Technical Specification RHK-AK - Heizomat
Technical Specification RHK-AK - Heizomat
Technical Specification RHK-AK - Heizomat
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Technical</strong> <strong>Specification</strong> <strong>RHK</strong>-<strong>AK</strong><br />
<strong>RHK</strong>-<strong>AK</strong><br />
30<br />
<strong>RHK</strong>-<strong>AK</strong><br />
205<br />
<strong>RHK</strong>-<strong>AK</strong><br />
300<br />
<strong>RHK</strong>-<strong>AK</strong><br />
400<br />
<strong>RHK</strong>-<strong>AK</strong><br />
500<br />
<strong>RHK</strong>-<strong>AK</strong><br />
650<br />
<strong>RHK</strong>-<strong>AK</strong><br />
850<br />
<strong>RHK</strong>-<strong>AK</strong><br />
1000<br />
Heat Load (kW) 0-200 0-300 0-400 0-500 0-600 0-800 0-990<br />
Heat exchange surface (m 2 ) 18,0 29,70 33,75 37,10 56,0 74,0 85,0<br />
Water capacity (l) 660 1258 1580 1805 2680 3940 5600<br />
Operating pressure max (bar) 3,0 3,0 3,0 3,0 3,0 3,0 3,0<br />
Weight (kg) 2860 5400 6200 6800 8500 9900 14000<br />
Length l (mm) 3365 3490 3990 4290 4385 5086 5500<br />
Width b (mm) 1150 1880 1880 1880 2146 2146 2650<br />
Height h (mm) 2056 2035 2035 2035 2066 2066 3050<br />
Boiler shell length (mm) 2800 3150 3650 3950 3800 4500 4950<br />
Boiler shell width (mm) 930 1695 1695 1695 1960 1960 2500<br />
Boiler shell height (mm) 1950 1925 1925 1925 1960 1960 2650<br />
Flue tube height RRh (mm) -- 2225 2225 2225 2307 2307 2950<br />
Flue tube height RRh* (mm) 1925 1771 1771 1771 -- -- --<br />
Flue tube Ø (mm) 300 300 350 350 400 400 500<br />
Heat flow DN 80 DN 80 DN 80 DN 80 DN 80 DN 125 DN 150<br />
Heat return DN 80 DN 80 DN 80 DN 80 DN 80 DN 125 DN 150<br />
Safety heat flow 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“ DN 80 DN 80 DN 100<br />
Safety heat return 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“ DN 80 DN 80 DN 100<br />
Boiler temperature max (°C) 95 95 95 95 95 95 95<br />
Return temperature min (°C) >55 >55 >55 >55 >55 >55 >55<br />
Power supply 400V / 16A<br />
5-pin<br />
<strong>RHK</strong>-<strong>AK</strong><br />
50<br />
400V / 16A<br />
5-pin<br />
<strong>RHK</strong>-<strong>AK</strong><br />
60<br />
400V / 16A<br />
5-pin<br />
<strong>RHK</strong>-<strong>AK</strong><br />
75<br />
400V / 16A<br />
5-pin<br />
<strong>RHK</strong>-<strong>AK</strong><br />
100<br />
<strong>RHK</strong>-<strong>AK</strong><br />
154<br />
400V / 16A<br />
5-pin<br />
<strong>RHK</strong>-<strong>AK</strong><br />
155<br />
400V / 16A<br />
5-pin<br />
<strong>RHK</strong>-<strong>AK</strong><br />
204<br />
Heat Load (kW) 0-36 0-50 0-60 0-75 0-101 0-149 0-149 0-200<br />
Heat exchange surface (m 2 ) 3,40 4,50 5,60 7,20 8,90 14,10 13,90 18,00<br />
Water capacity (l) 165 205 250 385 475 712 510 985<br />
Operating pressure max (bar) 3,0 3,0 3,0 3,0 3,0 3,0 3,0 3,0<br />
Weight (kg) 900 1000 1150 1400 1500 2570 2320 3108<br />
Length l (mm) 1700 1900 2100 1950 2200 2790 2320 3290<br />
Width b (mm) 860 860 860 1085 1085 1565 1150 1565<br />
Height h (mm) 1585 1585 1585 1700 1700 1895 2065 1895<br />
Boiler shell length (mm) 1550 1750 1950 1550 1800 2400 2300 2900<br />
Boiler shell width (mm) 665 665 665 890 890 1375 930 1375<br />
Boiler shell height (mm) 1600 1600 1600 1645 1645 1770 1950 1770<br />
Flue tube height RRh (mm) 1770 1770 1770 1770 1850 2070 --- 2070<br />
