GVL Cryoengineering Dr. George V. Lecomte GmbH

GVL Cryoengineering Dr. George V. Lecomte GmbH GVL Cryoengineering Dr. George V. Lecomte GmbH

gvlcryoengineering
from gvlcryoengineering More from this publisher
02.11.2012 Views

GVL Cryoengineering Dr. George V. Lecomte GmbH Meß-, Regel- und Kryotechnik EXCERPT FROM THE PRODUCT LIST "CRYOGENIC ACCESSORIES" August 2011, Page 1 Low temperature and vacuum greases 1 GVLZ079 Apiezon "N" grease (low temperatures) 25g Tube 2 GVLZ080 Apiezon "M" grease (high vacuum) 100g Tube 3 GVLZ128 Dow Corning vacuum grease (high vacuum) 50g Tube Low temperature glue or varnish Note: Most chemicals require special shipment – please inquire 4 GVLZ056 "IMI 7031" 1 insulating varnish 100ml bottle 5 "IMI 7031" 1 insulating varnish 250ml bottle 6 "IMI 7031" 1 insulating varnish 500ml bottle 7 GVLZ076 "Stycast 2850FT", with hardener 1kg package 8 GVLZ077 "Stycast 1266", A und B 1kg package 9 GVLZ097 "Armstrong A12", epoxy with hardener 55g + 45g package Conducting varnish 10 GVLZ054 Silver-based Epoxy-coating Elekolit 336 50g-package 11 GVLZ055 Silver-based Epoxy-coating Elekolit 342 3g-package Adhesive tape 12 GVLZ059 Aluminum tape, 81µm thick, conductive, 19.1mm 16.5m 13 GVLZ060 Aluminum tape, 81µm thick, conductive, 25.4mm 16.5m 14 GVLZ057 Aluminized polyester, non conductive, 19.1mm 66m 15 GVLZ058 Aluminized polyester, non conductive, 25.4mm 66m Resistance wire (varnish insulated) 16 GVLZ001 Manganin®-wire 0.03 mm diameter 100m spool 17 Manganin®-wire 0.03 mm diameter 500m spool 18 GVLZ002 Manganin®-wire 0.05 mm diameter 100m spool 19 Manganin®-wire 0.05 mm diameter 500m spool 20 GVLZ003 Manganin®-wire 0.1 mm diameter 100m spool 21 Manganin®-wire 0.1 mm diameter 500m spool 22 GVLZ149 Manganin®-wire 0.127 mm diameter, ML insulated 100m spool 23 Manganin®-wire 0.127 mm diameter, ML insulated 500m spool 24 GVLZ004 Manganin®-wire 0.14 mm diameter 100m spool 25 Manganin®-wire 0.14 mm diameter 500m spool 26 GVLZ005 Manganin®-wire 0.2 mm diameter 100m spool 27 Manganin®-wire 0.2 mm diameter 500m spool 28 GVLZ006 Manganin®-wire 0.27 mm diameter 100m spool 29 Manganin®-wire 0.27 mm diameter 500m spool 30 GVLZ150 Manganin®-wire 0.5 mm diameter 100m spool 31 Manganin®-wire 0.5 mm diameter 500m spool 32 GVLZ007 Manganin®-wire 0.56 mm diameter 100m spool 33 Manganin®-wire 0.56 mm diameter 500m spool 34 GVLZ050 Brass-wire 0.10 mm diameter 500m spool 35 GVLZ029 Brass-wire 0.112 mm diameter 500m spool 36 GVLZ151 Constantan-wire 0.10 mm diameter 100m spool 37 Constantan-wire 0.10 mm diameter 500m spool 38 GVLZ087 Constantan-wire 0.224 mm diameter 500m spool 39 GVLZ094 NiCr80-wire 0.1 mm diameter 100m spool 40 NiCr80-wire 0.1 mm diameter 500m spool 41 GVLZ092 NiCr80-wire 0.2 mm diameter 100m spool 42 NiCr80-wire 0.2 mm diameter 500m spool 43 GVLZ095 NiCr60-wire 0.06 mm diameter 100m spool 44 GVLZ104 Phosphor-Bronze wire 0.1 mm diameter 100m spool Other diameters on request Resistance wire (uninsulated) 45 GVLZ093 Manganin®-wire 0.1 mm diameter 100m spool 46 GVLZ112 CuNi6-wire 0.4 mm diameter 100m spool 47 GVLZ146 Brass-wire 0.10 mm diameter 200m spool 48 Brass-wire 0.10 mm diameter 500m spool All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if applicable, are additional - This price list voids and replaces all earlier versions. 1 formerly known as GE-7031 Insulating Varnish GVL Cryoengineering Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733 Dr George V. Lecomte GmbH Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783 Aachener Str.89, D-52223 Stolberg (Rheinl.) www.GVL-Cryoengineering.de Geschäftsführer: Dr. G. V. Lecomte

