49 CFR-192 Transportation of Natural and Other Gas By Pipeline Subpart G, J, N.

Recommended practice for basic inspection requirements - new pipeline construction 49 CFR-192 The Code of Federal Regulations Transportation of Natural and Other Gas By Pipeline Subpart G, J, N. Recommended practice for basic inspection requirements
- new pipeline construction
49 CFR-192 The Code of Federal Regulations
Transportation of Natural and Other Gas By Pipeline Subpart G, J, N.

05.10.2014 Views

Recommended practice for basic inspection requirements - new pipeline construction 49 CFR-192 The Code of Federal Regulations Transportation of Natural and Other Gas By Pipeline Subpart G, J, N. 2014-October My Self Study Exam Preparatory Notes 49 Charlie Chong/ Fion Zhang

Recommended practice for basic inspection requirements<br />

- new pipeline construction<br />

<strong>49</strong> <strong>CFR</strong>-<strong>192</strong> The Code <strong>of</strong> Federal Regulations<br />

<strong>Transportation</strong> <strong>of</strong> <strong>Natural</strong> <strong>and</strong> <strong>Other</strong> <strong>Gas</strong> <strong>By</strong> <strong>Pipeline</strong> <strong>Subpart</strong> G, J, N.<br />

2014-October<br />

My Self Study Exam Preparatory Notes<br />

<strong>49</strong><br />

Charlie Chong/ Fion Zhang


Expert at Works<br />

Charlie Chong/ Fion Zhang


Make it easy to read for foreign c<strong>and</strong>idates like myself for API ICP exam:<br />

Charlie Chong/ Fion Zhang


Experts at Works<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Fion Zhang<br />

2014/October<br />

http://meilishouxihu.blog.163.com/<br />

Charlie Chong/ Fion Zhang


THE REFERENCES BELOW WILL BE AVAILABLE TO APPLICANTS ON<br />

THE COMPUTER SCREEN DURING THE EXAM:<br />

Code <strong>of</strong> Federal Regulations (<strong>CFR</strong>)<br />

• 29 <strong>CFR</strong> 1910, Occupational Safety <strong>and</strong> Health St<strong>and</strong>ards,<br />

<strong>Subpart</strong>s H Article 119,<br />

<strong>Subpart</strong> I (Excluding <strong>Subpart</strong> I Appendices) <strong>and</strong><br />

<strong>Subpart</strong> J Articles 145-147 (Excluding Appendices)<br />

Charlie Chong/ Fion Zhang


• 29 <strong>CFR</strong> <strong>192</strong>6, Safety <strong>and</strong> Health Regulations for Construction:<br />

<strong>Subpart</strong> C Articles 20-29 <strong>and</strong> 32-35,<br />

<strong>Subpart</strong> D Article 62 (Excluding Appendices),<br />

<strong>Subpart</strong> F Article 152,<br />

<strong>Subpart</strong> H Articles 250-251,<br />

<strong>Subpart</strong> J Article 351-354, <strong>Subpart</strong> L Article 451,<br />

<strong>Subpart</strong> M Article 500-501,<br />

<strong>Subpart</strong> O 600, <strong>Subpart</strong> P,<br />

<strong>Subpart</strong> U Article 900-902 <strong>and</strong> 914 <strong>and</strong><br />

<strong>Subpart</strong> CC Article 1417.<br />

Charlie Chong/ Fion Zhang


• 40 <strong>CFR</strong> 112, Oil Pollution Prevention, <strong>Subpart</strong> A<br />

• 40 <strong>CFR</strong> 122, EPA Administered Permit<br />

Charlie Chong/ Fion Zhang


• 40 <strong>CFR</strong> 112, Oil Pollution Prevention, <strong>Subpart</strong> A<br />

• 40 <strong>CFR</strong> 122, EPA Administered Permit Programs: The National Pollutant<br />

Discharge Elimination System: <strong>Subpart</strong> A<br />

• <strong>49</strong> <strong>CFR</strong> <strong>192</strong>, <strong>Transportation</strong> <strong>of</strong> <strong>Natural</strong> <strong>and</strong> <strong>Other</strong> <strong>Gas</strong> by <strong>Pipeline</strong>:<br />

Minimum Federal Safety St<strong>and</strong>ards: <strong>Subpart</strong>s G, J & N<br />

• <strong>49</strong> <strong>CFR</strong> 195, <strong>Transportation</strong> <strong>of</strong> Hazardous Liquids by <strong>Pipeline</strong>: <strong>Subpart</strong> D<br />

<strong>and</strong> <strong>Subpart</strong> E<br />

Charlie Chong/ Fion Zhang


Environmental Protection Agency (EPA), National Pollutant Discharge<br />

Elimination System General Permit for Discharges from Construction<br />

Activities 2012<br />

Charlie Chong/ Fion Zhang


<strong>49</strong> <strong>CFR</strong> - <strong>Transportation</strong><br />

http://www.law.cornell.edu/cfr/text/<strong>49</strong><br />

Charlie Chong/ Fion Zhang<br />

http://www.<strong>49</strong>cfr.info/index.html


Priority in the text<br />

• (a), (b).....<br />

• (1), (2)…..<br />

• (i), (ii)…..<br />

• (A), (B)…..<br />

At works<br />

Charlie Chong/ Fion Zhang


<strong>49</strong> <strong>CFR</strong> <strong>192</strong> <strong>Subpart</strong> G, J, N.<br />

<strong>Transportation</strong> <strong>of</strong> <strong>Natural</strong> <strong>and</strong> <strong>Other</strong> <strong>Gas</strong> <strong>By</strong><br />

<strong>Pipeline</strong>: Minimum Federal Safety St<strong>and</strong>ards<br />

THIS DOCUMENT CONTAINS ONLY THE SECTIONS<br />

NEEDED FOR THE API 1169 ICP EXAMS<br />

Formatted for My Self Study Exam Preparatory Notes<br />

Charlie Chong/ Fion Zhang


<strong>Subpart</strong> G -<br />

General Construction Requirements for<br />

Transmission Lines <strong>and</strong> Mains<br />

§<strong>192</strong>.301 Scope.<br />

This subpart prescribes minimum requirements for constructing<br />

transmission lines <strong>and</strong> mains.<br />

§<strong>192</strong>.303 Compliance with specifications or st<strong>and</strong>ards.<br />

Each transmission line or main must be constructed in accordance with<br />

comprehensive written specifications or st<strong>and</strong>ards that are consistent with<br />

this part.<br />

Keywords:<br />

■ Minimum;<br />

■ Compliance with specifications;<br />

■ Specifications Consistence with <strong>49</strong><strong>CFR</strong>;<br />

Charlie Chong/ Fion Zhang


12333 Each transmission line or main must be constructed in accordance with<br />

comprehensive written specifications or st<strong>and</strong>ards that are consistent with this<br />

part.<br />

Keywords:<br />

• Compliance with specifications or st<strong>and</strong>ards;<br />

• Specifications <strong>and</strong> st<strong>and</strong>ards in consistence with <strong>49</strong><strong>CFR</strong>;<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.305 Inspection: General.<br />

Each transmission line or main must be inspected to ensure that it is<br />

constructed in accordance with this part.<br />

§<strong>192</strong>.307 Inspection <strong>of</strong> materials.<br />

Each length <strong>of</strong> pipe <strong>and</strong> each other component must be visually inspected at<br />

the site <strong>of</strong> installation to ensure that it has not sustained any visually<br />

determinable damage that could impair its serviceability.<br />

§<strong>192</strong>.309 Repair <strong>of</strong> steel pipe.<br />

(a) Each imperfection or damage that impairs the serviceability <strong>of</strong> a length <strong>of</strong><br />

steel pipe must be repaired or removed. If a repair is made by grinding, the<br />

remaining wall thickness must at least be equal to either:<br />

(1) The minimum thickness required by the tolerances in the specification to<br />

which the pipe was manufactured; or<br />

(2) The nominal wall thickness required for the design pressure <strong>of</strong> the pipeline.<br />

