voltage Current<br />
15 M ohm 250 ohm<br />
Accuracy Voltage Current<br />
± 0.3% full scale @ 25°C<br />
± 0.4% full scale @ 0 – 55°C<br />
Update Rate Input Filter Update Time<br />
50 Hz<br />
60 Hz<br />
250 Hz<br />
500 Hz<br />
± 0.45% full scale @ 25°C<br />
± 0.5% full scale @ 0 – 55°C<br />
336 mS<br />
283 mS<br />
80 mS<br />
44 m S<br />
Input filter setting affects the effective resolution of channel.<br />
The time to update one channel when various filters are used within one module.<br />
14 bit<br />
14 bit<br />
12 bit<br />
9 bit<br />
Terminal<br />
1 V0<br />
Voltage<br />
Current<br />
2 I0<br />
i<br />
3 C0<br />
4 V1<br />
Earth ground<br />
Earth ground<br />
5<br />
I1<br />
i<br />
6 C1<br />
7 V2<br />
Earth ground<br />
Earth ground<br />
8 I2<br />
i<br />
9 C2<br />
Earth ground<br />
Earth ground<br />
10<br />
V3<br />
11<br />
I3<br />
i<br />
12<br />
C3<br />
Earth ground<br />
Earth ground<br />
Figure 64. D77A-NI4 Wiring Diagram<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series)<br />
49<br />
Analog Output Module — D77A-NQ2<br />
Table 66. D77A-NQ2 — Specifications<br />
Description<br />
Specification<br />
Voltage Output<br />
0 – 5V DC, 1 – 5V DC, 0 – 10V DC<br />
Current Output<br />
4 – 20 mA, 0 – 20 mA<br />
Module Current Draw<br />
40 mA max.<br />
External Power<br />
60A max. @ 24V DC<br />
Output Types<br />
Single ended, Uni-polar<br />
Protection<br />
Open and Short Circuit<br />
Points 2<br />
Resolution Range Resolution<br />
4 – 20 mA, 0 – 20 mA 14 bit<br />
0 – 10V DC 14 bit<br />
0 – 5V DC, 1 – 5V DC 13 bit<br />
Output Full Scale Voltage Current<br />
0 – 10.5V DC, 0 – 5.25V DC 0 – 21 mA<br />
Overvoltage Protection<br />
36V DC @ ± terminals<br />
Output to Bus Isolation<br />
1500V AC for 60 seconds<br />
Resistive Load on Current Output<br />
< 500 ohm<br />
Load Range on Voltage Output<br />
> 1 K ohm<br />
Max. Inductive Load<br />
0.1 mH<br />
Max. Capacitive Load 1 µF<br />
Output ripple (0 – 50 Hz) ± 0.1%<br />
Output Impedance<br />
10 ohm<br />
Accuracy Voltage Current<br />
0.8% full scale @ 25°C<br />
1% full scale @ 0 – 55°C<br />
Update Rate 350 µS<br />
0.8% full scale @ 25°C<br />
1% full scale @ 0 – 55°C<br />
Terminal<br />
1 V0<br />
2 I0<br />
0-5V, 1-5V, 0-10V wiring<br />
Voltage<br />
Load<br />
3 C0<br />
4 V1<br />
5 I1<br />
6 C1<br />
7 NC<br />
8 NC<br />
9 NC<br />
10 NC<br />
11<br />
12<br />
Earth ground<br />
Earth ground<br />
0-20 mA, 4-20 mA wiring<br />
External 24V DC<br />
Power <strong>Supply</strong><br />
Current<br />
Load<br />
Figure 65. D77A-NQ2 Wiring Diagram<br />
CA05001001E<br />
For more information visit: www.eaton.com
50<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Remote I/O Modules (D77A Series) — Accessories<br />
May 2007<br />
Dimensions<br />
Single<br />
Double<br />
Side<br />
2 (50.8)<br />
3.5<br />
(90)<br />
3.5<br />
(90)<br />
2<br />
(50.8)<br />
Module<br />
Module<br />
Module<br />
Module<br />
2 (50.8)<br />
Module<br />
2<br />
(50.8)<br />
Figure 67. I/O Module Ventilation —<br />
Approximate Dimensions in Inches (mm)<br />
.9<br />
(22.5)<br />
1.8<br />
(45)<br />
2.7<br />
(68)<br />
Figure 66. I/O Module — Approximate Dimensions in Inches (mm)<br />
Product Selection<br />
Table 67. D77A- I/O Module Product Selection<br />
Description<br />
Max.<br />
Output<br />
Current per<br />
Point<br />
Points per<br />
Common<br />
Size<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
8 Point 24V DC Input<br />
16 Point 24V DC Input<br />
8 Point 24V DC Solid-State Output<br />
16 Point 24V DC Solid-State Output<br />
8 Point 120V AC Input<br />
16 Point 120V AC Input<br />
8 Point 120V AC Solid-State Output<br />
16 Point 120V AC Solid-State Output<br />
8 Point Relay Output (24V DC/120V AC)<br />
16 Point Relay Output (24V DC/120V AC)<br />
8 Point 24V DC Input / 8 Point 24V DC Output<br />
8 Point 24V DC Input / 8 Point Relay Output<br />
8 Point 120V AC Input / 8 Point 120V AC Output<br />
8 Point Relay Output / 8 Point 120V AC Input<br />
4 Point Analog Input<br />
2 Point Analog Output<br />
N/A<br />
N/A<br />
.75 Amp<br />
.75 Amp<br />
N/A<br />
N/A<br />
.5 Amp<br />
.5 Amp<br />
3 Amp<br />
3 Amp<br />
.75 Amp<br />
3 Amp<br />
.5 Amp<br />
3 Amp<br />
N/A<br />
N/A<br />
2<br />
2<br />
4<br />
4<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2 (in), 4 (out)<br />
2 (in), 2 (out)<br />
2 (in), 2 (out)<br />
2 (in), 2 (out)<br />
4<br />
2<br />
Single<br />
Double<br />
Single<br />
Double<br />
Single<br />
Double<br />
Single<br />
Double<br />
Single<br />
Double<br />
Double<br />
Double<br />
Double<br />
Double<br />
Single<br />
Single<br />
D77A-DI8<br />
D77A-DI16<br />
D77A-DQ8<br />
D77A-DQ16<br />
D77A-AI8<br />
D77A-AI16<br />
D77A-AQ8<br />
D77A-AQ16<br />
D77A-RQ8<br />
D77A-RQ16<br />
D77A-DI8DQ8<br />
D77A-DI8RQ8<br />
D77A-AI8AQ8<br />
D77A-AI8RQ8<br />
D77A-NI4<br />
D77A-NQ2<br />
171.00<br />
227.00<br />
239.00<br />
299.00<br />
200.00<br />
268.00<br />
258.00<br />
411.00<br />
201.00<br />
381.00<br />
306.00<br />
314.00<br />
392.00<br />
345.00<br />
431.00<br />
431.00<br />
Accessories<br />
Table 68. I/O Module Product Accessories<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
7-Position Backplane with DIN Rail<br />
12-Position Backplane with DIN Rail<br />
25 cm Interconnect Plug-and-Play Cable<br />
1 Meter Interconnect Plug-and-Play Cable<br />
2 Meter Interconnect Plug-and-Play Cable<br />
3 Meter Interconnect Plug-and-Play Cable<br />
D77E-BP7<br />
D77E-BP12<br />
D77E-QPIP25<br />
D77E-QPIP100<br />
D77E-QPIP200<br />
D77E-QPIP300<br />
