Instructions for using the heat detector<br />
The heat detector consists of a measuring box with a built-on probe made of plastic. For measuring the<br />
the electric resistance of the mucus of the uterus of cattle, 2 high sensitive ring electrodes are built-in the<br />
probe.<br />
In the measuring box, there is an indicating instrument for showing the value of ohm. To use the heat<br />
detector, push the two buttons below the indicating instrument.<br />
The button „EIN“ is used for the implementation of measurement and the button named „TEST“ is used<br />
in combination with the button „EIN“ for controlling the battery charging. The battery can be recharged<br />
with the built-in battery recharger by using the charging cable.<br />
1) Checking the battery:<br />
Please press both buttons („TEST“ and „EIN“) at the same time.<br />
If you see a needle deflection to 60 ohm the heat detector is ready. If the needle drops down under<br />
58 ohm, the battery of the heat detector for cattle has to be recharged for 10 hours on 220 v and 20<br />
hours on 110 v. The charging time of the heat detector for pigs takes 8 hours on 220 v and 14 hours<br />
on 110 v.<br />
2) Please clean the genital of the animal carefully before starting the measurement on the examined<br />
animal.<br />
3) The Vulva can be dried by using a tissue. Insert the probe into the vagina without using an antiblocking<br />
agent andtry to avoid any contamination of the probe. Our experience has shown us, that<br />
you will get reliable values, if you press the probe slightly to the bottom of the vagina nearby<br />
the cervix. The top has to be held down and then you have to press the button „EIN“ and the electric<br />
resistance will be shown.<br />
4) The shown value is an indicator for the stage of the heat. If the needle stays between 25-30 ohm,<br />
it shows that the heat has began. If the needle stays between 30 and 40 ohm, the animal is in the<br />
optimal time for insemination. This optimal time takes 6-8 hours in general, disregarding individual<br />
differences.If the needle goes over 40 ohm, the heat is at his end and in the most cases it is too late<br />
for a succesful insemination.<br />
5) The measurement can be assured by controlling and examining the ovary. A hard follicle on the<br />
ovary indicates, that it is too early for an insemination (measurement results 25-30 ohm). A soft and<br />
elastic follicle shows the optimal time for insemination (measurement results 30-40 ohm). This<br />
examination is definitively required, because the heat detector will also indicate the optimal time in<br />
heat (30-40 ohm), even if there are clearly tangible cysts on the ovary.<br />
6) If the value of the measurement is over 50 ohm, there can be an early pregnancy, if there was an<br />
insemination in advance.<br />
7) In the time without heat the values can also be about 50 ohm and more.<br />
8) After the measurement the probe has to be cleaned with warm water and disinfection liquid (for<br />
example 2% caustic lye of soda). Afterwards washing it up with cold water, drying it and disinfecting it<br />
with 70% alcohol. Then you can do the measurement on the next cow. This cleaning avoids any<br />
further infection from one animal to another.<br />
9) The electrodes should also be cleaned after several uses with alcohol and a disposable cloth.<br />