Charlie Chong/ Fion Zhang


Discussion<br />

Topic: Differentiate the following:<br />

(1) The minimum thickness required by the tolerances in the specification to<br />

which the pipe was manufactured; or<br />

(2) The nominal wall thickness required for the design pressure <strong>of</strong> the pipeline.<br />

Charlie Chong/ Fion Zhang


(2) A dent that affects the longitudinal weld or a circumferential weld.<br />

(3) In pipe to be operated at a pressure that produces a hoop stress <strong>of</strong> 40<br />

percent or more <strong>of</strong> SMYS, a dent that has a depth <strong>of</strong>:<br />

(i) More than ¼ inch (6.4 millimeters) in pipe 12 ¾ inches (324 millimeters) or<br />

less in outer diameter; or<br />

(ii) More than 2 percent <strong>of</strong> the nominal pipe diameter in pipe over 12 ¾<br />

inches (324 millimeters) in outer diameter.<br />

For the purpose <strong>of</strong> this section a “dent” is a depression that produces a gross<br />

disturbance in the curvature <strong>of</strong> the pipe wall without reducing the pipe-wall<br />

thickness. The depth <strong>of</strong> a dent is measured as the gap between the lowest<br />

point <strong>of</strong> the dent <strong>and</strong> a prolongation <strong>of</strong> the original contour <strong>of</strong> the pipe.<br />

Charlie Chong/ Fion Zhang


(c) Each arc burn on steel pipe to be operated at a pressure that produces a<br />

hoop stress <strong>of</strong> 40 percent, or more, <strong>of</strong> SMYS must be repaired or removed. If<br />

a repair is made by grinding, the arc burn must be completely removed <strong>and</strong><br />

the remaining wall thickness must be at least equal to either:<br />

(1) The minimum wall thickness required by the tolerances in the specification<br />

to which the pipe was manufactured; or<br />

(2) The nominal wall thickness required for the design pressure <strong>of</strong> the pipeline.<br />

(d) A gouge, groove, arc burn, or dent may not be repaired by insert patching<br />

or by pounding out.<br />

(e) Each gouge, groove, arc burn, or dent that is removed from a length <strong>of</strong><br />

pipe must be removed by cutting out the damaged portion as a cylinder.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-1, 35 FR 17660,<br />

Nov. 17, 1970; Amdt. <strong>192</strong>-85, 63 FR 37503, July 13, 1998; Amdt. <strong>192</strong>-88, 64<br />

FR 69664, Dec. 14, 1999]<br />

Charlie Chong/ Fion Zhang


Arc Burn<br />

Charlie Chong/ Fion Zhang


Arc Burn<br />

Charlie Chong/ Fion Zhang


Arc Strike- Arc Burn<br />

Charlie Chong/ Fion Zhang<br />

http://kriznoy.wordpress.com/2013/08/30/arc-strike/


Arc Strike- Arc Burn<br />

Charlie Chong/ Fion Zhang<br />

http://kriznoy.wordpress.com/2013/08/30/arc-strike/


Arc Strike- Arc Burn<br />

Charlie Chong/ Fion Zhang


Arc Strike- Arc Burn<br />

Charlie Chong/ Fion Zhang<br />

http://met-tech.com/failure-analysis-<strong>of</strong>-ball-bearings.html


Arc Strike- Arc Burn<br />

Charlie Chong/ Fion Zhang


Arc Strike- Arc Burn<br />

Charlie Chong/ Fion Zhang


Discussion 1<br />

Topic: How to ensure total removal <strong>of</strong> Arc Burn.<br />

§<strong>192</strong>.309 (c) Each arc burn on steel pipe to be operated at a pressure that<br />

produces a hoop stress <strong>of</strong> 40 percent, or more, <strong>of</strong> SMYS must be repaired or<br />

removed. If a repair is made by grinding, the arc burn must be completely<br />

removed <strong>and</strong> the remaining wall thickness must be at least equal to either:<br />

Hints: Nitric acid 硝 酸<br />

Topic: Defines; a gouge, groove, arc burn <strong>and</strong> dent.<br />

(d) A gouge, groove, arc burn, or dent may not be repaired by insert patching<br />

or by pounding out.<br />

Charlie Chong/ Fion Zhang


Discussion 2<br />

Topic: Why is arc strike is an important issue in pipeline welding?<br />

§<strong>192</strong>.309 (e) Each gouge, groove, arc burn, or dent that is removed from a<br />

length <strong>of</strong> pipe must be removed by cutting out the damaged portion as a<br />

cylinder.<br />

Hint: High strength API 5LX material grade.<br />

Charlie Chong/ Fion Zhang


APL 5LX Pipe Technical Information.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.311 Repair <strong>of</strong> plastic pipe.<br />

Each imperfection or damage that would impair the serviceability <strong>of</strong> plastic<br />

pipe must be repaired or removed.<br />

[Amdt. <strong>192</strong>-93, 68 FR 53900, Sept. 15, 2003]<br />

Keywords:<br />

■<br />

Plastid Pipe<br />

Charlie Chong/ Fion Zhang


Plastid <strong>Pipeline</strong><br />

Charlie Chong/ Fion Zhang<br />

http://www.chings.co.nz/operations_pe_welding-1.html


Plastid Pipe<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.313 Bends <strong>and</strong> elbows.<br />

Each field bend in steel pipe, other than a wrinkle bend made in accordance<br />

with §<strong>192</strong>.315, must comply with the following:<br />

(1) A bend must not impair the serviceability <strong>of</strong> the pipe.<br />

(2) Each bend must have a smooth contour <strong>and</strong> be free from buckling, cracks,<br />

or any other mechanical damage.<br />

Keywords:<br />

■<br />

■<br />

■<br />

Wrinkle bend<br />

Buckling<br />

Crack<br />

Charlie Chong/ Fion Zhang


Bend & Wrinkle Bend<br />

Charlie Chong/ Fion Zhang


(3) On pipe containing a longitudinal weld, the longitudinal weld must be as<br />

near as practicable to the neutral axis <strong>of</strong> the bend unless:<br />

(i) The bend is made with an internal bending m<strong>and</strong>rel; or<br />

(ii) The pipe is 12 inches (305 millimeters) or less in outside diameter or has a<br />

diameter to wall thickness ratio less than 70.<br />

Keywords:<br />

• longitudinal weld must be as near as practicable to the neutral axis <strong>of</strong> the<br />

bend<br />

• Internal bend m<strong>and</strong>rel<br />

• Diameter/ Wall thickness ratio ˂ 70<br />

Charlie Chong/ Fion Zhang


Internal bending m<strong>and</strong>rel<br />

Charlie Chong/ Fion Zhang


(b) Each circumferential weld <strong>of</strong> steel pipe which is located where the stress<br />

during bending causes a permanent deformation in the pipe must be<br />

nondestructively tested either before or after the bending process.<br />

(c) Wrought-steel welding elbows <strong>and</strong> transverse segments <strong>of</strong> these elbows<br />

may not be used for changes in direction on steel pipe that is 2 inches (51<br />

millimeters) or more in diameter unless the arc length, as measured along the<br />

crotch, is at least 1 inch (25 millimeters).<br />

[Amdt. No. <strong>192</strong>-26, 41 FR 26018, June 24, 1976, as amended by Amdt. <strong>192</strong>-<br />

29, 42 FR 42866, Aug. 25, 1977; Amdt. <strong>192</strong>-29, 42 FR 60148, Nov. 25, 1977;<br />

Amdt. <strong>192</strong>-<strong>49</strong>, 50 FR 13225, Apr. 3, 1985; Amdt. <strong>192</strong>-85, 63 FR 37503, July<br />

13, 1998]<br />

Charlie Chong/ Fion Zhang


Discussion<br />

Topic: What is Wrought-steel welding elbows <strong>and</strong> transverse segments?<br />

§§<strong>192</strong>.313 (c) Wrought-steel ( 锻 的 / 加 工 的 ) welding elbows (mitered bend?)<br />

