5-4<br />

GAS INSTALLATION<br />

Heating and Hot Water Supply<br />

E = Yellow pilot light "Boiler heat-up phase"<br />

Lights up during the heating-up phase of<br />

the boiler. When the water or air tempera<br />

ture set has been reached the light goes<br />

off.<br />

Start-up of the heating and boiler:<br />

1. Switch on power supply at<br />

control panel (p. 6-1).<br />

2. Open main valve on gas cylinder<br />

and shut-off valve (p. 5-2).<br />

3. Set desired temperature stage at<br />

knob A.<br />

4. Set knob C to desired mode of<br />

operation.<br />

Switching off after extended shut-down:<br />

1. Bring knob C to the middle position.<br />

2. Drain boiler.<br />

3. Close gas valves.<br />

Note<br />

Note also the attached original operating<br />

instructions.<br />

Safety/drain valve with antifreeze<br />

The safety/drain valve is mounted on the floor<br />

in front of the boiler.<br />

When the button is out the valve is closed. To<br />

drain the boiler, press the button in.<br />

Note<br />

The valve only works when the power supply<br />

is guaranteed. If the body battery is<br />

disconnected or discharged, the valve will<br />

open and the boiler will drain.<br />

At temperatures below 3°C the antifreeze<br />

safeguard will drain the boiler automatically<br />

at the drain valve to prevent any frost<br />

damage to the unit.<br />

If the temperature drops below the response<br />

value during operation, turn the knob C to on<br />

the control element to winter mode (down)<br />

and close the valve by pulling the button out.<br />

The valve will only close from an ambient<br />

temperature of 8°C.<br />

Filling the boiler<br />

1. Pull the button on the safety valve out. At<br />

temperatures below 8°C, switch on the<br />

heating first so that the valve will not open.<br />

2. Switch on water pump at control panel<br />

(p. 6-1).<br />

3. Set single-lever mixer tap in the bathroom<br />

or kitchen to "Hot" and leave open until the<br />

water flows in a powerful stream.<br />

Note<br />

When filling the boiler, take care to ensure<br />

that the drain valve for fresh water pipes is<br />

closed (p. 7-2).