1998 S/N 21329 - Walker Mowers
1998 S/N 21329 - Walker Mowers
1998 S/N 21329 - Walker Mowers
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Maintenance Instructions<br />
CLEANING<br />
Turbine Precleaner<br />
The turbine precleaner is mounted on a remote air<br />
intake tube connected to the Donaldson air cleaner.<br />
A spinning fan driven by the intake airflow separates<br />
dust from the air, giving the initial stage of air cleaning.<br />
Dust particles are exhausted through a single<br />
small vent in the side of the housing. Since no dust<br />
is trapped, the precleaner operates without cleaning.<br />
The only maintenance required is to check the<br />
operation of the internal fan every 100 hours. Verify<br />
operation:<br />
1. Look into the exhaust vent while shining a light<br />
into the intake.<br />
Cover<br />
Vacuator<br />
Valve<br />
Cover Latch<br />
Canister<br />
Radialseal<br />
Filter Element<br />
2. Start the engine and watch the fan begin to spin<br />
as the throttle is advanced.<br />
If the fan is not spinning, service or replace the precleaner<br />
as required.<br />
Donaldson Radialseal Air Cleaner (Primary)<br />
A remote mounted Donaldson Radialseal air<br />
cleaner provides the primary air filtering function<br />
(ahead of the standard Kohler engine air cleaner).<br />
The paper filter element slides over an outlet tube inside<br />
the air cleaner canister with radial sealing action,<br />
eliminating the possibility of dust leaks due to<br />
improper filter installation. Intake design, internal<br />
baffling, and a Vacuator valve provide dust separation<br />
and automatic precleaning action. Daily or<br />
frequent servicing of the air cleaner is not required.<br />
Use the air restriction gauge on the air cleaner outlet<br />
to indicate when the air filter needs servicing -- a red<br />
flag will appear when the filter is overly restricting<br />
airflow into the engine.<br />
IMPORTANT: Use only Donaldson air filter elements<br />
for replacement (Donaldson P822686 or<br />
<strong>Walker</strong> 5090-1). Aftermarket filters may not seal<br />
properly or filter efficiently.<br />
Air Cleaner Components<br />
(shown with cover being removed)<br />
IMPORTANT: The Donaldson air cleaner uses a dry<br />
paper-type air filter element. NEVER apply oil to the<br />
paper element.<br />
Push Button to Reset<br />
Indicator After Service<br />
Air Restriction<br />
Gauge<br />
Air Restriction Gauge Location<br />
Clean and inspect the paper element after every<br />
100 hours of service and replace the element yearly<br />
or after six (6) cleanings (or when dirty or damaged).<br />
More frequent cleaning may be required<br />
when operating in extremely dusty conditions as indicated<br />
by the air restriction gauge. Service the air<br />
cleaner as follows:<br />
54