C.D. Deakin et al. / <strong>Resuscitation</strong> 81 (<strong>2010</strong>) 1305–1352 1327<br />

<strong>for</strong> in-hospital cardiac arrest, 537,538 but another showed no survival<br />

advantage. 539<br />

Active compression-decompression CPR (ACD-CPR)<br />

ACD-CPR is achieved with a hand-held device equipped with a<br />

suction cup to lift the anterior chest actively during decompression.<br />

Decreasing intrathoracic pressure during the decompression phase<br />

increases venous return to the heart and increases cardiac output<br />

and subsequent coronary and cerebral perfusion pressures during<br />

the compression phase. 540–543 Results of ACD-CPR have been<br />

mixed. In some clinical studies ACD-CPR improved haemodynamics<br />

compared with standard CPR, 541,543–545 but in another study it did<br />

not. 546 In three randomised studies, 545,547,548 ACD-CPR improved<br />

long-term survival after out-of-hospital cardiac arrest; however,<br />

in five other randomised studies, ACD-CPR made no difference to<br />

outcome. 549–553 The efficacy of ACD-CPR may be highly dependent<br />

on the quality and duration of training. 554<br />

A meta-analysis of 10 trials of out-of-hospital cardiac arrest and<br />

two of in-hospital cardiac arrest showed no early or late survival<br />

benefit to ACD-CPR over conventional CPR. 205 Two post-mortem<br />

studies have shown more rib and sternal fractures after ACD-<br />

CPR compared with conventional CPR, 555,556 but another found no<br />

difference. 557<br />

Impedance threshold device (ITD)<br />

The impedance threshold device (ITD) is a valve that limits<br />

air entry into the lungs during chest recoil between chest<br />

compressions; this decreases intrathoracic pressure and increases<br />

venous return to the heart. When used with a cuffed tracheal tube<br />

and active compression–decompression (ACD), 558–560 the ITD is<br />

thought to act synergistically to enhance venous return during<br />

active decompression. The ITD has also been used during conventional<br />

CPR with a tracheal tube or facemask. 561 If rescuers can<br />

maintain a tight face-mask seal, the ITD may create the same negative<br />

intrathoracic pressure as when used with a tracheal tube. 561<br />

Most, 562–569 but not all, 570–573 animal studies have shown<br />

improved haemodynamics or outcomes during CPR when using the<br />

device. Several randomised trials have shown differing results. Two<br />

trials suggest that the use of an ITD in combination with ACD-CPR<br />

improves 24 h survival and survival to ICU admission in adult OHCA<br />

patients, 560,574 but these contrast with others which failed to show<br />

any improvement in ROSC or 24 h survival. 558,561 A recent metaanalysis<br />

demonstrated improved ROSC and short-term survival but<br />

no significant improvement in either survival to discharge or neurologically<br />

intact survival to discharge associated with the use of an<br />

ITD in the management of adult OHCA patients. 575 In the absence of<br />

data showing that the ITD increases survival to hospital discharge,<br />

its routine use in cardiac arrest is not recommended.<br />

Mechanical piston CPR<br />

Mechanical piston devices depress the sternum by means of<br />

a compressed gas-powered plunger mounted on a backboard. In<br />

several studies in animals, 576 mechanical piston CPR improved<br />

end-tidal carbon dioxide, cardiac output, cerebral blood flow, MAP<br />

and short-term neurological outcome. Studies in humans also document<br />

improvement in end-tidal carbon dioxide and mean arterial<br />

pressure when using mechanical piston CPR compared with conventional<br />

CPR. 577–579 One study has documented that the use of a<br />

piston CPR device compared with manual CPR increases interruption<br />

in CPR due to setting up and removal of the device from patients<br />

during transportation in out-of-hospital adult cardiac arrest. 580<br />

Lund University cardiac arrest system (LUCAS) CPR<br />

The Lund University cardiac arrest system (LUCAS) is a gasdriven<br />

sternal compression device that incorporates a suction cup<br />

<strong>for</strong> active decompression. Although animal studies showed that<br />

LUCAS-CPR improves haemodynamic and short-term survival compared<br />

with standard CPR. 581,582 There are no published randomised<br />

human studies comparing LUCAS-CPR with standard CPR. A study<br />

using LUCAS <strong>for</strong> witnessed OHCA was unable to show any benefit<br />

(ROSC, survival to hospital or survival to hospital discharge)<br />

over standard CPR. 583 Case series totalling 200 patients have<br />

reported variable success in use of the LUCAS device, when implemented<br />

after an unsuccessful period of manual CPR. 347,581,584–586<br />

One case series used LUCAS to per<strong>for</strong>m CPR while PCI was being<br />

per<strong>for</strong>med. 293 Eleven of 43 patients survived to hospital discharge<br />

neurologically intact. There are several other reports documenting<br />

use of LUCAS during PCI. 585,587,588 One post-mortem study showed<br />

similar injuries with LUCAS compared with standard CPR. 589 The<br />

early versions of the LUCAS device which were driven by high flow<br />

oxygen (LUCAS TM 1) should not be used in confined spaces where<br />

defibrillation in high ambient oxygen concentrations may risk a<br />

fire. 590<br />

Load-distributing band CPR (AutoPulse)<br />

The load-distributing band (LDB) is a circumferential chest compression<br />

device comprising a pneumatically actuated constricting<br />

band and backboard. Although the use of LDB CPR improves<br />

haemodynamics, 591–593 results of clinical trials have been conflicting.<br />

Evidence from one multicenter randomised control trial<br />

in over 1000 adults documented no improvement in 4-h survival<br />

and worse neurological outcome when LDB-CPR was used<br />

by EMS providers <strong>for</strong> patients with primary out-of-hospital cardiac<br />

arrest. 594 However, a post hoc analysis of this study revealed<br />

significant heterogeneity between study sites. 598 A further study<br />

demonstrated lower odds of 30-day survival (OR 0.4) but subgroup<br />

analysis showed an increased rate of ROSC in LDB-CPR treated<br />

patients. 595 Other non-randomised human studies have reported<br />

increased rates of sustained ROSC, 596,597 increased survival to discharge<br />

following OHCA 597 and improved hemodynamics following<br />

failed resuscitation from in-hospital cardiac arrest. 591 Evidence<br />

from both clinical 594,598 and simulation 599 studies suggest that sitespecific<br />

factors may influence resuscitation quality and efficacy of<br />

this device.<br />

The current status of LUCAS and AutoPulse<br />

Two large prospective randomised multicentre studies are currently<br />

underway to evaluate the load-distributing band (AutoPulse)<br />

and the Lund University cardiac arrest system (LUCAS). The<br />

results of these studies are awaited with interest. In hospital,<br />

mechanical devices have been used effectively to support<br />

patients undergoing primary coronary intervention (PCI) 293,585<br />

and CT scans 600 and also <strong>for</strong> prolonged resuscitation attempts<br />

(e.g., hypothermia, 601,602 poisoning, thrombolysis <strong>for</strong> pulmonary<br />

embolism, prolonged transport, etc.) where rescuer fatigue may<br />

impair the effectiveness of manual chest compression. In the prehospital<br />

environment where extrication of patients, resuscitation<br />

in confined spaces and movement of patients on a trolley often<br />

preclude effective manual chest compressions, mechanical devices<br />

may also have an important role. During transport to hospital, manual<br />

CPR is often per<strong>for</strong>med poorly; mechanical CPR can maintain<br />

good quality CPR during an ambulance transfer. 343,603 Mechanical<br />

devices also have the advantage of allowing defibrillation without<br />

interruption in external chest compression. The role of mechanical<br />

devices in all situations requires further evaluation.