<strong>and</strong> transverse segments <strong>of</strong> these elbows may not be used for changes in<br />

direction on steel pipe that is 2 inches (51 millimeters) or more in diameter<br />

unless the arc length, as measured along the crotch, is at least 1 inch (25<br />

millimeters).<br />

Charlie Chong/ Fion Zhang


Discussion<br />

Topic: How to perform NDT on the field pipe bended.<br />

§§<strong>192</strong>.313 (b) Each circumferential weld <strong>of</strong> steel pipe which is located<br />

where the stress during bending causes a permanent deformation in the pipe<br />

must be nondestructively tested either before or after the bending process.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.315 Wrinkle bends in steel pipe.<br />

(a) A wrinkle bend may not be made on steel pipe to be operated at a<br />

pressure that produces a hoop stress <strong>of</strong> 30 percent, or more, <strong>of</strong> SMYS.<br />

(b) Each wrinkle bend on steel pipe must comply with the following:<br />

(1) The bend must not have any sharp kinks.<br />

(2) When measured along the crotch <strong>of</strong> the bend, the wrinkles must be a<br />

distance <strong>of</strong> at least one pipe diameter.<br />

(3) On pipe 16 inches (406 millimeters) or larger in diameter, the bend may<br />

not have a deflection <strong>of</strong> more than 1 ½° for each wrinkle.<br />

(4) On pipe containing a longitudinal weld the longitudinal seam must be as<br />

near as practicable to the neutral axis <strong>of</strong> the bend.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-85, 63 FR 37503,<br />

July 13, 1998]<br />

Charlie Chong/ Fion Zhang


Wrinkle bends<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.317 Protection from hazards.<br />

(a) The operator must take all practicable steps to protect each transmission<br />

line or main from washouts, floods, unstable soil, l<strong>and</strong>slides, or other<br />

hazards that may cause the pipeline to move or to sustain abnormal loads.<br />

In addition, the operator must take all practicable steps to protect <strong>of</strong>fshore<br />

pipelines from damage by mud slides, water currents, hurricanes, ship<br />

anchors, <strong>and</strong> fishing operations.<br />

(b) Each aboveground transmission line or main, not located <strong>of</strong>fshore or in<br />

inl<strong>and</strong> navigable water areas, must be protected from accidental damage<br />

by vehicular traffic or other similar causes, either by being placed at a safe<br />

distance from the traffic or by installing barricades.<br />

(c) <strong>Pipeline</strong>s, including pipe risers, on each platform located <strong>of</strong>fshore or in<br />

inl<strong>and</strong> navigable waters must be protected from accidental damage by<br />

vessels.<br />

[Amdt. <strong>192</strong>-27, 41 FR 34606, Aug. 16, 1976, as amended by Amdt. <strong>192</strong>-78,<br />

61 FR 28784, June 6, 1996]<br />

Charlie Chong/ Fion Zhang


Remark: Each aboveground transmission line or main, not located<br />

<strong>of</strong>fshore or in inl<strong>and</strong> navigable water areas, must be protected from accidental<br />

damage by vehicular traffic or other similar causes, either by being placed at<br />

a safe distance from the traffic or by installing barricades.<br />

Charlie Chong/ Fion Zhang


Subsea <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang


Subsea Pull Trencher<br />

Charlie Chong/ Fion Zhang


Subsea <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang<br />

http://www.geocean.fr/2014/02/17/kalinda-shallow-water-pipelay-barge-support-mcdermott-safaniya-field/


Inl<strong>and</strong> <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.319 Installation <strong>of</strong> pipe in a ditch.<br />

(a) When installed in a ditch, each transmission line that is to be operated at a<br />

pressure producing a hoop stress <strong>of</strong> 20 percent or more <strong>of</strong> SMYS must be<br />

installed so that the pipe fits the ditch so as to minimize stresses <strong>and</strong><br />

protect the pipe coating from damage.<br />

(b) When a ditch for a transmission line or main is backfilled, it must be<br />

backfilled in a manner that:<br />

(1) Provides firm support under the pipe; <strong>and</strong><br />

(2) Prevents damage to the pipe <strong>and</strong> pipe coating from equipment or from the<br />

backfill material.<br />

Charlie Chong/ Fion Zhang


Pipe Bending: <strong>Pipeline</strong> operating at hoop stress <strong>of</strong> 20 percent or more <strong>of</strong><br />

SMYS must be installed so that the pipe fits the ditch so as to minimize<br />

stresses <strong>and</strong> protect the pipe coating from damage.<br />

Charlie Chong/ Fion Zhang


Pipe Bending: <strong>Pipeline</strong> operating at hoop stress <strong>of</strong> 20 percent or more <strong>of</strong><br />

SMYS must be installed so that the pipe fits the ditch so as to minimize<br />

stresses <strong>and</strong> protect the pipe coating from damage.<br />

Charlie Chong/ Fion Zhang


Field Pipe Bending<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.321 Installation <strong>of</strong> plastic pipe.<br />

(a) Plastic pipe must be installed below ground level except as provided by<br />

paragraphs (g) <strong>and</strong> (h) <strong>of</strong> this section.<br />

(b) Plastic pipe that is installed in a vault ( 库 ) or any other below grade<br />

enclosure must be completely encased in gas-tight metal pipe <strong>and</strong> fittings<br />

that are adequately protected from corrosion.<br />

(c) Plastic pipe must be installed so as to minimize shear or tensile stresses.<br />

(d) Thermoplastic pipe that is not encased must have a minimum wall<br />

thickness <strong>of</strong> 0.090 inch (2.29 millimeters), except that pipe with an outside<br />

diameter <strong>of</strong> 0.875 inch (22.3 millimeters) or less may have a minimum wall<br />

thickness <strong>of</strong> 0.062 inch (1.58 millimeters).<br />

Charlie Chong/ Fion Zhang


(e) Plastic pipe that is not encased must have an electrically conducting wire<br />

or other means <strong>of</strong> locating the pipe while it is underground. Tracer wire<br />

may not be wrapped around the pipe <strong>and</strong> contact with the pipe must be<br />

minimized but is not prohibited. Tracer wire or other metallic elements<br />

installed for pipe locating purposes must be resistant to corrosion damage,<br />

either by use <strong>of</strong> coated copper wire or by other means<br />

(f) Plastic pipe that is being encased must be inserted into the casing pipe in<br />

a manner that will protect the plastic. The leading end <strong>of</strong> the plastic must<br />

be closed before insertion.<br />

Charlie Chong/ Fion Zhang


(g) Uncased plastic pipe may be temporarily installed above ground level<br />

under the following conditions:<br />

(1) The operator must be able to demonstrate that the cumulative<br />

aboveground exposure <strong>of</strong> the pipe does not exceed the manufacturer's<br />

recommended maximum period <strong>of</strong> exposure or 2 years, whichever is less.<br />

(2) The pipe either is located where damage by external forces is unlikely or is<br />

otherwise protected against such damage.<br />

(3) The pipe adequately resists exposure to ultraviolet light <strong>and</strong> high <strong>and</strong> low<br />

temperatures.<br />

Keywords:<br />

• Period: Manufacturer recommendation or 2 years Maximum<br />

• Damages from external mechanical source: Unlikely<br />

• Damages from environments: UV, high & low temperature.<br />

Charlie Chong/ Fion Zhang


h) Plastic pipe may be installed on bridges provided that it is:<br />

(1) Installed with protection from mechanical damage, such as installation in a<br />

metallic casing;<br />

(2) Protected from ultraviolet radiation; <strong>and</strong><br />

(3) Not allowed to exceed the pipe temperature limits specified in §<strong>192</strong>.123.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-78, 61 FR 28784,<br />

June 6, 1996; Amdt. <strong>192</strong>-85, 63 FR 37503, July 13, 1998; Amdt. <strong>192</strong>-93, 68<br />

FR 53900, Sept. 15, 2003; Amdt. <strong>192</strong>-94, 69 FR 32895, June 14, 2004]<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.323 Casing.<br />

Each casing used on a transmission line or main under a railroad or highway<br />

must comply with the following:<br />

(a) The casing must be designed to withst<strong>and</strong> the superimposed loads.<br />