<strong>GVL</strong> <strong>Cryoengineering</strong><br />

<strong>Dr</strong>. <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong><br />

Meß-, Regel- und Kryotechnik<br />

EXCERPT FROM THE PRODUCT LIST<br />

"CRYOGENIC ACCESSORIES"<br />

August 2011, Page 1<br />

Low temperature and vacuum greases<br />

1 <strong>GVL</strong>Z079 Apiezon "N" grease (low temperatures) 25g Tube<br />

2 <strong>GVL</strong>Z080 Apiezon "M" grease (high vacuum) 100g Tube<br />

3 <strong>GVL</strong>Z128 Dow Corning vacuum grease (high vacuum) 50g Tube<br />

Low temperature glue or varnish<br />

Note: Most chemicals require special shipment – please inquire<br />

4 <strong>GVL</strong>Z056 "IMI 7031" 1 insulating varnish 100ml bottle<br />

5 "IMI 7031" 1 insulating varnish 250ml bottle<br />

6 "IMI 7031" 1 insulating varnish 500ml bottle<br />

7 <strong>GVL</strong>Z076 "Stycast 2850FT", with hardener 1kg package<br />

8 <strong>GVL</strong>Z077 "Stycast 1266", A und B 1kg package<br />

9 <strong>GVL</strong>Z097 "Armstrong A12", epoxy with hardener 55g + 45g package<br />

Conducting varnish<br />

10 <strong>GVL</strong>Z054 Silver-based Epoxy-coating Elekolit 336 50g-package<br />

11 <strong>GVL</strong>Z055 Silver-based Epoxy-coating Elekolit 342 3g-package<br />

Adhesive tape<br />

12 <strong>GVL</strong>Z059 Aluminum tape, 81µm thick, conductive, 19.1mm 16.5m<br />

13 <strong>GVL</strong>Z060 Aluminum tape, 81µm thick, conductive, 25.4mm 16.5m<br />

14 <strong>GVL</strong>Z057 Aluminized polyester, non conductive, 19.1mm 66m<br />

15 <strong>GVL</strong>Z058 Aluminized polyester, non conductive, 25.4mm 66m<br />

Resistance wire (varnish insulated)<br />

16 <strong>GVL</strong>Z001 Manganin®-wire 0.03 mm diameter 100m spool<br />

17 Manganin®-wire 0.03 mm diameter 500m spool<br />

18 <strong>GVL</strong>Z002 Manganin®-wire 0.05 mm diameter 100m spool<br />

19 Manganin®-wire 0.05 mm diameter 500m spool<br />

20 <strong>GVL</strong>Z003 Manganin®-wire 0.1 mm diameter 100m spool<br />

21 Manganin®-wire 0.1 mm diameter 500m spool<br />

22 <strong>GVL</strong>Z149 Manganin®-wire 0.127 mm diameter, ML insulated 100m spool<br />

