SNZ NZSrY202 95 = 8583Lbï 0042550 T5B =<br />

Issued June 1995 NZS 4202: 1 995<br />

SECTION 31 - GRID SUSPENDED CEILINGS<br />

31.1 OVERVIEW<br />

Referto section O, General rules, which shall be read in conjunction with this section.<br />

31.2 PREAMBLES<br />

31.2.1 Rates to include<br />

(a)<br />

(b)<br />

Straight cutting on tiles;<br />

Seismic supports, including supports for lights.<br />

31.3 GENERAL PRINCIPLES<br />

31.3.1<br />

Seismic classification shall be stated (e.g., Class III Zone C) where specified.<br />

31.3.2<br />

Exterior ceilings shall be scheduled separately.<br />

31.3.3<br />

For sloping ceilings the pitch shall be stated in degrees from horizontal.<br />

31.3.4<br />

Note shall be made if services are in the ceiling space.<br />

31.4 MEASUREMENT PROCEDURE<br />

31.4.1<br />

The suspension system shall be measured in square metres. The description shall<br />

include rails, hangers, spacers, and the like, the type and method of fixing, and the<br />

background material from which the system is suspended. The ceiling height above<br />

floor level and depth of ceiling space shall be stated.<br />

31.4.2<br />

Trimming suspension system for lightfittings, grilles, and the likeshall be enumerated<br />

as extra value.<br />

31.4.3<br />

Edge trim to the periphery of the suspension system or to columns, openings and the<br />

like, shall be measured in metres and the method of fixing shall be described. Trim<br />

tocolumns, openings and the like shall be measured as extra value and total number<br />

stated.<br />

31.4.4<br />

Ceiling tiles or infill panels shall be described and measured in square metres.<br />

Deductions for openings shall be made for whole tiles or whole panels only.<br />

31.4.5<br />

Openings or penetrations in ceiling tiles or panels for light fittings, grilles, sprinkler<br />

heads and the like shall be enumerated.<br />

31.4.6<br />

Raking and circular cutting to ceiling tiles or panels shall be measured in metres.<br />

31.4.7<br />

Seismic breaks, trunkings and the like shall be measured in metres.<br />

31.4.8<br />

The provision of shop drawings and design submissions shall be itemised.<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.<br />

31 -1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!