18.10.2014 Views

Rectifiers

Rectifiers

Rectifiers

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

World Class Power Solutions<br />

<strong>Rectifiers</strong><br />

for stationary battery systems<br />

Range ADC II


ADC II<br />

General<br />

his rectifier range is suitable for boost and float-charging<br />

T of stationary installations. The low power ranges, are also<br />

suitable for charging starter-batteries for diesel motors or gas<br />

turbines.<br />

Integrated function<br />

he ADC is equipped with an active filter for sinusoidal<br />

T current consumption on the mains input. Using this technology<br />

a power factor of nearly 1 can be reached. This means<br />

that only actual power is taken from the supply to feed the ADC.<br />

Because the ADC has a very low output ripple current, it is ideally<br />

suited to be used with sealed batteries. The ADC can also be<br />

connected to loads without batteries because of its excellent<br />

dynamic performance.<br />

These units can be supplied in a 19" plug-in version (see picture<br />

1), as module (see picture 2) or in a wall-mounted version<br />

(see picture 3).<br />

The output is accurate, with constant power characteristic and<br />

equipped with 3 different voltage levels as well as a current<br />

limiting.<br />

For optimizing the battery service life of sealed batteries temperature<br />

compensated charging voltage regulation is possible.<br />

The unit is cooled with a fan which is temperature controlled<br />

and superviced by a max. temperature guard.<br />

Picture 1: 19“-plug in<br />

Picture 2: Module<br />

TECHNICAL DATA<br />

AC-input<br />

• Input voltage:<br />

• Power factor:<br />

• Efficiency:<br />

• mains input fuse<br />

• soft start<br />

230V ± 15 %, 47 - 63 Hz<br />

> 0,98 at nom. load<br />

82 - 90 % depending on<br />

the output voltage<br />

Monitoring functions<br />

• mains fault<br />

• rectifier fault<br />

•<br />

• fuse alarm<br />

• over temperature alarm<br />

monitoring of the adjusted constant voltage<br />

battery temperature monitoring with compensation charging<br />

(temperature sensor necessary)<br />

DC-output<br />

• 4 possible output voltages<br />

• constant power characteristic with current limiting<br />

• output voltage accuracy < 0,5 %<br />

• ripple<br />

< 0,05 % eff<br />

• phosmetric noise voltage ≤ 1 bzw 2 mV acc.to CCITT<br />

•<br />

• short-circuit-proof<br />

parallel switchable<br />

• blockable equalizing<br />

• automatic charging possible<br />

• output relay for "power failure"<br />

• output relay for "common alarm"<br />

Standard display CL 20 (see picture 4)<br />

The display unit is microprossesor controlled and supplied via<br />

DC-DC-converter from the output voltage during mains failure<br />

from the battery.<br />

• push button for ON/OFF with LED indication<br />

• push button for boost with LED indication<br />

• push button for reset<br />

• LCD display with push button and LED’s for indication of output<br />

voltage and current also the adjusted limits<br />

• LED "operation"<br />

• LED "Failure"<br />

• LED "voltage deviation"


ADC II<br />

Picture 3: Wall mounted cabinet<br />

Standard-displays<br />

Picture 4: Standard display CL 20 Picture 5: Monitor unit CL 30 and CL 40<br />

TECHNICAL DATA<br />

Monitor unit CL 30 (see picture 5)<br />

• The monitor unit CL 30 provides the following indications, in<br />

addition to those of the CL 20.<br />

- charge level high<br />

(varibale adjustment from 110-130% of nominal voltage)<br />

- charge level low<br />

(varibale adjustment from 90-110 % of nominal voltage)<br />

- battery circuit failure<br />

(daily automatic detection of a fault within the battery<br />

circuit and a button for manual test)<br />

- battery test<br />

(variable adjustment for time and low voltage limit)<br />

- Earth fault monitoring +/-<br />

(adjustable from 0,1 up to 1 MOhm)<br />

All monitoring functions can be individually delayed, and are linked<br />

to the common alarm relay and indicated via LED.<br />

CL 40 option<br />

This provides all the monitoring functions of the CL 30 via individual<br />

volt free relay. The relay card is connected via an I 2 C-bus.<br />

Relevant standards<br />

• EN 60950<br />

• EN 50081-1<br />

• EN-50082-2<br />

Ambient conditions and mechanical details<br />

• ambient temperature max 40 °C<br />

• Installation height<br />

max. 1000 m ab. sea level<br />

• Rel.humidity: < 95%<br />

• Acustic noise<br />

< 40 dB in 1 m distance<br />

• Protection IP 20<br />

• Dimensions<br />

• Paint finish<br />

with fan oper. < 55 dB<br />

in 1 m distance<br />

see type table<br />

- Module: Galvanised<br />

- Cabinet: RAL 7035<br />

- 19“ plug in: front panel RAL 7035


ADC II<br />

Typetable ADC II range<br />

MODULE VERSION<br />

Type Input voltage Input current Output voltage Output current Dimensions Weight<br />