23 Manganin®-wire 0.127 mm diameter, ML insulated 500m spool<br />

24 <strong>GVL</strong>Z004 Manganin®-wire 0.14 mm diameter 100m spool<br />

25 Manganin®-wire 0.14 mm diameter 500m spool<br />

26 <strong>GVL</strong>Z005 Manganin®-wire 0.2 mm diameter 100m spool<br />

27 Manganin®-wire 0.2 mm diameter 500m spool<br />

28 <strong>GVL</strong>Z006 Manganin®-wire 0.27 mm diameter 100m spool<br />

29 Manganin®-wire 0.27 mm diameter 500m spool<br />

30 <strong>GVL</strong>Z150 Manganin®-wire 0.5 mm diameter 100m spool<br />

31 Manganin®-wire 0.5 mm diameter 500m spool<br />

32 <strong>GVL</strong>Z007 Manganin®-wire 0.56 mm diameter 100m spool<br />

33 Manganin®-wire 0.56 mm diameter 500m spool<br />

34 <strong>GVL</strong>Z050 Brass-wire 0.10 mm diameter 500m spool<br />

35 <strong>GVL</strong>Z029 Brass-wire 0.112 mm diameter 500m spool<br />

36 <strong>GVL</strong>Z151 Constantan-wire 0.10 mm diameter 100m spool<br />

37 Constantan-wire 0.10 mm diameter 500m spool<br />

38 <strong>GVL</strong>Z087 Constantan-wire 0.224 mm diameter 500m spool<br />

39 <strong>GVL</strong>Z094 NiCr80-wire 0.1 mm diameter 100m spool<br />

40 NiCr80-wire 0.1 mm diameter 500m spool<br />

41 <strong>GVL</strong>Z092 NiCr80-wire 0.2 mm diameter 100m spool<br />

42 NiCr80-wire 0.2 mm diameter 500m spool<br />

43 <strong>GVL</strong>Z095 NiCr60-wire 0.06 mm diameter 100m spool<br />

44 <strong>GVL</strong>Z104 Phosphor-Bronze wire 0.1 mm diameter 100m spool<br />

Other diameters on request<br />

Resistance wire (uninsulated)<br />

45 <strong>GVL</strong>Z093 Manganin®-wire 0.1 mm diameter 100m spool<br />

46 <strong>GVL</strong>Z112 CuNi6-wire 0.4 mm diameter 100m spool<br />

47 <strong>GVL</strong>Z146 Brass-wire 0.10 mm diameter 200m spool<br />

48 Brass-wire 0.10 mm diameter 500m spool<br />

All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if<br />

applicable, are additional - This price list voids and replaces all earlier versions.<br />

1 formerly known as GE-7031 Insulating Varnish<br />

<strong>GVL</strong> <strong>Cryoengineering</strong> Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733<br />

<strong>Dr</strong> <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong> Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783<br />

Aachener Str.89, D-52223 Stolberg (Rheinl.) www.<strong>GVL</strong>-<strong>Cryoengineering</strong>.de Geschäftsführer: <strong>Dr</strong>. G. V. <strong>Lecomte</strong>


<strong>GVL</strong> <strong>Cryoengineering</strong><br />

<strong>Dr</strong>. <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong><br />

Meß-, Regel- und Kryotechnik<br />

EXCERPT FROM THE PRODUCT LIST<br />

"CRYOGENIC ACCESSORIES"<br />

August 2011, Page 2<br />

Copper wire (varnish insulated)<br />

49 <strong>GVL</strong>Z008 Copper wire 0.050 mm diameter 100m spool<br />

50 Copper wire 0.050 mm diameter 250m spool<br />

51 Copper wire 0.050 mm diameter 500m spool<br />

52 <strong>GVL</strong>Z103 Copper wire 0.100 mm diameter, A200 insulated 250m spool<br />

53 Copper wire 0.100 mm diameter, A200 insulated 500m spool<br />

54 <strong>GVL</strong>Z062 Copper wire 0.150 mm diameter, A200 insulated 250m spool<br />

