Animal identification Stock Breeding equipment Veterinary instruments
Surgical and anatomic instruments, Meat inspection equipment Meat inspection equipment Meat inspection by artificial digestion method to discover trichines Magnet stirrer complete with heating 135 mm Ø, stirring rod of PTEE, magnet 40 mm long, stand rod V2A, thermometer holder and digital thermometer 0-150°C, cable ca. 65 cm long and socket 50202.000 Stirring rod remover 50203.000 Large glass 3 liter 50211.000 38 Glass separating funnel with glass plug valve, 2000 ml Glass plug valve 7 cm, Ø from 24 mm to 17 mm 50206.000 50206.010 Glisseal N grease for laboratories, for lubrication and sealing of stopcocks, suitable for vacuum -40°C bis +300°C, 60 g 50206.020 Plate stand with ring and double socket 50207.000 Glass funnel 15 cm Ø 50208.000 Pipette with ball, 30 ml 50209.000 Centrifuge tube 50 ml, graduated 50204.000 Metallic sieve according to DIN 4188, 18 mm opening, 100 mm Ø 50212.000 Bowl with net-work 1 x 1 cm, border height 2 cm, 9 cm Ø 50163.000 Chemical thermometer 20,5 cm long, 0,7 cm Ø Safety-pipette, 10 ml Magnet, 55 mm (triangular) 50213.000 50214.000 50201.020
Syringes, Needles and Blood-taking instruments „MUTO“ ® -Syringes easy handling because of ergonomic shape absolute exact dosification the adjusted dosage is going to be injected until the syringe is completely empty all parts are interchangeable with screw-on mount or Luer-Lock mount made of high-quality raw material „MUTO“ ® -syringe, Luer-Lock-mount adjustable dosages in ml 10 ml 0,25 - 0,5 - 0,75 - 1 16302.000 25 ml 0,5 - 1 - 1,5 - 2 - 2,5 16356.000 30 ml 1 - 2 - 3 - 4 - 5 16362.000 50 ml 1 - 2 - 3 - 4 - 5 16392.000 „MUTO“ ® -syringe, screw-on mount adjustable dosages in ml 10 ml 0,25 - 0,5 - 0,75 - 1 16300.000 25 ml 0,5 - 1 - 1,5 - 2 - 2,5 16355.000 30 ml 1 - 2 - 3 - 4 - 5 16360.000 50 ml 1 - 2 - 3 - 4 - 5 16390.000 Cleaning After finishing the vaccination and emptying the Muto syringe the cleaning of all parts is important. Rinse the syringe after the vaccination several times with hand-warm water, this means suck-in and inject out. The syringes are able to be boiled-out. One of the most important points to be considered is the emptying of the vaccine rests, which are not used during the vaccination, because some medicaments could react aggressively to the inside rubber plunger and the rubber washers. During time the rubber plungers can swell, especially after non- sufficient cleaning. In this case the use of the syringe can be harder and you would need more power to press the trigger. At this moment it is recommended to replace not only the rubber plunger, but all the other washers as well. All spare parts for example washer sets, glass barrels, ratchet with spring and screw, plunger rod (complete or single) are available individually and can be replaced easily by the owner. The well proved injection-system The flexible injection extension of Hauptner-Herberholz in combination with the MUTO-syringe enables an easy one-hand injection of animals. With your free hand it is now possible to mark the vaccinated animal. Due to the good quality material used it is possible to compensate the movement of the animal and to reduce breakage of needles considerably. (Injection extensions see page 42) 39
- Page 1: Edition no. 5 Animal identification
- Page 4 and 5: Since 1857 we have been successfull
- Page 6 and 7: Concentrated competence for your ad
- Page 8 and 9: Diagnostic instruments 8 Thermomete
- Page 10 and 11: Diagnostic instruments Specula Spec
- Page 12 and 13: Surgical and anatomic instruments,
- Page 14 and 15: Surgical and anatomic instruments,
- Page 16 and 17: Surgical and anatomic instruments,
- Page 18 and 19: Surgical and anatomic instruments,
- Page 20 and 21: Surgical and anatomic instruments,
- Page 22 and 23: Surgical and anatomic instruments,
- Page 24 and 25: Surgical and anatomic instruments,
- Page 26 and 27: Surgical and anatomic instruments,