66.00<br />
90.00<br />
33.25<br />
38.75<br />
44.25<br />
49.75<br />
I/O Terminator DIN Style and Power Tap D77E-QPLR 99.50<br />
I/O Terminator RJ11 Style D77E-TERRJ 38.75<br />
Figure 68. Backplane with DIN Rail<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Starter Network Adapters (SNAP) (D77B Series) — DeviceNet SNAP<br />
51<br />
DeviceNet Starter Network<br />
Adapter Product (DSNAP)<br />
Catalog Number D77B-DSNAP-X3<br />
with 54 mm IT. Starter<br />
Product Description<br />
The Cutler-Hammer ® DeviceNet Starter<br />
Network Adapter Product (DSNAP)<br />
from Eaton’s electrical business is a<br />
front-mount device that serves as a<br />
single node on DeviceNet, providing<br />
communication capability, control and<br />
monitoring to Intelligent Technologies<br />
(IT.) Electromechanical Starters, as<br />
well as the S751 and S752 Soft Start,<br />
as listed in Tables 69 – 71.<br />
The IT. DSNAP has an optional HANDS/<br />
OFF/AUTO (HOA) module that enables<br />
the starter to be operated in hand<br />
mode; even if the DSNAP is not powered.<br />
The HOA option is used for customers<br />
who need the extra security of<br />
manual control in conjunction with the<br />
communication capabilities of<br />
DeviceNet.<br />
IT. Starter<br />
with<br />
DSNAP<br />
Figure 69. Typical DSNAP Application<br />
With the addition of a D64 zero<br />
sequence CT, the DSNAP can be<br />
enabled to detect ground faults for<br />
added protection.<br />
Features<br />
■ Communication to DeviceNet consuming<br />
one DeviceNet MAC ID<br />
■ Manually set MAC ID and baud rate;<br />
configuration using a software<br />
application is not required for normal<br />
operation<br />
■ Advanced configuration using<br />
CH Studio<br />
■ Includes pre-wired starter interconnect<br />
cable and terminal adapter<br />
Comprehensive Motor Data and<br />
Control<br />
■ RMS average current<br />
■ % of operating FLA<br />
■ % thermal memory<br />
■ Integral contact position detection<br />
■ Operating status and fault codes<br />
■ At speed (soft starters)<br />
■ START/STOP control<br />
■ RUN/FORWARD-REVERSE control<br />
■ Trip Reset<br />
Extended Starter Capabilities<br />
■ Ground fault detection (with<br />
accessory)<br />
■ Fault log<br />
■ Overcurrent warning (adjustable)<br />
■ Undercurrent warning (adjustable)<br />
DeviceNet<br />
Table 69. <strong>IEC</strong> SNAP Connectivity<br />
<strong>IEC</strong> E101, E501<br />
Frame Size Continuous<br />
Ampacity<br />
Rating<br />
45 mm B 18 Amp<br />
25 Amp<br />
32 Amp<br />
54 mm C 40 Amp<br />
50 Amp<br />
76 mm D 65 Amp<br />
85 Amp<br />
100 Amp<br />
105 mm E 125 Amp<br />
160 Amp<br />
200 Amp<br />
140 mm F 250 Amp<br />
315 Amp<br />
420 Amp<br />
Table 70. NEMA SNAP Connectivity<br />
NEMA N101, N501<br />
Size<br />
Continuous Ampacity<br />
Rating<br />
00 9<br />
0 18<br />
1 27<br />
2 45<br />
3 90<br />
4 135<br />
5 270<br />
Table 71. S751/S752 SNAP Connectivity<br />
S751/S752 Soft Start<br />
54 mm All Sizes<br />
Application Description<br />
In a typical application, the DSNAP<br />
front mounts to an IT. starter or soft<br />
start. The DSNAP connects directly to<br />
DeviceNet, allowing for control and<br />
monitoring of the starter/soft start. A<br />
PC or <strong>PLC</strong> serves as the central control<br />
and scans the DSNAP for motor control<br />
and monitoring information. The<br />
HOA module provides for the ability<br />
to locate operators on the panel for<br />
manual operation.<br />
CA05001001E<br />
For more information visit: www.eaton.com
52<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Starter Network Adapters (SNAP) (D77B Series) — DeviceNet SNAP<br />
May 2007<br />
Standards and Certifications<br />
Approvals<br />
Table 72. Approvals/Certifications<br />
Description<br />
Specification<br />
Electrical/EMC<br />
ESD Immunity<br />
± 8 kV air, ± 4 kV contact<br />
(<strong>IEC</strong> 61000-4-2)<br />
Radiated Immunity<br />
(<strong>IEC</strong> 61000-4-3)<br />
Fast Transient<br />
(<strong>IEC</strong> 61000-4-4)<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
RF Conducted<br />
(<strong>IEC</strong> 61000-4-6)<br />
Magnetic Field<br />
(<strong>IEC</strong> 61000-4-8)<br />
Voltage Dips<br />
(<strong>IEC</strong> 61000-4-11)<br />
Other Approvals<br />
Ingress Protection Code<br />
(<strong>IEC</strong> 60947-1)<br />
Radiated and Conducted<br />
Emissions<br />
Technical Data and Specifications<br />
Table 73. DeviceNet Specifications<br />
DeviceNet Connections Group 2 Slave<br />
Polling<br />
Explicit<br />
No UCMM<br />
10V/m 80 – 1,000 MHz, 80% amplitude<br />
modulation @ 1 kHz<br />
± 2 kV supply and control, ± 1 kV<br />
communications<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
10V, .15 – 80 MHz<br />
30A/m, 50 Hz<br />
30% dip @ 10 mS, 60% dip @ 100 mS,<br />
>95% interrupt @ 5 mS<br />
IP20<br />
EN 5011 Class A<br />
Agency Certifications UL 508, CUL (CSA C22.2 No. 14),<br />
CE (Low Voltage Directive),<br />
ODVA Conformance Tested<br />
DeviceNet Baud Rate<br />
125K, 250K, 500K<br />
Dimensions<br />
2.4<br />
(62)<br />
Figure 70. DSNAP Approximate Dimensions in Inches (mm)<br />
Product Selection<br />
Table 75. Product Selection<br />
Description<br />
Front<br />
1.0<br />
(26)<br />
Side<br />
1.9<br />
(49)<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
DSNAP Kit for FVNR Starters D77B-DSNAP-X1 335.00<br />
DSNAP Kit for FVR Starters D77B-DSNAP-X2 371.00<br />
DSNAP Kit for FVNR Starters with HOA D77B-DSNAP-X3 390.00<br />
DSNAP Kit for FVR Starters with HOA D77B-DSNAP-X4 458.00<br />
