FutureComTM S/FTP 550/23s LS0H-1 Cat. 6A Cable Application ...
FutureComTM S/FTP 550/23s LS0H-1 Cat. 6A Cable Application ... FutureComTM S/FTP 550/23s LS0H-1 Cat. 6A Cable Application ...
Technical Product Datasheet CCXEDR-D00xx-C003-xx / February 2009 Type designation Category Copper conductor Number of pairs Fire rating (MJ/m) Halogenfree Tensile strength for installation [N] Outside-ø [mm] S/FTP 550/23s 4P LSZH-1 6A AWG 23 4 0.50 yes 145 7.0 48 S/FTP 550/23s 8P LSZH-1 6A AWG 23 8 1.03 yes 290 7.0 x 15.5 96 Crush resistance according to EN 50289-3-5: 1000 N/100mm/1 min (electrical characteristics according to EN 50288-5-1 are kept). Electrical Characteristics @ 20°C Weight [kg/km] Frequency in MHz 1 10 16 20 31.25 62.5 100 250 500 550 Attenuation in dB/100 m per standard* 2.1 5.9 7.5 8.4 10.5 15.0 19.1 31.1 45.3 - Typical values dB/100 m 1.8 5.3 6.8 7.6 9.6 13.6 17.3 27.7 41.9 42.6 Near-end crosstalk loss in dB per standard* 75.3 60.3 57.2 55.8 52.9 48.4 45.3 39.3 34.8 Typical values dB/100 m >100 >100 >100 >100 >100 97 95 90 83 77 PSNEXT in dB/100 m per standard* 72.3 57.3 54.2 52.8 49.9 45.4 42.3 36.3 31.8 - Typical values dB/100 m 98 98 98 98 98 95 93 88 81 75 ACR-F in dB/100 m per standard* (old: ELFEXT) 68.0 48.0 43.9 42.0 38.1 32.1 28.0 20.0 14.0 - Typical values dB/100 m 93 93 93 93 90 86 83 70 57 51 PS ACR-F in dB/100 m per standard* (old: PSELFEXT) 65.0 45.0 40.9 39.0 35.1 29.1 25.0 17.0 11.0 - Typical values dB/100 m 90 90 90 90 87 83 80 67 54 48 ACR-N in dB/100m per standard* (old: ACR) 73.2 54.4 49.8 47.4 42.4 33.4 26.2 8.3 -10.4 - Typical values (ACR-N) in dB/100m 98.2 94.7 93.2 92.4 90.4 83.4 77.7 62.3 41.1 34.4 *) Standard: Requirements on 100 m installed Category 6 A cable (corresponds to ISO/IEC 61156-5 (Draft 2006) • Max. loop resistance: 165 /km • Max. resistance difference: 1% • Insulation resistance: > 5000 M x km • Impedance Z 0 @ 0.064 MHz: 125 ± 20% • Impedance Z 0 @ 1 up to 100 MHz: 100 ± 15% • Impedance Z 0 @ 101 up to 250 MHz: 100 ± 18% • Transfer impedance: < 100 m per meter at 10 MHz • Longitudinal conversion loss dB/ref. Length = 1000 m: > 46 dB @ 64 kHz • Longitudinal conversion loss dB/ref. Length = 100 m: > 40 dB @ 1 MHz • Longitudinal conversion loss dB/ref. Length = 100 m: > 20 dB @ 100 MHz • Mutual capacity: 43 pF/m • Max. capacitance @ 0.001 MHz: 1000 pF/km • Propagation velocity > 10 MHz ( NVP * c ): 0.79 c • Propagation delay > 10 MHz: 4.2 ns/m; Skew: 4 ns/100m Mechanical Characteristics Wire insulation: Zero halogen foam/skin material Sheath material: Zero halogen. flame-retardant Deployment area: Dry and damp rooms Max. temperature range during installation: 0°C up to +50 °C Max. operating temperature: -20 up to +60°C Min. bend radius in service: 21 mm (over flat side) Min. bend radius during installation: 60 mm (over flat side) Corning Cable Systems GmbH & Co. KG · Leipziger Strasse 121 · 10117 Berlin, Germany TEL: 00800-2676-4641 (00800-CORNING1) · FAX: +49-30-5303-2335 · www.corningcablesystems.com Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU.
Technical Product Datasheet CCXEDR-D00xx-C003-xx / February 2009 Ordering Information Type designation S/FTP 550/23s 4P LSZH-1 S/FTP 550/23s 8P LSZH-1 Delivery 1000m 500m Ordering number CCXEDR-D0047-C003-L7 CCXEDR-D0087-C003-L6 Corning Cable Systems GmbH & Co. KG · Leipziger Strasse 121 · 10117 Berlin, Germany TEL: 00800-2676-4641 (00800-CORNING1) · FAX: +49-30-5303-2335 · www.corningcablesystems.com Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ products without prior notification. LANscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. © 2009 Corning Cable Systems. All rights reserved. Published in the EU.