55 Copper wire 0.150 mm diameter, A200 insulated 500m spool<br />

56 <strong>GVL</strong>Z063 Copper wire 0.750 mm diameter 50m spool<br />

57 Copper wire 0.750 mm diameter 100m spool<br />

58 <strong>GVL</strong>Z064 Copper wire 1.00 mm diameter 25m spool<br />

59 Copper wire 1.00 mm diameter 50m spool<br />

Other diameters on request<br />

Superconducting wire : NbTi in copper-nickel matrix<br />

<strong>GVL</strong>Z113 NbTi core in Cu-Ni matrix, Formvar insulated,<br />

60 metal diameter: 0.05 mm 20m-Spool<br />

61 metal diameter: 0.05 mm 50m-Spool<br />

<strong>GVL</strong>Z016 NbTi core in Cu-Ni matrix, Formvar insulated,<br />

62 metal diameter: 0.06 mm 20m-Spool<br />

63 metal diameter: 0.06 mm 50m-Spool<br />

<strong>GVL</strong>Z136 NbTi core in Cu-Ni matrix, bare (uninsulated),<br />

64 metal diameter: 0.1 mm 20m-Spool<br />

65 metal diameter: 0.1 mm 50m-Spool<br />

<strong>GVL</strong>Z017 NbTi core in Cu-Ni matrix, Formvar insulated,<br />

66 metal diameter: 0.1 mm 20m-Spool<br />

67 metal diameter: 0.1 mm 50m-Spool<br />

<strong>GVL</strong>Z018 NbTi core in Cu-Ni matrix, HML insulated,<br />

68 metal diameter: 0.1 mm 20m-Spool<br />

69 metal diameter: 0.1 mm 50m-Spool<br />

<strong>GVL</strong>Z133 NbTi core in Cu-Ni matrix, MW35c insulated,<br />

70 metal diameter: 0.1 mm 20m-Spool<br />

71 metal diameter: 0.1 mm 50m-Spool<br />

<strong>GVL</strong>Z145 NbTi core in Cu-Ni matrix, Teflon FEP insulated,<br />

72 metal diameter: 0.1 mm, insulated diameter: .36 mm 20m-Spool<br />

73 metal diameter: 0.1 mm, insulated diameter: .36 mm 50m-Spool<br />

<strong>GVL</strong>Z019 NbTi core in Cu-Ni matrix, HML insulated,<br />

74 metal diameter: 0.13 mm 20m-Spool<br />

75 metal diameter: 0.13 mm 50m-Spool<br />

<strong>GVL</strong>Z020 NbTi core in Cu-Ni matrix, Formvar insulated,<br />

76 metal diameter: 0.25 mm 20m-Spool<br />

77 metal diameter: 0.25 mm 50m-Spool<br />

Superconducting wire : single NbTi filament<br />

<strong>GVL</strong>Z009 NbTi wire, without matrix, bare (uninsulated),<br />

78 metal diameter: 0.025 mm 50m-Spool<br />

<strong>GVL</strong>Z154 NbTi wire, without matrix, bare (uninsulated),<br />

79 metal diameter: 0.035 mm 50m-Spool<br />

<strong>GVL</strong>Z096 NbTi wire, without matrix, Formvar insulated,<br />

80 metal diameter: 0.040 mm 20m-Spool<br />

<strong>GVL</strong>Z010 NbTi wire, without matrix, Formvar insulated,<br />

81 metal diameter: 0.050 mm 20m-Spool<br />

<strong>GVL</strong>Z011 NbTi wire, without matrix, Formvar insulated,<br />

82 metal diameter: 0.075 mm 20m-Spool<br />

<strong>GVL</strong>Z086 NbTi wire, without matrix, Teflon insulated,<br />

83 metal diameter: 0.075 mm 20m-Spool<br />

<strong>GVL</strong>Z111 NbTi wire, without matrix, bare (uninsulated)<br />

84 metal diameter: 0.125 mm 20m-Spool<br />

<strong>GVL</strong>Z134 NbTi wire, without matrix, Formvar insulated,<br />

85 metal diameter: 0.125 mm 20m-Spool<br />

<strong>GVL</strong>Z105 NbTi wire, without matrix, HML insulated,<br />

86 metal diameter: 0.125 mm 20m-Spool<br />

All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if<br />

applicable, are additional - This price list voids and replaces all earlier versions.<br />

<strong>GVL</strong> <strong>Cryoengineering</strong> Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733<br />

<strong>Dr</strong> <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong> Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783<br />

Aachener Str.89, D-52223 Stolberg (Rheinl.) www.<strong>GVL</strong>-<strong>Cryoengineering</strong>.de Geschäftsführer: <strong>Dr</strong>. G. V. <strong>Lecomte</strong>


<strong>GVL</strong> <strong>Cryoengineering</strong><br />

<strong>Dr</strong>. <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong><br />