DSNAP Adapter for Size 5 and<br />
D77B-140A 47.25<br />
Size F Frame Starters<br />
SNAP Auxiliary Connector D77B-AC1 42.00<br />
Note: For D64 zero sequence CTs refer to Tab 49 in Publication No.<br />
CA08102001E.<br />
Table 74. Environmental Ratings<br />
Description<br />
Specifications<br />
Transportation/Storage<br />
Temperature<br />
-58° to 176°F (-50° to 80°C)<br />
Humidity<br />
5 – 95% non-condensing<br />
Operating<br />
Temperature<br />
-4° to 131°F (-20° to 55°C)<br />
Humidity<br />
5 – 95% non-condensing<br />
Altitude<br />
Above 2000 meters (6600 feet) consult factory<br />
Pollution Degree 2<br />
Power Draw<br />
90 mA Steady State<br />
Shock (<strong>IEC</strong> 68-2-27) 15G any direction for 11 mS<br />
Vibration (<strong>IEC</strong> 68-2-6) 5 – 150 Hz, 5G, .7 mm max. peak-to-peak<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Starter Network Adapters (SNAP) (D77B Series) — QCPort SNAP<br />
53<br />
QCPort Starter Network<br />
Adapter Product (QSNAP)<br />
Catalog Number D77B-QSNAP-X1<br />
with 54 mm IT. Starter<br />
Product Description<br />
The Cutler-Hammer ® QCPort Starter<br />
Network Adapter Product (QSNAP)<br />
from Eaton’s electrical business is a<br />
front-mount device providing communication<br />
capability, control and monitoring<br />
to Intelligent Technologies (IT.)<br />
Electromechanical Starters, as well as<br />
the S751 and S752 Soft Start, as listed<br />
in Tables 76 – 78. The QSNAP allows<br />
connection to any communications<br />
adapter and provides access to any<br />
support network.<br />
The IT. QSNAP has an optional HANDS/<br />
OFF/AUTO (HOA) module that enables<br />
the starter to be operated in hand<br />
mode; even if the QSNAP is not powered.<br />
The HOA option is used for customers<br />
who need the extra security of<br />
manual control in conjunction with<br />
industrial network communication<br />
capabilities.<br />
D77D-EIP, D77D-EMA,<br />
D77D-DNA, D77D-PNA<br />
To Control<br />
PC or <strong>PLC</strong><br />
With the addition of a D64 zero<br />
sequence CT, the QSNAP can be<br />
enabled to detect ground faults for<br />
added protection.<br />
Features<br />
■ Starter/contactor connectivity connecting<br />
motor control and I/O on<br />
same communication adapter<br />
■ Configuration using a software<br />
application is not required for normal<br />
operation<br />
■ Advanced configuration using<br />
CH Studio<br />
■ Includes pre-wired starter interconnect<br />
cable and terminal adapter<br />
Comprehensive Motor Data and<br />
Control<br />
■ RMS average current<br />
■ % of operating FLA<br />
■ % thermal memory<br />
■ Integral contact position detection<br />
■ Operating status and fault codes<br />
■ At speed (soft starters)<br />
■ START/STOP control<br />
■ RUN/FORWARD-REVERSE control<br />
■ Trip Reset<br />
Extended Starter Capabilities<br />
■ Ground fault detection (with<br />
accessory)<br />
■ Fault log<br />
■ Overcurrent warning (adjustable)<br />
■ Undercurrent warning (adjustable)<br />
■ Emergency stop detection<br />
IT. Starters with QSNAPs<br />
Table 76. <strong>IEC</strong> SNAP Connectivity<br />
<strong>IEC</strong> E101, E501<br />
Frame Size Continuous<br />
Ampacity<br />
Rating<br />
45 mm B 18 Amp<br />
25 Amp<br />
32 Amp<br />
54 mm C 40 Amp<br />
50 Amp<br />
76 mm D 65 Amp<br />
85 Amp<br />
100 Amp<br />
105 mm E 125 Amp<br />
160 Amp<br />
200 Amp<br />
140 mm F 250 Amp<br />
315 Amp<br />
420 Amp<br />
Table 77. NEMA SNAP Connectivity<br />
NEMA N101, N501<br />
Size<br />
Continuous Ampacity<br />
Rating<br />
00 9<br />
0 18<br />
1 27<br />
2 45<br />
3 90<br />
4 135<br />
5 270<br />
Table 78. S751/S752 SNAP Connectivity<br />
S751/S752 Soft Start<br />
54 mm All Sizes<br />
Application Description<br />
A typical application for the QSNAP<br />
will contain many QSNAPs and many<br />
I/O products all connected to a single<br />
network adapter. With this architecture,<br />
an entire panel can be represented<br />
by a single network adapter.<br />
Figure 71. Typical QSNAP Application<br />
CA05001001E<br />
For more information visit: www.eaton.com
54<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Starter Network Adapters (SNAP) (D77B Series) — QCPort SNAP<br />
May 2007<br />
Standards and Certifications<br />
Approvals<br />
Table 79. Approvals/Certifications<br />
Description<br />
Specification<br />
Electrical/EMC<br />
ESD Immunity<br />
± 8 kV air, ± 4 kV contact<br />
(<strong>IEC</strong> 61000-4-2)<br />
Radiated Immunity<br />
(<strong>IEC</strong> 61000-4-3)<br />
Fast Transient<br />
(<strong>IEC</strong> 61000-4-4)<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
RF Conducted<br />
(<strong>IEC</strong> 61000-4-6)<br />
Magnetic Field<br />
(<strong>IEC</strong> 61000-4-8)<br />
Voltage Dips<br />
(<strong>IEC</strong> 61000-4-11)<br />
Other Approvals<br />
Ingress Protection Code<br />
(<strong>IEC</strong> 60947-1)<br />
Radiated and Conducted<br />
Emissions<br />
Technical Data and Specifications<br />
Table 80. Environmental Ratings<br />
10V/m 80 – 1,000 MHz, 80% amplitude<br />
modulation @ 1 kHz<br />
± 2 kV supply and control, ± 1 kV<br />
communications<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
10V, .15 – 80 MHz<br />
30A/m, 50 Hz<br />
30% dip @ 10 mS, 60% dip @ 100 mS,<br />
>95% interrupt @ 5 mS<br />
IP20<br />
EN 5011 Class A<br />
Agency Certifications UL 508, CUL (CSA C22.2 No. 14),<br />
CE (Low Voltage Directive),<br />
ODVA Conformance Tested<br />
Description<br />
Transportation/Storage<br />
Temperature<br />
Humidity<br />
Operating<br />
Temperature<br />
