Appendix<br />

9 Appendix<br />

9.1 Technical specifications<br />

Material and dimensions<br />

Ceramic material<br />

Ceramic dimensions<br />

Housing material<br />

Shaft material<br />

Sensor cable<br />

For shaft lengths < 120 cm<br />

For shaft lengths > 121 cm<br />

Plug<br />

Measuring range*<br />

Pressure transducer<br />

Al2O3 sinter, bubble point > 15 bar<br />

Length 60 mm, ∅ 24 mm<br />

PA6 GF30<br />

Impact-proof PMMA, ∅ 25 mm<br />

Length 1,5 m from sensor body (effective<br />

length = 1,5 m minus shaft length)<br />

Length 0,6 m from end of shaft<br />

Male 8-pin, thread M12, IP67<br />

-100 kPa ... +100 kPa (electronically)<br />

-85 kPa ... +100 kPa (physically)<br />

Water tension -85 kPa … 0 kPa (Tensiometer)<br />

Water level 0 kPa … +100 kPa (Piezometer)<br />

Temperature -30 °C ... +70 °C<br />

Standard output signals*<br />

Pressure<br />

0 ... 2 V = +100 kPa ... -100 kPa<br />

Temperature 0 ... 2 V = -30 ... +70 °C<br />

IR-indicator<br />

Switch open: filling OK<br />

Switch closed: signal = V in; refilling required<br />

(max. burden 50 mA)<br />

Accuracy<br />

(raw signals)<br />

Pressure transducer<br />

Temperature probe<br />

Power supply<br />

Supply voltage V in<br />

Current consumption<br />

±0,5 kPa<br />

±0,2 K (-10...+30 °C); ±0,4 K (-30...+60 °C)<br />

6 ... 18 V DC<br />

3 mA nominal, (max. 20 mA)<br />