28.10.2014 Views

Cascada™ RO-Water Purification System - Pall Corporation (PLL)

Cascada™ RO-Water Purification System - Pall Corporation (PLL)

Cascada™ RO-Water Purification System - Pall Corporation (PLL)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Cascada <strong>RO</strong>-<strong>Water</strong> <strong>Purification</strong> <strong>System</strong><br />

Applications for Cascada<br />

<strong>RO</strong>-<strong>Water</strong> <strong>System</strong><br />

Type III primary-grade water from<br />

a potable tap feed<br />

<strong>Water</strong> pre-treatment prior to<br />

ultrapure water purification<br />

Routine glassware washing<br />

Hydroponics<br />

Feed water for humidifiers and<br />

autoclaves<br />

Environmental cabinets and stills<br />

Steam generators<br />

Simple reverse osmosis (<strong>RO</strong>) for laboratory-grade water<br />

98% effective removal of inorganics – <strong>RO</strong> also efficiently removes organics,<br />

microorganisms, and particles.<br />

Simple operation – User-friendly controls, large back-lit alphanumeric LCD, informative<br />

status displays, and simple maintenance routines guarantee convenience.<br />

Continuous quality monitoring – Microprocessor-controlled system with water quality<br />

display and audiovisual alarms ensures consistent and reliable operation.<br />

Maximized system efficiency – The very latest in <strong>RO</strong> technology features high<br />

flux, thin-film composite, non-cellulosic membranes for optimal performance.<br />

Fits anywhere – Compact design accomodates benchtop, under bench,<br />

or wall mounting.<br />

Space-saving storage tank – An available 35 L docking vessel reservoir cradles<br />

the Cascada unit eliminating space requirements for a second reservoir tank. Can<br />

be wall mounted.<br />

Simple sanitization.<br />

Permanent record of data – RS232 port allows for data collection and permanent<br />

record of water quality and system parameters – essential for compliance with Good<br />

Laboratory Practice (GLP) guidelines.


<strong>Purification</strong> <strong>System</strong> Flow<br />

Specifications<br />

<strong>Water</strong> Purity<br />

Inorganics – minimum<br />

Inorganics – typical<br />

Organics (MW > 100 Dalton)<br />

Total organic carbon (TOC) – typical (dependent on feed water)<br />

Bacteria<br />

Particles<br />

Flow Rates<br />

<strong>RO</strong>-water<br />

> 90% rejection<br />

Up to 98% rejection<br />

> 99% rejection<br />

< 0.1 ppm<br />

< 5 CFU/mL<br />

> 99% rejection<br />

15 L/hr.<br />

Potable water enters through a strainer and passes through<br />

the pre-treatment cartridge. The pre-treatment cartridge has<br />

been designed to protect the reverse osmosis cartridges from<br />

particulate/colloidal matter and excessive free chlorine that may<br />

be present in the incoming feed water.<br />

The water passes the sanitization port and moves through two<br />

reverse osmosis cartridges, set up in series, which split the flow<br />

into permeate and concentrate streams. The concentrate stream<br />

is passed to drain.<br />

The permeate water is passed through the:<br />

1. <strong>Water</strong> quality sensor, which measures the conductivity<br />

of the water; and<br />

2. Temperature sensor, which provides accurate<br />

temperature measurement.<br />

Finally, the purified water is delivered to a treated water reservoir.<br />

To ensure water quality is maintained at the highest levels, the<br />

unit has a built-in, automated rinse cycle. This cycle is performed<br />

each time the process is initiated and consists of a 1-minute<br />

high flow rinse across the <strong>RO</strong> cartridges to the drain.<br />

Accessories to complement the Cascada <strong>RO</strong>-water system include<br />

printer kit, boost pump, and other water storage reservoirs. Contact<br />

your local <strong>Pall</strong> office or distributor for more information.<br />

Safety Features<br />

Power fail-safe<br />

Automatic level controls<br />

Audiovisual alarm warnings<br />

Auto-restart<br />

<strong>System</strong> Monitoring<br />

Ordering Information<br />

Part Number Description Quantity<br />

PAL-CAXXX<strong>RO</strong>M2 Cascada <strong>RO</strong>-water system 1/pkg<br />

PAL-A653* Docking vessel - 35 liter 1/pkg<br />

PAL-A644 25 L reservoir 1/pkg<br />

PAL-A645 40 L reservoir 1/pkg<br />

PAL-A646 75 L reservoir 1/pkg<br />

PAL-A624** Wall mounting kit for reservoir tank with 1/pkg<br />

35 liter docking vessel<br />

PAL-A655** Wall mounting kit for Cascada unit 1/pkg<br />

PAL-A500 Pressure regulator valve (required) 1/pkg<br />

*Docking vessel or reservoir is required for proper operation of Cascada <strong>RO</strong> unit.<br />