(b) If there is a possibility <strong>of</strong> water entering the casing, the ends must be<br />

sealed.<br />

(c) If the ends <strong>of</strong> an unvented casing are sealed <strong>and</strong> the sealing is strong<br />

enough to retain the maximum allowable operating pressure <strong>of</strong> the pipe,<br />

the casing must be designed to hold this pressure at a stress level <strong>of</strong> not<br />

more than 72 percent <strong>of</strong> SMYS.<br />

(d) If vents are installed on a casing, the vents must be protected from the<br />

weather to prevent water from entering the casing.<br />

Charlie Chong/ Fion Zhang


Road & Highway Crossing<br />

Charlie Chong/ Fion Zhang


Road & Highway Crossing - Open Ends<br />

Charlie Chong/ Fion Zhang


Road & Highway Crossing - Open Ends<br />

Charlie Chong/ Fion Zhang


Road & Highway Crossing - Open Ends<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Casing for Crossing<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Casing for Crossing<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Casing for Crossing<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Casing for Crossing- Vented <strong>and</strong> un-vented<br />

Charlie Chong/ Fion Zhang<br />

http://www.farwestcorrosion.com/casing-spacers-seals/casing-fill/suggested-pipeline-casing-st<strong>and</strong>ard/


§<strong>192</strong>.325 Underground clearance.<br />

(a) Each transmission line must be installed with at least 12 inches (305<br />

millimeters) <strong>of</strong> clearance from any other underground structure not<br />

associated with the transmission line. If this clearance cannot be attained,<br />

the transmission line must be protected from damage that might result<br />

from the proximity <strong>of</strong> the other structure.<br />

(b) Each main must be installed with enough clearance from any other<br />

underground structure to allow proper maintenance <strong>and</strong> to protect against<br />

damage that might result from proximity to other structures.<br />

(c) In addition to meeting the requirements <strong>of</strong> paragraph (a) or (b) <strong>of</strong> this<br />

section, each plastic transmission line or main must be installed with<br />

sufficient clearance, or must be insulated, from any source <strong>of</strong> heat so as to<br />

prevent the heat from impairing the serviceability <strong>of</strong> the pipe.<br />

(d) Each pipe-type or bottle-type holder must be installed with a minimum<br />

clearance from any other holder as prescribed in §<strong>192</strong>.175(b).<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-85, 63 FR 37503,<br />

July 13, 1998]<br />

Charlie Chong/ Fion Zhang


Discussion<br />

Topic: What is this?<br />

§<strong>192</strong>.325 (d) Each pipe-type or bottle-type holder must be installed with a<br />

minimum clearance from any other holder as prescribed in §<strong>192</strong>.175(b).<br />

• Pipe-type?<br />

• Bottle-type holder?<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.327 Cover.<br />

(a) Except as provided in paragraphs (c), (e), (f), <strong>and</strong> (g) <strong>of</strong> this section, each<br />

buried transmission line must be installed with a minimum cover as follows:<br />

Location<br />

Inches (Millimeters)<br />

Class 1 locations<br />

Class 2, 3, <strong>and</strong> 4 locations<br />

Drainage ditches <strong>of</strong> public roads <strong>and</strong> railroad crossings<br />

Normal soil<br />

30 (762)<br />

36 (914)<br />

36 (914)<br />

Consolidated rock<br />

18 (457)<br />

24 (610)<br />

24 (610)<br />

(b) Except as provided in paragraphs (c) <strong>and</strong> (d) <strong>of</strong> this section, each buried<br />

main must be installed with at least 24 inches (610 millimeters) <strong>of</strong> cover.<br />

(c) Where an underground structure prevents the installation <strong>of</strong> a<br />

transmission line or main with the minimum cover, the transmission line or<br />

main may be installed with less cover if it is provided with additional<br />

protection to withst<strong>and</strong> anticipated external loads.<br />

Charlie Chong/ Fion Zhang


(d) A main may be installed with less than 24 inches (610 millimeters) <strong>of</strong><br />

cover if the law <strong>of</strong> the State or municipality:<br />

(1) Establishes a minimum cover <strong>of</strong> less than 24 inches (610 millimeters);<br />

(2) Requires that mains be installed in a common trench with other utility lines;<br />

<strong>and</strong><br />

(3) Provides adequately for prevention <strong>of</strong> damage to the pipe by external<br />

forces.<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Covers<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Covers<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Covers- Trench Breaker<br />

Charlie Chong/ Fion Zhang<br />

http://huckbody.com/?page_id=1088


<strong>Pipeline</strong> Covers – Consolidated Rock<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Covers – Consolidated Rock<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Covers<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Covers- Main<br />

Charlie Chong/ Fion Zhang


(e) Except as provided in paragraph (c) <strong>of</strong> this section, all pipe installed in a<br />

navigable river, stream, or harbor must be installed with a minimum cover<br />

<strong>of</strong> 48 inches (1,219 millimeters) in soil or 24 inches (610 millimeters) in<br />

consolidated rock between the top <strong>of</strong> the pipe <strong>and</strong> the underwater natural<br />

bottom (as determined by recognized <strong>and</strong> generally accepted practices).<br />

Keywords:<br />

Navigable River Crossing Covers:<br />

• Soil: 48 inches minimum<br />

• Consolidated rock: 24 inches minimum<br />

Charlie Chong/ Fion Zhang


Navigable River Crossing Covers<br />

Charlie Chong/ Fion Zhang


Navigable River Crossing Covers<br />

Charlie Chong/ Fion Zhang


Navigable River Crossing Covers<br />

Charlie Chong/ Fion Zhang


Navigable River Crossing Covers<br />

Charlie Chong/ Fion Zhang


River Crossing Covers- Non Navigable River<br />

Charlie Chong/ Fion Zhang


River Crossing Covers- Non Navigable River<br />

Charlie Chong/ Fion Zhang


(f) All pipe installed <strong>of</strong>fshore, except in the Gulf <strong>of</strong> Mexico <strong>and</strong> its inlets, under<br />

water not more than 200 feet (60 meters) deep, as measured from the<br />

mean low tide, must be installed as follows:<br />

(1) Except as provided in paragraph (c) <strong>of</strong> this section, pipe under water less<br />

than 12 feet (3.66 meters) deep, must be installed with a minimum cover <strong>of</strong><br />

36 inches (914 millimeters) in soil or 18 inches (457 millimeters) in<br />

consolidated rock between the top <strong>of</strong> the pipe <strong>and</strong> the natural bottom.<br />

(2) Pipe under water at least 12 feet (3.66 meters) deep must be installed so<br />

that the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is<br />

supported by stanchions, held in place by anchors or heavy concrete<br />

coating, or protected by an equivalent means.<br />

Keywords: Offshore <strong>Pipeline</strong> Covers<br />

Water depth < 12 feet: 36 inches minimum cover<br />

Water depth ≥ 12 feet: top <strong>of</strong> the pipe below natural bottom<br />

Charlie Chong/ Fion Zhang


(g) All pipelines installed under water in the Gulf <strong>of</strong> Mexico <strong>and</strong> its inlets, as<br />

defined in §<strong>192</strong>.3, must be installed in accordance with §<strong>192</strong>.612(b)(3).<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-27, 41 FR 34606,<br />

Aug. 16, 1976; Amdt. <strong>192</strong>-78, 61 FR 28785, June 6, 1996; Amdt. <strong>192</strong>-85, 63<br />

FR 37503, July 13, 1998; Amdt. <strong>192</strong>-98, 69 FR 48406, Aug. 10, 2004]<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang<br />

Gulf <strong>of</strong> Mexico


Offshore <strong>Pipeline</strong> Covers- Heaps or Buckling<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nord-stream.com/press-info/images/supervising-<strong>of</strong>-concrete-coating-processat-eupec-concrete-weight-coating-plant-in-mukran-germany-2779/?page=20


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nord-stream.com/press-info/images/supervising-<strong>of</strong>-concrete-coating-processat-eupec-concrete-weight-coating-plant-in-mukran-germany-2779/?page=20


