Calculating <strong>the</strong> WQCV and <strong>Volume</strong> Reduction Chapter 3<br />

The same calculation is <strong>the</strong>n performed using <strong>the</strong> effective imperviousness for <strong>the</strong> 100-year event:<br />

V 100 I 100−yr Effective<br />

= −0.00005501 ∙ I 2<br />

100−yr Effective + 0.030148 ∙ I 100−yr Effective − 0.12<br />

12<br />

ft 3<br />

∙ Total Area ∙ 43560<br />

ac ∙ ft<br />

V 100 I 100−yr Effective = (−0.00005501 ∙ 47%2 + 0.030148 ∙ 47% − 0.12)<br />

∙ 1.15 ac ∙ 43560<br />

12<br />

= 4865 ft 3<br />

The reduction in <strong>the</strong> 100-year storage volume, as a result of <strong>the</strong> conveyance-based BMPs in Sub-basin A,<br />

is 5083 ft 3 – 4865 ft 3 = 218 ft 3 , a reduction of approximately 4.3%.<br />

Calculations for Sub-basin E include <strong>the</strong> following:<br />

V 100 I Total = −0.00005501 ∙ I 2<br />

Total + 0.030148 ∙ I Total − 0.12<br />

∙ Total Area ∙ 43560<br />

12<br />

V 100 I Total = (−0.00005501 ∙ 73%2 + 0.030148 ∙ 73% − 0.12)<br />

12<br />

∙ 0.15 ac ∙ 43560<br />

ft 3<br />

ac ∙ ft<br />

ft 3<br />

ac ∙ ft<br />

ft 3<br />

= 977 ft3<br />

ac ∙ ft<br />

The same calculation is <strong>the</strong>n performed using <strong>the</strong> effective imperviousness for <strong>the</strong> 100-year event:<br />

V 100 I 100−yr Effective<br />

= −0.00005501 ∙ I 2<br />

100−yr Effective + 0.030148 ∙ I 100−yr Effective − 0.12<br />

12<br />

ft 3<br />

∙ Total Area ∙ 43560<br />

ac ∙ ft<br />

V 100 I 100−yr Effective = (−0.00005501 ∙ 69%2 + 0.030148 ∙ 69% − 0.12)<br />

∙ 0.15 ac ∙ 43560<br />

12<br />

= 927 ft 3<br />

The reduction in <strong>the</strong> 100-year storage volume as a result of <strong>the</strong> volume-based BMPs in Sub-basin E is,<br />

<strong>the</strong>refore, 977ft 3 – 927 ft 3 = 50 ft 3 , a reduction of approximately 5%.<br />

ft 3<br />

ac ∙ ft<br />

3-30 <strong>Urban</strong> <strong>Drainage</strong> and Flood Control District August 2011<br />

<strong>Urban</strong> Storm <strong>Drainage</strong> <strong>Criteria</strong> <strong>Manual</strong> <strong>Volume</strong> 3