25.10.2014 Views

Animal identification Stock Breeding equipment Veterinary instruments

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Heat detector, Insemination <strong>instruments</strong>, Ultrasound units,<br />

Obstetric <strong>instruments</strong><br />

Heat detectors<br />

Heat detector<br />

with analog display for determination of the optimal time<br />

of insemination of sows, all heat detectors will be<br />

delivered in a bag for safe keeping.<br />

• saves on cost as there is no need for a second<br />

insemination<br />

• economic, makes it possible to identify the heat of<br />

difficult animals<br />

• easy handling as the probe only needs to be inserted<br />

into the vagina and after pushing the button the value<br />

of the ohm will be immediately displayed, this indicates<br />

the stage of the heat<br />

Heat detector<br />

for pigs, with 3 high sensitive ring electrodes,<br />

length of the sonde ca. 18 cm<br />

01612.000<br />

Heat detector for pigs<br />

For heat diagnosis in pigs by measuring the electric resistance of the mucus of the uterus. The correct<br />

and timely diagnosis is of great importance to the succes and efficiency of the farm. Especially, if there is<br />

artificial insemination used.<br />

0 - 30 ohm too early for insemination<br />

30 - 40 ohm optimal period (special marking)<br />

over 40 ohm too late for insemination<br />

The optimal time of insemination of pigs is between 30 and 40 ohm. If the value of ohm is under 30<br />

ohm, wait for a few hours and then repeat the measurement, for the accurate determination of the<br />

optimal time of insemination. If you get a value over 45 ohm, it is too late for<br />

insemination. You will need to wait until the next heat, in 3 weeks time, until you have the next optimal<br />

time for insemination. Whilst the heat detector gives an overview of the oestrus cycle, but the heat<br />

detector should only be used, when the sow is in standing oestrus. The heat detector can only be used if<br />

the sow shows acceptance reflex. In this situation it does not matter by which device this reflex is activated.<br />

Technical characteristics<br />

• Heat detector with built-in and rechargable battery for 230 V and charging cable<br />

• according to VDE instructions and double insulated<br />

• CE certificated<br />

• ambient temperature 0 - 40°C<br />

• electric shock protection class II<br />

• type IS, 110/220V, 3 VA, 47-60 Hz<br />

61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!