Assembly<br />

<strong>Air</strong> <strong>Star</strong> <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong><br />

<strong>Air</strong> <strong>Star</strong> <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong> can be installed in two ways. Recessed into the wall is the preferred method<br />

in environments with high demands on aesthetics, and where the wall structure requires this. Directly<br />

on the inside of the interior wall provides the simplest installation and has the same function. Page 11<br />

features a drawing of the outer box with all dimensions. The dimensions of the outer box are 290 x 340<br />

mm; add 10-15 mm for the insulation when mounting the <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong> recessed into the wall.<br />

Location of ventilator <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong><br />

Before mounting the unit, determine the location. Please note the following points before starting the<br />

installation:<br />

• Make sure that there is nothing on the outside of the building where the ventilation grill is to be<br />

installed.<br />

• Take the wall studs into account.<br />

• Locate the power lines.<br />

• Do not place the ventilator so that it ends up behind furniture or anything that reduces the air<br />

change rate.<br />

• For high placement of the ventilator, the top of the outer box should be at least 10 cm from the<br />

ceiling, bearing in mind the unit draws in air from above and in order to ensure access to open<br />

the door with the door opener.<br />

• Remember that in order to open the door properly, you need to make sure you have at least a<br />

10 cm gap to the nearest wall.<br />

• The length of the Spiro pipe must be no more than 1 metre.<br />

• Try placing the ventilator under or at the side of a window.<br />

• The bottom edge of the outer box should be <strong>20</strong>-<strong>30</strong> cm above the floor.<br />

• Make sure the power cord is long enough to lift the ventilator from the outer box.<br />

• Mount high up in a shower room and basement.<br />

Equipment & tools<br />

Stud finder<br />

Folding rule<br />

Spirit level<br />

Driller<br />

Drill Ø12-15mm<br />

Tiger saw<br />

Hammer<br />

Respiratory protection<br />

Vacuum cleaner<br />

Components<br />

Outer box<br />

Spiro pipe<br />

Ventilation unit<br />

Heat exchanger cassette<br />