Humidity<br />
Altitude<br />
Power Draw<br />
Shock (<strong>IEC</strong> 68-2-27)<br />
Vibration (<strong>IEC</strong> 68-2-6)<br />
Specifications<br />
-58° to 176°F (-50° to 80°C)<br />
5 – 95% non-condensing<br />
-13° to 149°F (-25° to 65°C)<br />
5 – 95% non-condensing<br />
Above 2000 meters (6600 feet) consult factory<br />
90 mA Steady State<br />
15G any direction for 11 mS<br />
5 – 150 Hz, 5G, .7 mm max. peak-to-peak<br />
Dimensions<br />
2.4<br />
(62)<br />
Figure 72. QSNAP Approximate Dimensions in Inches (mm)<br />
Product Selection<br />
Table 81. Product Selection<br />
Description<br />
Front<br />
1.0<br />
(26)<br />
Side<br />
1.2<br />
(32)<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
QSNAP Kit for FVNR Starters D77B-QSNAP-X1 301.00<br />
QSNAP Kit for FVR Starters D77B-QSNAP-X2 333.00<br />
QSNAP Kit for FVNR Starters with HOA D77B-QSNAP-X3 350.00<br />
QSNAP Kit for FVR Starters with HOA D77B-QSNAP-X4 350.00<br />
QSNAP Adapter for Size 5 and<br />
D77B-140A 47.25<br />
Size F Frame Starters<br />
SNAP Auxiliary Connector D77B-AC1 42.00<br />
Note: For D64 zero sequence CTs, refer to Tab 49 in Publication No.<br />
CA08102001E.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — DeviceNet Adapter<br />
55<br />
Cat. No. D77D-DNA<br />
Product Description<br />
The Cutler-Hammer ® Intelligent Technologies<br />
(IT.) DeviceNet Adapter<br />
(D77D-DNA) from Eaton’s electrical<br />
business has greatly increased the<br />
functionality of IT. communicating<br />
products, allowing monitoring and<br />
control for IT. I/O and IT. motor control<br />
devices. The adapter concentrates all<br />
data from these devices into a single<br />
DeviceNet node.<br />
To simplify the configuration of the<br />
D77D-DNA, a simple auto-configure<br />
button press sets the system up for<br />
default operation. This automatically<br />
configures the DeviceNet I/O assemblies<br />
to the system devices. The data<br />
from these devices is assembled into a<br />
single input and output message.<br />
Application Description<br />
In a typical DeviceNet Adapter application,<br />
the D77D-DNA connects directly<br />
to DeviceNet, and resides in a system<br />
with IT. I/O and other communicating<br />
motor controls. The data from these IT.<br />
devices is assembled into a single<br />
input and output message before<br />
being presented to DeviceNet.<br />
Features, Functions and Benefits<br />
■ Communication to DeviceNet<br />
consuming one DeviceNet MAC ID<br />
■ Provides for control of all IT. communicating<br />
devices connected to<br />
the gateway<br />
■ Manually set to MAC ID and baud<br />
rate; configuration using a software<br />
application is not required for normal<br />
operation<br />
■ Single button press auto configures<br />
the gateway, setting up the system<br />
for default operation<br />
■ Advanced configuration using<br />
CH Studio<br />
■ Provides for backplane and interconnect<br />
cable connections to I/O<br />
modules and motor control<br />
products<br />
Standards and Certifications<br />
Approvals<br />
■ Provides one I/O DeviceNet message<br />
representing all connected devices<br />
■ Two independent ports for Plugand-Play<br />
connection to I/O<br />
■ Powered from backplane<br />
■ Isolated from DeviceNet<br />
■ Status LEDs for DeviceNet and<br />
module health<br />
■ Provides for configuration of I/O<br />
devices over DeviceNet<br />
■ Small package size<br />
■ DIN rail mountable<br />
Table 82. Approvals/Certifications<br />
Description<br />
Specification<br />
Electrical/EMC<br />
ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />
Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />
Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />
Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />
Other Approvals<br />
Ingress Protection Code<br />
IP20<br />
Radiated and Conducted Emissions EN 5011 Class A<br />
Agency Certifications<br />
UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />
ODVA Conformance Tested<br />
CA05001001E<br />
For more information visit: www.eaton.com
56<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — DeviceNet Adapter<br />
May 2007<br />
Technical Data and<br />
Specifications<br />
Dimensions<br />
Table 83. DeviceNet Specifications<br />
Description<br />
Specification<br />
DeviceNet<br />
Connections<br />
Maximum<br />
DeviceNet I/O<br />
Size<br />
DeviceNet<br />
Baud Rate<br />
QCPort Channels<br />
Group 2,<br />
Polling, Bit Strobe,<br />
Explicit, No UCMM<br />
128 Bytes Input<br />
128 Bytes Output<br />
125K, 250K, 500K<br />
2 Independent<br />
Channels<br />
3.5<br />
(90)<br />
Table 84. Environmental Ratings<br />
Description<br />
Transportation/Storage<br />
Temperature<br />
Humidity<br />
Operating<br />
Temperature<br />
Humidity<br />
Altitude<br />
Shock<br />
(<strong>IEC</strong> 68-2-27)<br />
Vibration<br />
(<strong>IEC</strong> 68-2-6)<br />
Pollution Degree 2<br />
Specification<br />
-58° – 176°F (-50° – 80°C)<br />
5 – 95% non-condensing<br />
-13° – 131°F (-25° – 55°C)<br />
5 – 95% non-condensing<br />
Above 6,600 ft. (2,000m)<br />
consult factory<br />
15G any direction for<br />
11 mS<br />
5 – 150 Hz, 5G .7 mm<br />
maximum peak-to-peak<br />
Figure 73. D77D-DNA — Approximate Dimensions in Inches (mm)<br />
2<br />
(50.8)<br />
Module<br />
Module<br />
Module<br />
.9<br />
(22.5)<br />
2 (50.8)<br />
Module<br />
Module<br />
2<br />
(50.8)<br />
2.7<br />
(68)<br />
Product Selection<br />
Table 85. DeviceNet Adapter Product<br />
Selection<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
