Section 7. Operation<br />

FIGURE 7-20. View / adjust calibration menu<br />

Option 9 of the configuration menu gives the TERMINAL MODE menu (see<br />

Figure 7-21). Choose whether CRC16-CCITT checksum verification is<br />

required.<br />

NOTE<br />

When terminal mode is set to 1 all terminal commands need a<br />

CRC. For example “open 0;d2d5” a semi-colon is used to<br />

indicate start of CRC in 4 byte ASCII hex. The CRC is<br />

calculated either from the start of new line or after a [STX] up to<br />

but not including the semicolon. ETX can follow the CRC if<br />

required. The valid CRC can be read back for any command if<br />

the CRC after the semi-colon is replaced with four `?’. For<br />

example “open 0;????” the response will be<br />

[CRLF]CRC>D2D5