( V ) ( A ) ( V ) ( A ) H x W x D kg<br />

E 230 G 12/ 20 BWru - ADC/M 230 0,9 12 20 190 x 250 x 170 5<br />

E 230 G 24/ 12 BWru - ADC/M 230 1,6 24 12 190 x 250 x 170 5<br />

E 230 G 24/ 20 BWru - ADC/M 230 3,2 24 20 190 x 250 x 170 6<br />

E 230 G 48/ 6 BWru - ADC/M 230 1,6 48 6 190 x 250 x 170 5<br />

E 230 G 48/ 12 BWru - ADC/M 230 3,2 48 12 190 x 250 x 170 6<br />

E 230 G 60/ 4,8 BWru - ADC/M 230 1,6 60 4,8 190 x 250 x 170 5<br />

E 230 G 60/ 9,5 BWru - ADC/M 230 3,2 60 9,5 190 x 250 x 170 6<br />

E 230 G 110/ 5,2 BWru - ADC/M 230 3,2 110 5,2 190 x 250 x 170 6<br />

CABINET VERSION<br />

Type Input voltage Input current Output voltage Output current Dimensions Weight<br />

( V ) ( A ) ( V ) ( A ) H x W x D kg<br />

E 230 G 12/ 20 BWru - ADC/G 230 0,9 12 20 410 x 275 x 190 9<br />

E 230 G 24/ 12 BWru - ADC/G 230 1,6 24 12 410 x 275 x 190 9<br />

E 230 G 24/ 20 BWru - ADC/G 230 3,2 24 20 410 x 275 x 190 10<br />

E 230 G 48/ 6 BWru - ADC/G 230 1,6 48 6 410 x 275 x 190 9<br />

E 230 G 48/ 12 BWru - ADC/G 230 3,2 48 12 410 x 275 x 190 10<br />

E 230 G 60/ 4,8 BWru - ADC/G 230 1,6 60 4,8 410 x 275 x 190 9<br />

E 230 G 60/ 9,5 BWru - ADC/G 230 3,2 60 9,5 410 x 275 x 190 10<br />

E 230 G 110/ 5,2 BWru - ADC/G 230 3,2 110 5,2 410 x 275 x 190 10<br />

19“PLUG IN VERSION<br />

Type Input voltage Input current Output voltage Output current Dimensions Weight<br />

( V ) ( A ) ( V ) ( A ) H x W x D kg<br />

E 230 G 12/ 20 BWru - ADC/E 230 0,9 12 20 89 x 483 x 240 5<br />

E 230 G 24/ 12 BWru - ADC/E 230 1,6 24 12 89 x 483 x 240 5<br />

E 230 G 24/ 20 BWru - ADC/E 230 3,2 24 20 89 x 483 x 240 6<br />

E 230 G 48/ 6 BWru - ADC/E 230 1,6 48 6 89 x 483 x 240 5<br />

E 230 G 48/ 12 BWru - ADC/E 230 3,2 48 12 89 x 483 x 240 6<br />

E 230 G 60/ 4,8 BWru - ADC/E 230 1,6 60 4,8 89 x 483 x 240 5<br />

E 230 G 60/ 9,5 BWru - ADC/E 230 3,2 60 9,5 89 x 483 x 240 6<br />

E 230 G 110/ 5,2 BWru - ADC/E 230 3,2 110 5,2 89 x 483 x 240 6<br />

DIMENSION DIAGRAMS<br />

Wall mounted cabinet<br />

Module version<br />

ø 5,5 (4x)<br />

ø 10 (2x)<br />

37<br />

37<br />

300<br />

220<br />

250<br />

410<br />

5,5<br />

19“-plug in version<br />

88<br />

230<br />

247<br />

483<br />

8<br />

7 175<br />

190<br />

140<br />

172,5<br />

210<br />

241<br />

155<br />

16,5<br />

784135.02 07/2003 paus Design & Medien, Bocholt Subject to alterations. Printed on chlorine free paper.<br />

Benning GmbH & Co. KG Tel. +49 (0)2871 93 - 0 Fax 93 - 380<br />

Münsterstraße 135 – 137 • D-46397 Bocholt<br />

E-Mail: info@benning.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!