DeviceNet Adapter D77D-DNA 406.<br />
2 (50.8)<br />
Figure 74. D77D-DNA Module Ventilation —<br />
Approximate Dimensions in Inches (mm)<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — Modbus Adapter<br />
57<br />
Cat. No. D77D-EMA<br />
Product Description<br />
The Cutler-Hammer ® Intelligent Technologies<br />
(IT). Ethernet Modbus<br />
Adapter (D77D-EMA) from Eaton’s<br />
electrical business has greatly<br />
increased the functionality of Cutler-<br />
Hammer IT. communicating products,<br />
allowing monitoring and control for IT.<br />
I/O and IT. motor control devices. The<br />
adapter concentrates all data from<br />
these devices into a single Modbus<br />
node.<br />
The Modbus Adapter supports not<br />
only Modbus TCP but also Modbus<br />
serial (ASCII and RTU) as a slave<br />
device. This combination of the two<br />
physical layers provides for ultimate<br />
functionality when connecting to a<br />
Modbus system. A unique attribute of<br />
the D77D-EMA is that it supports Modbus<br />
serial Pass-Through. In this mode<br />
a customer can connect Modbus serial<br />
devices to one of the channels and<br />
monitor and control them over<br />
Modbus TCP.<br />
To simplify the configuration of the<br />
D77D-EMA, a simple auto-configure<br />
button press sets the system up for<br />
default operation. This automatically<br />
configures the Modbus registers to the<br />
I/O system devices.<br />
Application Description<br />
In a typical Modbus Adapter application,<br />
the D77D-EMA connects directly<br />
to Modbus, and resides in a system<br />
with IT. I/O and other communicating<br />
motor controls. The data from these<br />
IT. devices is assembled into input and<br />
output registers before being presented<br />
to Modbus.<br />
Features, Functions and Benefits<br />
■ Communication to Modbus<br />
consuming one address<br />
■ Supports Boot P and static IP<br />
addressing<br />
■ 10/100 BaseT Connection<br />
■ RS-485 Modbus slave serial<br />
connection<br />
■ Supports Serial Modbus Pass-<br />
Through over Modbus TCP<br />
■ Provides for control of all IT. communicating<br />
devices connected to<br />
the gateway<br />
■ Manually set to address and baud<br />
rate for serial Modbus; configuration<br />
using a software application is<br />
not required for normal operation<br />
■ Single button press auto configures<br />
the gateway, setting up the system<br />
for default operation<br />
Standards and Certifications<br />
Approvals<br />
Technical Data and Specifications<br />
Table 87. Environmental Ratings<br />
Description Specification<br />
Transportation/Storage<br />
Temperature -58° – 176°F (-50° – 80°C)<br />
Humidity 5 – 95% non-condensing<br />
Operating<br />
Temperature -13° –149 °F (-25° – 65°C)<br />
Humidity 5 – 95% non-condensing<br />
Altitude<br />
Above 6,600 ft. (2,000m)<br />
consult factory<br />
■ Advanced configuration using CH<br />
Studio<br />
■ Provides for backplane and interconnect<br />
cable connections to I/O<br />
modules and motor control<br />
products<br />
■ Two independent ports for Plugand-Play<br />
connection to I/O<br />
■ Powered from backplane<br />
■ Isolated from Modbus<br />
■ Status LEDs for Modbus and<br />
module health<br />
■ Provides for configuration of I/O<br />
devices over Modbus TCP<br />
■ Small package size<br />
■ DIN rail mountable<br />
Table 86. Approvals/Certifications<br />
Description<br />
Specification<br />
Electrical/EMC<br />
ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />
Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />
Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />
Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />
Other Approvals<br />
Ingress Protection Code<br />
IP20<br />
Radiated and Conducted Emissions EN 5011 Class A<br />
Agency Certifications<br />
UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />
Modbus Conformance Tested<br />
Shock<br />
(<strong>IEC</strong> 68-2-27)<br />
Vibration<br />
(<strong>IEC</strong> 68-2-6)<br />
Pollution Degree 2<br />
15G any direction for<br />
11 mS<br />
5 – 150 Hz, 5G .7 mm<br />
maximum peak-to-peak<br />
Table 88. Modbus Specifications<br />
Description Specification<br />
Connections<br />
I/O Size<br />
Baud<br />
Addressing<br />
Channels<br />
10/100 BaseT<br />
RS-485<br />
1024 Registers Input<br />
1024 Registers Output<br />
Ethernet 10 Megabit<br />
Serial 1200 to 115.2K baud<br />
Ethernet – Boot P or Static IP<br />
Serial – DIP Switch 1 – 255<br />
2 Independent<br />
Channels<br />
CA05001001E<br />
For more information visit: www.eaton.com
58<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — Modbus Adapter<br />
May 2007<br />
Dimensions<br />
3.5<br />
(90)<br />
.9<br />
(22.5)<br />
2.7<br />
(68)<br />
Figure 75. D77D-EMA — Approximate Dimensions in Inches (mm)<br />
2<br />
(50.8)<br />
Module<br />
Module<br />
Module<br />
2 (50.8)<br />
Module<br />
Module<br />
2<br />
(50.8)<br />
Product Selection<br />
Table 89. Modbus Adapter Product Selection<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
Modbus Adapter D77D-EMA 499.<br />
2 (50.8)<br />
Figure 76. D77D-EMA Module Ventilation —<br />
Approximate Dimensions in Inches (mm)<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — EtherNet/IP Adapter<br />
59<br />
Features, Functions and Benefits<br />
■ Communication to EtherNet/IP<br />
consuming one address<br />
■ Supports Boot P, DHCP and static<br />
IP addressing<br />
■ 10/100 BaseT Connection<br />
■ Provides for control of all IT. communicating<br />
devices connected to<br />
the network adapter<br />
