5-2<br />
GAS INSTALLATION<br />
Gas Supply<br />
Gas distributor block<br />
The gas distributor block is located in the<br />
kitchen block. Each consumer has its own<br />
fast-acting closure valve there which opens<br />
or closes the gas supply. The valves are<br />
marked with pictograms on the knob.<br />
A = Heating<br />
B = Refrigerator<br />
C = Gas cooker<br />
Where the gas distributor is installed in<br />
vertical position (for example see picture),<br />
the knobs are open when they are in the<br />
horizontal position; where the distributor is<br />
installed horizontally, they are open in<br />
vertical position. All gas devices are doubly<br />
secured. Please also note the attached<br />
operating instructions.<br />
If you do not use your mobile home for<br />
several days, you should always close your<br />
gas cylinders.<br />
The following safety instructions must be<br />
followed:<br />
No modifications may be made to the gas<br />
installation.<br />
The system may under no circumstances<br />
be connected to the municipal or longdistance<br />
gas mains.<br />
Every time the gas installation screw connections<br />
have been opened and every<br />
two years, a sealing and performance test<br />
must be conducted on the installation by<br />
authorised, skilled personnel.<br />
The gas devices may be operated with<br />
propane gas throughout the year, but<br />
butane does not become gaseous below<br />
0° C!<br />
The gas hose between the pressure<br />
controller and the gas installation must be<br />
checked regularly. If there is any porosity<br />
or an actual leak, it must be replaced<br />
immediately.<br />
The new hose must be in accordance<br />
with the standard printed on the old hose.<br />
The forced ventilation of the gas cylinder<br />
box may not be blocked (e.g. by slush,<br />
cleaning rags etc.) to ensure that the gas<br />
can escape if there is a leak.<br />
The forced ventilation must be inspected<br />
at regular intervals!