10.2<br />

IrDA Diagnostics &<br />

Config. IQ Insight –<br />

IrDA Comms [Ir]<br />

72<br />

IQ Insight software tool for PC has been<br />

developed to enable the actuator<br />

configuration and onboard datalogger<br />

to be reconfigured and analysed.<br />

To enable communication with IQ<br />

Insight the actuator IrDA interface must<br />

be enabled.<br />

A PC running IQ Insight software may<br />

be located at the actuator or, using a<br />

cell phone link, at a remote site (for<br />

information on IQ Insight see<br />

www.rotork.com).<br />

The default setting for IQ IrDA is [On],<br />

enabling IrDA.<br />

To disable IrDA use the + or - key. The<br />

display will change to [OF].<br />

PRESS THE KEY.<br />

The displayed option will flash<br />

indicating it has been set.<br />

IQ Insight – IrDA Communication<br />

Enabled.<br />

10.2 IrDA Diagnostics &<br />

Config. IQ Insight –<br />

Cell Phone [Ic]<br />

Using IQ Insight software tool, remote<br />

diagnostics can be enabled using a cell<br />

phone located at the actuator to<br />

transmit and receive data to and from a<br />

remote PC running IQ Insight software.<br />

The cell phone must be IrDA<br />

compatible and have access to a<br />

transmit/receive data line (contact your<br />

cell phone manufacturer and service<br />

provider).<br />

(For information on IQ Insight software<br />

refer to publication E111E).<br />

The actuator IrDA feature must be<br />

enabled (refer to [Ir] IQ Insight – IrDA<br />

Comms).<br />

Before starting, the cell phone must be<br />

configured for "data" as opposed to<br />

‘‘voice’’ and be positioned in direct line<br />

of sight to the actuator display, no<br />

more than 0.5m (2ft) from the display.<br />

The default setting for IQ Insight – Cell<br />

Phone is [OF].<br />

To enable remote diagnostics use the +<br />

or - key. The display will change to<br />

[On].<br />

PRESS THE<br />

KEY.<br />

The actuator display will automatically<br />

return to indicating the current<br />

position.<br />

The actuator will search for a<br />

compatible IrDA device within range for<br />

approximately 30 seconds.<br />

On establishing communication, the<br />

actuator display will indicate the symbol<br />

shown below.