<strong>Restek</strong> <strong>Product</strong> <strong>Instruction</strong> Sheet -- ECD/FID Make-up Gas Kit<br />

4. Remove any existing make-up gas fittings or any inserts inside the 1/4" detector port.<br />

5. Route the 1/16" line through an existing oven hole to the variable flow outlet. If no hole exists,<br />

one will have to be drilled. Be sure to drill the hole in a place away from existing lines or<br />

electronics. Before pushing the tubing through the insulation, place a plastic cap or a piece of tape<br />

over the tubing end.<br />

6. Connect the 1/16" line to the variable flow restrictor gas outlet fitting.<br />

7. Insert the Silcosteel® guide (item 6). (Omit the Silcosteel guide if an FID will be used.) Connect<br />

the 1/4" make-up gas fitting (item 1) to the detector port using the 1/4" nut and ferrule (items 2 &<br />

3) provided.<br />

8. Cap off the column connection to the detector and leak-check all connections with <strong>Restek</strong>'s Leak<br />

Detective (cat.# 21607) or an equivalent leak detector. After confirming that all fittings are leakfree,<br />

adjust the variable flow restrictor to set the make-up gas flow as indicated in the instrument<br />

manual.<br />

9. Install the column using the 1/16" nut and ferrule (items 4 & 5) according to the procedure<br />

outlined in your instrument manual and <strong>Restek</strong>'s Capillary Column Installation Guide.<br />

* We highly re<strong>com</strong>mend using our heat treated instrument grade SS tubing (cat.# 21512) for plumbing<br />

the make-up gas system to avoid the possibility of contamination.<br />

Contact <strong>Restek</strong> Technical Service (or an <strong>au</strong>thorized distributor) if you have questions about the ECD/FID<br />

Make-up Gas Kit or any other <strong>Restek</strong> product.<br />

Australian Distributor - Chromalytic Technology Pty Ltd - Tel (03) 9762 2034 Fax (03) 9761169 www<br />

Copyright © 1998 <strong>Restek</strong> Corporation. All Rights Reserved.<br />

http://www.restekcorp.<strong>com</strong>/ecd-fid.htm (2 of 2) [8/18/01 6:48:57 PM]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!