SNZ NZS*Y202<br />

95 D 8583169 OOi)2502 2T5 W<br />

Issued June 1995 NZS 4202: 1 995<br />

13.4 MEASUREMENT PROCEDURE<br />

13.4.1<br />

Each skin of blockwork in cavity walls shall be measured and so stated.<br />

13.4.2<br />

Forming cavities including ties shall be described and measured in square metres<br />

stating the material to which ties are fixed.<br />

13.4.3<br />

Deductions shall be made for all openings having an area of 0.4 m2 and over.<br />

13.4.4<br />

Surface treatments shall be measured separately in square metres.<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

13.4.5<br />

Half high courses, bond beams, lintels, sills, external angles, tee intersections and<br />

the like shall be measured separately in metres as extra value.<br />

13.4.6<br />

Control joints shall be described and measured in metres, including filling or pointing<br />

if required,<br />

13.4.7<br />

Pointing to grooves, chases, frames and the like shall be measured in metres.<br />

13.4.8<br />

Metal bonding shall be measured in metres.<br />

I 3.4.9<br />

Horizontal, raking and circular cutting shall be measured in metres.<br />

13.4.10<br />

Damp-proof coursing for blockwork shall be measured in metres. The widths and<br />

thicknesses shall be stated.<br />

13.4.1 1<br />

Flaunching to bottom of cavities shall be measured in metres including raking out<br />

joints for weepholes.<br />

13.4.12<br />

Rod reinforcement shall be measured in this section in accordance with section 9.<br />

13.4.1 3<br />

Solid filling to blockworkshall be described and measured in square metresfor each<br />

block thickness.<br />

13.4.14<br />

Intermittent concrete filling to cells of blocks, bond beam or column shall be<br />

described and measured separately in metres for each thickness of wall and each<br />

type of wall construction.<br />

13.4.1 5<br />

Filling to cavities between skins shall be described and measured in square metres<br />

stating the width of the cavity.<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.<br />

13-2