Assembly<br />
<strong>Air</strong> <strong>Star</strong> <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong><br />
<strong>Air</strong> <strong>Star</strong> <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong> can be installed in two ways. Recessed into the wall is the preferred method<br />
in environments with high demands on aesthetics, and where the wall structure requires this. Directly<br />
on the inside of the interior wall provides the simplest installation and has the same function. Page 11<br />
features a drawing of the outer box with all dimensions. The dimensions of the outer box are 290 x 340<br />
mm; add 10-15 mm for the insulation when mounting the <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong> recessed into the wall.<br />
Location of ventilator <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong><br />
Before mounting the unit, determine the location. Please note the following points before starting the<br />
installation:<br />
• Make sure that there is nothing on the outside of the building where the ventilation grill is to be<br />
installed.<br />
• Take the wall studs into account.<br />
• Locate the power lines.<br />
• Do not place the ventilator so that it ends up behind furniture or anything that reduces the air<br />
change rate.<br />
• For high placement of the ventilator, the top of the outer box should be at least 10 cm from the<br />
ceiling, bearing in mind the unit draws in air from above and in order to ensure access to open<br />
the door with the door opener.<br />
• Remember that in order to open the door properly, you need to make sure you have at least a<br />
10 cm gap to the nearest wall.<br />
• The length of the Spiro pipe must be no more than 1 metre.<br />
• Try placing the ventilator under or at the side of a window.<br />
• The bottom edge of the outer box should be <strong>20</strong>-<strong>30</strong> cm above the floor.<br />
• Make sure the power cord is long enough to lift the ventilator from the outer box.<br />
• Mount high up in a shower room and basement.<br />
Equipment & tools<br />
Stud finder<br />
Folding rule<br />
Spirit level<br />
Driller<br />
Drill Ø12-15mm<br />
Tiger saw<br />
Hammer<br />
Respiratory protection<br />
Vacuum cleaner<br />
Components<br />
Outer box<br />
Spiro pipe<br />
Ventilation unit<br />
Heat exchanger cassette<br />
User Manual 6 Version 1.6