Heat detector, Insemination <strong>instruments</strong>, Ultrasound units,<br />
Obstetric <strong>instruments</strong><br />
Heat detectors<br />
Heat detector<br />
with analog display for determination of the optimal time<br />
of insemination of cattle, all heat detectors will be<br />
delivered in a bag for safe keeping.<br />
• saves on cost as there is no need for a second<br />
insemination<br />
• economic, makes it possible to identify the heat of<br />
difficult animals<br />
• easy handling as the probe only needs to be inserted<br />
into the vagina and after pushing the button the value<br />
of the ohm will be immediately displayed, this indicates<br />
the stage of the heat<br />
Heat detector<br />
for cattle, with 2 high sensitive ring electrodes,<br />
length of the sonde ca. 36 cm<br />
01610.000<br />
Heat detector for cattle<br />
For heat diagnosis of cattle by measuring the electric resistance of the mucus of the uterus. That the<br />
diagnosis is correct and provided on time is of great importance to the success and efficiency of a farm.<br />
Especially if artificial insemination is used.<br />
0 - 35 ohm too early for insemination<br />
35 - 40 ohm optimal period (special marking)<br />
over 40 ohm too late for insemination<br />
The optimal time of insemination of cattle is between 35 and 40 ohm, which is marked on the scale. By<br />
reaching this value, the cow is in the optimal period for insemination, which lasts for 6 - 8 hours. There<br />
can also be individual differences. If you get a value of 35 and 40 ohm the optimal time of insemination<br />
has been reached, the cow can now be artificially inseminated. It is also the optimal time for the mating.<br />
If the value of ohm is under 35 ohm, wait for a few hours and then repeat the measurement, for the<br />
accurate determination of the optimal time of insemination.<br />
If you get a value over 45 ohm, it is too late for insemination and you have to wait for the next period of<br />
heat.<br />
Technical characteristics<br />
• Heat detector with built-in and rechargable battery for 230 V and charging cable<br />
• according to VDE instructions and double insulated<br />
• CE certificated<br />
• ambient temperature 0 - 40°C<br />
• electric shock protection class II<br />
• type IS, 110/220V, 3 VA, 47-60 Hz<br />