■ Single button press auto configures<br />
the gateway, setting up the system<br />
for default operation<br />
■ Advanced configuration using<br />
CH Studio<br />
■ Provides for backplane and interconnect<br />
cable connections to I/O<br />
modules and motor control<br />
products<br />
■ Two independent ports for Plugand-Play<br />
connection to I/O<br />
■ Powered from backplane<br />
■ Isolated from EtherNet/IP<br />
■ Status LEDs for EtherNet/IP and<br />
module health<br />
■ Provides for configuration of I/O<br />
devices over EtherNet/IP<br />
■ Small package size<br />
■ DIN rail mountable<br />
Cat. No. D77D-EIP<br />
Product Description<br />
The Cutler-Hammer ® Intelligent Technologies<br />
(IT.) EtherNet/IP (D77D-EIP)<br />
from Eaton’s electrical business has<br />
greatly increased the functionality of<br />
Cutler-Hammer IT. communicating<br />
products, allowing monitoring and<br />
control for IT. I/O and IT. motor control<br />
devices. The adapter concentrates all<br />
data from these devices into a single<br />
EtherNet/IP node.<br />
The EtherNet/IP Adapter is a slave<br />
device on EtherNet/IP.<br />
To simplify the configuration of the<br />
D77D-EIP, a simple auto-configure<br />
button press sets the system up for<br />
default operation. This automatically<br />
configures the EtherNet/IP assemblies<br />
to the I/O system devices.<br />
Application Description<br />
In a typical EtherNet/IP Adapter application,<br />
the D77D-EIP connects directly<br />
to EtherNet/IP, and resides in a system<br />
with IT. I/O and other communicating<br />
motor controls. The data from these<br />
IT. devices is assembled into input and<br />
output assemblies before being presented<br />
to EtherNet/IP.<br />
Standards and Certifications<br />
Approvals<br />
Table 90. Approvals/Certifications<br />
Description<br />
Specification<br />
Electrical/EMC<br />
ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />
Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />
Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />
Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />
Other Approvals<br />
Ingress Protection Code<br />
IP20<br />
Radiated and Conducted Emissions EN 5011 Class A<br />
Agency Certifications<br />
UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />
Modbus Conformance Tested<br />
Technical Data and Specifications<br />
Table 91. Environmental Ratings<br />
Description Specification<br />
Transportation/Storage<br />
Temperature -58° – 176°F (-50° – 80°C)<br />
Humidity 5 – 95% non-condensing<br />
Operating<br />
Temperature -13° –149 °F (-25° – 65°C)<br />
Humidity 5 – 95% non-condensing<br />
Altitude<br />
Above 6,600 ft. (2,000m)<br />
consult factory<br />
Shock<br />
(<strong>IEC</strong> 68-2-27)<br />
Vibration<br />
(<strong>IEC</strong> 68-2-6)<br />
Pollution Degree 2<br />
15G any direction for<br />
11 mS<br />
5 – 150 Hz, 5G .7 mm<br />
maximum peak-to-peak<br />
Table 92. EtherNet/IP Specifications<br />
Description Specification<br />
Connections<br />
I/O Size<br />
Baud<br />
Addressing<br />
Channels<br />
10/100 BaseT<br />
504 bytes Input<br />
504 bytes Output<br />
Ethernet 10/100 Megabit<br />
Ethernet – Boot P, Static IP<br />
or DHCP<br />
2 Independent<br />
Channels<br />
CA05001001E<br />
For more information visit: www.eaton.com
60<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — EtherNet/IP Adapter<br />
May 2007<br />
Dimensions<br />
3.5<br />
(90)<br />
.9<br />
(22.5)<br />
2.7<br />
(68)<br />
Figure 77. D77D-EIP — Approximate Dimensions in Inches (mm)<br />
2<br />
(50.8)<br />
Module<br />
Module<br />
Module<br />
2 (50.8)<br />
Module<br />
Module<br />
2<br />
(50.8)<br />
Product Selection<br />
Table 93. EtherNet/IP Adapter Product<br />
Selection<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
Modbus Adapter D77D-EIP 510.<br />
2 (50.8)<br />
Figure 78. D77D-EIP Module Ventilation —<br />
Approximate Dimensions in Inches (mm)<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — PROFIBUS Adapter<br />
61<br />
Features, Functions and Benefits<br />
Cat. No. D77D-PNA<br />
■ Communication to PROFIBUS<br />
consuming one address<br />
■ Supports hardware addressing<br />
■ DB9 Connection<br />
■ Modbus slave connections on<br />
motherboard<br />
■ Provides for control of all IT. communicating<br />
devices connected to<br />
the network adapter<br />
■ PROFIBUS supports autobaud<br />
■ Single button press auto configures<br />
the gateway, setting up the system<br />
for default operation<br />
■ Advanced configuration using<br />
CH Studio<br />
■ Provides for backplane and interconnect<br />
cable connections to I/O<br />
modules and motor control<br />
products<br />
■ Two independent ports for Plugand-Play<br />
connection to I/O<br />
■ Powered from backplane<br />
■ Isolated from PROFIBUS<br />
■ Status LEDs for module health<br />
■ Provides for configuration of I/O<br />
devices over Modbus TCP<br />
■ Small package size<br />
■ DIN rail mountable<br />
Product Description<br />
The Cutler-Hammer ® Intelligent Technologies<br />
(IT.) PROFIBUS Adapter<br />
(D77D-PNA) from Eaton’s electrical<br />
business has greatly increased the<br />
functionality of Cutler-Hammer IT.<br />
communicating products, allowing<br />
monitoring and control for IT. I/O and<br />
IT. motor control devices. The adapter<br />
concentrates all data from these<br />
devices into a single node.<br />
The PROFIBUS Adapter supports not<br />
only PROFIBUS but also Modbus<br />
(ASCII and RTU) as a slave device. This<br />
combination of the two physical layers<br />
