9.7 Remote Control Source Od Remote Control Source 42 The available forms of remote control are listed below: Standard hardwired control Analogue control-Option Folomatic Network control including: Option Pakscan Option Modbus Option Profibus The setting for Remote Control Source will depend on the type of remote control required and the option specified and fitted. Check actuator circuit diagram for remote control form. The setting of Remote Control Source will be determined by the option that has been fitted, if any. [rE] Standard hardwired remote control. [bo] Option Folomatic. [oP] Options Pakscan, Profibus, Modbus, Foundation Fieldbus or DeviceNet. [OF] All remote control disabled (Actuator available for local control only). To change the remote source press the + or - key until the required setting is displayed. PRESS THE KEY. The displayed option will flash indicating that it has been set. Standard Hardwired Remote Control
9.8 Bus System Option Pakscan [OP] Pakscan Address PA Pb Pakscan Baud Rate 43 Setting instructions for actuators including an optional Pakscan Field Control Unit – check wiring diagram for inclusion. Before setting the parameters for Option Pakscan ensure Remote Control Source [Od] has been selected to [oP] in Section 9.7. (refer to page 42) Pakscan set-up screens can be turned off to provide extra security. The action of turning screens on or off does not affect its operation. Use the + or - key to turn on Pakscan set-up screens. Pakscan Set-up Screens ON PRESS THE KEY. The displayed option will flash indicating that it has been set. Press the ◗ key to display the Pakscan set-up screens. The actuator Pakscan Field Control Unit must be allocated a unique loop address. The actuator must be in “Loopback” for its address to be set or changed. Loopback can be achieved in two ways: 1. Turn OFF the master station. 2. Isolate the actuator from the 2-wire control loop. Using the + or - keys display the required loop address. Address to be set within the range 01–F0 Hexadecimal. (refer to table on page 75). The actuator Pakscan Field Control Unit baud rate must be set to the loop baud rate. For a Pakscan 2-wire control loop the selected baud rate must be common to the master station and all the field control units included in the loop. The actuator must be in “Loopback” for its baud rate to be set or changed. Loopback can be achieved in two ways: 1. Turn OFF the master station. 2. Isolate the actuator from the 2-wire control loop. PRESS THE KEY. The displayed option will flash indicating that it has been set. Press the ❖ key to display [Pb]. Continued
- Page 338 and 339: Remote control circuits Remote cont
- Page 340 and 341: Analogue control circuits Analogue
- Page 342 and 343: UK head office Rotork Controls Limi
- Page 344 and 345: The Rotork Setting Tool allows actu
- Page 347 and 348: CONTENTS Page 1 Health and Safety 2
- Page 349 and 350: 2 Storage 3 Operating your IQ Actua
- Page 351 and 352: 5 3.4 Display-Alarm Indication The
- Page 353 and 354: 4 Preparing Drive Bush 7 4.1 IQ10 t
- Page 355 and 356: 9 Fig. 4.9 Type A Drive Bush in Pos
- Page 357 and 358: 11 5.1 Rising Stem Valves - Top Mou
- Page 359 and 360: 13 5.7 IQML Adjusting Linear Stroke
- Page 361 and 362: 15 6.4 Connecting to Terminals On E
- Page 363 and 364: 17 7.2 The Setting Tool Specificati
- Page 365 and 366: 19 7.7 Procedure Branch - Crossroad
- Page 367 and 368: 21 Viewing the Primary Function Set
- Page 369 and 370: C2 Close Action 23 The actuator can
- Page 371 and 372: tC Torque Value Closing 25 The valu
- Page 373 and 374: LC Set Limit Closed LO Set Limit Op
- Page 375 and 376: Fig. 9 9 Commissioning - Secondary
- Page 377 and 378: SECONDARY FUNCTIONS CONTENTS page 9
- Page 379 and 380: 1 Contact S1 - Value r1 Contact S1
- Page 381 and 382: A4 ESD Override Interlocks A5 ESD O
- Page 383 and 384: 9.4 Option Extra Indication Contact
- Page 385 and 386: 9.6 Option Folomatic Remote Control
- Page 387: Fd Deadband Adjustment Ft Motion In
- Page 391 and 392: PF Pakscan Remote Auxiliary Input 4
- Page 393 and 394: 9.9 Bus System Option Modbus [OP] P
- Page 395 and 396: PF Modbus Remote Auxiliary Input PP
- Page 397 and 398: 9.10 Bus System Option Profibus DP
- Page 399 and 400: PF Profibus Remote Auxiliary Input
- Page 401 and 402: 9.11 Option DeviceNet PA DeviceNet
- Page 403 and 404: PF DeviceNet Remote Auxiliary Input
- Page 405 and 406: Fd Bus System Deadband Adjustment A
- Page 407 and 408: JO Position in Valve Opening Stroke
- Page 409 and 410: 9.16 Default Options [d1] and [d2]
- Page 411 and 412: 10 Maintenance, Monitoring and Trou
- Page 413 and 414: 10 Maintenance, Monitoring and Trou
- Page 415 and 416: H3 Factors Inhibiting Electrical Op
- Page 417 and 418: H6 Torque Switch Status & IR Settin
- Page 419 and 420: 10.2 IrDA Diagnostics & Config. IQ
- Page 421 and 422: BHD Binary, Hexadecimal and Decimal
- Page 423 and 424: If your Rotork actuator has been co
- Page 425 and 426: New Zealand Wellington Agent North
- Page 428: Heading ATTENTION: RED PLASTIC PLUG
9.8 Bus System<br />
Option Pakscan [OP]<br />
Pakscan Address<br />
PA Pb Pakscan<br />
Baud Rate<br />
43<br />
Setting instructions for actuators<br />
including an optional Pakscan Field<br />
Control Unit – check wiring diagram for<br />
inclusion.<br />
Before setting the parameters for<br />
Option Pakscan ensure Remote<br />
Control Source [Od] has been<br />
selected to [oP] in Section 9.7.<br />
(refer to page 42)<br />
Pakscan set-up screens can be turned<br />
off to provide extra security. The action<br />
of turning screens on or off does not<br />
affect its operation.<br />
Use the + or - key to turn on Pakscan<br />
set-up screens.<br />
Pakscan Set-up Screens ON<br />
PRESS THE KEY.<br />
The displayed option will flash<br />
indicating that it has been set.<br />
Press the ◗ key to display the Pakscan<br />
set-up screens.<br />
The actuator Pakscan Field Control Unit<br />
must be allocated a unique loop<br />
address.<br />
The actuator must be in “Loopback”<br />
for its address to be set or changed.<br />
Loopback can be achieved in two ways:<br />
1. Turn OFF the master station.<br />
2. Isolate the actuator from the<br />
2-wire control loop.<br />
Using the + or - keys display the<br />
required loop address.<br />
Address to be set within the range<br />
01–F0 Hexadecimal. (refer to table on<br />
page 75).<br />
The actuator Pakscan Field Control Unit<br />
baud rate must be set to the loop baud<br />
rate. For a Pakscan 2-wire control loop<br />
the selected baud rate must be common<br />
to the master station and all the field<br />
control units included in the loop.<br />
The actuator must be in “Loopback”<br />
for its baud rate to be set or changed.<br />
Loopback can be achieved in two ways:<br />
1. Turn OFF the master station.<br />
2. Isolate the actuator from the<br />
2-wire control loop.<br />
PRESS THE KEY.<br />
The displayed option will flash<br />
indicating that it has been set.<br />
Press the ❖ key to display [Pb].<br />
Continued