Actuator circuit diagram – basic<br />

IQ Actuator Basic Circuit Diagram 3000-000, drawn in mid-travel, power off<br />

Motor<br />

Thermostat<br />

Motor<br />

Switching<br />

Module<br />

FS1<br />

3<br />

1<br />

2<br />

E<br />

Actuator Power Supply<br />

Refer to page 4<br />

(power supply connections will vary with<br />

actuator type. Connections shown are<br />

for IQ 3 phase only).<br />

Position &<br />

Torque/Limit<br />

Control<br />

–<br />

+<br />

PS1<br />

4<br />

5<br />

Isolated, nominal 24V DC, 5W<br />

Power Supply (<strong>12</strong>0V AC 15VA option)<br />

Available for actuator fed remote control.<br />

Refer to page 6<br />

Local Indication<br />

Refer to page 9<br />

Remote Indication<br />

MONITOR<br />

RELAY<br />

42<br />

43<br />

44<br />

Monitor Relay Monitors actuator<br />

availability (shown de-energised –<br />

unavailable). Refer to page 9<br />

9V<br />

INFRA RED<br />

%<br />

OPEN<br />

Local and Remote<br />

Position Indication<br />

Back-up Supply<br />

(Main Power Off)<br />

Make at Fully Shut<br />

Make at Fully Open<br />

Break at Fully Shut<br />

Break at Fully Open<br />

S1<br />

S2<br />

S3<br />

S4<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

<strong>12</strong><br />

13<br />

Indication Contacts<br />

Shown in default configuration.<br />

Configuration can be changed using<br />

the IQ Setting Tool to indicate any<br />

valve position, status and alarm<br />

settings. Refer to page 9<br />

Local Controls<br />

Refer to page 7<br />

Close – Open<br />

Stop<br />

Local – Remote<br />

Remote Controls<br />

Close<br />

Stop/Maintain<br />

Open<br />

Common –ve 20–60V AC/DC<br />

Common –ve 60–<strong>12</strong>0V AC<br />

ESD<br />

Open Interlock<br />

Close Interlock<br />

Common –ve 20–60V AC/DC<br />

Common –ve 60–<strong>12</strong>0V AC<br />

<strong>33</strong><br />

34<br />

35<br />

36<br />

40<br />

25<br />

37<br />

38<br />

31<br />

32<br />

Remote Control Inputs<br />

Refer to pages 15 and 16 for<br />

control circuit types.<br />

Valve<br />

Data<br />

Data Logger/IrDA (page 3)<br />

Condition<br />

Monitoring<br />

Actuator<br />

Configuration<br />

Infra-red/IrDA interface<br />

Optional Control<br />

and Indication Equipment<br />

For applicable Circuit Diagram<br />

refer to the Matrix on page 14<br />

The Infra-red Setting Tool enables<br />

options to be configured<br />

<strong>12</strong>