Meß-, Regel- und Kryotechnik<br />

EXCERPT FROM THE PRODUCT LIST<br />

"CRYOGENIC ACCESSORIES"<br />

August 2011, Page 3<br />

Superconducting wire : single NbTi filament (cont'd)<br />

<strong>GVL</strong>Z089 NbTi wire, without matrix, Formvar insulated,<br />

87 metal diameter: 0.17 mm 20m-Spool<br />

<strong>GVL</strong>Z013 NbTi wire, without matrix, HML insulated,<br />

88 metal diameter: 0.25 mm 20m-Spool<br />

<strong>GVL</strong>Z012 NbTi wire, without matrix, Teflon insulated,<br />

89 metal diameter: 0.25 mm 20m-Spool<br />

<strong>GVL</strong>Z014 NbTi wire, without matrix, HML insulated,<br />

90 metal diameter: 0.5 mm 20m-Spool<br />

<strong>GVL</strong>Z015 NbTi wire, without matrix, bare (uninsulated),<br />

91 metal diameter: 0.7 mm 50m-Spool<br />

<strong>GVL</strong>Z152 NbTi wire, without matrix, HML insulated,<br />

92 metal diameter: 1.0 mm<br />

Superconducting wire : NbTi in copper matrix<br />

<strong>GVL</strong>Z021 NbTi core in Cu matrix, Formvar insulated,<br />

93 metal diameter: 0.025 mm 50m-Spool<br />

94 metal diameter: 0.025 mm 100m-Spool<br />

<strong>GVL</strong>Z022 NbTi core in Cu matrix, Formvar insulated,<br />

95 metal diameter: 0.050 mm 50m-Spool<br />

96 metal diameter: 0.050 mm 100m-Spool<br />

<strong>GVL</strong>Z091 NbTi core in Cu matrix, Formvar insulated,<br />

97 metal diameter: 0.075 mm 50m-Spool<br />

98 metal diameter: 0.075 mm 100m-Spool<br />

<strong>GVL</strong>Z023 NbTi core in Cu matrix, Formvar insulated,<br />

99 metal diameter: 0.1 mm 50m-Spool<br />

100 metal diameter: 0.1 mm 100m-Spool<br />

<strong>GVL</strong>Z106 NbTi core in Cu matrix, HML insulated,<br />

101 metal diameter: 0.13 mm 100m-Spool<br />

102 metal diameter: 0.13 mm 250m-Spool<br />

<strong>GVL</strong>Z026 NbTi core in Cu matrix, insulated,<br />

103 metal diameter: 0.3 mm 50m-Spool<br />

104 metal diameter: 0.3 mm 100m-Spool<br />

<strong>GVL</strong>Z027 NbTi core in Cu matrix, bare (uninsulated),<br />

105 metal diameter: 0.4 mm 50m-Spool<br />

Superconducting wire : others<br />

<strong>GVL</strong>Z028 Multifilament NbTi in Cu matrix<br />

106 metal diameter: 0.114 mm 20m-Spool<br />

107 metal diameter: 0.114 mm 50m-Spool<br />

<strong>GVL</strong>Z098 Nb3Sn Wire in Cu-Ni Matrix, untreated,<br />

108 uninsulated, metal diameter: 0.13 mm<br />

Gold wire for contacting<br />

109 <strong>GVL</strong>Z061 Au 99.9%, metal diameter: 25µm, uninsulated 10m-Spool<br />

Low temperature coax cable, superconducting<br />

Minimum order for each type: 10m<br />

110 <strong>GVL</strong>Z137 Coax Cable, superconducting central conductor of NbTi<br />

in CuNi matrix, bare, outer shielding of braided CuNi<br />

single wire version per meter<br />

111 <strong>GVL</strong>Z032 Coax Cable, superconducting central conductor of NbTi<br />

in CuNi matrix, varnished, outer shielding of braided CuNi<br />

single wire version per meter<br />

112 <strong>GVL</strong>Z031 Coax Cable, superconducting central conductor of NbTi<br />

in CuNi matrix, outer shielding of braided CuNi<br />

twisted pair version per meter<br />

113 <strong>GVL</strong>Z030 Coax Cable, superconducting central conductor of NbTi<br />

in CuNi matrix, outer shielding of braided CuNi<br />

twisted triple wire version per meter<br />

All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if<br />

applicable, are additional - This price list voids and replaces all earlier versions.<br />

<strong>GVL</strong> <strong>Cryoengineering</strong> Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733<br />

<strong>Dr</strong> <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong> Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783<br />

Aachener Str.89, D-52223 Stolberg (Rheinl.) www.<strong>GVL</strong>-<strong>Cryoengineering</strong>.de Geschäftsführer: <strong>Dr</strong>. G. V. <strong>Lecomte</strong>


<strong>GVL</strong> <strong>Cryoengineering</strong><br />

<strong>Dr</strong>. <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong><br />

Meß-, Regel- und Kryotechnik<br />

EXCERPT FROM THE PRODUCT LIST<br />

"CRYOGENIC ACCESSORIES"<br />

August 2011, Page 4<br />

Low temperature coax cable<br />

Minimum order for each type: 10m<br />

114 <strong>GVL</strong>Z036 Coax Cable, central conductor of brass, approx. 8ohm/m,<br />

outer shielding of braided CuNi<br />

single wire version per meter<br />

115 <strong>GVL</strong>Z034 Coax Cable, central conductor of brass, approx. 4ohm/m,<br />

outer shielding of braided CuNi<br />

single conductor (double strand) version per meter<br />

116 <strong>GVL</strong>Z033 Coax Cable, central conductor of brass, approx. 8ohm/m,<br />

