Section 7. Operation<br />
10. DC voltage of upper detector greater than 1.5 V. This can be caused<br />
by sun directly shining into lens or a pws fault.<br />
11. DC voltage of lower detector greater than 1.5 V. This can be caused<br />
by sun directly shining into lens or a pws fault.<br />
12. Particle processor is unable to process all particles due to limited time<br />
and buffer resources. Particles are missed and data could be<br />
inaccurate. This alarm may activate when there are 120 or more<br />
particles per second going through the volume, sustained for a period<br />
that fills all available space in the buffers.<br />
13. Particle processor lags real time by more than 5% of the user<br />
requested statistics interval.<br />
14. Particle stripper is unable to process all particles due to limited time<br />
and buffer resources. Particles are missed and data will be inaccurate.<br />
This alarm may activate if there are more than ~150 particles per<br />
second going through the volume.<br />
15. Reserved for future use. Outputs ‘0’.<br />
16. Reserved for future use. Outputs ‘0’.<br />
7.4.1.9 Message Field 25 Fault Status of the <strong>PWS100</strong><br />
This field will output the fault status of the <strong>PWS100</strong>. The value output is from<br />
0 to 4. 0 = no fault, 1 = Possible degraded performance, 2 = Degraded<br />
performance, 3 = Maintenance required, 4 = Laser fault.<br />
7.4.1.10 Message Field 30 External <strong>Sensor</strong> Temperature, RH% and Wetbulb<br />
This field will output the averaged temperature (°C), sampled relative humidity<br />
and averaged wetbulb temperature (°C) calculated over the Message_Interval<br />
defined.<br />
7.4.1.11 Message Field 31 External <strong>Sensor</strong> Maximum and Minimum Temperature<br />
This field will output the maximum and minimum temperature (°C) calculated<br />
over the Message_Interval defined.<br />
7.4.1.12 Message Field 33 External <strong>Sensor</strong> Wetness<br />
This field will output the sampled wetness (0-100%).<br />
7.4.1.13 Message Field 34 External <strong>Sensor</strong> Aux<br />
This field will output the sampled auxiliary sensor output. Such an auxiliary<br />
sensor needs to be defined.<br />
7.4.1.14 Message Field 40 Precipitation Intensity<br />
This field will output the precipitation intensity (mm / hour) calculated over the<br />
Message_Interval defined.<br />
7-11