56 <strong>Electric</strong> strikes<br />

<strong>Model</strong> <strong>118</strong><br />

for <strong>fire</strong> doors<br />

Fail-locked <strong>118</strong>F<br />

Technical attributes<br />

F<br />

for <strong>fire</strong> rated doors<br />

Minimum fitting size - maximum effect<br />

effeff Fire-rated <strong>Electric</strong> <strong>Strike</strong> <strong>118</strong>F with FaFix ® (FF)<br />

<strong>Model</strong> with basic equipment. Also useable as a heavy-duty electric strike.<br />

The advantages at a glance<br />

∙∙<br />

Radius keep, FaFix ® , adjustable by 3 mm<br />

∙∙<br />

FaFix ® latch adjustable in 0.5 mm increments<br />

∙∙<br />

Universal voltage<br />

∙∙<br />

Screw-in Terminal / plug-in connection<br />

∙∙<br />

Symmetrical design. DIN left/right as well as horizontal applicable<br />

<strong>Electric</strong>al data 10-24 V AC/DC 22-42 V AC/DC<br />

Continuous duty 11-13 V DC 22-26 V DC<br />

Rated resistance 43 Ω 200 Ω<br />

AC current consumption<br />

Current consumption DC (stabilised)<br />

Max. latch preload AC<br />

Max. latch preload DC (stabilised)<br />

250 mA (12V)<br />

500 mA (24V)<br />

280 mA (12V)<br />

560 mA (24V)<br />

200 N (12V)<br />

>350 N (24V)<br />

50 N (12V)<br />

200 N (24V)<br />

60 mA (24V)<br />

120 mA (24V)<br />

200 N (24V)<br />

>350 N (42V)<br />

50 N (24V)<br />

200 N (42V)<br />

25,5<br />

16<br />

Characteristics<br />

Adjustable latch (FF, FaFix ® )<br />

Adjustable electric strike<br />

(F, Fix)<br />

Monitoring contact (RR)<br />

Bi-directional diode<br />

Fail-locked<br />

•<br />

•<br />

•<br />

Technical attributes<br />

Break-in resistance<br />

Height<br />

Width<br />

Depth<br />

FaFix ® adjustment range<br />

Latch bolt engaging depth<br />

9000 N<br />

66 mm<br />

16 mm<br />

25,5 mm<br />

3 mm<br />

6 mm<br />

Installation position<br />

vertical <strong>and</strong> horizontal<br />

DIN door swing directions<br />

Load cycles for in-plant test 250000<br />

Universal 1<br />

Operating temperature range -15 °C to +40 °C<br />

Voltage<br />

Suitability for <strong>fire</strong> protection Yes<br />

Test certificate number P-120003624<br />

10-24 V AC/DC A7<br />

66<br />

45<br />

33<br />

22-42 V AC/DC B7<br />

Order no.<br />

<strong>118</strong>F-------- * * 1<br />

7,3<br />

8,9<br />

18,1<br />

0 3mm