# Vu-Tight ® Inlet Liners for l/4-1nch Packed Injection Port Conversion " • Visually observe the press-tight connection between the column end and liner. • Fits 0.32 and 0.53mm ID capillary columns (fits column ODs from 0.5mm to 0.8ram). • Slotted top prevents obstruction of carrier gas flow. • Two designs are available. • Operates in the direct injection mode. # Vu-Tight ® DI Liner (¼-inch OD) Can easily be packed with wool for dirty samples. cat.# 20342, (ea.) cat.# 20343, (5-pk.) cat.# 20344, (25-pk.) [] Cyclo Vu-Tight ® DI Liner (1~4-inch OD) Ideal for dirty samples. Prevents non-volatile residue from contaminating the column. cat.# 20787, (ea.) cat.# .20788, (5-pk.) CHROMalyticTECHnology Pty Ltd . . . distributors in Australia for . . . RESTEK Website : http://www.chromtech.net.au e-mail : info@chromtech.net.au Tel : +61 3 9762 2034 Fax : +61 3 9761 1169 # Vu-Tight* Installation Fittings Includes a l/4-inch stainless steel nut and graphite ferrule for attaching the liner to the GC inlet and a 1/4 to 1/16-inch stainless steel reducer, plus a l/4-inch and 0.5mm ID graphite ferrule for attaching the column to the liner. Vu-Tight ® Installation Fittings: cat.# 20504, (kit) . . . . .

Packed Column Column Inlet Conversion 341-2000 Uniliner Sleeve: # 20301, 20305, VU-Tight ® Liner: Instrument 20308, 203(19, Liner Adaptor: Liner Adaptor # 20342, 20343, Vu'Tight® 20315, 20316, # 20310 Fitting*: 20344, 20787, Fitting Kit: 20319, 20320, # 20312 & 20788 # 20504 20902, & 20903 Hewlett-Packard GCs (1/4-inch injection ports) Models: 5700. 5710. 5711. 5712. 5830. • • • 5840. 5880. 5890 Varian GCs (1/4,-inch injection ports) Models: 1200. 1400. 2100. 2400. 3300-3700 • • • • 4400. 4600. 6000 Tracor GCs (1/4-inch injection ports) • • • • Models: 540. 550. 560. 565. 570 Packard Becker GCs (1/4-inch injection ports) • • • • Models: 427. 428. 429. 430. 433. 436. 437. 438 Gow-Mac GCs (V4-inch injection ports) • • • • Models: 69-750. 69-550 HNU GCs (1/4-inch injection ports) • • • • Models: 301. 401. 421 Shimadzu Packed Column GCs (5mm injection ports) Models: GC-4. GC-6 thru 9. GC-14. GC-15. GC-16. GC-17. Mini • Perkin-Elmer GCs (1/4-inch injection ports) Models: 8000 Series. Sigma, IB-4B. 300. 2001. 2100 • Perkin-Elmer Auto SYS *See page 331 for 5mm Stainless Steel Adaptor Fitting description. Restek 's innovative inlet supplies are grade. 'A ' ! www.restekcorp.com Instrument Supplies

# Vu-Tight ® Inlet Liners for l/4-1nch Packed Injection Port<br />

<strong>Conversion</strong><br />

" • Visually observe the press-tight connection between the column<br />

end and liner.<br />

• Fits 0.32 and 0.53mm ID capillary columns (fits column ODs<br />

from 0.5mm to 0.8ram).<br />

• Slotted top prevents obstruction of carrier gas flow.<br />

• Two designs are available.<br />

• Operates in the direct injection mode.<br />

# Vu-Tight ® DI Liner (¼-inch OD)<br />

Can easily be packed with wool for dirty samples.<br />

cat.# 20342, (ea.)<br />

cat.# 20343, (5-pk.)<br />

cat.# 20344, (25-pk.)<br />

[] Cyclo Vu-Tight ® DI Liner (1~4-inch OD)<br />

Ideal for dirty samples. Prevents non-volatile residue from contaminating the column.<br />

cat.# 20787, (ea.)<br />

cat.# .20788, (5-pk.)<br />

CHROMalyticTECHnology Pty Ltd . . . distributors in Australia for . . . RESTEK<br />

Website : http://www.chromtech.net.<strong>au</strong> e-mail : info@chromtech.net.<strong>au</strong> Tel : +61 3 9762 2034 Fax : +61 3 9761 1169<br />

# Vu-Tight* Installation Fittings<br />

Includes a l/4-inch stainless steel nut and graphite ferrule for attaching the liner to the<br />

GC inlet and a 1/4 to 1/16-inch stainless steel reducer, plus a l/4-inch and 0.5mm ID graphite<br />

ferrule for attaching the column to the liner.<br />

Vu-Tight ® Installation Fittings: cat.# 20504, (kit)<br />

. . . . .