SNZ NZSr4202 95 8583369 0042504 078<br />

Issued June 1995 NZS 4202: 1 995<br />

SECTION 14 - STONE MASONRY<br />

14.1 OVERVIEW<br />

Refer to section O, General rules, which shall be read in conjunction with this section.<br />

14.2 PREAMBLES<br />

14.2.1 Rates to include<br />

(a)<br />

(b)<br />

Straight cutting;<br />

Cleaning on completion.<br />

14.3 GENERAL PRINCIPLES<br />

14.3.1<br />

Unless otherwise specified, stone masonry shall be scheduled in square metres<br />

stating the thickness.<br />

14.3.2<br />

Exterior work shall be scheduled separately from interior work.<br />

14.3.3<br />

Descriptions shall include details of:<br />

(a) Type, quality and general size of stones or slabs;<br />

(b) Texture and finish to exposed faces;<br />

(c) Composition and mix of mortar or details of other materials for bedding and<br />

jointing;<br />

(d) The general location and height to which work rises.<br />

14.3.4<br />

Circular work shall be scheduled separately stating if circular on one or both faces<br />

and the radius of the curve.<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

14.3.5<br />

Work to floors and walls shall be scheduled separately.<br />

14.3.6<br />

Work to floors to falls or cross falls shall be so described.<br />

14.3.7<br />

Work to sides, soff its and tops of beams and to sides of columns shall be scheduled<br />

separately.<br />

14.3.8<br />

Pattern workshall bescheduled separately and, if of different typesof stone, thearea<br />

of each type shall be stated. The description shall include all necessary cutting to<br />

form the pattern.<br />

14.3.9<br />

Work to isolated surfaces not exceeding 1 .O m2 shall be scheduled separately.<br />

14.3.10<br />

Work not exceeding 300 mm in width shall be scheduled in metres stating the width.<br />

This shall apply to all narrow widths except those in plane surfaces caused by<br />

openings and the like.<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.<br />

14-1