**Optional<br />

<strong>RO</strong>-water<br />

Yes<br />

Yes<br />

Yes - selectable<br />

Yes<br />

<strong>RO</strong>-water<br />

<strong>RO</strong> permeate purity<br />

Yes - in µS/cm<br />

<strong>RO</strong> permeate temperature Yes - in °C<br />

Reservoir level<br />

Yes - in % full<br />

Consumable remaining life indicator<br />

Yes<br />

Dimensions Weight Electrical Requirements<br />

57 W x 74 H x 32 D cm 7.5 Kg Electrical input 100-240V AC,<br />

(22.4 W x 29.1 H x 12.6 D in.) (16.5 lbs.) 50-60Hz, system voltage 24V DC<br />

Please call <strong>Pall</strong> Technical Service for weights and dimensions.<br />

<strong>Pall</strong> Life Sciences<br />

600 South Wagner Road<br />

Ann Arbor, MI 48103-9019 USA<br />

800.521.1520 USA and Canada<br />

(+)800.PALL.LIFE Outside USA and Canada<br />

734.665.0651 phone<br />

734.913.6114 fax<br />

Australia – Cheltenham, VIC<br />

Tel: 03 9584 8100<br />

1800 635 082 (in Australia)<br />

Fax: 1800 228 825<br />

Austria – Wien<br />

Tel: 00 1 49 192 0<br />

Fax: 00 1 49 192 400<br />

Canada – Ontario<br />

Tel: 905-542-0330<br />

800-263-5910 (in Canada)<br />

Fax: 905-542-0331<br />

Canada – Québec<br />

Tel: 514-332-7255<br />

800-435-6268 (in Canada)<br />

Fax: 514-332-0996<br />

800-808-6268 (in Canada)<br />

China – P. R., Beijing<br />

Tel: 86-10-6780 2288<br />

Fax: 86-10-6780 2238<br />

France – St. Germain-en-Laye<br />

Tel: 01 30 61 32 32<br />

Fax: 01 30 61 58 01<br />

Lab-FR@pall.com<br />

Germany – Dreieich<br />

Tel: 06103-307 333<br />

Fax: 06103-307 399<br />

Lab-DE@pall.com<br />

India – Mumbai<br />

Tel: 91 (0) 22 67995555<br />

Fax: 91(0) 22 67995556<br />

Italy – Buccinasco<br />

Tel: +3902488870.1<br />

Fax: +39024880014<br />

Japan – Tokyo<br />

Tel: 03-6901-5800<br />

Fax: 03-5322-2134<br />

Korea – Seoul<br />

Tel: 82-2-560-8711<br />

Fax: 82-2-569-9095<br />

Malaysia – Selangor<br />

Tel: +60 3 5569 4892<br />

Fax: +60 3 5569 4896<br />

Poland – Warszawa<br />

Tel: 22 510 2100<br />

Fax: 22 510 2101<br />

Russia – Moscow<br />

Tel: 5 01 787 76 14<br />

Fax: 5 01 787 76 15<br />

Singapore<br />

Tel: 65 6 389-6500<br />

Fax: 65 6 389-6501<br />

South Africa –<br />

Johannesburg<br />

Tel: +27-11-2662300<br />

Fax: +27-11-3253243<br />

Spain – Madrid<br />

Tel: 91-657-9876<br />

Fax: 91-657-9836<br />

Sweden – Lund<br />

Tel: (0)46 158400<br />

Fax: (0)46 320781<br />

Switzerland – Basel<br />

Tel: 061-638 39 00<br />

Fax: 061-638 39 40<br />

Taiwan – Taipei<br />

Tel: 886 2 2545 5991<br />

Fax: 886 2 2545 5990<br />

Thailand – Bangkok<br />

Tel: 66 2937 1055<br />

Fax: 66 2937 1066<br />

United Kingdom –<br />

Farlington<br />

Tel: 02392 302600<br />

Fax: 02392 302601<br />

Lab-UK@europe.pall.com<br />

Visit us on the Web at www.pall.com/lab (Live help)<br />

E-mail us at LabCustomerSupport@pall.com<br />

© 2008, <strong>Pall</strong> <strong>Corporation</strong>. <strong>Pall</strong>, , and Cascada are trademarks of <strong>Pall</strong> <strong>Corporation</strong>. ® indicates a trademark registered in the<br />

USA.<br />

is a service mark of <strong>Pall</strong> <strong>Corporation</strong>.<br />

09/08, 3K, GN08.2374 PN 33373

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!