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nord-stream.com/press-info/images/supervising-<strong>of</strong>-concrete-coating-processat-eupec-concrete-weight-coating-plant-in-mukran-germany-2779/?page=20


Offshore <strong>Pipeline</strong> Covers<br />

Pipe under water at least 12 feet (3.66 meters) deep must be installed so that<br />

the top <strong>of</strong> the pipe is below the natural bottom, unless the pipe is supported<br />

by stanchions, held in place by anchors or heavy concrete coating, or<br />

protected by an equivalent means.<br />

Charlie Chong/ Fion Zhang


Offshore Lay Barge – Non self navigating<br />

Charlie Chong/ Fion Zhang


Offshore Lay Barge with support vessels<br />

Charlie Chong/ Fion Zhang


Offshore Lay Barge with support vessels<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Barge<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Barge<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Barge<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Barge<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Barge<br />

Charlie Chong/ Fion Zhang


Subsea <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang<br />

http://www.cnoocengineering.com/en/single_news_content.aspx?news_id=12343


Offshore <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Trencher<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Mats<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Mats<br />

Charlie Chong/ Fion Zhang


Offshore <strong>Pipeline</strong> Mats<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.328 Additional construction requirements for steel pipe using<br />

alternative maximum allowable operating pressure.<br />

For a new or existing pipeline segment to be eligible for operation at the<br />

alternative maximum allowable operating pressure calculated under<br />

§<strong>192</strong>.620, a segment must meet the following additional construction<br />

requirements. Records must be maintained, for the useful life <strong>of</strong> the pipeline,<br />

demonstrating compliance with these requirements:<br />

Charlie Chong/ Fion Zhang


To address this<br />

construction issue:<br />

(a) Quality assurance<br />

The pipeline segment must meet this additional construction<br />

requirement:<br />

(1) The construction <strong>of</strong> the pipeline segment must be done under a<br />

quality assurance plan addressing pipe inspection, hauling <strong>and</strong><br />

stringing, field bending, welding, non‐destructive examination <strong>of</strong><br />

girth welds, applying <strong>and</strong> testing field applied coating, lowering <strong>of</strong><br />

the pipeline into the ditch, padding <strong>and</strong> backfilling, <strong>and</strong> hydrostatic<br />

testing.<br />

(2) The quality assurance plan for applying <strong>and</strong> testing field applied<br />

coating to girth welds must be:<br />

(i) Equivalent to that required under §<strong>192</strong>.112(f)(3) for pipe; <strong>and</strong><br />

(ii) Performed by an individual with the knowledge, skills, <strong>and</strong> ability<br />

to assure effective coating application.<br />

(b) Girth welds<br />

(1) All girth welds on a new pipeline segment must be nondestructively<br />

examined in accordance with §<strong>192</strong>.243(b) <strong>and</strong> (c).<br />

Charlie Chong/ Fion Zhang


(c) Depth <strong>of</strong> cover<br />

(1) Notwithst<strong>and</strong>ing any lesser depth <strong>of</strong> cover otherwise allowed in<br />

§<strong>192</strong>.327, there must be at least 36 inches (914 millimeters) <strong>of</strong> cover<br />

or equivalent means to protect the pipeline from outside force<br />

damage.<br />

(2) In areas where deep tilling or other activities could threaten<br />

the pipeline, the top <strong>of</strong> the pipeline must be installed at least one<br />

foot below the deepest expected penetration <strong>of</strong> the soil.<br />

(d) Initial strength<br />

testing<br />

(1) The pipeline segment must not have experienced failures indicative<br />

<strong>of</strong> systemic material defects during strength testing, including initial<br />

hydrostatic testing. A root cause analysis, including metallurgical<br />

examination <strong>of</strong> the failed pipe, must be performed for any failure<br />

experienced to verify that it is not indicative <strong>of</strong> a systemic concern.<br />

The results <strong>of</strong> this root cause analysis must be reported to each<br />

PHMSA pipeline safety regional <strong>of</strong>fice where the pipe is in service at<br />

least 60 days prior to operating at the alternative MAOP. An operator<br />

must also notify a State pipeline safety authority when the pipeline is<br />

located in a State where PHMSA has<br />

Charlie Chong/ Fion Zhang


(e) Interference<br />

currents<br />

(1) For a new pipeline segment, the construction must address the<br />

impacts <strong>of</strong> induced alternating current from parallel electric<br />

transmission lines <strong>and</strong> other known sources <strong>of</strong> potential interference<br />

with corrosion control.<br />

[72 FR 62176, Oct. 17, 2008]<br />

Charlie Chong/ Fion Zhang


Tilling Soil<br />

Charlie Chong/ Fion Zhang


PHMSA- U.S. Department <strong>of</strong> <strong>Transportation</strong> (DOT)<br />

<strong>Pipeline</strong> <strong>and</strong> Hazardous Materials<br />

Safety Administration<br />

Charlie Chong/ Fion Zhang


Tilling Soil<br />

Charlie Chong/ Fion Zhang


Discussion<br />

Topic: What is §<strong>192</strong>.620<br />

Answer: Read http://www.gpo.gov/fdsys/pkg/<strong>CFR</strong>-2009-title<strong>49</strong>-vol3/pdf/<strong>CFR</strong>-<br />

2009-title<strong>49</strong>-vol3-sec<strong>192</strong>-620.pdf<br />

1. What is the alternative MAOP Rule?<br />

The alternate MAOP Rule was promulgated ( 颁 布 ) by PHMSA to allow certain<br />

gas transmission pipelines to operate at higher pressures <strong>and</strong> pipeline stress<br />

levels than regulations previously allowed if certain conditions are met that<br />

ensure an adequate margin <strong>of</strong> safety. <strong>By</strong> allowing pipelines to operate at<br />

higher pressures <strong>and</strong> stress levels, greater efficiencies <strong>and</strong> gas product<br />

throughput can be achieved (73 FR 62148). ………& more…<br />

More on http://primis.phmsa.dot.gov/maop/faqs.htm<br />

Charlie Chong/ Fion Zhang


<strong>Subpart</strong> J -<br />

Test Requirements<br />

§<strong>192</strong>.501 Scope.<br />

This subpart prescribes minimum leak-test <strong>and</strong> strength-test requirements for<br />

pipelines.<br />

§<strong>192</strong>.503 General requirements.<br />

(a) No person may operate a new segment <strong>of</strong> pipeline, or return to service a<br />

segment <strong>of</strong> pipeline that has been relocated or replaced, until –<br />

(1) It has been tested in accordance with this subpart <strong>and</strong> §<strong>192</strong>.619 to<br />

substantiate the maximum allowable operating pressure; <strong>and</strong><br />

(2) Each potentially hazardous leak has been located <strong>and</strong> eliminated.<br />

Charlie Chong/ Fion Zhang


(b) The test medium must be liquid, air, natural gas, or inert gas that is –<br />

(1) Compatible with the material <strong>of</strong> which the pipeline is constructed;<br />

(2) Relatively free <strong>of</strong> sedimentary materials; <strong>and</strong><br />

(3) Except for natural gas, nonflammable.<br />

(c) Except as provided in §<strong>192</strong>.505(a), if air, natural gas, or inert gas is used<br />

as the test medium, the following maximum hoop stress limitations apply:<br />

Class location<br />

Maximum hoop stress allowed as percentage <strong>of</strong> SMYS<br />

<strong>Natural</strong> gas<br />

Air or inert gas<br />

1<br />

2<br />

3<br />

4<br />

80<br />

30<br />

30<br />

30<br />

80<br />

75<br />

50<br />

40<br />

Charlie Chong/ Fion Zhang


(d) Each joint used to tie in a test segment <strong>of</strong> pipeline is excepted from the<br />

specific test requirements <strong>of</strong> this subpart, but each non-welded joint must be<br />

leak tested at not less than its operating pressure.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-58, 53 FR 1635, Jan.<br />

21, 1988; Amdt. <strong>192</strong>-60, 53 FR 36029, Sept. 16, 1988; Amdt. <strong>192</strong>-60A, 54 FR<br />

