Installation<br />

• Rule, spirit level, angle gauge, marker pen.<br />

• Minute book, camera for documentation of site and soil profile.<br />

• Perhaps PE-plastic bags for taking soil samples from the site.<br />

• Thermal insulation tubes for installations from soil surface.<br />

• Cable protection tubes.<br />

• Jacket tubes if required (inner diameter > 35 mm).<br />

Please observe the following notes:<br />

Do not touch the cup with your fingers. The ceramic should not<br />

have contact with grease or soap as this will influence the<br />

hydrophilic performance.<br />

Do not leave the cup in air for more than 5 minutes as<br />

Tensiometer water will evaporate and the Tensiometer will need to<br />

be refilled.<br />

Procedure:<br />

1. Mark the required drilling depth on auger and Tensiometer shaft.<br />

The reference point is the center of the cup. Drill a hole with the<br />

desired depth on the chosen measuring spot. Auger stepwise<br />

and take care when drilling the last 20 cm, remove and save this<br />

soil. Water will not run along the shaft if the Tensiometer is<br />

installed in an angle because the water will drain into the soil<br />

before it reaches the cup.<br />

Read the chapter "Selecting the installation position" for the best<br />

installation angle.<br />

2. When using augers with a diameter of over 25 mm, mix a paste<br />

of water and crumbled soil material taken out of the borehole. Fill<br />

the paste into the bottom area of the borehole by using a simple<br />

pipe with outer diameter 2 cm.<br />

3. Now take off the protective plastic cap from the Tensiometer cup.<br />

Important: Do not turn, but pull when taking the bottle off - and<br />

also when putting it back on again!<br />

Save the plastic bottles: Do not store the Tensiometer without the<br />

protective plastic bottle since the cup drains fast! The bottle must<br />

be filled with some water for storage!<br />