APPENDIXES<br />

D—Service Test for Fire Hose<br />

and dust cannot be removed thoroughly by<br />

brushing, or if the hose has come in contact<br />

with harmful chemicals, it should be washed. If<br />

detergent is used, use a mild solution and<br />

rinse thoroughly with clean water.<br />

Wet hose should be drained and completely<br />

dried before being placed in service or<br />

storage. Hose should not be dried on hot<br />

pavements or under intense sunlight. Wet<br />

hose, even the lightweight all-synthetic,<br />

should be thoroughly dried. Cotton-synthetic<br />

hose has been treated for mildew protection<br />

but will mildew under prolonged wet<br />

conditions. In addition, linen hose must be<br />

thoroughly dried immediately after testing to<br />

avoid mildew.<br />

Allow the jacket to dry completely by hanging a<br />

50-foot length of hose from the middle. Hang a<br />

100-foot length of hose from the middle and<br />

allow to drain for a minimum of 4 hours. After 4<br />

hours, double the hose and continue to dry for<br />

2 to 3 days or longer as required. The<br />

couplings should be off the ground at all times.<br />

Salvaging bad hose<br />

All hose failing the visual exam and the<br />

pressure test should be tagged, repaired, or<br />

disposed of as per your agencies guidelines.<br />

In the field, tie a knot in failed hose to avoid<br />

reuse. If a 100-foot length of hose fails, it<br />

should be shortened to 50 feet. If a 50-foot<br />

length of hose fails, it should be shortened to<br />

no less than 45 feet. Good couplings should be<br />

salvaged from discarded hose.<br />

Hose that has been repaired or recoupled<br />

should be retested at a test pressure of at least<br />

50 percent greater than the service test<br />

pressure.<br />

Place a readily visible, distinguishing mark<br />

noting the location of the hose defect, before<br />

sending it in. Good couplings should be<br />

salvaged from any hose not repairable. For<br />

defective couplings, the couplings should be<br />

cut from the hose and the hose sent in for recoupling.<br />

When a length of hose is recoupled,<br />

the tailpiece gasket should be replaced. For<br />

additional information, consult the “Fire<br />

<strong>Equipment</strong> Storage and Refurbishing<br />

Standards,” <strong>National</strong> <strong>Wildfire</strong> <strong>Coordinating</strong><br />

Group, NFES Number 2249, November 1994.<br />