5485, Feb. 3, 1989]<br />

Charlie Chong/ Fion Zhang


Discussion<br />

Topic: The quoted Maximum hoop stress allowed as % <strong>of</strong> SMYS, is it meant<br />

for testing?<br />

Class location<br />

Maximum hoop stress allowed as percentage <strong>of</strong> SMYS<br />

1<br />

2<br />

<strong>Natural</strong> gas<br />

80<br />

30<br />

Air or inert gas<br />

80<br />

75<br />

Charlie Chong/ Fion Zhang


§ <strong>192</strong>.5 Class locations.<br />

(a) This section classifies pipeline locations for purposes <strong>of</strong> this part. The<br />

following criteria apply to classifications under this section.<br />

(1) A “class location unit” is an onshore area that extends 220 yards (200<br />

meters) on either side <strong>of</strong> the centerline <strong>of</strong> any continuous 1- mile (1.6<br />

kilometers) length <strong>of</strong> pipeline.<br />

(2) Each separate dwelling unit in a multiple dwelling unit building is counted<br />

as a separate building intended for human occupancy.<br />

pipeline<br />

220 yards<br />

220 yards<br />

1 mile/ 1.6 KM<br />

Charlie Chong/ Fion Zhang<br />

http://www.law.cornell.edu/cfr/text/<strong>49</strong>/<strong>192</strong>.5


(b) Except as provided in paragraph (c) <strong>of</strong> this section, pipeline locations are<br />

classified as follows:<br />

(1) A Class 1 location is:<br />

(i) An <strong>of</strong>fshore area; or<br />

(ii) Any class location unit that has 10 or fewer buildings intended for human<br />

occupancy.<br />

Charlie Chong/ Fion Zhang


(2) A Class 2 location is any class location unit that has more than 10 but<br />

fewer than 46 buildings intended for human occupancy.<br />

(3) A Class 3 location is:<br />

(i) Any class location unit that has 46 or more buildings intended for human<br />

occupancy; or<br />

(i) An area where the pipeline lies within 100 yards (91 meters) <strong>of</strong> either a<br />

building or a small, well-defined outside area (such as a playground,<br />

recreation area, outdoor theater, or other place <strong>of</strong> public assembly) that is<br />

occupied by 20 or more persons on at least 5 days a week for 10 weeks in<br />

any 12-month period. (The days <strong>and</strong> weeks need not be consecutive.)<br />

Charlie Chong/ Fion Zhang


(4) A Class 4 location is any class location unit where buildings with four (4)<br />

or more stories above ground are prevalent.<br />

(c) The length <strong>of</strong> Class locations 2, 3, <strong>and</strong> 4 may be adjusted as follows:<br />

(1) A Class 4 location ends 220 yards (200 meters) from the nearest building<br />

with four or more stories above ground.<br />

(2) When a cluster <strong>of</strong> buildings intended for human occupancy requires a<br />

Class 2 or 3 location, the class location ends 220 yards (200 meters) from<br />

the nearest building in the cluster.<br />

[Amdt. <strong>192</strong>-78, 61 FR 28783, June 6, 1996; 61 FR 35139, July 5, 1996, as<br />

amended by Amdt. <strong>192</strong>-85, 63 FR 37502, July 13, 1998]<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.505 Strength test requirements for steel pipeline to operate at a<br />

hoop stress <strong>of</strong> 30 percent or more <strong>of</strong> SMYS.<br />

(a) Except for service lines, each segment <strong>of</strong> a steel pipeline that is to operate<br />

at a hoop stress <strong>of</strong> 30 percent or more <strong>of</strong> SMYS must be strength tested in<br />

accordance with this section to substantiate the proposed maximum<br />

allowable operating pressure.<br />

In addition, in a Class 1 or Class 2 location, if there is a building intended for<br />

human occupancy within 300 feet (91 meters) <strong>of</strong> a pipeline, a hydrostatic test<br />

must be conducted to a test pressure <strong>of</strong> at least 125 percent <strong>of</strong> maximum<br />

operating pressure on that segment <strong>of</strong> the pipeline within 300 feet (91 meters)<br />

<strong>of</strong> such a building, but in no event may the test section be less than 600 feet<br />

(183 meters) unless the length <strong>of</strong> the newly installed or relocated pipe is less<br />

than 600 feet (183 meters).<br />

However, if the buildings are evacuated while the hoop stress exceeds 50<br />

percent <strong>of</strong> SMYS, air or inert gas may be used as the test medium.<br />

Charlie Chong/ Fion Zhang


(b) In a Class 1 or Class 2 location, each compressor station regulator station,<br />

<strong>and</strong> measuring station, must be tested to at least Class 3 location test<br />

requirements.<br />

(c) Except as provided in paragraph (e) <strong>of</strong> this section, the strength test must<br />

be conducted by maintaining the pressure at or above the test pressure<br />

for at least 8 hours.<br />

(d) If a component other than pipe is the only item being replaced or added to<br />

a pipeline, a strength test after installation is not required, if the<br />

manufacturer <strong>of</strong> the component certifies that-<br />

(1) The component was tested to at least the pressure required for the<br />

pipeline to which it is being added;<br />

(2) The component was manufactured under a quality control system that<br />

ensures that each item manufactured is at least equal in strength to a<br />

prototype <strong>and</strong> that the prototype was tested to at least the pressure<br />

required for the pipeline to which it is being added; or<br />

(3) The component carries a pressure rating established through applicable<br />

ASME/ANSI, MSS specifications, or by unit strength calculations as<br />

described in §<strong>192</strong>.143.<br />

Charlie Chong/ Fion Zhang


(e) For fabricated units <strong>and</strong> short sections <strong>of</strong> pipe, for which a post installation<br />

test is impractical, a preinstallation strength test must be conducted by<br />

maintaining the pressure at or above the test pressure for at least 4 hours.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-85, 63 FR 37504,<br />

July 13, 1998; Amdt. <strong>192</strong>-94, 69 FR 32895, June 14, 2004; Amdt. 195-94, 69<br />

FR 54592, Sept. 9, 2004]<br />

Charlie Chong/ Fion Zhang


Keywords: Testing pressure & Medium<br />

• Operating condition: 30% <strong>of</strong> SMYS;<br />

• Area Class: 1 or 2;<br />

• Occupancy criteria: a building within 300 feet within pipe center line;<br />

• Testing requirements: Hydrostatic testing at 125% <strong>of</strong> MOP.<br />

• Exclusion: However, if the buildings are evacuated while the hoop stress<br />

exceeds 50 percent <strong>of</strong> SMYS, air or inert gas may be used as the test<br />

medium.<br />

Question: Area Class 2 & 4 what are the testing requirements?<br />

Charlie Chong/ Fion Zhang


Keywords: Test Duration at rated pressure<br />

Operating condition: 30% <strong>of</strong> SMYS;<br />

• the strength test must be conducted by maintaining the pressure at or<br />

above the test pressure for at least 8 hours.<br />

• For fabricated units <strong>and</strong> short sections <strong>of</strong> pipe, for which a post installation<br />

test is impractical, a pre-installation strength test must be conducted by<br />

maintaining the pressure at or above the test pressure for at least 4 hours.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.505 However, if the buildings are evacuated while the hoop stress<br />

exceeds 50 percent <strong>of</strong> SMYS, air or inert gas may be used as the test<br />

medium.<br />

Charlie Chong/ Fion Zhang<br />

http://portolaplanet.com/2012/06/pge-pipeline-testing-keeps-the-portola-safe/


§<strong>192</strong>.507 Test requirements for pipelines to operate at a hoop stress<br />

less than 30 percent <strong>of</strong> SMYS <strong>and</strong> at or above 100 p.s.i. (689 kPa) gage.<br />

Except for service lines <strong>and</strong> plastic pipelines, each segment <strong>of</strong> a pipeline that<br />

is to be operated at a hoop stress less than 30 percent <strong>of</strong> SMYS <strong>and</strong> at or<br />

above 100 p.s.i. (689 kPa) gage must be tested in accordance with the<br />

following:<br />

(a) The pipeline operator must use a test procedure that will ensure discovery<br />

