6.4.2 Measurement procedure<br />
6.4.2.1<br />
Unless otherwise provided, formwork shall be measured separately according to its<br />
position in the structure and classified as follows:<br />
(a)<br />
(b)<br />
(c)<br />
(d)<br />
(e)<br />
(f)<br />
Vertical surfaces of footings and the like;<br />
Vertical surfaces of walls;<br />
Vertical surfaces of columns, piers and the like;<br />
Flat soffits of suspended slabs. Formwork to slabs 200 mm in thickness and<br />
over shall be measured separately. If over 3.0 m in height, the height shall be<br />
stated in stages of 1 .O m.<br />
Sides of beams, lintels and the like;<br />
Soffits of beams, lintels and the like. If over 3.0 m in height, the height shall<br />
be stated in stages of 1 .O m.<br />
6.4.2.2<br />
Small surfaces such as cantilever ends, brackets, ends of steps, caps, bases and the<br />
like, shall be enumerated.<br />
6.4.2.3<br />
Cornices and mouldings shall be measured in metres and the girth stated.<br />
6.4.2.4<br />
Curved and sloping work. Sloping upper surfaces in excess of 15 degrees to the<br />
horizontal shall be measured.<br />
6.4.2.5<br />
Sides or soffits of concrete, reveals to openings 2.0 m2 and over and the like which<br />
do not exceed 300 mm wide shall be measured in metres and grouped as:<br />
(a)<br />
Not exceeding 100 mm;<br />
(b)<br />
(c)<br />
Over 100 mm and not exceeding 200 mm;<br />
Over 200 mm and not exceeding 300 mm.<br />
6.4.2.6<br />
Openings of less than 2.0 m2 shall be described and enumerated.<br />
6.4.2.7<br />
Forming or cutting grooves, chases and the like shall be scheduled in metres. Holes,<br />
mortises, pockets and the like shall be enumerated.<br />
6.4.2.8<br />
Expansion, contraction, and construction jointsdetailed in the documentsor required<br />
to be formed in specific locations shall be measured separately and fully described.<br />
6.4.2.9<br />
Joints shall be measured in metres if not exceeding 300 mm wide, or in square<br />
metres if exceeding 300 mm.<br />
6.4.2.1 O<br />
Water stops and the like shall be measured in metres and shall be scheduled<br />
immediately following the joint in which they occur. Junctions at changes of direction<br />
shall be enumerated.<br />
Copyright Standards New Zealand<br />
Provided by IHS under license with SNZ<br />
--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />
Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />
03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />
the Document Policy Group at 303-397-2295.<br />
6-4