outer shielding of braided CuNi, twisted pair version,<br />

single Teflon sleeve per meter<br />

117 <strong>GVL</strong>Z141 Coax Cable, central conductor of brass, approx. 8ohm/m,<br />

outer shielding of braided CuNi, twisted pair version,<br />

each wire in own Teflon sleeve per meter<br />

118 <strong>GVL</strong>Z081 Coax Cable, central conductor of copper, approx. 1ohm/m,<br />

outer shielding of braided CuNi, with outer Teflon<br />

insulation, twisted pair version per meter<br />

119 <strong>GVL</strong>Z037 Shielding of braided CuNi alone per meter<br />

Indium Wire<br />

120 <strong>GVL</strong>Z117 Indium Wire, 99.99% Purity, 1,6mmØ per Meter<br />

121 Indium Wire, 99.99% Purity, 1,6mmØ 5m-Length<br />

122 <strong>GVL</strong>Z052 Indium Wire, 99.99% Purity, 1mmØ per Meter<br />

123 Indium Wire, 99.99% Purity, 1mmØ 5m-Length<br />

124 <strong>GVL</strong>Z053 Indium Wire, 99.9% Purity, 0.5mmØ per Meter<br />

125 Indium Wire, 99.9% Purity, 0.5mmØ 5m-Length<br />

Silicate braided sleeves<br />

<strong>GVL</strong>Z099 High temperature insulating sleeve,<br />

126 inside diameter: 0.4 mm (o.d. 1mm) per Meter<br />

127 inside diameter: 0.4 mm (o.d. 1mm) 25m-Spool<br />

<strong>GVL</strong>Z100 High temperature insulating sleeve,<br />

128 inside diameter: 1.6 mm (o.d. 2.4mm) per Meter<br />

129 inside diameter: 1.6 mm (o.d. 2.4mm) 20m-Spool<br />

PTFE insulating sleeves<br />

130 <strong>GVL</strong>Z069 PTFE insulating sleeve, od 0.7mm id 0.3mm 10m-Spool<br />

131 <strong>GVL</strong>Z070 PTFE insulating sleeve, od 0.7mm id 0.5mm 10m-Spool<br />

132 <strong>GVL</strong>Z071 PTFE insulating sleeve, od 0.8mm id 0.5mm 10m-Spool<br />

133 <strong>GVL</strong>Z072 PTFE insulating sleeve, od 0.8mm id 0.6mm 10m-Spool<br />

134 <strong>GVL</strong>Z073 PTFE insulating sleeve, od 1.0mm id 0.7mm 10m-Spool<br />

135 <strong>GVL</strong>Z074 PTFE insulating sleeve, od 1.0mm id 0.8mm 10m-Spool<br />

136 <strong>GVL</strong>Z075 PTFE insulating sleeve, od 1.2mm id 1.0mm 10m-Spool<br />

137 <strong>GVL</strong>Z090 PTFE insulating sleeve, od 1.6mm id 1.0mm 10m-Spool<br />

SQUID leads shielding sleeves<br />

138 <strong>GVL</strong>Z051 Lead/Tin sleeve to shield SQUID leads per Meter<br />

3He Gas<br />

139 <strong>GVL</strong>Z101 3He for cryogenic applications in various quantities<br />

Metal capillary tubing - copper<br />

All the following copper capillaries are sold in fabrication lengths of<br />

~3.0m - ~3.8m. They can be shipped in several pieces cut to the desired lengths.<br />

140 <strong>GVL</strong>Z040 Copper capillary, od: 1.0mm; id: 0.25mm, in lengths of 2 - 3m,<br />

per Meter<br />

141 <strong>GVL</strong>Z040 Copper capillary, od: 1.5mm; id: 1.0mm, in lengths of 2 - 3m,<br />

per Meter<br />

142 <strong>GVL</strong>Z040 Copper capillary, od: 2.0mm; id: 1.5mm, in lengths of 2 - 3m,<br />

per Meter<br />

All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if<br />

applicable, are additional - This price list voids and replaces all earlier versions.<br />

<strong>GVL</strong> <strong>Cryoengineering</strong> Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733<br />

<strong>Dr</strong> <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong> Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783<br />

Aachener Str.89, D-52223 Stolberg (Rheinl.) www.<strong>GVL</strong>-<strong>Cryoengineering</strong>.de Geschäftsführer: <strong>Dr</strong>. G. V. <strong>Lecomte</strong>


<strong>GVL</strong> <strong>Cryoengineering</strong><br />

<strong>Dr</strong>. <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong><br />

