T8 Manual - UMS
T8 Manual - UMS T8 Manual - UMS
Appendix Configuration of T8 Tensiometer cable and plug: Wiring connections Signal Wire Pin Function V in white 1 Supply +6…+18 V DC GND brown 2 Supply minus A-OUT+1 green 3 Analog output 1 (pressure) A-OUT- yellow 4 Analog minus digital OUT grey 5 Filling status (max. supply voltage), some loggers need a voltage divider! 8-pin male plug RS485-A pink 6 RS485-A 2-wire RS485-B blue 7 RS485-B 2-wire A-OUT+2 / SDI12 red 8 Analog output 2 (temperature) or SDI12 Configuration of the USB converter: USB converter plug configuration Signal Pin Function V out 1 Supply +7…+10 V DC GND 2 Supply minus n.c. 3 - n.c. 4 - n.c. 5 - RS485-A 6 RS485-A 2-wire RS485-B 7 RS485-B 2-wire n.c. 8 - 8-pin female plug 50/56
Appendix 9.3 Accessories 9.3.1 Connecting and extension cables Cables must be ordered additionally for each Tensiometer. UMS connecting or extension cables for data logger applications etc. Connecting cables CC-8/... are fitted with a female plug M12/IP67 and 12 cm wire end sleeves. Extension cables EC-8/... have one each male and female plug M12/IP67. Plugs are supplied with protective caps. Item 8-pin connection cable for T8 Length 1,5 m Length 5 m Length 10 m Length 20 m Length 30 m 8-pin extension cable for T8 Length 5 m Length 10 m Length 20 m Additional items Clip-on cable markers, 30 times numbers 0 ... 9 Art. no. CC-8/1.5 CC-8/5 CC-8/10 CC-8/20 CC-8/30 EC-8/5 EC-8/10 EC-8/20 Art. no. KMT Plastic protection tube for cables are available with several diameters, also dividable slotted tubes for easy re-fitting. 51/56
- Page 1 and 2: User Manual T8 Long-term Monitoring
- Page 3 and 4: Tensiometer T8 3.5.4 Connecting the
- Page 5 and 6: Tensiometer T8 1.2 Content of deliv
- Page 7 and 8: Tensiometer T8 Soil water and Tensi
- Page 9 and 10: Tensiometer T8 External syringe ref
- Page 11 and 12: Description of the T8 2 Description
- Page 13 and 14: Description of the T8 2.2 Output si
- Page 15 and 16: Description of the T8 2.4 Software
- Page 17 and 18: Installation • Lightning: cables
- Page 19 and 20: Installation 3.2.1 "Vertical" with
- Page 21 and 22: Installation 4. Connect the Tensiom
- Page 23 and 24: Installation 3.5 Connecting T8 3.5.
- Page 25 and 26: T8 configuration with tensioVIEW®
- Page 27 and 28: T8 configuration with tensioVIEW®
- Page 29 and 30: T8 configuration with tensioVIEW®
- Page 31 and 32: T8 configuration with tensioVIEW®
- Page 33 and 34: T8 configuration with tensioVIEW®
- Page 35 and 36: Service and maintenance If the soil
- Page 37 and 38: Service and maintenance With this m
- Page 39 and 40: Service and maintenance Remove the
- Page 41 and 42: Protecting the measuring site 6 Pro
- Page 43 and 44: Protecting the measuring site Gener
- Page 45 and 46: Useful notes If there will be rain
- Page 47 and 48: Troubleshooting 7.5 Using a T8 as a
- Page 49: Appendix Optional settings* Output
- Page 53 and 54: Appendix 9.3.4 Refill kits BKTex Re
- Page 55 and 56: Appendix 55/56
Appendix<br />
9.3 Accessories<br />
9.3.1 Connecting and extension cables<br />
Cables must be ordered additionally for each Tensiometer.<br />
<strong>UMS</strong> connecting or extension cables for data logger applications etc.<br />
Connecting cables CC-8/... are fitted with a female plug M12/IP67<br />
and 12 cm wire end sleeves.<br />
Extension cables EC-8/... have one each male and female plug<br />
M12/IP67.<br />
Plugs are supplied with protective caps.<br />
Item<br />
8-pin connection cable for <strong>T8</strong><br />
Length 1,5 m<br />
Length 5 m<br />
Length 10 m<br />
Length 20 m<br />
Length 30 m<br />
8-pin extension cable for <strong>T8</strong><br />
Length 5 m<br />
Length 10 m<br />
Length 20 m<br />
Additional items<br />
Clip-on cable markers, 30 times numbers 0 ... 9<br />
Art. no.<br />
CC-8/1.5<br />
CC-8/5<br />
CC-8/10<br />
CC-8/20<br />
CC-8/30<br />
EC-8/5<br />
EC-8/10<br />
EC-8/20<br />
Art. no.<br />
KMT<br />
Plastic protection tube for cables are available with several diameters, also<br />
dividable slotted tubes for easy re-fitting.<br />
51/56