<strong>of</strong> all potentially hazardous leaks in the segment being tested.<br />

(b) If, during the test, the segment is to be stressed to 20 percent or more <strong>of</strong><br />

SMYS <strong>and</strong> natural gas, inert gas, or air is the test medium -<br />

(1) A leak test must be made at a pressure between 100 p.s.i. (689 kPa) gage<br />

<strong>and</strong> the pressure required to produce a hoop stress <strong>of</strong> 20 percent <strong>of</strong> SMYS;<br />

or<br />

(2) The line must be walked to check for leaks while the hoop stress is held at<br />

approximately 20 percent <strong>of</strong> SMYS.<br />

Charlie Chong/ Fion Zhang


(c) The pressure must be maintained at or above the test pressure for at<br />

least 1 hour.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-58, 53 FR 1635, Jan.<br />

21, 1988; Amdt. <strong>192</strong>-85, 63 FR 37504, July 13, 1998]<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.509 Test requirements for pipelines to operate below 100 p.s.i.<br />

(689 kPa) gage. Except for service lines <strong>and</strong> plastic pipelines, each<br />

segment <strong>of</strong> a pipeline that is to be operated below 100 p.s.i. (689 kPa)<br />

gage must be leak tested in accordance with the following:<br />

(a) The test procedure used must ensure discovery <strong>of</strong> all potentially<br />

hazardous leaks in the segment being tested.<br />

(b) Each main that is to be operated at less than 1 p.s.i. (6.9 kPa) gage must<br />

be tested to at least 10 p.s.i. (69 kPa) gage <strong>and</strong> each main to be operated<br />

at or above 1 p.s.i. (6.9 kPa) gage must be tested to at least 90 p.s.i. (621<br />

kPa) gage.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-58, 53 FR 1635, Jan.<br />

21, 1988; Amdt. <strong>192</strong>-85, 63 FR 37504, July 13, 1998]<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.511 Test requirements for service lines.<br />

(a) Each segment <strong>of</strong> a service line (other than plastic) must be leak tested in<br />

accordance with this section before being placed in service. If feasible, the<br />

service line connection to the main must be included in the test; if not<br />

feasible, it must be given a leakage test at the operating pressure when<br />

placed in service.<br />

(b) Each segment <strong>of</strong> a service line (other than plastic) intended to be operated<br />

at a pressure <strong>of</strong> at least 1 p.s.i. (6.9 kPa) gage but not more than 40 p.s.i.<br />

(276 kPa) gage must be given a leak test at a pressure <strong>of</strong> not less than 50<br />

p.s.i. (345 kPa) gage.<br />

(c) Each segment <strong>of</strong> a service line (other than plastic) intended to be operated<br />

at pressures <strong>of</strong> more than 40 p.s.i. (276 kPa) gage must be tested to at<br />

least 90 p.s.i. (621 kPa) gage, except that each segment <strong>of</strong> a steel service<br />

line stressed to 20 percent or more <strong>of</strong> SMYS must be tested in accordance<br />

with §<strong>192</strong>.507 <strong>of</strong> this subpart.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-74, 61 FR 18517,<br />

Apr. 26, 1996; Amdt. <strong>192</strong>-85, 63 FR 37504, July 13, 1998]<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.513 Test requirements for plastic pipelines.<br />

(a) Each segment <strong>of</strong> a plastic pipeline must be tested in accordance with this<br />

section.<br />

(b) The test procedure must insure discovery <strong>of</strong> all potentially hazardous leaks<br />

in the segment being tested.<br />

(c) The test pressure must be at least 150 percent <strong>of</strong> the maximum operating<br />

pressure or 50 p.s.i. (345 kPa) gage, whichever is greater. However, the<br />

maximum test pressure may not be more than three times the pressure<br />

determined under §<strong>192</strong>.121, at a temperature not less than the pipe<br />

temperature during the test.<br />

(d) During the test, the temperature <strong>of</strong> thermoplastic material may not be more<br />

than 100 °F (38 °C), or the temperature at which the material's long-term<br />

hydrostatic strength has been determined under the listed specification,<br />

whichever is greater.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-77, 61 FR 27793,<br />

June 3, 1996; 61 FR 45905, Aug. 30, 1996; Amdt. <strong>192</strong>-85, 63 FR 37504, July<br />

13, 1998]<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.515 Environmental protection <strong>and</strong> safety requirements.<br />

(a) In conducting tests under this subpart, each operator shall insure that<br />

every reasonable precaution is taken to protect its employees <strong>and</strong> the<br />

general public during the testing. Whenever the hoop stress <strong>of</strong> the<br />

segment <strong>of</strong> the pipeline being tested will exceed 50 percent <strong>of</strong> SMYS, the<br />

operator shall take all practicable steps to keep persons not working on<br />

the testing operation outside <strong>of</strong> the testing area until the pressure is<br />

reduced to or below the proposed maximum allowable operating pressure.<br />

(b) The operator shall insure that the test medium is disposed <strong>of</strong> in a manner<br />

that will minimize damage to the environment.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.517 Records.<br />

(a) Each operator shall make, <strong>and</strong> retain for the useful life <strong>of</strong> the pipeline, a<br />

record <strong>of</strong> each test performed under §§<strong>192</strong>.505 <strong>and</strong> <strong>192</strong>.507. The record<br />

must contain at least the following information:<br />

(1) The operator's name, the name <strong>of</strong> the operator's employee responsible for<br />

making the test, <strong>and</strong> the name <strong>of</strong> any test company used.<br />

(2) Test medium used.<br />

(3) Test pressure.<br />

(4) Test duration.<br />

(5) Pressure recording charts, or other record <strong>of</strong> pressure readings.<br />

(6) Elevation variations, whenever significant for the particular test.<br />

(7) Leaks <strong>and</strong> failures noted <strong>and</strong> their disposition.<br />

(b) Each operator must maintain a record <strong>of</strong> each test required by<br />

§§<strong>192</strong>.509, <strong>192</strong>.511, <strong>and</strong> <strong>192</strong>.513 for at least 5 years.<br />

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. <strong>192</strong>-93, 68 FR 53901,<br />

Sept. 15, 2003]<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Testing<br />

Charlie Chong/ Fion Zhang


<strong>Pipeline</strong> Testing<br />

Charlie Chong/ Fion Zhang<br />

http://joyce-road.blogspot.com/2012/05/pipeline-construction_19.html


<strong>Pipeline</strong> Testing<br />

Charlie Chong/ Fion Zhang


<strong>Subpart</strong> N –<br />

Qualification <strong>of</strong> <strong>Pipeline</strong> Personnel<br />

SOURCE: Amdt. <strong>192</strong>-86, 64 FR 46865, Aug. 27, 1999, unless otherwise<br />

noted.<br />

§<strong>192</strong>.801 Scope.<br />

(a) This subpart prescribes the minimum requirements for operator<br />

qualification <strong>of</strong> individuals performing covered tasks on a pipeline<br />

facility.<br />

(a) For the purpose <strong>of</strong> this subpart, a covered task is an activity, identified by<br />

the operator, that:<br />

(1) Is performed on a pipeline facility;<br />

(2) Is an operations or maintenance task;<br />

(3) Is performed as a requirement <strong>of</strong> this part; <strong>and</strong><br />

(4) Affects the operation or integrity <strong>of</strong> the pipeline.<br />

Charlie Chong/ Fion Zhang


<strong>Subpart</strong> N –<br />

Qualification <strong>of</strong> <strong>Pipeline</strong> Personnel<br />

SOURCE: Amdt. <strong>192</strong>-86, 64 FR 46865, Aug. 27, 1999, unless otherwise<br />

noted.<br />

§<strong>192</strong>.801 Scope.<br />

(a) This subpart prescribes the minimum requirements for operator<br />

qualification <strong>of</strong> individuals performing covered tasks on a pipeline facility.<br />

(b) For the purpose <strong>of</strong> this subpart, a covered task is an activity, identified by<br />

the operator, that:<br />

(1) Is performed on a pipeline facility;<br />

(2) Is an operations or maintenance task;<br />

(3) Is performed as a requirement <strong>of</strong> this part; <strong>and</strong><br />