Flue tube height RRh* (mm) 1300 1300 1300 1400 1490 1618 1925 1618<br />
Flue tube Ø (mm) 200 200 200 200 250 300 300 300<br />
Heat flow 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“ DN 80 DN 80 DN 80<br />
Heat return 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“ DN 80 DN 80 DN 80<br />
Safety heat flow 1“ 1“ 1“ 1“ 1“ 1 1/2“ 1 1/2“ 1 1/2“<br />
Safety heat return 1“ 1“ 1“ 1“ 1“ 1 1/2“ 1 1/2“ 1 1/2“<br />
Boiler temperature max (°C) 95 95 95 95 95 95 95 95<br />
Return temperature min (°C) >55 >55 >55 >55 >55 >55 >55 >55<br />
Power supply 400V / 16A<br />
5-pin<br />
<strong>Heizomat</strong> Gerätebau-<br />
Energiesysteme GmbH<br />
Maicha 21<br />
D-91710 Gunzenhausen<br />
Germany<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
Energy in Balance with Nature<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
Phone +49 (0) 98 36 / 97 97 - 0<br />
Fax +49 (0) 98 36 / 97 97 - 97<br />
info@heizomat.de<br />
www.heizomat.de
<strong>Technical</strong> <strong>Specification</strong> HSK-RA<br />
<strong>Heizomat</strong> Gerätebau-<br />
Energiesysteme GmbH<br />
Maicha 21<br />
D-91710 Gunzenhausen<br />
Germany<br />
HSK-RA<br />
30<br />
HSK-RA<br />
40<br />
Energy in Balance with Nature<br />
HSK-RA<br />
60<br />
HSK-RA<br />
75<br />
Heat Load (kW) 0 - 33 0 - 40 0 - 60 0 - 75<br />
Heat exchange surface (m 2 ) 3,80 4,90 5,90 8,10<br />
Water capacity (l) 188 210 255 280<br />
Operating pressure max (bar) 3,0 3,0 3,0 3,0<br />
Weight (kg) 770 860 950 1300<br />
Length l (mm) 935 1135 1335 1335<br />
Width b (mm) 740 740 740 890<br />
Height h (mm) 1440 1440 1440 1550<br />
Boiler shell length (mm) 1067 1267 1467 1467<br />
Boiler shell width (mm) 775 775 775 925<br />
Boiler shell height (mm) 1392 1392 1392 1486<br />
Flue tube height RRh (mm) 1250 1250 1250 1300<br />
Flue tube height RRh* (mm) 1560 1560 1560 1660<br />
Flue tube Ø (mm) 200 200 200 200<br />
Heat flow 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“<br />
Heat return 1 1/2“ 1 1/2“ 1 1/2“ 1 1/2“<br />
Safety heat flow 1“ 1“ 1“ 1“<br />
Safety heat return 1“ 1“ 1“ 1“<br />
Boiler temperature max (°C) 95 95 95 95<br />
Return temperature min (°C) >55 >55 >55 >55<br />
Power supply 400V / 16A<br />
5-pin<br />
HSK-RA<br />
100<br />
400V / 16A<br />
5-pin<br />
HSK-RA<br />
150<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
HSK-RA<br />
200<br />
Heat Load (kW) 0 - 96 0 - 150 0 - 200<br />
Heat exchange surface (m 2 ) 10,50 15,70 20,90<br />
Water capacity (l) 360 625 810<br />
Operating pressure max (bar) 3,0 3,0 3,0<br />
Weight (kg) 1470 2140 2660<br />
Length l (mm) 1635 1635 2135<br />
Width b (mm) 890 930 930<br />
Height h (mm) 1550 1980 1980<br />
Boiler shell length (mm) 1767 1695 2195<br />
Boiler shell width (mm) 925 975 975<br />
Boiler shell height (mm) 1486 1922 1922<br />
Flue tube height RRh (mm) 1300 1960 1960<br />
Flue tube height RRh* (mm) 1660 2150 2150<br />
Flue tube Ø (mm) 250 300 300<br />
Heat flow 1 1/2“ 2“ 2“<br />
Heat return 1 1/2“ 2“ 2“<br />
Safety heat flow 1“ 1 1/4“ 1 1/4“<br />
Safety heat return 1“ 1 1/4“ 1 1/4“<br />
Boiler temperature max (°C) 95 95 95<br />
Return temperature min (°C) >55 >55 >55<br />
Power supply 400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
400V / 16A<br />
5-pin<br />
Phone +49 (0) 98 36 / 97 97 - 0<br />
Fax +49 (0) 98 36 / 97 97 - 97<br />
info@heizomat.de<br />
www.heizomat.de