Maintenance Air Star Comfort 20/30 Opening the ventilation unit Unplug the power cord. When you need to open the ventilation unit, it is recommended to grip the top of the front cover (2) and pull it towards you. There is a joint at the bottom edge that secures the front door so that it cannot be removed. To close, just lift the cover and press it to its original position. Removing and installing the ventilator Open the ventilation unit’s front door as instructed on page. 4. Now grip the top of the front cover (2) and gently pull it out. Cleaning the ventilator Open the door of the Comfort 20/30 by pushing at the same time as inserting the door opener into the hole at the top of the door. Carefully disconnect the cable connection from the door. Open the cover on the ventilator by gripping the top and pulling towards you. Remove the heat exchanger cassette. Vacuum or dust inside the ventilator, cover and the heat exchanger cassette. For thorough cleaning, you may want to remove the unit from the outer box. Before refitting the ventilator in the outer box, this should also be cleaned. Replacing the filter 1. 2. 3. 4. To obtain the best efficiency, the supply air and exhaust air filters need to be replaced regularly, at least twice a year. If the units are placed in a very dirty environment, the filters must be replaced more often. When the front cover on the ventilation unit is opened, for the Comfort models this is done by inserting the accompanying red needles into the small hole on the left side, on top of the ventilator cover. 1. An exhaust air filter is located on the top edge of the front. 2. Remove it from the Velcro strip and replace it with a new one. 3. Grip the top edge of the ventilator, fold down the front of the ventilation unit and remove the heat exchanger. 4. Lift the cover and grill to access the supply air filter. It is a good idea to use a vacuum cleaner and vacuum the corrugated board in the heat exchanger, and vacuum and wipe the exposed parts of the unit with a damp cloth. This increases the unit’s life span considerably! Note: Make sure the cover on the heat exchanger cassette is facing upwards when refitting in the ventilation unit. • Standard filter BG/160-65, not cleanable. • Dust filter EG/150-65, not cleanable. • Pollen filter EF/300-45, not cleanable. (Only available as option). User Manual 10 Version 1.6

Assembly drawing Air Star Comfort 20/30 For the holes, add 10-15 mm to the external dimensions for insulation. 297 340 Ø 122,5 41 204 204 81,5 290 User Manual 11 Version 1.6

Assembly drawing<br />

<strong>Air</strong> <strong>Star</strong> <strong>Comfort</strong> <strong>20</strong>/<strong>30</strong><br />

For the holes, add 10-15 mm to the external dimensions for insulation.<br />

297<br />

340<br />

Ø 122,5<br />

41<br />

<strong>20</strong>4<br />

<strong>20</strong>4<br />

81,5<br />

290<br />

User Manual 11 Version 1.6