provides for ultimate functionality<br />
when connecting to a control system.<br />
This unique feature of the D77D-PNA<br />
provides for deterministic control<br />
using PROFIBUS along with the flexibility<br />
to monitor and configure I/O<br />
devices over Modbus. The Modbus<br />
connection is a read-only connection<br />
not allowing control of I/O devices<br />
ensuring a single point of control.<br />
To simplify the configuration of the<br />
D77D-PNA, a simple auto-configure<br />
button press sets the system up for<br />
default operation. This automatically<br />
configures the telegrams to the system<br />
devices.<br />
Application Description<br />
In a typical PROFIBUS Adapter application,<br />
the D77D-PNA connects directly<br />
to PROFIBUS, and resides in a system<br />
with IT. I/O and other communicating<br />
motor controls. The data from these<br />
IT. devices is assembled into input<br />
and output telegrams before being<br />
presented.<br />
Standards and Certifications<br />
Approvals<br />
Table 94. Approvals/Certifications<br />
Description<br />
Specification<br />
Electrical/EMC<br />
ESD Immunity (<strong>IEC</strong> 61000-4-2) ± 8 kV air, ± 4 kV contact<br />
Radiated Immunity (<strong>IEC</strong> 61000-4-3) 10V/m 80 – 1,000 MHz, 80% amplitude modulation @ 1 kHz<br />
Fast Transient (<strong>IEC</strong> 61000-4-4) ± 2 kV supply and control, ± 1 kV communications<br />
Surge (<strong>IEC</strong> 61000-4-5)<br />
± 1 kV line-to-ground, ± 2 kV line-to-line<br />
RF Conducted (<strong>IEC</strong> 61000-4-6) 10V, .15 – 80 MHz<br />
Magnetic Field (<strong>IEC</strong> 61000-4-8) 30A/m, 50 Hz<br />
Other Approvals<br />
Ingress Protection Code<br />
IP20<br />
Radiated and Conducted Emissions EN 5011 Class A<br />
Agency Certifications<br />
UL 508, CUL (CSA C22.2 No. 14), CE (Low Voltage Directive),<br />
Modbus Conformance Tested<br />
Technical Data and Specifications<br />
Table 95. Environmental Ratings<br />
Description Specification<br />
Transportation/Storage<br />
Temperature -58° – 176°F (-50° – 80°C)<br />
Humidity 5 – 95% non-condensing<br />
Operating<br />
Temperature -13° –149 °F (-25° – 65°C)<br />
Humidity 5 – 95% non-condensing<br />
Altitude<br />
Above 6,600 ft. (2,000m)<br />
consult factory<br />
Shock<br />
(<strong>IEC</strong> 68-2-27)<br />
Vibration<br />
(<strong>IEC</strong> 68-2-6)<br />
Pollution Degree 2<br />
15G any direction for<br />
11 mS<br />
5 – 150 Hz, 5G .7 mm<br />
maximum peak-to-peak<br />
Table 96. PROFIBUS Specifications<br />
Description Specification<br />
Connection DB9<br />
I/O Size<br />
244 Bytes Input<br />
176 Bytes Output<br />
Baud<br />
Up to 12 Megabit<br />
Addressing DIP Switch 1 – 255<br />
Channels 2 Independent<br />
Channels<br />
CHA Current 170 mA<br />
Draw<br />
CHB Current 10 mA<br />
Draw<br />
CA05001001E<br />
For more information visit: www.eaton.com
62<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
Communication Adapters (D77D Series) — PROFIBUS Adapter<br />
May 2007<br />
Dimensions<br />
3.5<br />
(90)<br />
1.8<br />
(45)<br />
2.7<br />
(68)<br />
Figure 79. D77D-PNA — Approximate Dimensions in Inches (mm)<br />
2<br />
(50.8)<br />
Module<br />
Module<br />
Module<br />
2 (50.8)<br />
Module<br />
Module<br />
2<br />
(50.8)<br />
Product Selection<br />
Table 97. PROFIBUS Adapter Product<br />
Selection<br />
Description<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
PROFIBUS Adapter D77D-PNA 580.<br />
2 (50.8)<br />
Figure 80. D77D-PNA Module Ventilation —<br />
Approximate Dimensions in Inches (mm)<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
For more information visit: www.eaton.com<br />
CA05001001E
May 2007<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
CH Studio Component Manager Software 45<br />
63<br />
CH Studio<br />
Product Description<br />
CH Studio Component Manager<br />
Software<br />
CH Studio from Eaton’s electrical business<br />
is an integrated software development<br />
environment that supports<br />
the configuration and monitoring of<br />
control products and systems. The<br />
application simplifies the monitoring<br />
and configuration of entire networks,<br />
as well as the enhanced features of<br />
individual IT. communicating devices<br />
within those networks.<br />
CH Studio takes advantage of the<br />
Windows graphical interface to<br />
present a suite of tools that is easy to<br />
learn and efficient to use, while meeting<br />
the requirements for developing<br />
complex network configurations.<br />
Configure Eaton’s Cutler-Hammer<br />
Control Devices<br />
Component Manager provides for the<br />
configuration and monitoring of the<br />
following Cutler-Hammer ® products:<br />
■ IT. Motor Control Center (MCC)<br />
■ IT. Electro-Mechanical Motor Starters<br />
connected by a Starter Network<br />
Adapter Product (SNAP) or Cover<br />
Control<br />
■ IT. S751/S752 Soft Starters connected<br />
by a SNAP, Cover Control or<br />
a Network Adapter<br />
■ IT. I/O modules<br />
■ IT. S811 Soft Starter connected by<br />
network Adapter<br />
■ IT. D77D-DNA DeviceNet network<br />
Adapter<br />
■ IT. D77D-EMA Modbus/TCP network<br />
Adapter<br />
■ IT. D77D-EIP EtherNet/IP network<br />
Adapter<br />
■ IT. D77D-PNA PROFIBUS network<br />
Adapter<br />
■ Cutler-Hammer legacy DeviceNet<br />
products<br />
Configure Other DeviceNet <strong>Products</strong><br />
CH Studio provides the capacity to<br />
configure and monitor all DeviceNet<br />
products that are supported by a published<br />
EDS file, regardless of vendor.<br />
The DeviceNet management package<br />