Meß-, Regel- und Kryotechnik<br />

EXCERPT FROM THE PRODUCT LIST<br />

"CRYOGENIC ACCESSORIES"<br />

August 2011, Page 5<br />

Metal capillary tubing – copper-nickel<br />

All the following copper-nickel capillaries are sold in fabrication lengths of<br />

~3.0m - ~3.8m. They can be shipped in several pieces cut to the desired lengths.<br />

Alloy is german silver: CuNi18Zn20<br />

143 <strong>GVL</strong>Z041 CuNi capillary, od: 0.3mm; id: 0.1mm, per Meter<br />

144 <strong>GVL</strong>Z142 CuNi capillary, od: 0.4mm; id: 0.1mm, per Meter<br />

145 <strong>GVL</strong>Z042 CuNi capillary, od: 0.4mm; id: 0.2mm, per Meter<br />

146 <strong>GVL</strong>Z065 CuNi capillary, od: 0.5mm; id: 0.2mm, per Meter<br />

147 <strong>GVL</strong>Z043 CuNi capillary, od: 0.5mm; id: 0.3mm, per Meter<br />

148 <strong>GVL</strong>Z088 CuNi capillary, od: 0.6mm; id: 0.3mm, per Meter<br />

149 <strong>GVL</strong>Z044 CuNi capillary, od: 0.7mm; id: 0.4mm, per Meter<br />

150 <strong>GVL</strong>Z078 CuNi capillary, od: 0.7mm; id: 0.5mm, per Meter<br />

151 <strong>GVL</strong>Z045 CuNi capillary, od: 0.8mm; id: 0.6mm, per Meter<br />

152 <strong>GVL</strong>Z107 CuNi capillary, od: 0.9mm; id: 0.5mm, per Meter<br />

153 <strong>GVL</strong>Z114 CuNi capillary, od: 0.9mm; id: 0.6mm, per Meter<br />

154 <strong>GVL</strong>Z046 CuNi capillary, od: 1.0mm; id: 0.7mm, per Meter<br />

155 <strong>GVL</strong>Z143 CuNi capillary, od: 1.1mm; id: 0.9mm, per Meter<br />

156 <strong>GVL</strong>Z066 CuNi capillary, od: 1.2mm; id: 0.8mm, per Meter<br />

157 <strong>GVL</strong>Z047 CuNi capillary, od: 1.4mm; id: 1.0mm, per Meter<br />

158 <strong>GVL</strong>Z144 CuNi capillary, od: 1.4mm; id: 1.2mm, per Meter<br />

159 <strong>GVL</strong>Z067 CuNi capillary, od: 1.5mm; id: 1.0mm, per Meter<br />

160 <strong>GVL</strong>Z139 CuNi capillary, od: 1.9mm; id: 1.2mm, per Meter<br />

161 <strong>GVL</strong>Z108 CuNi capillary, od: 1.9mm; id: 1.5mm, per Meter<br />

162 <strong>GVL</strong>Z120 CuNi capillary, od: 2.0mm; id: 1.5mm, per Meter<br />

163 <strong>GVL</strong>Z068 CuNi capillary, od: 2.0mm; id: 1.6mm, per Meter<br />

164 <strong>GVL</strong>Z138 CuNi capillary, od: 2.2mm; id: 1.2mm, per Meter<br />

165 <strong>GVL</strong>Z109 CuNi capillary, od: 2.4mm; id: 2.0mm, per Meter<br />

166 <strong>GVL</strong>Z121 CuNi capillary, od: 2.5mm; id: 2.0mm, per Meter<br />

167 <strong>GVL</strong>Z110 CuNi capillary, od: 3.0mm; id: 2.5mm, per Meter<br />

168 <strong>GVL</strong>Z048 CuNi capillary, od: 3.0mm; id: 2.6mm, per Meter<br />

169 <strong>GVL</strong>Z122 CuNi capillary, od: 3.5mm; id: 3.0mm, per Meter<br />

170 <strong>GVL</strong>Z123 CuNi capillary, od: 4.0mm; id: 3.5mm, per Meter<br />

171 <strong>GVL</strong>Z049 CuNi capillary, od: 4.0mm; id: 3.6mm, per Meter<br />

172 <strong>GVL</strong>Z131 CuNi capillary, od: 4.5mm; id: 4.0mm, per Meter<br />

173 <strong>GVL</strong>Z124 CuNi capillary, od: 5.0mm; id: 4.0mm, per Meter<br />

