Features <strong>and</strong><br />
Applications<br />
Definite Purpose<br />
Contactors<br />
Definite Purpose Contactors<br />
St<strong>and</strong>ard Line<br />
• 20-40 FLA 60 Hz 600VAC Max<br />
• For Contactors Thru 210 FLA, see<br />
Centurion 2000 Premium line.<br />
Single Pole<br />
• Compact Size<br />
• Straight Thru Wiring<br />
• Long Life<br />
• Non Tracking Contact Board<br />
• Interchangeable Mounting Base<br />
• Quick Connect Terminals<br />
• Weld Resistant Contacts<br />
• UL File E14900<br />
• CSA File LR6535 <strong>and</strong> 42531<br />
• TUV/VDE Approved – Contact Factory<br />
Application<br />
<strong>Furnas</strong> compact definite purpose<br />
contactors are designed for controlling<br />
air conditioning, heating, welding, data<br />
processing <strong>and</strong> refrigeration equipment.<br />
They provide reliable full voltage control<br />
of compressor motors <strong>and</strong> electric<br />
heating loads. When used with an<br />
appropriate pilot device they can provide<br />
either low voltage protection or low<br />
voltage release. These controls have<br />
been designed with a low drop out<br />
voltage making them ideal for air<br />
conditioning, heating <strong>and</strong> refrigeration<br />
applications.<br />
Construction<br />
Compact – Space saving dimensions<br />
allow for smaller panels <strong>and</strong> more wiring<br />
room.<br />
Straight Thru Wiring – Line terminals are<br />
located at the top <strong>and</strong> load terminals at<br />
the bottom. This construction eliminates<br />
looping wires around the control <strong>and</strong><br />
reduces wiring costs.<br />
Mounting – Contactors are designed for<br />
mounting on a vertical service. Side by<br />
side grouping is possible since all<br />
terminals are front accessible <strong>and</strong><br />
isolated from adjacent controls by<br />
molded barriers.<br />
Interchangeable Mounting – The<br />
combination of multiple mounting holes<br />
<strong>and</strong> slots allows these contactors to be<br />
fastened onto panels <strong>and</strong> provide<br />
interchangeable mounting with many<br />
competitive contactors.<br />
Terminals – Line <strong>and</strong> load terminals are<br />
supplied with pressure connectors. Pilot<br />
control wires attach to the line terminals<br />
by using integral auxiliary connections.<br />
2 Pole<br />
24 RSP-PRC003-EN