includes prepackaged support of over<br />
4000 different devices, and the capability<br />
to include new EDS files, as<br />
needed.<br />
Application Description<br />
The CH Studio Software runs on any<br />
personal computer hosting one of the<br />
following supported Windows operating<br />
systems:<br />
■ MS Windows XP<br />
■ MS Windows 2000<br />
A typical automation system is<br />
comprised of a programmable logic<br />
controller acting as a master, and<br />
numerous slave devices such as network<br />
adapters, motor starters, or I/O<br />
modules. The devices are networked<br />
via an industrial fieldbus such as<br />
DeviceNet or Modbus/TCP.<br />
A personal computer hosting CH<br />
Studio may be connected to an industrial<br />
network using a supported interface<br />
card or common Ethernet port<br />
(a variety of network protocols, such<br />
as Modbus/TCP, utilize Ethernet for a<br />
physical layer). CH Studio can then be<br />
used to configure and commission the<br />
automation products and network.<br />
Industry Standard Fieldbus (DeviceNet/EtherNet)<br />
USB/<br />
DeviceNet<br />
Adapter<br />
D77SX-A-X<br />
Network Adapter<br />
D77D-DNA<br />
(DeviceNet)<br />
D77D-EMA<br />
(Modbus/TCP)<br />
Network Adapter<br />
D77D-DNA<br />
(DeviceNet)<br />
D77D-EMA<br />
(Modbus/TCP)<br />
Starter<br />
Interface<br />
D77D-DSNAP<br />
IT. EM<br />
Starter<br />
IT. S811<br />
Soft Starter<br />
IT. EM<br />
Starter<br />
Screen Shot<br />
CH Studio components include<br />
Explorer, Property, Output, Toolbox,<br />
Message Editor, Property Pages, and<br />
Device Selector windows and dialog<br />
boxes.<br />
PC Hosting<br />
Component<br />
Manager<br />
Figure 81. Network Diagram<br />
Cover Control<br />
IT. MCC (Typical)<br />
CA05001001E<br />
For more information visit: www.eaton.com
64<br />
<strong>PLC</strong>, I/O & <strong>Communications</strong> <strong>Products</strong><br />
IT. Connect<br />
CH Studio Component Manager Software<br />
May 2007<br />
Features, Functions and<br />
Benefits<br />
Studio provides powerful features:<br />
■ Fast discovery of devices on<br />
DeviceNet, Modbus/TCP and<br />
Ethernet/IP networks.<br />
■ “Snapshot” storage of an entire networks<br />
worth of device parameters<br />
with just one mouse-click.<br />
■ Rapid configuration of IT. family<br />
products via “plug-in” support components<br />
that are regularly updated<br />
via the Internet.<br />
■ Online and offline operation with<br />
flexible synchronization options.<br />
■ Custom configuration dialogs for<br />
point and click ease of configuration,<br />
support for any DeviceNet<br />
product with or without EDS files.<br />
■ Extensive report generation to assist<br />
<strong>PLC</strong> or DCS programmers.<br />
■ OPC server for industry standard<br />
communications with third party<br />
products such as HMI, data<br />
acquisition and control applications.<br />
■ Built-in 4800+ device EDS file<br />
database.<br />
■ OPC server-to-control and monitor<br />
QCPort device over OPC.<br />
■ Tag export feature to import tag<br />
data to the controller.<br />
■ Live I/O to view actual status of the<br />
QCPort I/O when online.<br />
Technical Data and<br />
Specifications<br />
■ Processor: 230 MHz Pentium class<br />
minimum; 300+ MHz recommended.<br />
■ Memory (RAM): 64 MB Minimum<br />
(may limit performance); 128 MB+<br />
recommended.<br />
■ Hard Drive Space: 120 MB - CHStudio<br />
additional 70 meg for online<br />
documentation in .PDF format.<br />
■ Super VGA 800x600 or higher resolution<br />
video adapter and monitor.<br />
■ CDROM or DVD Drive (required for<br />
installation).<br />
■ Keyboard and Microsoft mouse or<br />
compatible pointing device.<br />
■ Industrial network adapter. Studio<br />
makes use of the Ethernet port that<br />
comes as standard equipment on<br />
most PCs for industrial protocols<br />
such as MODBUS/TCP. For<br />
DeviceNet networks a USB/<br />
DeviceNet converter is available, or<br />
you may use one of the popular SS<br />
Technologies Devicenet interfaces in<br />
the 5136 series (ISA, PCI, PCMCIA<br />
supported).<br />
USB DeviceNet Adapter<br />
The D77SX-A-X USB converter is a<br />
cost-effective interface for DeviceNet<br />
networks. Specifically designed for<br />
use with CH Studio, the USB converter<br />
provides a high performance<br />
DeviceNet interface with Plug and<br />
Play ease of installation. The D77SX-<br />
A-X comes in kit form including USB<br />
and 6-foot DeviceNet to mini cables.<br />
Drivers for the converter are built into<br />
CH Studio.<br />
Product Selection<br />
The following table lists the Catalog<br />
Numbers for available CH Studio<br />
software packages:<br />
Table 98. CH Studio Product Selection<br />
Description<br />
CH Studio Component<br />
Manager V2.1<br />
CH Studio Component<br />
Manager V2.1 w/USB<br />
interface<br />
USB/DeviceNet<br />
Interface (Alone)<br />
CH Studio Component<br />
Manager 2.1 and OPC<br />
Server<br />
CH Studio Component<br />
Manager 2.1 OPC<br />
Server<br />
Catalog<br />
Number<br />
Price<br />
U.S. $<br />
D77SC-X-D 1,040.<br />
D77SC-A-D 1,325.<br />
D77SX-A-X 555.<br />
D77SC-X-P 1,315.<br />
D77SC-A-P 1,575.<br />
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1<br />
Eaton Corporation<br />
Electrical Group<br />
1000 Cherrington Parkway<br />
Moon Township, PA 15108<br />
United States<br />
877-ETN CARE (877-386-2273)<br />
Eaton.com<br />
© 2007 Eaton Corporation<br />
All Rights Reserved<br />
Printed in USA<br />
Publication No. CA05001001E/CPG<br />
May 2007