12-2<br />

FAULT IDENTIFICATION AND ELIMINATION<br />

Gas installation<br />

Fault<br />

Lack of correct flame formation. e.g. at gas<br />

cooker<br />

When controller set at "small flame", flame<br />

extinguishes<br />

Refrigerator fails to work with gas mode<br />

Possible cause<br />

Gas pressure controller defective<br />

Ignition protection sensor incorrectly<br />

adjusted<br />

Gas cylinder valve or shut-off valve closed<br />

Remedy<br />

Consult specialist repair shop<br />

Consult specialist repair shop<br />

Open gas supply<br />

Heating/hot water<br />

Fault<br />

"Fault" pilot light (red) on Trumatic control<br />

element lights up permanently<br />

"Fault" pilot light (red) on Trumatic control<br />

element flashing.<br />

Possible cause<br />

No gas<br />

Air in pipe<br />

Protective device defective<br />

Surface-mounted battery too weak<br />

Remedy<br />

See above<br />

Switch unit off and switch on again after<br />

10 minutes<br />

Consult Truma Service<br />

Charge battery<br />

Replace if battery defective.