Technical Product Datasheet<br />
CCXEDR-D00xx-C003-xx / February 2009<br />
Type designation<br />
<strong>Cat</strong>egory<br />
Copper<br />
conductor<br />
Number<br />
of pairs<br />
Fire rating<br />
(MJ/m)<br />
Halogenfree<br />
Tensile<br />
strength for<br />
installation [N]<br />
Outside-ø<br />
[mm]<br />
S/<strong>FTP</strong> <strong>550</strong>/<strong>23s</strong> 4P LSZH-1 <strong>6A</strong> AWG 23 4 0.50 yes 145 7.0 48<br />
S/<strong>FTP</strong> <strong>550</strong>/<strong>23s</strong> 8P LSZH-1 <strong>6A</strong> AWG 23 8 1.03 yes 290 7.0 x 15.5 96<br />
Crush resistance according to EN 50289-3-5: 1000 N/100mm/1 min (electrical characteristics according to EN 50288-5-1 are kept).<br />
Electrical Characteristics @ 20°C<br />
Weight<br />
[kg/km]<br />
Frequency in MHz 1 10 16 20 31.25 62.5 100 250 500 <strong>550</strong><br />
Attenuation in dB/100 m per standard* 2.1 5.9 7.5 8.4 10.5 15.0 19.1 31.1 45.3 -<br />
Typical values dB/100 m 1.8 5.3 6.8 7.6 9.6 13.6 17.3 27.7 41.9 42.6<br />
Near-end crosstalk loss in dB per standard* 75.3 60.3 57.2 55.8 52.9 48.4 45.3 39.3 34.8<br />
Typical values dB/100 m >100 >100 >100 >100 >100 97 95 90 83 77<br />
PSNEXT in dB/100 m per standard* 72.3 57.3 54.2 52.8 49.9 45.4 42.3 36.3 31.8 -<br />
Typical values dB/100 m 98 98 98 98 98 95 93 88 81 75<br />
ACR-F in dB/100 m per standard*<br />
(old: ELFEXT)<br />
68.0 48.0 43.9 42.0 38.1 32.1 28.0 20.0 14.0 -<br />
Typical values dB/100 m 93 93 93 93 90 86 83 70 57 51<br />
PS ACR-F in dB/100 m per standard*<br />
(old: PSELFEXT)<br />
65.0 45.0 40.9 39.0 35.1 29.1 25.0 17.0 11.0 -<br />
Typical values dB/100 m 90 90 90 90 87 83 80 67 54 48<br />
ACR-N in dB/100m per standard*<br />
(old: ACR)<br />
73.2 54.4 49.8 47.4 42.4 33.4 26.2 8.3 -10.4 -<br />
Typical values (ACR-N) in dB/100m 98.2 94.7 93.2 92.4 90.4 83.4 77.7 62.3 41.1 34.4<br />
*) Standard: Requirements on 100 m installed <strong>Cat</strong>egory 6 A cable (corresponds to ISO/IEC 61156-5 (Draft 2006)<br />
• Max. loop resistance: 165 /km<br />
• Max. resistance difference: 1%<br />
• Insulation resistance: > 5000 M x km<br />
• Impedance Z 0 @ 0.064 MHz: 125 ± 20%<br />
• Impedance Z 0 @ 1 up to 100 MHz: 100 ± 15%<br />
• Impedance Z 0 @ 101 up to 250 MHz: 100 ± 18%<br />
• Transfer impedance: < 100 m per meter at 10 MHz<br />
• Longitudinal conversion loss dB/ref. Length = 1000 m: > 46 dB @ 64 kHz<br />
• Longitudinal conversion loss dB/ref. Length = 100 m: > 40 dB @ 1 MHz<br />
• Longitudinal conversion loss dB/ref. Length = 100 m: > 20 dB @ 100 MHz<br />
• Mutual capacity: 43 pF/m<br />
• Max. capacitance @ 0.001 MHz: 1000 pF/km<br />
• Propagation velocity > 10 MHz ( NVP * c ): 0.79 c<br />
• Propagation delay > 10 MHz: 4.2 ns/m; Skew: 4 ns/100m<br />
Mechanical Characteristics<br />
Wire insulation: Zero halogen foam/skin material<br />
Sheath material: Zero halogen. flame-retardant<br />
Deployment area: Dry and damp rooms<br />
Max. temperature range during installation: 0°C up to +50 °C<br />
Max. operating temperature: -20 up to +60°C<br />
Min. bend radius in service: 21 mm (over flat side)<br />
Min. bend radius during installation: 60 mm (over flat side)<br />
Corning <strong>Cable</strong> Systems GmbH & Co. KG · Leipziger Strasse 121 · 10117 Berlin, Germany<br />
TEL: 00800-2676-4641 (00800-CORNING1) · FAX: +49-30-5303-2335 · www.corningcablesystems.com<br />
Corning <strong>Cable</strong> Systems reserves the right to improve, enhance and modify the features and specifications of Corning <strong>Cable</strong> Systems’ products without prior<br />
notification. LANscape is a registered trademark of Corning <strong>Cable</strong> Systems Brands, Inc. All other trademarks are the properties of their respective owners.<br />
Corning <strong>Cable</strong> Systems is ISO 9001 certified. © 2009 Corning <strong>Cable</strong> Systems. All rights reserved. Published in the EU.