(4) Affects the operation or integrity <strong>of</strong> the pipeline.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.803 Definitions.<br />

Abnormal operating condition means a condition identified by the operator<br />

that may indicate a malfunction <strong>of</strong> a component or deviation from normal<br />

operations that may:<br />

(a) Indicate a condition exceeding design limits; or<br />

(b) Result in a hazard(s) to persons, property, or the environment.<br />

Evaluation means a process, established <strong>and</strong> documented by the operator,<br />

to determine an individual's ability to perform a covered task by any <strong>of</strong> the<br />

following:<br />

(a) Written examination;<br />

(b) Oral examination;<br />

(c) Work performance history review;<br />

(d) Observation during:<br />

(1) Performance on the job,<br />

(2) On the job training, or<br />

(3) Simulations;<br />

(e) <strong>Other</strong> forms <strong>of</strong> assessment.<br />

Charlie Chong/ Fion Zhang


Qualified means that an individual has been evaluated <strong>and</strong> can:<br />

(a) Perform assigned covered tasks; <strong>and</strong><br />

(b) Recognize <strong>and</strong> react to abnormal operating conditions.<br />

[Amdt. <strong>192</strong>-86, 64 FR 46865, Aug. 27, 1999, as amended by Amdt. <strong>192</strong>-90,<br />

66 FR 43523, Aug. 20, 2001]<br />

Keywords:<br />

(a) Perform assigned covered tasks; <strong>and</strong><br />

(b) Recognize <strong>and</strong> react to abnormal operating conditions.<br />

Charlie Chong/ Fion Zhang


Keywords:<br />

Qualified means that an individual has been evaluated <strong>and</strong> can:<br />

(a) Perform assigned covered tasks; <strong>and</strong><br />

(b) Recognize <strong>and</strong> react to abnormal operating conditions.<br />

Charlie Chong/ Fion Zhang


On the Job Training<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.805 Qualification program.<br />

Each operator shall have <strong>and</strong> follow a written qualification program. The<br />

program shall include provisions to:<br />

(a) Identify covered tasks;<br />

(b) Ensure through evaluation that individuals performing covered tasks are<br />

qualified;<br />

(c) Allow individuals that are not qualified pursuant ( 按 照 ) to this subpart to<br />

perform a covered task if directed <strong>and</strong> observed by an individual that is<br />

qualified;<br />

(d) Evaluate an individual if the operator has reason to believe that the<br />

individual's performance <strong>of</strong> a covered task contributed to an incident as<br />

defined in Part 191;<br />

(e) Evaluate an individual if the operator has reason to believe that the<br />

individual is no longer qualified to perform a covered task;<br />

Charlie Chong/ Fion Zhang


(f) Communicate changes that affect covered tasks to individuals performing<br />

those covered tasks;<br />

(g) Identify those covered tasks <strong>and</strong> the intervals at which evaluation <strong>of</strong> the<br />

individual's qualifications is needed;<br />

(h) After December 16, 2004, provide training, as appropriate, to ensure that<br />

individuals performing covered tasks have the necessary knowledge <strong>and</strong><br />

skills to perform the tasks in a manner that ensures the safe operation <strong>of</strong><br />

pipeline facilities; <strong>and</strong><br />

(i) After December 16, 2004, notify the Administrator or a state agency<br />

participating under <strong>49</strong> U.S.C. Chapter 601 if the operator significantly<br />

modifies the program after the Administrator or state agency has verified<br />

that it complies with this section.<br />

[Amdt. <strong>192</strong>-86, 64 FR 46865, Aug. 27, 1999, as amended by Amdt. <strong>192</strong>-100,<br />

70 FR 10335, Mar. 3, 2005]<br />

Charlie Chong/ Fion Zhang


Keywords:<br />

Provisions on evaluations <strong>of</strong>:<br />

Qualified personnel<br />

No longer qualified.<br />

Training provision after December 16, 2004<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.807 Recordkeeping.<br />

Each operator shall maintain records that demonstrate compliance with this<br />

subpart.<br />

(a) Qualification records shall include:<br />

(1) Identification <strong>of</strong> qualified individual(s);<br />

(2) Identification <strong>of</strong> the covered tasks the individual is qualified to perform;<br />

(3) Date(s) <strong>of</strong> current qualification; <strong>and</strong><br />

(4) Qualification method(s).<br />

(b) Records supporting an individual's current qualification shall be<br />

maintained while the individual is performing the covered task. Records <strong>of</strong><br />

prior qualification <strong>and</strong> records <strong>of</strong> individuals no longer performing covered<br />

tasks shall be retained for a period <strong>of</strong> five years.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.809 General.<br />

(a) Operators must have a written qualification program by April 27, 2001. The<br />

program must be available for review by the Administrator or by a state<br />

agency participating under <strong>49</strong> U.S.C. Chapter 601 if the program is under<br />

the authority <strong>of</strong> that state agency.<br />

(b) Operators must complete the qualification <strong>of</strong> individuals performing<br />

covered tasks by October 28, 2002.<br />

(c) Work performance history review may be used as a sole evaluation<br />

method for individuals who were performing a covered task prior to<br />

October 26, 1999.<br />

(d) After October 28, 2002, work performance history may not be used as a<br />

sole evaluation method.<br />

(e) After December 16, 2004, observation <strong>of</strong> on-the-job performance may not<br />

be used as the sole method <strong>of</strong> evaluation.<br />

[Amdt. <strong>192</strong>-86, 64 FR 46865, Aug. 27, 1999, as amended by Amdt. <strong>192</strong>-90,<br />

66 FR 43524, Aug. 20, 2001; Amdt. <strong>192</strong>-100, 70 FR 10335, Mar. 3, 2005]<br />

Charlie Chong/ Fion Zhang


Keywords:<br />

• Work performance history review<br />

• Observation <strong>of</strong> on-the-job performance<br />

Charlie Chong/ Fion Zhang


<strong>49</strong> <strong>CFR</strong>-<strong>192</strong> Numbers to be remembered<br />

Some numbers to<br />

be remember – at<br />

least knowing<br />

where to find them.<br />

Charlie Chong/ Fion Zhang


<strong>49</strong><strong>CFR</strong> §<strong>192</strong>.309 (b) Repair <strong>of</strong> steel pipe.<br />

(2) A dent that affects the longitudinal weld or a circumferential weld.<br />

(3) In pipe to be operated at a pressure that produces a hoop stress <strong>of</strong> 40<br />

percent or more <strong>of</strong> SMYS, a dent that has a depth <strong>of</strong>:<br />

(i) More than ¼ inch (6.4 millimeters) in pipe 12 ¾ inches (324 millimeters) or<br />

less in outer diameter; or<br />

(ii) More than 2 percent <strong>of</strong> the nominal pipe diameter in pipe over 12 ¾<br />

inches (324 millimeters) in outer diameter.<br />

For the purpose <strong>of</strong> this section a “dent” is a depression that produces a gross<br />

disturbance in the curvature <strong>of</strong> the pipe wall without reducing the pipe-wall<br />

thickness. The depth <strong>of</strong> a dent is measured as the gap between the lowest<br />

point <strong>of</strong> the dent <strong>and</strong> a prolongation <strong>of</strong> the original contour <strong>of</strong> the pipe.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.319 Installation <strong>of</strong> pipe in a ditch.<br />

When installed in a ditch, each transmission line that is to be operated at a<br />

pressure producing a hoop stress <strong>of</strong> 20 percent or more <strong>of</strong> SMYS must be<br />

installed so that the pipe fits the ditch so as to minimize stresses <strong>and</strong> protect<br />

the pipe coating from damage.<br />

Charlie Chong/ Fion Zhang


§<strong>192</strong>.325 Underground clearance.<br />

Each transmission line must be installed with at least 12 inches (305<br />

millimeters) <strong>of</strong> clearance from any other underground structure not<br />

associated with the transmission line. If this clearance cannot be attained,<br />

the transmission line must be protected from damage that might result<br />

from the proximity <strong>of</strong> the other structure.<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!