GAS INSTALLATION 5-3<br />

Heating and Hot Water Supply<br />

C<br />

A<br />

E<br />

D<br />

B<br />

Up<br />

Middle<br />

Down 1<br />

Down 2<br />

The Trumatic heating system in your<br />

<strong>Karmann</strong> <strong>Mobil</strong>e Home is equipped in<br />

addition with an integrated 12 ltr. Boiler to<br />

supply the bathroom and the kitchen with hot<br />

water. The combination unit is located under<br />

the wardrobe (550, 600, 650, 660, 655TI, 665TI,<br />

675TI) and under the bed (625TI). The control<br />

element is mounted above the body door. The<br />

warmed heating air is distributed throughout<br />

the living room by means of a circulation fan.<br />

In summer mode (water heating without room<br />

heating) the service water is heated up on<br />

the lowest burner stage. Once the water<br />

temperature set has been reached, the<br />

burner switches off. The yellow lamp (E) goes<br />

out.<br />

In winter mode the unit determines<br />

automatically through the thermostat which<br />

burner stage is needed.<br />

Once the desired temperature has been<br />

reached:<br />

- with the switch at Down 1, the heating<br />

switches off regardless of the water<br />

temperature, and with the boiler full the<br />

water is automatically also heated, or<br />

- with the switch at Down 2, the hot air fan of<br />

the heating switches off and the content of<br />

the boiler is heated up to 60°C at the lowest<br />

burner stage.<br />

Control element and modes of<br />

operation<br />

A = Knob for room temperature<br />

When the unit is switched on the green<br />

pilot light (B) of the knob must light up. If<br />

the light does not light up, check the fuse<br />

III on the control panel (p. 6-2).<br />

C = Knob with five positions<br />

- Up = Boiler (summer mode,<br />

temperature 60°C or 40°C)<br />

- Middle = Off<br />

- Down 1 = Heating + Boiler (winter mode,<br />

without hot water requirement)<br />

- Down 2 = Heating + Boiler (winter mode,<br />

with hot water requirements, 60°C)<br />

D = Red pilot light "Fault"<br />

Indicates a fault in the gas or power sup<br />

ply. In such a case consult the fault table<br />

(see p. 12-2) or the attached operating in<br />

structions of the combination unit.