Section 7. Operation<br />

of the operating system or a hardware reset. The SDI-12 values of temperature<br />

and relative humidity will be -999.00 if no such information is available such<br />

as when no probe is connected to the SDI-12 port. The diagnostic mode shows<br />

two values. The first value is the flag for the fuzzy diagnostic mode (0 or 1);<br />

see Section 7.5.2, Retrieving Historical Data for more information. The second<br />

value indicates the connection status of the calibration unit, 0 shows that the<br />

unit is not connected and 1 shows that it is connected.<br />

FIGURE 7-29. Information menu<br />

7.4.8 Top Menu Option 9 (Done)<br />

Choosing option 9 from the SETUP menu brings up the DONE menu (see<br />

Figure 7-30). Here changes made can be saved before quitting (option 1) or lost<br />

before quitting (option 2). Alternatively option 0 returns to the main menu.<br />

7-35