Heat detector, Insemination <strong>instruments</strong>, Ultrasound units,<br />

Obstetric <strong>instruments</strong><br />

Ultrasound unit<br />

Preg-Tone ultrasound unit<br />

Originally RENCO, ultrasound tester for the diagnosis of<br />

pregnancy in sows<br />

Pigs: Safe pregnancy diagnosis between the 25th and 75th<br />

day after insemination<br />

Sheep: Safe pregnancy diagnosis between the 40th and<br />

80th day after insemination<br />

Delivered complete with cable, battery recharger in transportation<br />

box<br />

• handy pocket instrument in a metal case, sized 15 x 7 x<br />

4,5 cm<br />

• easy operation by acoustic signal tones:<br />

pregnancy = continuous tone<br />

no pregnancy = intermittent tone<br />

01605.000<br />

Battery charger<br />

Smooth cable with plug<br />

01605.020<br />

01605.070<br />

Preg-Tone<br />

The Preg-Tone ultrasonic device emitted sound waves in the high frequency range, which means ultrasound.<br />

The unit measures the amnion fluid which fills the uterus after insemination. The head has to be<br />

held on the right side and the ultra sound will be reflected from the fluid. If the uterus does not contain<br />

amnion fluid no reflection will be received and that means not pregnant. If the animal is pregnant, you<br />

will hear a continuous tone. If the animal is not pregnant, you will hear an intermittent tone. So you can<br />

clearly hear, if the animal is pregnant or not.<br />

Place the head between the 2nd and 3rd teat, ca. 3 cm upwards and 45° angled ahead, so that you do<br />

not meet the bladder. The sonar beam should pass the animal‘s spine 1 cm beneath, at the other side.<br />

Keep the head good on the skin but not with too much pressure to avoid deforming at the body area.<br />

Change also the direction of the beam so that you meet the whole uterus. No signal shows that a smooth<br />

contact has not been made. If you place the head too far backward the possibility of meeting the animals<br />

bladder is given. This can cause false result because the urine reflects. If you are not sure, please repeat<br />

the test after the animal has drained its bladder.<br />