WATER DELIVERY COMPONENTS AND ACCESSORIES<br />

Nozzles<br />

b. Spray<br />

5. Applicator pipe<br />

The spray requirements specify a uniform<br />

solid-cone mist with a minimum horizontal<br />

range of 12 feet. The flow rate at a tip<br />

pressure of 100 psi must be within the<br />

range shown in the following table:<br />

An applicator pipe, or wand, is available for<br />

reaching under logs, roots, stumps, and into<br />

the base of piled fuels. It can be used in deep<br />

duff, peat, and sawdust. The applicator is 52<br />

inches long, comes apart in the middle, and<br />

has a 15-degree bend near the end. All<br />

connections are w-inch GHT male threads to<br />

accommodate a special low-flow spray tip (3<br />

gal/min with a 60 degree pattern). It is also a<br />

component of the Mop-up Kit.<br />

Available from GSA: NSN 4210-01-412-5688<br />

Tip Discharge Angle Flow rate<br />

No. (deg) (gal/min)<br />

Min. Max. Min. Max.<br />

3 18 22 2.0 4.0<br />

6 18 22 5.0 7.0<br />

8 18 22 7.0 9.9<br />

9 26 30 8.0 10.0<br />

12 26 30 11.0 13.0<br />

15 26 30 13.5 16.5<br />

18 26 30 16.5 19.5<br />

24 26 30 22.5 25.5<br />

Available from GSA:<br />

Size 3<br />

NSN 4210-00-204-3358<br />

Size 6<br />

NSN 4210-00-204-3386<br />