<strong>Commuter</strong> <strong>Rail</strong> <strong>AC</strong> <strong>Electrification</strong> <strong>Load</strong>-<strong>Flow</strong> <strong>Simulation</strong> <strong>Report</strong> Revision 1<br />

APPENDIX A – TERMS AND ABBREVIATIONS ...................................................................... 37<br />

APPENDIX B – ALIGNMENT DATA, ROLLING STOCK DATA AND TRAIN OPERATION<br />

RESULTS ....................................................................................................................... 49<br />

APPENDIX C – ELECTRICAL RESULTS - ALL SYSTEMS IN SERVICE, TWO<br />

TRANSFORMERS IN SANDOWN SUBSTATION AND TWO TRANSFORMERS IN<br />

ARGO SUBSTATION ..................................................................................................... 71<br />

APPENDIX D – ELECTRICAL RESULTS - ARGO SUBSTATION OUT OF SERVICE, TWO<br />

TRANSFORMERS IN SANDOWN SUBSTATION AND TWO TRANSFORMERS IN<br />

ARGO SUBSTATION ..................................................................................................... 81<br />

APPENDIX E – ELECTRICAL RESULTS - SANDOWN SUBSTATION OUT OF SERVICE,<br />

TWO TRANSFORMERS IN SANDOWN SUBSTATION AND TWO TRANSFORMERS<br />

IN ARGO SUBSTATION ................................................................................................ 91<br />

APPENDIX F – ELECTRICAL RESULTS – ALL SYSTEMS IN SERVICE, TWO<br />

TRANSFORMERS IN SANDOWN SUBSTATION AND ONE TRANSFORMER IN<br />

ARGO SUBSTATION ................................................................................................... 101<br />

APPENDIX G – ELECTRICAL RESULTS - SANDOWN SUBSTATION OUT OF SERVICE,<br />

TWO TRANSFORMERS IN SANDOWN SUBSTATION AND ONE TRANSFORMER IN<br />

ARGO SUBSTATION ................................................................................................... 111<br />

APPENDIX H – RR INPUT DATA ............................................................................................ 121<br />

Tables<br />

Table 1 - Major Features of the <strong>Commuter</strong> <strong>Rail</strong> System to be Electrified ............................. 4<br />

Table 2 - 2x25 kV Autotransformer-Fed System Voltages ................................................. 17<br />

Table 3 - Ampacity of the Traction Power Distribution System ........................................... 17<br />

Table 4 - Rating of Transformers and Autotransformers .................................................... 19<br />

Table 5 - East Corridor Train Operation ............................................................................. 20<br />

Table 6 - Gold Line Train Operation ................................................................................... 20<br />

Table 7 - North Metro Corridor Train Operation.................................................................. 20<br />

Table 8 - Distribution System Impedances – Autotransformer-Fed System ....................... 21<br />

Table 9 - Distribution System Impedances – Direct-Fed System ....................................... 22<br />

Table 10 - System Voltages ................................................................................................. 23<br />

Table 11 -<br />

Conductor Ampacities and RMS Currents – All System In Service, Two<br />

Transformers in Sandown Substation, Two Transformers in Argo Substation .... 24<br />

Table 12 - Substation Transformer Power Demands – All System In Service ..................... 25<br />

Table 13 - Substation Transformer Power Demands – Argo Substation Outage ................. 25<br />

Table 14 - Substation Transformer Power Demands – Sandown Substation Outage .......... 26<br />

Table 15 -<br />

Table 16 -<br />

Table 17 -<br />

Autotransformer Power Demands – All Systems in Service, Two Transformers in<br />

Sandown Substation, Two Transformers in Argo Substation .............................. 27<br />

Traction Power System Facilities, Autotransformer-Fed System, 2 Transformers<br />

in Sandown Substation, 2 Transformers in Argo Substation ............................... 31<br />

Traction Power System Facilities, Autotransformer-Fed System, 2 Transformers<br />

in Sandown Substation, 1 Transformer in Argo Substation ................................. 32<br />

Figures<br />

Figure 1 - FasTracks Corridor Alignments ............................................................................. 5<br />

Figure 2 - Overall Electrical System Arrangement – Two Transformers in Sandown<br />

Substation and Two Transformers in Argo Substation ........................................ 33<br />

Figure 3 - Overall Electrical System Arrangement – Two Transformers in Sandown<br />

Substation and One Transformer in Argo Substation .......................................... 34<br />

Figure 4 - Car Data .............................................................................................................. 60<br />

Figure 5 - Tractive Effort, Line Current, and Train Resistance Curves ................................ 61<br />

02/27/2009 FRSC Table of Contents