174 <strong>GVL</strong>Z125 CuNi capillary, od: 6.0mm; id: 5.0mm, per Meter<br />

175 <strong>GVL</strong>Z115 CuNi capillary, od: 6.0mm; id: 5.5mm, per Meter<br />

176 <strong>GVL</strong>Z116 CuNi capillary, od: 7.0mm; id: 6.0mm, per Meter<br />

177 <strong>GVL</strong>Z126 CuNi capillary, od: 8.0mm; id: 7.0mm, per Meter<br />

178 <strong>GVL</strong>Z132 CuNi capillary, od: 12.0mm; id: 11.0mm, per Meter<br />

Bondable Terminals<br />

179 <strong>GVL</strong>Z082 4 contact pairs, 2.7mm x 10.2mm 70pcs<br />

180 <strong>GVL</strong>Z083 4 contact pairs, 3.4mm x 13.8mm 60pcs<br />

181 <strong>GVL</strong>Z084 4 contact pairs, 4.5mm x 17.4mm 50pcs<br />

182 <strong>GVL</strong>Z085 4 contact pairs, 6.4mm x 23.4mm 30pcs<br />

Low Temperature Terminals (in-line connectors in 2.54mm step)<br />

183 <strong>GVL</strong>Z156 12 contact pairs, male 1pcs<br />

184 <strong>GVL</strong>Z157 12 contact pairs, female 1pcs<br />

185 <strong>GVL</strong>Z158 12 contact pairs, female, low profile 1pcs<br />

186 <strong>GVL</strong>Z129 20 contact pairs, male 1pcs<br />

187 <strong>GVL</strong>Z130 20 contact pairs, female 1pcs<br />

188 <strong>GVL</strong>Z155 20 contact pairs, female, low profile 1pcs<br />

All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if<br />

applicable, are additional - This price list voids and replaces all earlier versions.<br />

<strong>GVL</strong> <strong>Cryoengineering</strong> Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733<br />

<strong>Dr</strong> <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong> Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783<br />

Aachener Str.89, D-52223 Stolberg (Rheinl.) www.<strong>GVL</strong>-<strong>Cryoengineering</strong>.de Geschäftsführer: <strong>Dr</strong>. G. V. <strong>Lecomte</strong>


<strong>GVL</strong> <strong>Cryoengineering</strong><br />

<strong>Dr</strong>. <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong><br />

Meß-, Regel- und Kryotechnik<br />

EXCERPT FROM THE PRODUCT LIST<br />

"CRYOGENIC ACCESSORIES"<br />

August 2011, Page 6<br />

Low Temperature MCX-Miniature Coax Connectors<br />

Wave impedance: 50Ω / Frequency range: 2GHz<br />

189 <strong>GVL</strong>Z118 MCX connector, male, goldplated, straight 1pcs<br />

190 <strong>GVL</strong>Z119 MCX connector, male, goldplated, 90° angle 1pcs<br />

191 <strong>GVL</strong>Z153 MCX connector, female, goldplated, straight 1pcs<br />

192 <strong>GVL</strong>Z102 MCX connector, female, goldplated, threaded mount 1pcs<br />

Room Temperature Coax Vacuum Feedthroughs<br />

Wave impedance: 50Ω / Frequency range: 1.5GHz<br />

193 <strong>GVL</strong>Z147 Coax feedthrough, female, M7 thread 1pcs<br />

194 <strong>GVL</strong>Z148 Male plug for above, straight 1pcs<br />

Room Temperature Vacuum Feedthroughs<br />

195 <strong>GVL</strong>Z159 24pin feedthrough, female 1pcs<br />

196 <strong>GVL</strong>Z160 Male plug for above, straight 1pcs<br />

All prices are understood from Stolberg, FRG, packing, shipping and all taxes, if<br />

applicable, are additional - This price list voids and replaces all earlier versions.<br />

<strong>GVL</strong> <strong>Cryoengineering</strong> Tel. 02402 24566 Sitz: 52223 Stolberg, AG Aachen HRB 10733<br />

<strong>Dr</strong> <strong>George</strong> V. <strong>Lecomte</strong> <strong>GmbH</strong> Fax 02402 26739 Deutsche Bank Aachen BLZ 390 700 24 Kto 2703783<br />

Aachener Str.89, D-52223 Stolberg (Rheinl.) www.<strong>GVL</strong>-<strong>Cryoengineering</strong>.de Geschäftsführer: <strong>Dr</strong>. G. V. <strong>Lecomte</strong>

Hooray! Your file is uploaded and ready to be published.