- Page 28 and 29: Surgical and anatomic instruments,
- Page 30 and 31: Surgical and anatomic instruments,
- Page 32 and 33: Surgical and anatomic instruments,
- Page 34 and 35: Surgical and anatomic instruments,
- Page 36 and 37: Surgical and anatomic instruments,
- Page 40 and 41: Syringes, Needles and Blood-taking
- Page 42 and 43: Syringes, Needles and Blood-taking
- Page 44 and 45: Syringes, Needles and Blood-taking
- Page 46 and 47: Syringes, Needles and Blood-taking
- Page 48 and 49: Syringes, Needles and Blood-taking
- Page 50 and 51: Syringes, Needles and Blood-taking
- Page 52 and 53: Syringes, Needles and Blood-taking
- Page 54 and 55: Syringes, Needles and Blood-taking
- Page 56 and 57: Syringes, Needles and Blood-taking
- Page 58 and 59: Syringes, Needles and Blood-taking
- Page 60 and 61: Heat detector, Insemination instrum
- Page 62 and 63: Heat detector, Insemination instrum
- Page 64 and 65: Heat detector, Insemination instrum
- Page 66 and 67: Heat detector, Insemination instrum
- Page 68 and 69: Heat detector, Insemination instrum
- Page 70 and 71: Heat detector, Insemination instrum
- Page 72 and 73: Heat detector, Insemination instrum
- Page 74 and 75: Heat detector, Insemination instrum
- Page 76 and 77: Heat detector, Insemination instrum
- Page 78 and 79: Heat detector, Insemination instrum
- Page 80 and 81: Heat detector, Insemination instrum
- Page 82 and 83: Sexual organ instruments, Catheters
- Page 84 and 85: Sexual organ instruments, Catheters
- Page 86 and 87: Sexual organ instruments, Catheters
Syringes, Needles and Blood-taking <strong>instruments</strong><br />
„MUTO“ ® -Syringes<br />
easy handling because of ergonomic shape<br />
absolute exact dosification<br />
the adjusted dosage is going to be<br />
injected until the syringe is completely empty<br />
all parts are interchangeable<br />
with screw-on mount or Luer-Lock mount<br />
made of high-quality raw material<br />
„MUTO“ ® -syringe, Luer-Lock-mount<br />
adjustable dosages in ml<br />
10 ml 0,25 - 0,5 - 0,75 - 1 16302.000<br />
25 ml 0,5 - 1 - 1,5 - 2 - 2,5 16356.000<br />
30 ml 1 - 2 - 3 - 4 - 5 16362.000<br />
50 ml 1 - 2 - 3 - 4 - 5 16392.000<br />
„MUTO“ ® -syringe, screw-on mount<br />
adjustable dosages in ml<br />
10 ml 0,25 - 0,5 - 0,75 - 1 16300.000<br />
25 ml 0,5 - 1 - 1,5 - 2 - 2,5 16355.000<br />
30 ml 1 - 2 - 3 - 4 - 5 16360.000<br />
50 ml 1 - 2 - 3 - 4 - 5 16390.000<br />
Cleaning<br />
After finishing the vaccination and emptying the Muto syringe the cleaning of all parts is important. Rinse<br />
the syringe after the vaccination several times with hand-warm water, this means suck-in and inject out.<br />
The syringes are able to be boiled-out.<br />
One of the most important points to be considered is the emptying of the vaccine rests, which are not<br />
used during the vaccination, because some medicaments could react aggressively to the inside rubber<br />
plunger and the rubber washers.<br />
During time the rubber plungers can swell, especially after non- sufficient cleaning. In this case the use<br />
of the syringe can be harder and you would need more power to press the trigger. At this<br />
moment it is recommended to replace not only the rubber plunger, but all the other washers as well.<br />
All spare parts for example washer sets, glass barrels, ratchet with spring and screw, plunger rod<br />
(complete or single) are available individually and can be replaced easily by the owner.<br />
The well proved injection-system<br />
The flexible injection extension of Hauptner-Herberholz in combination with the MUTO-syringe enables an<br />
easy one-hand injection of animals. With your free hand it is now possible to mark the vaccinated animal.<br />
Due to the good quality material used it is possible to compensate the movement of the animal and to<br />
reduce breakage of needles considerably. (Injection extensions see page 42)<br />
39