m L [kg/s]<br />

RESULTS & DISCUSSION<br />

To solve all of the non-linear equations, Engineering Equation Solver (EES) software is used.<br />

EES is an equation solver software that can iteratively solve thousands of linear or non-linear<br />

equations simultaneously. It has built in libraries <strong>for</strong> thermodynamic and fluid transport<br />

properties, thus it is widely used in the Mechanical Engineering field. It can also solve<br />

differential and integral equations, which is helpful <strong>for</strong> the optimization of parameters <strong>for</strong> the<br />

<strong>solar</strong> thermal <strong>bubble</strong> <strong>pump</strong> <strong>water</strong> heating <strong>system</strong>s.<br />

Mass Flow Rate VS Diameter<br />

0.12<br />

0.1<br />

0.08<br />

0.06<br />

0.04<br />

0.02<br />

0<br />

Pressure = 0.25 bars<br />

Pressure = 0.40 bars<br />

Pressure = 0.336 bars<br />

0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08<br />

D [m]<br />

Figure 7: Liquid Mass Flow Rate Versus Lift Tube Diameter <strong>for</strong> Varying System Pressure<br />

Conditions.<br />