Relay 8 Input Power Relay 7 Input Power Relay 6 Input Power Relay 5 Input Power Relay Output 8 Relay Output 7 Relay Output 6 Relay Output 5 Relays 1-4 Input Power Relay Output 4 Relay Output 3 Relay Output 2 Relay Output 1 Figure 26: Typical Relay Wiring 9.4. FLEX M ANALOG I/O MODULE Outputs: The four analog output signals are able to send voltage signals from 0 to +/-10VDC, at an 8bit resolution. These outputs are for reference voltage only, so each one can only supply 20mA of current. The outputs share a common ground reference, which is isolated from the Flex M system ground and any additional I/O card output ground. These outputs can be preconfigured at the factory for different voltage ranges (ex. 0-5VDC, or 3-6-9VDC). Inputs: The four analog input signals are able to receive voltage signals from 0 to +10VDC, at an 8bit resolution. The input impedance is 20K for these inputs. The inputs share a common ground reference, which is shared with the Flex M system ground. Flex PRO / Flex M Pre-Engineered Radio Control System Instruction Manual April 2012 Page 30 of 42
Figure 27: Analog I/O Module Detail View Analog Input Common Analog Output Common Figure 28: Typical Analog I/O Wiring Flex PRO / Flex M Pre-Engineered Radio Control System Instruction Manual April 2012 Page 31 of 42
- Page 1 and 2: Flex PRO / Flex M Pre-Engineered Ra
- Page 3 and 4: 10. RECEIVER CHANNEL CONFIGURATION
- Page 5 and 6: Your New Flex PRO/Flex M Radio Cont
- Page 7 and 8: 2. RADIO CONTROLLED SAFETY 2.1. WAR
- Page 9 and 10: 2.5. SAFETY INFORMATION AND RECOMME
- Page 11 and 12: 2.8. BATTERIES WARNING KNOW AND FOL
- Page 13 and 14: 3. GENERAL TRANSMITTER INFORMATION
- Page 15 and 16: 3.3. TYPES OF BUTTONS The buttons u
- Page 17 and 18: 4.2. INACTIVITY TIME OUT TIMER Bits
- Page 19 and 20: 6. OPERATING PROCEDURE 6.1. GENERAL
- Page 21 and 22: 7.1. MECHANICAL LAYOUTS 7.0 RECEIVE
- Page 23 and 24: 7.2. RECEIVER INSTALLATION Figure 1
- Page 25 and 26: 8. NORMAL OPERATION During the oper
- Page 27 and 28: 9. FLEX MODULE TYPES The Flex M sys
- Page 29: POWER SUPPLY MODULE OPTIONS Descrip
- Page 33 and 34: 10.1. CHANNEL DIP SWITCH SETTINGS F
- Page 35 and 36: Flex PRO / Flex M Pre-Engineered Ra
- Page 37 and 38: 11. TROUBLESHOOTING WARNING THE OPE
- Page 39 and 40: 11.3. TROUBLESHOOTING TABLE Problem
- Page 41 and 42: 11.4. ASSEMBLY AND REPLACEMENT PART
Relay 8<br />
Input Power<br />
Relay 7<br />
Input Power<br />
Relay 6<br />
Input Power<br />
Relay 5<br />
Input Power<br />
Relay Output 8<br />
Relay Output 7<br />
Relay Output 6<br />
Relay Output 5<br />
Relays 1-4<br />
Input Power<br />
Relay Output 4<br />
Relay Output 3<br />
Relay Output 2<br />
Relay Output 1<br />
Figure 26: Typical Relay Wiring<br />
9.4. FLEX M ANALOG I/O MODULE<br />
Outputs: The four analog output signals are able to send voltage signals from 0 to +/-10VDC, at an 8bit<br />
resolution. These outputs are for reference voltage only, so each one can only supply 20mA of current.<br />
The outputs share a common ground reference, which is isolated from the <strong>Flex</strong> M system ground and any<br />
additional I/O card output ground. These outputs can be preconfigured at the factory for different voltage<br />
ranges (ex. 0-5VDC, or 3-6-9VDC).<br />
Inputs: The four analog input signals are able to receive voltage signals from 0 to +10VDC, at an 8bit<br />
resolution. The input impedance is 20K for these inputs. The inputs share a common ground reference,<br />
which is shared with the <strong>Flex</strong> M system ground.<br />
<strong>Flex</strong> PRO / <strong>Flex</strong> M <strong>Pre</strong>-<strong>Engineered</strong> <strong>Radio</strong> <strong>Control</strong> System Instruction Manual<br />
April 2012<br />
Page 30 of 42