9.6 Option Folomatic<br />

Remote Control<br />

Folomatic Feedback<br />

OI OF Display Folomatic<br />

Set-up Screens<br />

39<br />

Setting instructions for actuators<br />

including a Folomatic<br />

(proportional) Controller for use<br />

in (analogue) valve position<br />

control.<br />

The Folomatic is an optional<br />

control device. Check actuator<br />

wiring diagram for inclusion.<br />

This instruction lists the Folomatic<br />

function displays in their sequence and<br />

assumes that all Folomatic functions are<br />

to be checked/set.<br />

The actuator should be selected in Local<br />

or Stop with the set point signal<br />

connected to terminals 26(+ve) and<br />

27(–ve) (refer to wiring diagram).<br />

Before commissioning of the Folomatic<br />

functions can begin, the Folomatic<br />

Feedback must be set to suit the<br />

applied set point signal.<br />

The action of turning on the Folomatic<br />

option makes an additional series of<br />

settings available.<br />

Before setting the parameters for<br />

Option Folomatic ensure Remote<br />

Control Source [Od] has been<br />

selected to [bo] in Section 9.7.<br />

Folomatic set-up screens can be turned<br />

OFF to provide extra security.<br />

Once selected ON the option function<br />

displays allow commissioning of the<br />

Folomatic to be undertaken.<br />

NOTE: Turning ON/OFF the Folomatic<br />

set-up screens (when fitted) does not<br />

affect its operation.<br />

With [HI] displayed, an increasing set<br />

point signal will correspond to valve<br />

opening.<br />

If a high set point signal is required to<br />

correspond to valve closing use the + or<br />

- key to change to [LO].<br />

PRESS THE KEY.<br />

The displayed option will flash<br />

indicating that it has been set.<br />

If setting [OI] is modified after<br />

commissioning the Folomatic, it will be<br />

necessary to recommission the<br />

Folomatic.<br />

Press the ❖ key to access the<br />

Folomatic set-up display [OF].<br />

Folomatic Folomatic<br />

Set-up Screens Set-up Screens<br />

OFF<br />

ON<br />

Use the + or - key to select Folomatic<br />

Display [On].<br />

PRESS THE KEY.<br />

The displayed option will flash<br />

indicating that it has been set.<br />

Press the ◗ key to access the<br />

Folomatic set-up displays.